Proposed Change to Tech Spec 4.6.2.2.d,modifying Limit on Surveillance Flow Test of Sodium Hydroxide from Containment Spray Additive Tank
ML18085A383
Person / Time
Site: Salem PSEG icon.png
Issue date: 12/12/1980
From:
Public Service Enterprise Group
To:
Shared Package
ML18085A381 List:
References
NUDOCS 8012190230
Download: ML18085A383 (1)


Text

....,,_.... -*-"

CONTAINMENT SYSTEMS SPRAY ADDITIVE SYSTEM LIMITING CONDITION FOR OPERATION 3.6.2.2 The spray additive system shall be OPERABLE with:

a.

A spray additive tank containing a volume of at least 2000 gallons of not less than 30 percent by weight NaOH solution, and

b.

Two spray additive eductors each capable of adding NaOH solution from the chemical additive tank to a containment spray system pump flow.

APPLICABILITY:

MODES 1, 2, 3 and 4.

ACTION:

With the spray additive system inoperable, restore the system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the spray additive system to OPERABLE status within the*

next 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.2.2 The spray additive system shall be demonstrated OPERABLE:

a.

At least once per 31 days also by verifying that each valve (manual, power operated or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

b.

At least once per 6 months by:

1.

Verifying the solution level in the tank, and

2.

Verifying the concentration of the NaOH solution by chemical analysis.

c.

At least once per 18 months -during shutdown, by verifying that each automatic valve in the flow path actuates to its correct position on a Containment High-High pressure test signal.

d.

At least once per 5 years by verifying a NaOH solution flow rate ot;7.9 _!_ 8:7 gpm from the spray additive tank through 12..0t3.0f" sample valve 1CS61 with the spray additive tank at 2.5 + 0.5 psig.

SALEM - UNIT 1 80121 190230 3/4 6-10