ML18093A226

From kanterella
Jump to navigation Jump to search
Forwards Safety Insp Repts 50-272/87-15 & 50-311/87-18 on 870519-0615 & Notice of Violation.Ack Receipt of 870529 & 0610 Responses to Violations Noted in Insp Repts 50-272/87-11 & 50-311/87-11.Corrective Actions Acceptable
ML18093A226
Person / Time
Site: Salem  PSEG icon.png
Issue date: 07/09/1987
From: Gallo R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Corbin McNeil
Public Service Enterprise Group
Shared Package
ML18093A227 List:
References
NUDOCS 8707160784
Download: ML18093A226 (2)


See also: IR 05000272/1987015

Text

Docket Nos.

50-272

50-311

09 JUL 1987

Public Service Electric and Gas Company

ATTN:

Mr. Corbin A. McNeill, Jr.

Senior Vice President - Nuclear

P. 0. Box 236

Hancocks Bridge, New Jersey 08038

Gentlemen:

Subject:

Combined Inspection 50-272/87-15 and 50-311/87-18

This refers to the routine resident safety inspection by Mr. T. Kenny and

Mrs. K. Gibson, of this office, on May 19, 1987 to June 15, 1987, at the

Salem Nutlear Generating Stati~n, Hancocks Bridge, New Jersey.

The

inspection consisted of dotument reviews, interviews, and observation of

activities. The findings were discussed with Mr. J. M. Zupko, Jr. of your

staff.

In addition, a telephone discussion between Mr. J. M. Zupko, Jr. and

Mr. R. M. Gallo occurred.on June 26, 1987 pertaining to an unresolved item on

containment isolation valves.

Your actions taken to resolve this matter will

be reviewed during a future inspection.

Based on the results of this inspection, it appears that one of your

activities was not conducted in full compliance with NRC requirements, as

set forth in the Notice of Violation, enclosed herewith as Appendix A~

This violation has been categorized by severity level in accordance with

the "General Statement of Policy and Procedure for NRC Enforcement

Actions," 10 CFR Part 2, Appendix C (Enforcement Policy 1986).

You are

required to respond to this letter and in preparing your response, you

should follow the instructions in Appendix A.

The responses directed by this letter and the accompanying Notice are not

subject to the clearance procedures of the Office of Management and' Budget

as required by the Paperwork Reduction Act of 1980, PL 96-511.

This letter a.l so acknowledges receipt of your responses dated May 29, 1987

and June 10, 1987 to the violations cited in Inspection Reports

50-311/87-11 and 50-272/87-11 respectively.

Your corrective actions for

violation 50-311/87-11-01 have been reviewed and found acceptable as

discussed in Section 2 of the attached report.

Your corrective actions for

violation 50-272/87-11-01 will be reviewed in a future inspection.

OFFICIAL-RECORD COPY

~70 7/60?Jf-

CIR SALEM 87-15/18 - 0001.0.0

07/06/87

Public Service Electric and

Gas Company

2

Your cooperation with us in this matter is appreciated.

Sincerely,

0 9 JUL *1937

E~

!l iiSMd :ey 1

Enclosures:

1. *Appendix A, Notice of Violation

Robert M. Gallo, Chief

Projects Branch No. 2

Division of Reactor Projects

2.

NRC Combined Report 50-272/87-15 and 50-311/87-18

cc w/encls:

S. E. Miltenberger, Vice President - Nuclear Operations

J.M. Zupko, Jr., General Manager - Salem Operations

L. A. Reiter, General Manager - Licensing and Regulation

B. A. Preston, Manager, Licensing and Regulation

C. P. Johnson, General Manager - Nuclear Quality Assurance

J. H. MacKinnon, General Manager - Nuclear Safety Review

M~ J. Wetterhahn, Esquire

R. Fryling, *Jr., Esquire

T. S. Shaw, Jr., Vice President-* Production, Delmarva Power

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center

NRC Resident Inspector

State of New Jersey

bee:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

DRP Section Chief

Robert J. Bores, DRSS

~ RI:DRP

/fcfi.. Summers/rh l

~

i/\\187

6/jD/87 *

OFFICIAL RECORD COPY

CIR SALEM 87-15/18 - 0001.1.0

06/29/87