GENERIC REPORT OVERPRES SURE PROTECTION FOR OPERATING CE HSSS December 3, 1976 Prepared by Combustion Engineering, Inc.

for jo

/AU ~

v~

+

gab

+

Q>$ >

Consumers Power Co.

Baltimore Gas

& Electric Plorida Power 6 Light Co.

Northeast Utilities Omaha Public Po~er District g~ graf Bent'!ref g

Cng~xcI P em 0 }!P,ZM HFQ~Jgggp YDOCKgpgg ~

g s~ ~ei'-'>

o 7

ABSTRACT A generic study concerning overpressure protection during low temperature operation for operating Combustion Engineering Nuclear Steam Supply Systems has been completed.

Results of analytical modeling indicates long term means of prrotection will require both admin5.strative/procedural controls as well as hardware modifications to current system design.

TABLE OF CONTENTS Section Title 1.0 2.0 3.0 3.1 3.2 3.3 3.4 4 0 5.0 5.1 5.2 5.3 6.0 6.1

. ABSTRACT INTRODUCTION DESIGN CRITERIA SYSTEM DESCRIPTIONS REACTOR COOLANT SYSTEM SHUTDOWN COOLING SYSTEM SAFETY INJECTION SYSTEM VOLUME CONTROL SYSTEM OVERPRESSURIZATION CONTRIBUTIONS ANALYSIS MASS ADDITION MODELS ENERGY ADDITION'ODELS

'ELIEF VALVE MODELS DESIGN BASE INCIDENT INITIALCONDITIONS 6.2 6.3 7.0 7.1 7.2 7.2.1 7.2.2 7.2.3 8.0 9..0 DESIGN BASE INCIDENT MODEL DESCRIPTION IAN PORV SET POINTS CONCEPTUAL SOLUTIONS AND RECOMMENDATIONS SHORT TERM MEASURES LONG TERM MEASURES ADMINISTRATIVECONTROLS HARDWARE MODIFICATIONS ADDITIONALCONSIDERATIONS DESIGN CRITERIA FOR ESTABLISHING LONG TERM SOLUTION IMPLEMENTATION

Section Tit1e 9 X 9.2 9.3 PROCEDURE MODIFICATIONS QUALIFICATION TEST PROGRAM b

CONCLUSIONS REFERENCES Appendix A Appends.x B

Figures and Tables Nomenclature

1.0 INTRODUCTION

h number of PWR overpressurization incidents during low temperature modes of operation have occured in which the 10CFR50 Appendix G

pressure limitations have been exceeded.

The incidents resulted from inadvertent mass/energy inputs such asletdown isolation, safety infection pump starts, charging pump starts, or reactor coolant pump starts.

Unchecked, these mass/energy contributions may result in pressure transients of varying degrees of rapidity.

The purpose of this investigation is to analyze these overpressur-ization initiating events and design features that are germaine to all CE operating NSSS and provide generic recommendations for positive preventive action.

Analytic.cal models are developed to identify. the design base event{s) using postulated worse case initial conditions.

Inherent in the CE NSSS design are mechanisms and procedural controls which may be used to prevent or mitigate the consequences of an incident.

Models depicting these protection capabilities are also incorporated within the design base model to indicate'hether these capabilities alone are sufficient.

Finally, conceptual design fixes, including applicable design criteria, are addressed in addition to estimated implementation schedules.

I

2 0 DESIGN CRITERIA The basic criteria to be applied in determining the adequacy of overpressure protection is that no single equipment failure or operator error shall exceed the operating curve limitations (Ref. 1);

In addition to the initiating mechanism and actions that logically follow, common mode failures, operator action time, IREE and seismic criteria are also considered.

Minimum pressure temperature (MPT) curves for the 2 to LO year period of full power operation plant lifetime are used to.limit maximum allowable pressure.

This Limitation,provides a reasonable conservatism for current plant operation.

The nil-ductility transition temperature

{NDTT), upon which the MPT curves are

based, decreases with additional radiation exposure.

Since metallurgical experience with NDTT is Limited, the MPT curves are formulated with gross conservatism.

Thus, the 10 to 40 year, limitations are considered excessively restrictive as a design criteria.

The ongoing capsule-surveillance program which is analyzing irradiated specimens will indicate the merit of MPT curve conservatisms and the choice of 2 to 10 year curve limitations in future analyses.

3 0 SYSTEM DESCRIPTIONS Contributions of either mass or energy into a closed solid liquid system will result in pressurization of the system.

In the case of CE NSSS reactor coolant system overpressurization may be initiated by components within the RCS, shutdown cooling (SDC) system isolation, inadvertant actuation of the safety in)ection (SI) system, or insufficient letdown in the volume control system.

Descriptions of these systems and the possible overpressurization components follow.

3.I.

REACTOR COOLANT SYSTEM ks shown in Figure 1, the CE reactor coolant system consists of four reactor coolant pumps operating in two loops with one steam generator in each loop.

A pressurizer is attached to the hot leg as is the shutdown cooling suction nozzle(s).

Safety infection nozzles are located on each of the reactor coolant pump discharge legs.

One letdown and one charging line are located on the respective suction and discharge sides of a coolant pump.

