ML18079A348

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-06A.Special Task Force Established to Coordinate Review & Understanding of TMI-2 Event.Appropriate Procedural Revisions Being Prepared. Supplemental Response Will Be Made Prior to 790531
ML18079A348
Person / Time
Site: Salem  
Issue date: 04/25/1979
From: Schneider F
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 7906020193
Download: ML18079A348 (23)


Text

~--~*--_....

Frederick W. Schneider Vice President Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 201/430-7373 Production Mr. Boyce H. Grier Director of USNRC Off ice of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

RESPONSE TO USNRC BULLETIN 79-06A SALEM UNITS 1 AND 2 INTRODUCTION April 25, 1979 PSE&G and Westinghouse Corp. have recently begun an in-depth study of the events and* circumstances associated with the Three Mile Island incident as they relate to the Salem design and operating procedures.

Preliminary results have been achieved in most of the areas covered by Bulletin 79-06A.

The scope of this study and the bulletin, however, demand considerably more time than the 10 days permitted by the bulletin; the responses enclosed reflect the cur-rent status of our efforts to satisfactorily address all of the current concerns.

The enclosed responses which mention review currently underway are expected to be completed by the end of May, 1979.

Most of the re-views will be completed prior to that date.

Any resulting procedural modifications or design changes will be completed in accordance with existing controls over those activities and may require additional time for equipment procurement, design activities, and management review.

It should be noted that Salem Unit No. l is currently shutdown for refueling and is not expected to return to service until mid-June, 1979.

Salem Unit No. 2 is currently waiting for an operating license and it is expected that all applicable procedural reviews and re-visions will be completed prior to departure from zero-power physics testing.

Mr. Boyce H. Grier 2 -

4-25-79 ITEM 1 A.

PSE&G has organized a special task force with representa-tives of the Electric Production Department and Engineer-ing Department.

This task force has been assigned the duty to coordinate all activities pertinent to the Com-pany's review and understanding of the TMI event.

Any changes to station documents and design changes re-sulting from this review shall receive task force review prior to implementation.

The Task Force has participated in presentations made by Westinghouse which were based on a Westinghouse evaluation of the event.

PSE&G will continue to work with Westing-house, and independently, to fully comprehend the TMI event and to systematically analyze the Salem Station for possible corrective actions.

B.

Plans are being formulated to instruct our operating per-sonnel regarding the decision making process* to be* used prior ta* terminating automatically° initiated protective actions.

Methods to be used to properly evaluate plant conditions without dependence on a single plant paramet~r will be reemphasized.

WestinghOuse has provided additional guidance to be con-sidered which involves modifications* to procedures re-lated to *termination of safety injection.

When the re-view of these guidelines by the PSE&G Task Force is com-pleted, _appropriate procedures will be revised and plant operators will be instructe4 in the revised.procedures.

c.

The results of the aforementioned reviews will be dis-cussed with the appropriate personnel and documentation provided as requested.

ITEM 2 A review of actions required by operating procedures for coping with transients and accidents is currently underway and is antici-

  • pated to be completed by the end of May, 1979.

The following items will be included in this review:

Mr. Boyce H. Grier 3 -

4-25-79 ITEM 2 (CONT.)

A.

Appropriate procedure revisions which should include the precautionary statements related to the possibility of void formation in the reactor coolant system.

The principal cause of voids in the primary system is a.decrease in pressurizer pressure below the saturation pressure of the RCS hot leg.

During LOCA conditions, *voiding in the RCS would be expected except for two situa-tions:

1.

A LOCA caused by an open pressurizer relief valve which is isolated prior to reaching hot leg saturation pres-sure.

2.

Safety injection flow balances the LOCA break flow and pressure does not reach saturation pressure.

Confirmation of no voids in the RCS during the two situations described above is as~

sured by observing pressurizer pressure above the saturated pressure.

In all other cases, it is not necessary to recognize void formation since the emergency core cooling systems have been designed to cope with the expected voiding.

