05000311/LER-1980-009, Forwards LER 80-009/03L-0

From kanterella
(Redirected from ML18082A882)
Jump to navigation Jump to search
Forwards LER 80-009/03L-0
ML18082A882
Person / Time
Site: Salem 
Issue date: 08/08/1980
From: Librizzi F
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18082A883 List:
References
NUDOCS 8008140326
Download: ML18082A882 (3)


LER-1980-009, Forwards LER 80-009/03L-0
Event date:
Report date:
3111980009R00 - NRC Website

text

    • -....'----r'---'-*-*~:: _._ ~

.. *-.t. *......,.~

(j PS~G Public Service Electric and Gas Company 80 Park Place Newark. N.J. 07101 Phone 201.430-7000 Mr. Boyce H. Grier Director of *USNRC Augu!it 8, 1980 Off ice of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear.Mr. Grier:

LICENSE NO. DPR-75 DOCKET NO. 50-311 REPORTABLE OCCURRENCE 80-09/03L Pursuant to the requirements of Salem Generating Station Unit No. 2 Technical Sp~cifications, Section 6.9.1, we are submitting Licensee Event Report for Reportable Occurrence 80-09/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

?P t?..1t4gs F. P. Librizzi General Manager -

Electric Production CC:

Director, Office of Inspection and Enforcement (30 copies)

Director, Office of Management Information and Program Control (3 copies)

,@0081403~6 95*2001 1200M) 2-78 I

I I

,\\.:" ** _..:,.._

I **.*.*,..:....:-':.-J..- * -- --****--- **

Report Number:

' Report Date:

Occurrence Date:

Facility:

80-09/03L 8/8/80 July 9, 1980 Salem Generating Station - Unit 2 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Steam Generator Flow and Pressure Instruments Inoperable CONDITIONS PRIOR TO OCCURRENCE:

Mode 3, Prior to Initial Criticality DESCRIPTION OF OCCURRENCE:

During a Reactor Coolant System heatup, 21 Steam Generator Steam Flow Channel II, 22 Steam Generator Steam Flow Channel I, 23 Steam Generator Steam Flow Channel I and 23 Steam Generator Pressure Channel II were declared inoperable at 1220 when they failed to respond properly.

Action Statement 3.3.2.1 was entered which requires with Engineered Safety Features Actuation System instru-mentation channel inoperable, operation may proceed until the next required Channel Functional Test, provided the inoperable channel is placed in the tripped condition within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

The bistables for the affected channels were tripped within the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

Procedural inadequacy, in that the Main Steam System did not need to be lined up by procedure until the Turbine Generator was to be rolled.

ANALYSIS OF OCCURRENCE:

In order to ensure all protection channels are available, the Main Steam System should be in the proper valve lineup prior to com-mencipg *the plant heatup.

CORRECTIVE ACTION

The isolation valve was opened to place the instruments into an operable condition and the action statement terminated at 1926.

LER 80-09-03L Qn July 10, 1980, a complete valve lineup of the Main Stearn System was completed.

The overall operating procedure has been changed to require the Main Steam System to be in operation prior to commencing the plant heatup.

FAILURE DATA:

Not Applicable Prepared by~~M_.~J_.~M_u~r_p_h_y~~~~~

,.4/_Q* 1,,,L;L_

Manager -

Sal.¢ffi aer;erating Station SORC Meeting No. ~~~~~~~~~~-

58-80