Reactor coolant system components which serve as possible overpressurizing inputs are 1) pressurizer

heaters,
2) reactor core decay heat,
3) reactor coolant pumps, and 4) steam generators.

In this investigation energy input by pressurizer

heaters, conserv-atively.assumes all heaters in operation.

For the generic 2560 Nwt class plant full heater input is 1500 KW.

Pressurizer to cold leg AT limitations are 200 F to 400 F for operating CE plants.

When considered, decay heat is a maximum within the temperature ranges of interest (i.e. <300 F) when the RCS enters the shutdown cooling mode, a minimum of ~ hours after shutdown.

Conservative estimates of decay heat rates at initiation of shutdown cooling, after attaining refueling water temperatures (30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, minimum),

and after one week are 1.0, 0.6, and 0.3 percent, respectively.

Reactor coolant pump heat is conservatively considered the thermal equivalent of the pump power rating.

When a reactor coolant pump is started while the steam generators are hot (i.e. secondary inventories are at higher temperatures.than'the reactor vessel cool-ant),

a secondary to primary temperature differential is created and thus heat transfer to the RCS.

This heat input will result in a severe overpressurization of a solid system.

This transient would be terminated at 2500 psia by ASHE Code Class 1 safety valves.

3.2 SHUTDOWN COOLING SYSTEM The shutdown cooling (SDC) system removes residual and decay heat from the reactor following reactor shutdown and maintains a

suitable temperature for refueling and maintenance operations.

0 0

It is designed to cool the RCS from 300 F to the 130 F refueling mode temperature.

Low pressure safety inject pumps are used to provide coolant flow during SDC operation; containment spray pumps are available as.back-up.

Primary coolant circulates from the SDC

nozzles, through the pumps, through the shutdown cooling heat exchangers, to the low pressure safety injection header, and enters the RCS through safety injection nozzles located on each cold leg.

Maximum SDC suction operating pressure is limited by a pressure inter-lock to epproxfmetely 300 pele.'he Lpsz or concelntNnt eprey ponce are uied for SDC.

Overpressurization considerations involve inadvertant isolation of the SDC System.

An isolation terminates core decky-.4ea-removal capabilities.

The resulting heat input would cause pressurization'in a solid liquid reactor coolant system.

3.3 SAFETY INJECTION SYSTEH The safety injection system (SI) is designed to supply emergency boration and core cooling in the unlikely event of a loss-of-coolant incident.

During normal operating conditions safety injection is initiated by a safety injection actuation signal (SIAS) either when the pressurizer pressure drops below 1600 psia or when con-tainment. pressure rises above 4 psig.

When depressurizing the RCS, the SIAS is de-activated before pressure decreases below 1600 psia.

Should a spurious SI signal occur below 1600 psia, system com-ponents which may be activated include two high pressure safety injection (HPSI) pumps, two low-pressure safety injection (LPSI)

pumps, three charging pumps and four pressurized safety injection tanks.

Table 1 summarizes the pertinent design parameters for these components.

Each component may be activated separately or as a group.

Both HPSI and LPSI pump suctions are aligned to the refueling water tank during safety injection.

Delivery curves for these pumps

kre shown in Pigure 2.

The LPSI pumps are also used to supply coolant flow during SDC operation.

The SI tanks are passive com-ponents which discharge borated water to the RCS whenever system pressure drops below the tank operating pressure and the tanks are not isolated.'he charging pumps are reciprocating ~ps which supply the RCS with concentrated boric acid solution through the charging line.'hen ECCS testing can be performed with the RCS either depressurized and open (read off) or above the MPT limiting temperature, inadvertent overpressurization is no longer a concern.

3.4 VOLUME CONTROL SYSTEMS During normal operations the chemical and volume control system (CVCS) automati'cally ad)usts RCS water volume using a signal from

'he level instrumentation located on the pressurizer.

A pressurizer level control program regulates the letdown flow by adjusting the letdown control valve so that the reactor coolant pump bleedoff plus letdown flow matches the input from the operating charging pump.

During solid RCS conditions the pressurizer level control program fully opens the letdown control valve.

Primary system pressure is regulated by ad5usting letdown backpressure control valves to balance the charging pump delivery.

Isolation of the letdown system will result in pressurization of a solid RCS due to input of the charging pump(s).

Data concerning these pumps are given in Table l.

4.0 OVERPRESSURIZATION CONTRIBUTIONS Inadvertent operation or isolation of the systems described in the previous sections result in solid RCS pressurizations of varying degrees.

Not all mass/energy inputs lead to pressuri>>

zation above the operating limits dictated by the MPT curves.

Those that do not overpressurize CE systems are described below and will not be considered in the detailed analyses discussions later in the report.

1.

LPSI pump. input; since shut-off heads (approx.

180 psi, see Figure 2b) are below the most restrictive MPT limits, these pumps are not considered as overpressurizing components.

2.

SI tank discharge; the maximum design pressure for these tanks is 250 psig, below the minimum allowable pressure limit.

3.

Containment spray pumps; these are only used as a backup to LPSI pumps during low pressure operations of the SDC system.

All other previously described inputs are considered contributions to overpressurization; these are tabulated in Table 2.

Results of the transient analyses are compared in Figure 3 which clearly shows the more severe cases.

