ML18082A811
| ML18082A811 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 05/27/1980 |
| From: | Brunner E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Schneider F Public Service Enterprise Group |
| Shared Package | |
| ML18082A810 | List: |
| References | |
| NUDOCS 8007310118 | |
| Download: ML18082A811 (2) | |
See also: IR 05000272/1980010
Text
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION I
631 PARK AVENUE
KING OF PRUSSIA, PENNSYLVANIA 19406
MAY c7 \\960
Docket No. 50-272
Public Service Electric and Gas Company
ATTN:
Mr. F. W. Schneider
Vice President - Production
80 Park Place
Newark, New Jersey 07101
Gentlemen:
Subject:
Inspection No. 50-272/80-10
This refers to the inspection conducted by Mr. W. Rekito of this office on
April 22-25, 1980 at the Salem Nuclear Generating Station, Unit No. 1,
Salem, New Jersey of activities authorized by NRC License No. DPR-70 and to
the discussions of our findings held by Mr. Rekito with Mr. H. Midura of
your staff at the conclusion of the inspection, and to a subsequent telephone
discussion between Mr. W. Rekito and Mr; J. Zupko on April 25, 1980.
Areas examined during thfs inspection are described in the Office of Inspection
and Enforcement Inspection Report Which is enclosed with this letter.
Within these areas, the inspection consisted of se.lective examinations of
procedures and representative records, interviews* with personnel, observations
and independent calculations by the inspector.
Based on.the. results of this inspection,.ft appears that one of your activities
was not conducted in full compliance with NRC requirements, as set forth in
the Notice of Violation, enclosed herewith as Appendix A.
This item of
noncompliance has been categorized into the l~vels as described in our
correspondence to you dated December 31. 1974.
This notice is sent to you
pursuant to the provisions of Section 2.201 of the NRC's "Rules of Practice,
11
Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you
to submit to this office, w.ithin twenty (20) days of your receipt of this
notice, a written statement or explanation in reply including:
(1) corrective
steps which have been taken by you and the results achieved;. {2) corrective
steps which will *be taken to avoid further items of noncompliance; and (3)
the date when full compliance will be achieved.
In accordance. with Section 2.790 of the NRC 1s "Rules of Practice,
11 Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and the enclosures
will be placed in the NRC's Public Document Room.
If this report contains
any information that you (or your contractor) believe to be proprietary, it
is necessary that you make a written application within 20 days to this
office to withhold such information from public disclosure. Any such application
must be accompanied by an affidavit executed by the owner of the information,
which identifies the document or part sought to be withheld, and which
contains a statement of reasons which addresses with specificity the items
MAY 2 7 1980
Public Service El~ctric and Gas Company
2
which will be considered by the Commission as listed in subparagraph (b)(4)
of Section 2.790.
The tnformation sought to be withheld shall be incorporated
as far as possible into a separate part of the affidavit. If we do not
hear from you in this regard within the specified period,. the report will
be placed in the Public Document Room.
Shaul d you have any questions concerning this inspection; we will be pl eased
to discuss them with you.
Enclosures:
1.
Appendix A, Notice of Violation
Sincerely,
~&C
Reactor Operations and Nuclear
Support Branch
2.
Office of Inspection and Enforcement Inspection
Report Number 50-272/80-10
cc w/encls:
F. P. Librizzi, General Manager - Electric Production
E. N. Schwalje, Manager - Quality Assurance
R. L. Mittl, General Manager - Licensing and Environment
H. J. Midura, Manager - Salem Generating Station