B.

Appropriate procedure revisions which should specify the actions required to prevent *void formation.

Immediate actions which can be taken during most accidents to prevent void formation include:

1.

Verification of reactor trip.

2.

Verification of initiation of emer-gency core cooling.

3.

Verification of decreasing coolant temperature.

4.

Verification of water feed to steam

. generators.

5.

Maintenance of pressurizer water level via charging and safety in-jection flow control.

Mr. Boyce H. Grier B.

(CONT.)

4 -

6.

Dissipation of heat through steam

. generators.

7.

Maintenance of steam generator water levels in those steam generators not affected by the event.

In most LOCA situations,. operator action cannot prevent void formation but the emergency core cooling system is designed for thcise conditions.

Secondary sys~em tube leaks may lead to RCS voiding if the leak rate exceeds that value which can be countered by safety injection flow main-taining pressure above saturation pres-sure.

In this case, the leaking steam generator must be identified and isolated to prevent or minimize voiding.

4-25-79 C.

Review of emergency instructions to assure adequate de-scription of operator actions required to enhance core cooling in the event that voids are formed.

ITEM 3 The Salem Units were designed and licensed with a standard Westing-house logic (SSPS) which uses coincident pressurizer low level and low pressure signals to initiate safety injection.

PSE&G is pur-suing the following actions:

1.

A revised low-pressure logic is currently being developed by Westinghouse which will provide protection* and meet original design requirements for testability.

PSE&G e~

peCts to implement this change as soon as possible.

I

2.

Plant operations personnel will be instructed to manually initiate safety injection in the event pressurizer pres-sure drops below the initiation setpoint, as a backup to the automatic tni tiation signal. -

3.

The pressurizer level bistables are in the tripped con-dition and will remain in the tripped condition as direc'ted.

Mr. Boyce H. Grier 5 -

4-25-79 ITEM 4 The Salem design incorporates automatic initiation of containment isolation (Phase A) coincidental to safety injection initiation.

Phase A. isolation involves closure of automatic valves in all non-essential process lines *. A separate isolation signal (high-high containment pressure) will.result in Phase B isolation of the re-maining process lines.

Neither of these signals isolates safety injection, auxiliary feedwater or containment spray lines.

Our answer to Item 9 provides more information on this topic.

ITEM 5 The Salem auxiliary feedwater system has been designed as an auto-matic engineered safety system.

Additional personnel to manually operate this system are not required.

ITEM 6 Procedures exist to assure that operating personnel are aware of plant indications available to detect an open pressurizer power-operated relief valve.

These procedures include instructions to manually close these valves if they do not reclose as pressure de-creases below the opening setpoint.

Indications of an open PORV include the following:

1.

Relief valve open/close indicators on main control console.

2.

Pressurizer pressure indicators on main control console.*

3.

Pressurizer pressure recorder.

4.

Relief and safety valve discharge piping temperature indicators on main control console (computer monitoring also) *

5.

Pressurizer relief tank level, pressure and temperature

  • indication.
6.

Control room alarms for the above parameters.

ITEM 7 Operating procedures and training instructions are currently being reviewed to address the following items:

A.

Procedures for overriding or terminating safety injection are to be amplified to provide additional guidance in this area.

Westinghouse has submitted recommended changes which are being evaluated.

The basis for these changes is to assure termination of safety injection for those in-stances not requiring emergency core cooling which could result in unsafe conditions if not terminated.

Mr. Boyce H. Grier

..;. 6 -

4-25-79 ITEM 7 (CONT.)

A.

(CONT *. )

Examples of the situations requiring SI termination in-clude veri small LOCAs or secondary system breaks which lead to PORV opening during primary system heatup tran-sients.

Another example would be secondary side breaks which lead to primary system cooldown.

Continued safety injection could potentially exceed reactor vessel pres-sure criteria.