5.0 ANALYSIS Initiating events applicable to CE plants are analyzed on an individual basis to compare their relative contribution towards

"" " overpressurization'. 'esign parameters used-eocyp&fy"generic systems correspond to 2560 Mwt Class plants.

Values for these parameters are. given in Table 1; and initial conditions for each incident are listed in Table 3.

Equations used for the analyses are listed in Appendix B.

The results of Figure 3 show the worse case transients as a RCP start with hot steam generators.

In addition to this heat input, pressurizer heaters may be operable at the time of the inadvert-ent RCP start.

Also, one-percent decay heat is possible since SDC is isolated by interlocks above 300 psia.

This clearly is the worse combination of inputs and is therefore used as the design basis.

models used to develop the Figure 3 transients are described in the succeeding section.

Also modeled are the relief valve discharge capacities for liquid flow at both normal (2400 psia) and low (415 psia) set pressures.

Models used to depict RCS pressure transients are based on contin-uity and energy conservation principles.

When mass or energy transport from a 'rigid system is less than the input, the system

is insufficiently protected for overpressurization.

In order to protect against excessive transients, the system must be capable of either relieving excess mass and/or energy inventory, or expanding at the system boundaries.

CwA Q f%

Only solid liquid systems are considered in the analysis.

Ecpan-sion of the RCS boundaries simulates a "soft" RCS, analagous to having a pressurizer steam space.

During certain transients a sufficient steam volume may be procedurally available to absorb any mass addition or liquid expansion.

However, the more severe transients involve excessive amounts of mass additions.

A steam space only serves to delay the pressure rise until the volume is filled, creating a solid system and rapid acceleration in pressure.

In addition, a sufficient steam volume may not be possible to maintain during certain periods of operations.

5.1 MASS ADDITION HODELS Solid system mass addition models are based on the conservation of mass and energy principles.

The following assumptions apply.

1.

RCS boundaries are rigid and do not expand under the magnitudes of pressure and temperature encountered.

2.

Pressures increase isothermally.

3.

Mass addition rates are as specified by the pertinent pump delivery curves (e.g. Figures 2a and 2b).

~ ~

4.

Pump starts are instantaneous step functions (actually, HPSI pumps accelerate to full speed within 4 to 8 seconds).

5.

Letdown isolations are instantaneous step functions.

The analyses involve time incremented computations of specific'olume changes as a function of mass input.

System pressures are found as time dependent functions of specific volume and total system enthalpy.

Initial conditions for each model and generic RCS design parameters are tabulated in Table 3 and Table 4, respectively.

The following events require mass addition models to simulate the transients depicted in Figure 3.

1.

Single HPSI pump start 2.

Spurious SI actuation 3.

Charging/letdown imbalance Beside; the mass addition induced pressure excursions, pressurizer heater and/or decay heat inputs may simultaneously occur as a result of normal operating conditions when the initiating event commences.

The resulting pressure transients are assumed additive.

5.2 ENERGY ADDITION MODELS Energy addition models are based on energy conservation with con-stant system mass.

Applicable conservative assumptions are as follows.

1.

RCS boundaries are rigid; metal masses do not act as heat sinks.

2.

Specific volume remains constant with time.

3.

Heat inputs are maximized; i.e. 100 P secondary-primary dT',

I one-percent decay heat, and full power pressurizer heaters.

4.

RCP starts are instantaneous step functions (RCPs attain full speed, linearly, in approx.

10 seconds).

The analyses involve time incremented RCS pressure computations as time varient functions of total system energy content with constant specific volume.

The following events require an energy addition model to simulate the corresponding transients of Figure 3.

Initial conditions for each model and generic RCS design parameters are tabulated in Table 3 and Table 4, respectively.

RCP start with hot steam generators.

2.

SDC Isolation 3.

Pressurizer Heater Actuation

5. 3 RELIEF VALVE MODELS Discharge capabilities of relief valves are modeled to indicate their effect upon overpressurization.

Using the Bernoulli equation and continuity principles, the liquid discharge rate is modeled as an orifice discharge.

Since the overpressure protection occurs

during liquid conditions, discharge coefficients are used conserv-atively as 0.60, assuadng liquid flow.

Valve discharge capabilities are pressure dependent relative to the rated capacity at the valve set point; i.e. as RCS pressure increases the valve discharge increases as function of the square-root ratio to the set pressure.

12

6.0 DESIGN BASE INCIDENT The most severe pressure transients are shown in Figure 3 as 1) a RCP start with hot steam generators, and 2) a spurious SI signal which includes two HPSI pumps and three charging pumps

{as discussed.

in Section 4.0, LPSI pumps and SI tanks are not considered).

For the design base incident, both SI trains are assumed administrativel>

isolated below 200 F.

A requirement of sufficient pressurizer 0

steam volume for temperatures above 200 F is assumed before activating the first HPSI pump; the second pump is assumed admin-

.istratevely isolated below 260'F.

In view of these assumptions, the transient resulting from the. RCP start when the system.is water solid is considered the design base.

These assumptions are dis-cussed later as conceptual administrative fixes.

6 1 INITIALCONDITIONS Morse case design base initial conditions are 300 psia RCS pressure, saturated temperature in the pressurizer, heaters at full power, and a one-percent decay heat addition rate.

Results using these inputs are shown in Figure 4, Also shown in the transient model is the effect of the power operated relief valves (PORV's) when they open at the current set pressure of 2400 psia.

Once these valves open, the transient is quickly terminated.

The valve discharge coefficient was conservatively assumed as 0.60 since PORV's have not; to date, been rated for liquid service.

ASME Code Class 1 safety valves protect the RCS at 2500 psia.

13

6.2 DESIGN BASE INCIDENT MODEL DESCRIPTION The design base analysis simulates a closed water solid RCS with time varient heat addit'ion from each steam generator; core decay and pressurizer heater input is condidered on a bulk basis to the system.

Steam generator heat input is a function of 1) the trans-kent secondary water and metal mass heat content located within the downcomer section of the generator,

2) the t'ransient average tube primary temperature, and 3) the volume flow rates through each generator.

Overall heat transfer coefficients are considered flow dependent; hence, different coefficients for each steam generator.

The convective coefficients outside the generator tubes are calcula-ted as in Reference 2 for a batch cooling model.

Coefficients are calculated assuming initial steam generator and tube flow conditions and are assumed constant with time.

A detailed tabu-lation of initial conditions and system parameters is shown in Table 5.

6.3 LOW PORV SET POINTS Shown in Figure 5 are the resulting transients when PORVs are in-corporated within the design base model, set at 400 psig.

The valve models assume discharge areas of 1.29 in per valve, discharge 2

coefficients of 0.60, back pressures of 50 psig, and maximized pressurizer temperatures of 420 F (saturated temperature a transient 0

initial pressure of 300 psig).

Valve relieving capacity is pressure

dependent; i.e. as RCS pressure increases, the discharge rate also increases (as discussed in Section 5.3)

A comparison of Figure 5

results with minimum allowable pressures (from 2 to 10 year MPT curves, Figure 6) indicates sufficient protection is provided with o

two valves for cold leg temperatures above 160 P.

15

7,0 CONCEPTUAL SOLUTIONS AND RECOMMENDATIONS Discussions concerning possible solutions are categorized below.

7 1 SHORT TERM MEASURES Solutions which can be.implemented immediately, requiring only administrative/procedural action, are as,fall@vs.,~se measures are presently being pursued.

I.

Procedural controls to avoid water solid conditions by main-taining a pressurizer steam space for as low a temperature as possible.

'I 2.

Administrative isolation of non-~ssmtia1 womponents Mich possible overpressurization contributors (e. g. HPSI pumps, RCP s>

pressurizer

heaters, charging pumps).

3.

Briefing of operators to increase awareness of potential problems.

4.

Single set-point alarms beneath MPT limitations to alert operators of a pressure excursion.

7.2 LONG TERM MEASURES Two possible means of physically controlling pressure transients exist:

1) release of excess system mass and energy, and 2) providing a compressible cushion by either generating a steam bubble or by adding a noncondensible (e.g. nitrogen) bubble to the system.

Each of these solutions has limitations'.

Liquid relief valves may be incorporated in the system design during low pressure-temperature operation.

However, practical limits of a

maximum obtainable relief rate exist{i.e. size, number of 16

valves, and back pressure flow limitations).

In addition, con-taminated discharges result and should be contained.

During transients for which liquid relief is impractical, a com-

"""""'""-"-"'re'ssiklepressurizer bubble is-.attractive:.

Sudden w'oolant; ~ansi+as" or inventory increases are almost instantaneously controlled with sufficient volume.

Shortcomings include volume magnitudes which are needed to handle the entire transient.

Non-condensible volumes should be avoided.

Problems which may be encountered when gaseous pressurizer volumes are employed include 1) venting,

2) disposal, and 3)

RCS chemistry effects.

Long term solutions to overpressurization must incorporate both fore-mentioned means of protection.

Specific solutions can only be realized after an analysis for each specific plant is completed.

Recommended long term solutions are discussed in the following sections.

7 2.1 ADMINISTRATIVECONTROLS Recommended long term administrative/procedural controls are as follows:

1)

HPSI pumps should be isolated below 200'P (indicated cold leg temperature)

~

4 2)

Befoxe electrically activating the first HPSI pump, a minimum steam volume is necessary to absorb mass input resulting from spurious SI 0

actuation.

The second HPSI pump should be activated above 260 F.

This temperature assures MPT limits above pump shutoff head.

17

Technical Specifications are satisfied since both HPSI pumps 0

need not be operable below 300 F.

A 3.

Reactor coolant pump operation may be administratively controlled

'Eor pressures

-below -300 psia and whenwwteamispace does.-.nat.,

exist in the pressurizer.

Pump sweeps of solid systems may be necessary; protection for this case is discussed in Section 7.2.2.

3 4.

A minimum steam volume (approx.

300 ft ) is recommended before operating RCP's.

This volume will absorb the liquid expansion should RCP/steam generator heat input be added to the primary coolant during heat-up.

5.

Administratively ensure that the AT between the steam generators shell side and RCS is minimuzed.

7 2 2 HARDWARE MODIFICATIONS Measures requiring physical modifications to the RCS include the in-stallation of dual set-point relief valves to provide protection.

Both mechanical (spring-loaded) and power operated relief valves (PORV's) are available.

Each type of valve has limitations.

Spring-loaded relief valves are certified (American Petroleum Institute) for liquid service.