The recommended changes to procedures are based on assur-ing multiple indications of stable plant conditions prior to terminating safety injection.

Specific instructions to re-initiate safety injection are included to cover the possibility of subsequent system disturbances.

B.

  • The procedural changes described above are being evaluated to assure that monitoring key plant parameters is suf-ficient to guarantee subcooling.

For example, the para-meters considered to be relevant are:

1.

RCS pressure above 2000 psi and increasing.

2.

Narrow-range steam generator level indication.

3.

Pressurizer level above 50%.

Current procedures for cases of simultaneous high and low head pump injection are not expected to change.

c.

Procedures related to RCP trip following an accident are being evaluated.

PSE&G has been advised by Westinghouse.

  • .to trip all RCPs in LOCA and steambreak accidents* and has also provided additional clarification of the conditions permitting RCP trip.

The conditions which allow RCP trip are verification of ECCS operability, decreasing RCP pres-sure, or occurrence of Phase B containment isolation.

D.

Existing procedures and training emphasize that operators shoul<f not rely upon a single parameter to terminate safety injection.

In addition, Westinghouse has provided modified procedures which require checking of several parameters during accident conditions.

These changes will be evalu-ated to assure that sufficient information is available to the operator.

L Mr. Boyce H. Grier 7 -

4-25-79 ITEM 8 Existing design documents are being reviewed to. assure that safety related valves' positions are specified correctly for emergency operating conditions.

Such reviews ha.ve previously taken place dur-ing the desigri evolution of the Salem Units and it is expected that no deficiencies will be found existing in the Salem safety systems.

Several position indicating methods.are used for safety-related valves which are fully described.in the Salem FSAR (see attached) and are summarized as follows:

A.

ECCS valves normally positioned for safety injection which do not receive an actuation signal are provided with re-dundant and independent position indication in the main control room.

(Reference FSAR response to Question 6.3).

B.

Valves which receive an automatic actuation signal also are provided with redundant position indication as de-scribed in FSAR response to Question 7.8.

c.

Lockout of control or motive power has been used as an ad-tional means to assure proper valve position.

This design is de~cribed fully in FSAR responses to Questions 6.1, 6.3, 6.22, _6.26 and 7.8.

.D.

Additional position indication is provided on the main control console and the protection system status panel.

  • Alarms for valve "Off-Normal Position" are also provided.

These designs are described in the FSAR in Section 7.7.3 and in the response to FSAR Questions 7;.6 and 7.22.

The station Technical Specifications include requirements for as-suring that all valves important to safety are periodically checked and verified to be in the proper position.

Station procedures for testing and other activities are being re-viewed to assure *that. valves are returned to the proper position required by the Technical Specifications.

ITEM 9 The procedures associated with operation of systems for the transfer of potentially radioactive gases and liquids are being reviewed to assure that conditions cannot occur which could lead* to an inadver-tent transfer.

The systems being reviewed are liquid waste disposal, containment ventilation, and auxiliary building ventilation.

The design of the containment isolation system is such that a reset of the isolation signal will not directly cause an isolation valve to re-open.

The design criteria require that operator action be taken,

Mr. Boyce H. Grier 8 -

4-25-79 ITEM 9 (CONT.)

subsequent to an isolation signal reset, to open any isolation valve.

All of the valve's control circuits are being reviewed to further

.ensure compliance with this requirement and to ascertain that suf-ficient protection against inadvertent transfer of radioactive materials exists.

Radiation interlocks are provided for closure of the containment purge system isolation valves and pressure-vacuum relief valves to prevent releases in excess of technical specification limits.

Re-lease paths from the waste gas decay tanks and liquid radwaste dis-cha~ge line are also isolated by high radiation interlocks.

ITEM 10 Procedures are currently being reviewed to assure that they will verify the operabi*lity of safety system equipment prior to removal of equipment from service.

The suitability of this verification process on all safety systems is under review.

Where necessary, the procedures will be revised to include this requirement.