However, the valves are not presently of seismic class.

Also, spring-loaded valve set-points are not variable..

Power operated relief valves (PORVs) have not to date been certified for liquid service conditions.

These valves are seismically rated, and may have variable set-points.

A test program to qualify PORV operability and performance furing liquid service will be conducted.

18

Included in the design of current CE operating plants are PORVs set at 2400 psia. If qualified for liquid service they could be used for overpressure protection with low pressure set-points.

The design base model analysis (Section 6.3) indicates the current PORVs will provide sufficient protection.

Use of these, or equivalent low set-point valves would provide the protection against a possible RCP sweep overpressurization.

If current PORVs were used an additional auxiliary controller for low set-points would be required.

The following operations would be necessary to provide the RCS with overpressure protection when utilizing cuxrent PORV's.

A suggested low set-point pressure is 400 ps l.

Por plant cooldown from hot standby, an overpressure protection alarm occurs at a pressurizer pressure of 400 psia to alert the operator that PORV's need to be reset to their low set-point and unisolated, respectively.

Prior to solid water plant operation when pressurizer pressure is approximately 350 psia the PORV's are reset and unisolated.

2.

For plant startup from cold shutdown to hot standby, at a pressurizer pressure of approximately 350 psia, and with a bubble formed, the PORV's are isolated and reset to the normal value of 2400 psia.

Once reset the valve may be unisolated 19

Were a pressure transient to develop, the following events would take place to prevent the reactor vessel from exceeding design MPT limits.

l.

An overpressurizati'on alarm at a suggested pzessure of 350 psia warns the operator of a pressure surge and an imminent relief valve opening at 415 psia pressurizer pressure.

2.

PORV's open at approximately 415 psia, providing the plant with total overpressure protection.

When the transient is reduced to PORV blowdown pressure the valves close.

7'.3 ADDITIONAL CONSIDERATIONS Disposal of discharged primary coolant is a ma)or factor to consider.

in the overall solution.

The advantage of administratively controlled electrical isolation and steam volume cushion solution is the minimi-sation of primary coolant dischazge from the RCS boundaries.

In cases where coolant discharges cannot be avoided (e.g. after the steam volume is filled, or when RCS is swept by RCP when solid), the following precautionary measures should be considered.

l.

Avoid excessive discharge piping backpressure build-up which may restrict discharge rate and possibly eliminate the use of exist-ing relief valves.

2.

Contain the discharge or dizect it to a confined disposal site (eg. the containment sump).

Alternate vessels other than the pressurizer quench tank should be considered since this tank was not designed to handle massive or prolonged discharges.

Reaction 20

forces on the discharge piping should also be considered for liquid/two-phase discharges.

Locations which may be 'considered for placement of liquid relieving valves should not irivolve a hydrostatic test of the RCS, i.e. relief valve(s) should be added

'on the "outside" of an isolation valve so the connection may be hydro-tested awhile isolated from the RCS.

Space limitations may effect placement of relief or isolation valves on present pressurizer PORV lines.

Additional locations for consid-eration are on isolable letdown lines and the RCS drain system.

"Installation of permanent pressure-temperature records would also be beneficial in determining the severity of future events.

21

8.0 DESIGN CRITERIA FOR ESTABLISHING LONG TERM SOLUTION The design considerations listed here in will be evaluated for each plant specific long term overpressurization solution design and

~ "" --'" " ---"-".procedure.

Specific designs will specify 4heiapplMability of each " ~

or combinations of the following:

l.

Operator Action Credit for operator action will not be taken until 10 minutes after the overpressurization initiating event.

Earlier corrective action can be assumed if an alarm, dedicated for this service, is provided as part of the design.

Set-points for the alarm(s) indicated for'this service ~ be determined by the design and hardware used to mitigate overpressurization.

Since most initiating events result in overpressurization in less than one minute, insufficient time exists for the operator to prevent overpressurization once initiated.

2.

Single Failure-The design basis for any proposed design, either set-points or hardware, shall be such that a single faQ.ure will not precipitate a LOCA when the system is in a passive, non-operational mode.

Testability will be incorporated into the design logic to verify that hardware, dedicated to prevent overpressurization, is operable.

Guidelines will include testing function of position indication of valves and actuation systems to insure valve operability.

3.

Common Mode Failure Common mode failure will be considered for any design dedicated to prevent overpressurization.

Common mode faQ.ure will be considered such that the single failure that precipitated the initiating overpressurization event will 22

not disable the overpressure protection design.

Typical events could be loss of off-site power or loss of instrument air supply.

4.

IREE Criteria - The electricaL design will consider single failure as stated in (2) above.

Isolation criteria consistent with IEEE279 will be used to preclude the possibil.ity.of a LOCA during plant operation at power.

Since a single failure causes the

~initiating.event only, a second failure will not be part of the

'entral design logic.

However, electrical separation will be considered, when required, to satisfy common mode failure criteria discussed in (3) above.

5.

Seismic Category - Consistant with thefundamental design objective of preventing another potential LOCA pathway, isolation of dedicated hardware will meet seismic Category I criteria when it forms part of the Reactor Coolant System pressure boundary.

Equipment specifically designed to prevent overpressurization will not be designed to Seismic Category I.

Examples of such equipment are mechanical or power operated relief valves.

Seismic requirements will be addressed during common mode failure considerations such as a seismic event precipitating a loss of off-site power or instrument air supply.

9 0 IMPLEKWZATION h detailed implementation program will be provided with each operating plant specific report.

The ob)ective of this part of the report is to define in general what the critical path items are that comply with recommendations made here in as follows.

9 1 PROCEDURE MODIFICATIONS Changes to procedures are readily implemented subsequent to completion and approval of operating plant specific analysis.

Many procedure changes 'are presently being made as part of the operating plant interim measures.

It is expected that the approved procedure changes would be available to operating units within 2 to 3 months of.

plant specific analysis approval.

9.2 UALIFICATIONTEST PROGRAM Should this pathway be pursued as a result of specific analysis, the program must demonstrate that existing and/or required hardware will:

1.

Operate within the thermal hydraulic conditions analyzed.

2.

Satisfactorily pass the liquid or 2-phase mixture as analyzed.

An investigation regarding the feasibility of such a program to be conducted by Combustion Engineering or a capable independent testing laboratory has begun.

A program ob5ective is completion prior to June 1, 1977.

9.3 HARDWARE PROCUREMENT Any system modifications must be done as a two part schedule; part one being procurement and part two installation.

Should additional

hardware be required, availability subsequent to completion of operating plant specific analysis is in general as follows:

AVAILABILITY Recorders and Alarms Rotor Operators g 1/2" )

Air Operators g, 1/2" )

Air Accumulators (non seismic)

Air Accumulators (seismic N2)

Pipi g 0 1/2")

Electrical Hardware

" Instrumentation Indicators Transmitter Class 1)

Transmitter tPon Class 1 )

Power Operated Relief Valves Nechanical Relief Valves Isolation Valves 6 months 18 months min.

18 months min.

18 months min.

Presently being qualified. Unknown availability 12 months min.

6 months 6 months 24 months 9 months 15 - 18 months 15 - 18 months 18 months min.

Installation schedules will be developed after plant specific.

analyses are completed.

25

10.0 CONCLUSION

S Based on the analyses,

results, and recommendations discussed in the preceeding
sections, the following conclusions are presented.

l.

In view of their conservative origin, coupled with the ongoing irradiated material surveilance program, pressure limits corresponding to the 2 to 10 year full power operating MPT curves are used as the basis for exceeding operating limits.

2.

The most severe transient which may occur during a water solid condition is the RCP start/hot steam generator/decay heat/pressur-izer heater input mode1.

This case is the design basis for protection.

3.

Pressurizer heater actuations, charging/letdown imbalances, and SDC are considered minor incidents contributing to overpressurization.

Design base protection means are sufficient to control these events.

4.

Administrative isolation of HPSI yumps below 200'F eliminates a

0 spurious SI actuation from consideration below 200 F.

5.

The most positive protection against overpressurization is consid-ered the maintenance of a pressurizer steam volume to as low a temperature as possible.

6.

Electrical isolation of non-essential components

~

is also a

viable means of protection, especially at low temperatures where pressure limits are lowest.

Both HPSI pumps 26'

should be isolated below 200 F (indicated average temperature).

0 Above. 200 F, a minimum pressurizer steam volume (size dependent upon specific plant analysis) is recommended.

The second HPSI pupp should not be activated below 260 F.

0 7.

Relief valves should be incorporated into system designs to pro-vide protection during conditions conducive to overpressuxization (i.e. low tempexature, water solid system).

These valves may'e either mechanical or qualified power operated relief valves, depending on the desired operability.

8. If power operated relief valves are desired, operability and performance qualifying tests for liquid service are necessary.

9.

Based upon a conservative model for liquid discharge capability PORVs used in operating CE plants will provide sufficient pro-tection for cold leg temperatures above 160 F when set at a low set point of 400 psig.

Based on this generic indication, a

minimum temperature for operation of RCPs during water solid conditions would be required.

10.

Relief valve discharge piping must be considered for flow limiting backp'ressure'build-up.

11.

Availability of hardware typically ranges from 6 to 18 months mini-mum.

12.

Administrative measures can be taken to insure that the hT between the steam generator shell side and RCS is minimized.

27

1 NRC Letter, Docket No. 50-336, to Utilities dated August 11, 1976 2

Kern, D.Q. Process Heat Transfer, McGraw-HiI1 Book Co.,

New York, 1960 3

Kreith, F. Heat Transfer, International Textbook Co., Scranton, la.,

1969 4

2560 MRT Class Plant Technical Specification 5

2560 HWT Class Plant Operating Procedures'.

OP-l, Rev.

2 (B G & E)

OP-5, Rev.

2 (B G 6 E)

2201, Rev.