Verification of equipment operability following maintenance or testing is covered by the administrative procedures and is required by Technical Specifications operability requirements.. These pro-cedures are also being reviewed for possible modifications.

The removal and return to service of all safety system equipment is done in accordance with Station Administrative Procedures and is under the direc"t control of plant operations personnel.. These pro-cedures are also being reviewed for possible modifications.

ITEM 11 The emergency plan for Salem Nuclear Generating Station Units 1 and 2 provides for prompt reporting of the specified conditions to the NRC.

Steps are being taken to provide establishment of open com-munication with NRC Region I following the prompt notification.

ITEM 12 Operating modes and procedures.are available to deal with the ac- _

cumulation of hydrogen inside the primary system or containment.

Reactor coolant system hydrogen can be removed by a stripping process in the pressurizer vapor* space by using the pressurizer spray system.

The hydrogen can then be vented to the pressurizer relief tank.

Mr. Boyce H. Grier 9 -

4-25-79 ITEM 12 (CONT.)

Hydrogen can also be removed from the reactor coolant. via the let-down system and volume control tank where it is processed to the waste gas system.

During LOCA conditions, hydrogen would be vented to the containment.

Any post-LOCA hydrogen accumulation in the con-tainment cari be removed by.the permanently installed*hydrogen re-combiners which are located in the containment and qualified for this type of service.

  • Procedures dealing with the hydrogen gas that may be generated dur-ing a transient or accident are being reviewed.

We shall submit a supplemental response to this notice prior to May 31, 1979, which will describe the results of our review and status of implementation.

CC:. Director, Office of Inspection

-and Enforcement USNRC Washington, D. C. 20555 Sincerely,

~~

7.7.3 DESIGN DESCRIPTION The control room provides the necessary controls and indication to start, operate and shutdown the unit with sufficient redundant information displays and alarm indications to ensure safe and reliable operation under all normal and abnormal conditions.

The most important unit controls are located on the control console, which is of free-standing, horse-shoe shaped design, constructed of steel.

The front horizontal portion contains the most frequently used operating controls while the rear vertical portion contains less frequently used controls and indication.

Controls and indicators a,re functionally grouped on a system basis to facilitate safe, reliable operation of the unit during transients as well as normal operation.

Those systems requiring more frequent operator attention are located in the central area, while less frequently used controls are located on either side.

~

Most of the console instruments consist of ~lug-in, back-lighted push-button stations and vertical scale indicators.

Operator action consists of a momentary push of a button.

The lights in the buttons are used for status, information and alarm indication.

Alarms are provided in the control room to alert the operator of abnormal plant conditions.

The alarm displays are located either on a console pushbutton control station, where corrective action would be taken, or on the overhead annunciator.

An alarm signal causes a back-lighted push- -

button to flash and the console audible alarm to sound until acknowledged by the operator.

Upon clearing of an alarm condition, the console audible ringback is sounded.

Other alarms are displayed on an annunciator panel located overhead above the console.

This panel consists of illuminated SNGS-FSAR Units 1&2 7.7-3

L windows and separate audible alarm and ringback tones.

Two first-out annunciator panels indicate, by means of red and white lights, the first reactor or turbine trip to occur.

A comprehensive status panel, employing the same type of illuminated windows as the console, indicates the condition of trip channels and a:larms.

By means of a "mimic bus" arrangement, the interaction of trip conditions and permissives can be quickly analyzed.

Diesel generator automatic load sequencing, critical valve status and other important information are also clearly displayed.

A computer is employed to assist the operator and to monitor the unit.

Selected parameter trends can be recorded while alarm conditions are indicated to the operator. The computer output consists of a video display mounted on the console and logging typewriters located at the computer output terminal on the other side of the room.

logging typewriters are independent devices.

The video display and Vertical panels form the walls of the control room and contain controls for systems which require only occasional operator attention as well as miscellaneous recorders and indicators.

Reliability and ease of service has been designed into the control room.