3 (NEU) 28

'PPENDIX A FIGURES AND TABLES Figure 1 Figure 2A Figure 2B Figure 3

Figure 4 Figure 5

~

Figure 6

Reactor Coolant System HPSI Delivery Curves LPSI Delivery Curve Overpressurization Transient Design Base Transient Design Base Model, Low Valve Set-points 2 to 10 Year MPT Curve Table 1 Table 2

Table 3

Table 4 Table 5

Component Date Summary Initiating Events Initial Conditions Generic RCS Parameters Design Hodel Parameters

1 I

~

I I

I~5)c,AGIO ppEss 4.rz Iggg u Gnc T~SN C H]%CG-IlV6-L. IA'8

('c'c o)

I,F Pl: 8~I.T'D CO55%

S~un

~f1=~A GF'H~< f!Tgs(

~GH&MA7 I

I

~ ~ 1 lf.'sicr~g

~C'gpss M~]CcA~

HMTbo~4 c~w6-wr~E Ph c.vo COOINNI ag 1.5 CRI144W5.

LlrVf (cv i3

~yama)

L]AIR'c~c.~)

1 C

Ft6o~

zW 'gPzcwa Two puAP O'Pfz aegiveey c.e erg p>~as goo 6'oo

)Boo FLOW ~

4z g GP&

31

C']eo ge zg:

rvPI ebs z.isr

- rwo porn e P8 l i V @RE C.VR.VE ggki

/

/w f/>

]yy

)o y

ao w w W W +S'o 45 M 45

'70 78 FLo~ ~

gc,s x )co

~ 6D+

I

lt'Rcp sew'Hd7$ 8 K

/CD goo sz>C ZroLAT/Oh)

~

g glQER HSAW~

IO 20 Tone, gza~Nos 33

tOCO A.

Lb

)200

/OOO 8CP $7AAT 4I/H07 SGs PSGSSvgg'hER HEw~AS

&PA.7 PCP p~

/de PORVs SE7-h7 X~ F5/~

7 HR,dh7 AR 84 i'. 'LQ OlSCH~Q5 C56 pp] c,]qm~-

GAW PRCCSvgc a gyp ps(g

FI SPRAT 4-:

>k>ICN jpR$5 OfdbEC LeW L4VF SerPOIN7 Pr Wad PP&

.6 lu A.

fao Tw b,Vh~ygS IOO Vac,Ve rHaoAl-A~A

=

I.Z9 IR DISCH)ffPSE CoEFFlCLEQ7~ CO =

C 60 8am P~SSSCRE

~

mC. eSIQ

~lBPERR Tug,F

=

+2b'P'20 7RrWrCIEN7 ECAPSFD TI/Y75' SEGOlJbS'5

Fl6URE Co ta!

a:f It ~

~ ~I

I MINIMUMPRESSURE TEMPERATURE FOR::.

CRITICALOPERATION OF CORE

~~ NONCRITICALOPERATION OF CORE

~ M

~ ~

~

~

~

~

M at

~

~

~

~

~ ~

~ ~

~ ~

..j,... !tttl!t.

4 na ~

tt'4 tt>>

~

~

~ ~ ~

~

~ ~ ~

~ ~

~

LOWEST SERVICE
TEMPERATURE

~ ~ ~

~

~ ~

~ ~

~ ~ ~

4

~ ~

SYSTEM HYDR I:it :::: at:4

~ 4 I

~

~ ~ 4M

~

Ma 4

~

~~

~ 4

~

~

~

HEATUP 4 "-M:t-.j:::f g='DDLDowN-:rt=:

~fa ~

~ ~

~I M

Ma

~ M ~

\\

~

~ ~

at>>

~ 4

~4

~ ~

~ ~ >>

~

~

~M I

HEATUP'OOLDOWN'

~4

~ 4 M4

~ 44 ~

~ ~

~

~ 4 ~

~

~

~ ~

~

~ ~

~ 4

~J

~ ~

i

~

~ ~

H~

tc

!L' 600

~

~ ~ ~

4 ~ ~

~ t

\\

~ ~

M>>I I

~

~

~

4

~M

~

~

4

~

~ ~

~ ~

~

4

~

8

~ ~

~ ~

4

~

~

0

't200 M

~

~

tta ~

M

~

~

~

~ ~

~

~

~

4

~

~ ~ ~ 4 E MATERIAL EL BELTLIN ESS INITIALRTNDT 8

F

'rr:::

j NOTE 2-REACTOR VESSEL BELTLINEMATERIAL 10 YEAR RT got SHIFT ~ I38

.:.-: ! NOTE 3 <<REMAINING PRESSURE BOUNDARY MAXIMUMRT goy SO F

NOTE 1 REACTOR V

~ I i!iii t ta.a

~

~

~ ~ ~

~ I

~ 4 t>>;

~ ~

~

~

~

~ I

~ ~

~ ~ ~

'AXIMUMPRESSURE "

'-: FOR SDC OPERATION

~ ~ ' ':

~\\ ~

~

~

~ ~

4 ~

t 4't

~ ~

~

~

0 0

200 300 400

$00 INDICATEDREACTOR COOLANTTEMPERATURE Tc.

F Reactor Coolant System Pressure Temperature Limitations for 2 to 10 Years of Full Operation

~ ~

ThBLE 1!

Co onent Data Sumaa

~Pum Data

~Te Desim Pressure

~Ca 'citi Shutoff Head HPSI LPSI Charging Pump Containment Spray Pumps Seven Stage Horizontal Centrifugal Single Stage Horizontal Centrifugal Positive Displacement Single State Horizontal Centrifugal 1750 psig 500 psig 2735 prig 500 psig See Pig.

2a See Fig.

2b 44 gpm same as LPSI 2930 ft.