The majority of the console instruments are plug-in modules.

In the un-likely case that a pushbutton station or indicator on the console mal-functions, it can be readily removed and replaced from the front of the console.

No access to the inside of the console is needed.

Relamping can also be quickly accomplished from the front of the pushbutton.

All pushbutton stations, the fire protection display panel, the overhead annunciator and the status panel contain at least two lamps at each point for increased reliability.

Low voltage (28V de) control is utilized for the console pushbutton stations.

A relay logic system performs the required switching and memory functions and provides the interface between the 28\\'

SNGS-FSAR Units 1&2 7.7-4 1,r.. 18

~*.--

QUESTION 6.1 If any of the seven valves shown on Figure 6.2-1 in the FSAR (Valves 1SJ30, 1SJ40, 1SJ69, llSJ54, l2SJ54, 13SJ54, and 14SJ54) were to be closed or were inadvertently closed when safety injection was required, the emergency core cooling could be significantly impaired during the injection phase of core cooling.

Provide a detailed discussion of how your design minimizes the probability of any of these valves being in a position that would adversely affect the proper performance of the emergency core cooling system (ECCS).

ANSWER The Salem plant design minimizes the probability of ECCS valves being improperly positioned by means of redundant position indication and administrative control to assure that motive or control power for the I 37 valves is locked out during normal plant operation.

Valves with redundant position indication (as described in the response to Question 7.8) and power lockouts are:

lSJ30*

11SJ40 --

llSJ54 1SJ69 12SJ40 12SJ54 1SJ135 1RH26 13SJ54 llSJ49*

1CS14 14SJ54 12SJ49*

1SJ67* i 11SJ44*

1SJ68*

12SJ44*

Valves marked with an asterisk (*) are provided with the capability to restore control power from the control room.

SNGS-FSAR Units 1&2 Q6.l-l Amendment 3 7 37

QUESTION 6. 3 State your design criterion for assuring the correct position of all valves, manual and remote-operated, in the safety injection system which do not receive a safety injection signal to aper..

(Reference the description on page 6.2-8 of the FSAR.)

Remotely operated valves in the Safety Injection System which are: in the "ready" position and which do not receive an "S" signal, are assured to be in the proper position for injection by means of the following:

a.

Redundant indication of valve position in the control rooc for those:

valves in cormnon, or non-redundant flo~ paths of an ECCS subsyste~,

or valves whose inadvertent operation could degrade the ECCS.

The:

indication provided is identical to that of the accumulator discharge valves, described in the response to Question 7.8. and is used for the valves cited in the response to Question 6.1.

b.

Valves in redundant flow paths are provided with position indication on the main control console and "off-noonal" indication in the aux-iliary annunciator system (i.e., 11RH4, 12RH4, 11SJ33, 12SJ33, llSJ13~.

12SJ134, 11RH19, 12RH19).

c.

Manually operated valves are under administrative control to assure that the:y are in the proper position.

Additionally, the valves cited in (a) above are placed in the proper position for injection with the motive power removed from the valve.

SNGS-FSAR Units 1&2 Q6.3-l Amendrnen t 2 9 26

Question 6.22 If the motor operated valve, CS 14, on Figure 6.4-1 in the FSAR were to be closed, or were inadvertently closed, when containmt:nt spra:; is re-quired, the addition of the chemical additive to the spray would bt:

prohibited.

Therefore, the effectiveness of containment spray woulc be impaired.

Discuss how the design ensures that this valve will be in the open position when needed.

Ans1.. :er

'Valve 1CS14 is provided with the same redundant position indication as the accumulator discharge valves, described in the response to Question 7.8.

SNGS-FSAR Tl-.: +-,...

1 r

15

QUESTION 6.26 Appendix K to 10 CFR Part 50 of the Commission's regulations requires that the combination of ECCS subsystems to be assumed operative shall be those available after the most damaging single failure of ECCS equipment has occurred.

The worst single failure which could minimize the ECC available to cool the core and provide maximum containment cooling was identified by Westinghouse as the loss of a low pressure ECCS pump.

As stated in our report "Status Report by the Directorate of Licensing in the Matter of Westinghouse Electric Corporation ECCS Evaluation Model Conformance to 10 CFR, Appendix K", October 15, 1974~

we concluded that the application of the single failure criterion was to be confirmed during subsequent plant reviews.

A review of the Salem Nuclear Generating Station Units 1 & 2, piping and instrumentation diagrams indicated that the inadvertent actuation of specific motor operated valves could affect the appropriate single failure assumptions.

You had previously identified thirteen valves and had indicated that removal of electrical power would satisfy the single failure criterion.

We have determined that. for valve 11SJ49, racking out of breakers at the motor control center is not an accept-able solution, since this valve must function promptly during switchover from injection to recirculation mode operation.

Our review has also identified several additional valves which did not meet single failure criteria.

The following is a complete list of the valves identified by you and the staff which will require modifications:

MOV/I 1SJ69 1SJ30

  • 1SJ67,
  • 1SJ68
llSJ49, 12SJ49 SNGS-FSAR Units 1&2 Component Function Isolates RHR System from RWST Isolates RWST from S. I. pumps Shutoff, S. I. pumps miniflow Isolates RHR System from RCS Q6. 26-1 Failure Mode Loss of suction flow to both RHR pumps Loss of RWST flow to both S.I. Pumps Damage or malfunction to S. I. pumps during pump operation prior to alignment for recirculation Reduction of ECC flow from RHR pumps to RCS Amendment 37

l

11SJ40, 1SJ135 1RH26 1CS14 llSJ54, 12SJ54, 13SJ54, 14SJ54
  • 11SJ44, 12SJ44 Isolates hot leg injection lines Safety injection System shutoff valve Isolates the RHR System from the RCS hot legs Isolates NaOH spray additive tank from Containment spray pumps Accumulator Isolation valves Containment recirculation sump supply to RHR pumps Opening of either valve during ECC injection and core ref lood will allow injection into RCS hot legs and cause steam binding.

Inadvertent action of the valve would stop S.I. flow to all loops Inadvertent opening of this valve would permit injection into RCS hot leg and cause steam binding Inadvertent closing of this valve would cause loss of NaOH spray Inadvertent closing of these valves would stop accumulator flow into RCS Loss of flow to RHR pump We have reviewed the consequences of the failures of the above valves and have evaluated your proposals for modification.

We have concluded that the following modifications are acceptable for complying with the single failure criterion:

(1)

As noted by you, during power operation AC power will be disconnected for valves lSJ30, 1SJ69, 1SJ35, 11SJ40, 12SJ40, 12SJ49, 1RH26, and 1CS14 by racking out of breakers at the motor control center.

Valves lSJ30, 1SJ69, 1SJ135, 12SJ49 and 1CS14 will be locked in their open position.

Valves 11SJ40, 12SJ40 and 1RH26 will be locked in their closed position.

  • Identified by the staff in its present review

.SNGS-FSAR Units 1 & 2 Q6.26-2 Amendment 37

(

l --

(2)

During power operation AC power will b*e disconnected for valves 11SJ54, 12SJ54, 13SJ54, and 14SJ54 by racking out of breakers at the motor control center.

These valves will be locked in the open position, since inadvertent actuation of any of these valves would stop accumulator flow.

(3)

During power operation AC power will be removed from valves 1SJ67, 1SJ68, and 11SJ49.

These valves will be in their open position and power will be restored from the control room for switchover to recirculation mode operation.

Necessity for this action is explained in the above table.

(4)

Prior to startup you have the option of either removing AC power from llSJ44 and 12SJ44, with the valves in their closed position, while retaining the capability of restoring power from the control room, or, by installing two check valves in the RHR suction header placing one between valves 1SJ69 and 11RH4 and the other between lSJ69 and 12RH4.