(1270 psia 8 60 P) 420 ft.

(180 psia 8 60 P) 3010 psig 460 ft.

(215 psia 8 60 F)

SI Tank Data "

Total Volume Water Volume Design Pressure Operating Pressure 2000 ft.

1113 (min) ft.3 250 psig 200 psig

Initiating Events Considered AppU.cable to Operating CE Plants 1.

Pressurizer Heater Actuation 2.

Shutdown Cooling Isolation 3.

Charging/Letdown Imbalance 4.

HPSI Pump Start 5.

Spurious SI Signal 6.

RCP Start with Hot Steam Generators 38

TABLE 3i Initial Conditions Event*

Pressure Tem erature Mass Ener In ut Pressurizer Heater Actuation Pres 300 psia T

~ 160oF ave 1500 KW SDC Isolation Pres

~ 250 psia Tc 200 F 25.6 Mwt (Decay Heat)

Charging/Letdown Imbalance Pres

~ 300 psia T

~ 160 F ave i 44 gpm/pump One and Two Pump Inputs HPSI Pump Start Pres

~ 300 psia T

~ 200oF ave per Fig 2a Deliver Curve

.SI Actuation Pres

~ 300 psia T

~ 200 F ave 2HPSI Pumps 3 Charging Pumps RCP'Start w/Hot Steam Generator Pres 300 psia T

<100 F sdc T

~ 200oF sec Steam Generator Heat Transfer RCS is water solid in all cases

TABLE 4:

Generic RCS Parameters immanent Number Volume (ft er com onent)

Reactor Vessel Steam Generator Reactor Coolant Pump Pressurizer Hot Leg Suction Leg Discharge Leg Surge Line 2

4652 1683 112 1500 140 112 80 32 Pull Power Pressurizer Heater Capacity Design Core Thermal Power Reactor Coolant Pump Heat 1500 KW 2560 MN 5.0 HV/pump Reactor Coolant Pump Capacity One-Pump Pour-Pump 140,000 gpm 81,200 gpm 40

TABLE 5:

Desi Base Model Parameters Event:

RCP start vitb hot steam generators Seconda Ener Contributions:

One-percent Decay Heat Pressurizer Heaters RCP Heat 25.6 MR 1500 ER Steam Generator Parameters:

Number Type Number of Tubes Tube Outside Diameter Tube Wall Thickness Heat Transfer Area Coolant Volume Vertical U-Tube 8519 0.750 in.

0.05 in.

90,232 ft 1683 ft Dry Weight Flooded Weight 1$ 004$ 000 lb.

1,526,700 lb Seconds Masses Considered in Model:

Secondary metal (inside downcomer)

Secondary water (inside downcomer) 350,000 lb 1505000 lb.

(continued)

TABLE 5 (continued)

Sin le Pu eration Flow-s lit:

111,148 Epm Steam Generator 99,772 Epm RCP 1B 40,00 gSPm 28,844 RCP 1A Reactor Vessel 5,685 Epm 4 5 >685

> Epm RCP 2B 11,371 Epm Steam Generator Overall Heat Transfe'r Coefficients:

Steam Generator No.

1 Steam Generator No. 2 264 Btu/hr ft F

160 Btu/hr ft F

Calculated via methods of Ref.

2 and Ref.

3 (See AppendixB )

42

ArPZHDIX B Letter S

bols

. C area p f't2 discharge coefficient specific heat diameter, ft.

'PSI diameter, in.

high pressures safety injectiqq <; -. "...->>.

h heat transfer coefficient, Btu/0 z) (ft2) (oF) thermal conductivity., Btu/(hr) (ft2)(oP/f )

LPSI tube length, ft.

low pressure safety infection

Pressure, psia PORV power operated relief valve Pr Prandtl number volume flow rate, ft /sec.

3 thermal resistance, (hr) (ft ) ( F) /Btu 2

0 Reynold number zeactor coolant pump RCS SI SIAS reactor coolant system shutdown, cooling safety injection safety in)ection actuation signal

St, Stanton number U-temperature, F

0 temperature difference, F

overall heat transfer coefficiyqt Btu/.(hr)(ft )( P)

Creek Letters coefficient of thermal expansion, 1/ F density, ibm/ft3 viscosity, centipoises x 2. 42 ~ ibm/(ft) (hr)

Subscri ts rcs backpressure evaluated at film temperature inside property primary outside property 1

reactor coolant system conditions set secondary set-pressure condition throat property 44

APPEHDIX B Relief Valve Plow Rates:

Qr Pres - Pb set b/~

Qr ~ CDA P

- Pb/P Overall Coefficients of Heat Transfer:

1 o+Ro~Rk+ i (o i

+ AoAi) lhi)

(Reference 3) h

~ 116 0

kf3P 2Cf B

hT d

0.25 (Reference 2) for R 1208000 hi St (Ds/Dp) f(Re Pr)

(kp/9)

Re Pr (pp/p )

p (Reference 3) n ~ 0.36 for liquid heating for R 120,000, R

10,000 e

hi 0.023 (3600 V

)

D '

(u/o)

(Reference 3)

R0

~ 0,001 hr ft2 P/Btu Ri ~ 0.001 hr ft2 P/Btu 1

~kL (Reference 3)

I I

)

Ci,.

~)