Either modification is necessary to eliminate the possible loss of flow to both RHR pumps in the event of the inadvertent actuation of either 11SJ44 or 12SJ44.

You also have the option of proposing other modifications to alleviate the problem.

The plant Technical Specifications should include a list of all electrically-operated valves, and their required positions, to which the requirement for removal of electric power has been applied.

You are also required to adhere to and implement Branch Technical Position EICSB-18*.

We will require that the above modifications be imple-mented prior to plant startup.

State your intent to comply with our requirements.

ANSWER It is our intent to comply with the above requirements.

Refer to the responses to Questions 6.1 and 6.2, as amended.

The plant Technical Specifications will include a list of the valves identified above and their required positions.

  • Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG-75/087), Chapter 7, Appendix 7A of Standard Review Plans Branch Technical Position EICSB-18, Application of the Single Failure Criterion to Manually-Controlled Electrically-Operated Valves.

SNGS-FSAR Units 1 & 2 Q6.26-3 Amendment 37

QUESTION 7.6 Discuss the indication available to the control room operator which would allow him to recognize that either a protection system or sub-system has been placed in test, bypassed for operation or maintenance purposes, or removed from service for any cause.

Provide this information on a system-by-system basis for the engineered safety feature equipment and instruments.

Also, include a listing of the operating bypasses and show that. they have been designed to meet the requirements of Paragraph 4.12 of IEEE-279.

ANSWER In general, if any analog channel in the ESF actuation system is taken out of service for any reason, the channel is placed in the tripped mode, and a channel trip status light is lit in the control room.

In addition, an alarm will sound and an associated annunciator panel light will be lit. This holds true for the containment pressure channel associated with safety injection arid steam line isolation functions.

The channel bistable output relays associated with the containmer.t spray function are not tripped, to reduce the possibility of inadvertent actuation, but are bypassed_ for test and maintenance purposes.

An alarm indicating a bypassed condition is provided for each channel.

The plant design includes one, or a combination, of the following indications to show the operator the status of plant systems and to highlight the existence of an incorrect configuration:

1.

Indication lights (Red-open and Green-closed) at the push-buttom control station for valves.

2.

A separate monitor light indication grouped with lights for other devices having a similar function such that the lights in the group are all on or are all off to provide for quick operator SNGS-FSAR Units 1&2 Q7.6-l Amendment 13

evaluation of systems status during the injection or recirculation mode of a LOCA.

3.

Auxiliary annunciation redundant to the above indications which serve to alert the op*erator of the improper state~ relative to plant conditions, of a critical device (pump, valve, etc.).

By looking at equipment status indications, an operator can determine if components in the ESF systems have been isolated or bypassed.

The following alarms have been provided in the control room to indicate test of bypass for ESF systems:

Spray channel comparator tripped (4 alarms)

Spray channel comparator on test (4 alarms)

Solid state protection train A trouble Solid state protection train B trouble Solid state protection train A on test Solid state protection train B on test Reactor protection channel on test (4 alarms)

Nuclear instrument channel on test Rod position indication on test Safeguards equipment control systems on test (3 alarms)

NIS loss of detector of compensation voltage (5 alarms)

NIS source range high flux at shutdown blocked NIS source and intermediate range trip bypass Diesel generator urgent trouble (3 alarms)

Diesel generator fuel oil day tank trouble 4Kv vital bus alarms (18 alarms)

The following lights on the status panel indicate bypass conditions:

Source range trip blocked (2 lights)

  • Source range trains A&B trip blocked Intermediate range trip blocked (2 lights)

Intermediate range trains A&B trip blocked Power range (low setpoint) trains A&B trip blocked Steamline isolation trains A&B safety injection blocked Safety injection blocked trains A&B Automatic safety injection blocked Overpower rod stop manual bypass (4 lights)

Steam dump block T average bypass SNGS-FSAR Units 1&2 Q7.6-2 Amendment 13

QUESTION 7. 8 The control circuits and the associated position indication and alarm circuits for the motor operated valves locaied between the accumulator tanks and the primary coolant system should be designed to meet the intent of IEEE-279.

The inclusion of the following features would provide*an acceptable design:

a.

Redundant independent visual indications in the control room of the open or closed status of the valve, with at least one set of indications actuated by sensors on the valve.

i--- b.

c.

An audible alarm, independent of item (a), that is actuated by a sensor on the valve when the valve is not in the fully open position and the primary system is at pressure.

Utilization of a safety injection signal t:o automatically renove (override) any bypass feature that may be provided to allow an isolation valve to be closed,. for short periods of time, when the primary coolant system is at pressure (in accordance with provisions of the Technical Specifications).

Discuss how your design differs from the above and explain how, even with these differences, it provides an equivalent degree of assurance that these isolation valves will be open when required.

Accumulator Discharge Valves Position indication and alarm circuits for the motor-operated valves, located between the accumulator tanks and the primary cooling system, are designed to provide assurance that these valves will be open when required.

These valves are normally open and under administrative control with the motive power for the valves locked out during norr.21 power operation.

Redundant and independent information is provided in the control room to indicate when any one valve is not in the fully open position.

Valve status (fully open or fully closed) is indicated on the main control board via backlighted pushbuttons.

These status lights are SNGS-FSAR Units 1&2 Q7.8-l Amendment 28 28

L 18 actuated by limit switches on the valve motor operator.

In addition, an alarm is provided on the overhead annunciator system in the event the valve is not in the fully open position.

Another independent means of determining that the valve is not in its proper position is provided through the auxiliary alarm system which will initiate an audible signal and print out an alarm message indi-28 I eating when the valve is not in the fully open position. This indication and alarm is derived from a separate valve stem limit 2&

switch and is energized from an independent power supply from that used for the overhead annunciator.

A safety injection signal also automatically initiates the opening of these valves.

The valve status and alarm provisions are shown functionally on Figure Q7.8-l.

SNGS-FSAR Units 1&2 Q7.8-2 Amendment 28

ROTOR II A II VALVE OPEi\\

OR CLOSED cm*SOLE STATUS LIGHTS

~.

VlSt:Al ROTOR "B"

VALVE !\\OT Ft.:LLY OPC~

OVERHEAD ANNU~~CIATOR.

it J

AUDIBLE ALA~'.

VALVE STE~

LI :-nT S\\.:ITCH ACXI LI ARY

~~~;L~Cl ATOR PRI};Tnt'T AL'DIBLE ALAR.'1 PUBLIC SERVICE ELECTRIC AND GAS COMPANY Accumulator Discharge Valves ~

SALEM NUCLEAR GENERATING STATION Status Monitoring FSAR

- Amendment 28 FIG. q1.s-1

QUESTION 7. 22 Supplement your response to our request No. 7.6 in Amendment 13 to the FSAR by providing a detailed description of the status indications and alarms of a typical ESF system (such as the Emergency Core Cooling System) that enable the control room operator to recognize that it had been bypassed or removed from service for any cause.

Your response should address both component and sys te~.s level indications.

A'\\SWER The containment spray system is a typical ESF system which incorporates the status indications described in the response to Question 7.6.

The spray pumps and the system motor-operated valves have ope~/

close lights on the main control console pushbutton stations and loss of control voltage alarms in the auxiliary alarm system.

The spray additive tank valve, 1CS14, also has an "off-normal position" alarm on the overhead annunciator.

Any equipment taken out of service for maintenance or other purposes is under the administrative control of the plant operating personnel, I which includes logging of unavailable equipment and covering the I control station with a plastic cover.

Bypasses of the Solid State Protection System outputs associated with the spray system are described in the response to Question 7.6.

s~cs..:.FsAR Units 1&2 Q7.22-1 Amendment 18