W$LFCREEK
'NUCLEAR OPERATING CORPORATION Cynthia R. Hafenstine Manager Regulatory Affairs U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 March 8, 2018 RA 18-0017
Subject:
Docket No. 50-482: Wolf Creek Generating Station Changes to Technical Specification Bases - Revisions 76 and 77 To Whom It May Concern:
The Wolf Creek Generating Station (WCGS) Unit 1 Technical Specifications (TS), Section 5.5.14, "Technical Specifications (TS) Bases Control Program," provide the means for making changes to the Bases without prior Nuclear Regulatory Commission (NRC) approval.
In addition, TS Section 5.5.14 requires that changes made without NRC approval be provided to the NRC on a frequency consistent with 10 CFR 50.71 (e).
The Enclosure provides those changes made to the WCGS TS Bases (Revisions 76 and 77) under the provisions to TS Section 5.5.14 and a List of Effective Pages. This submittal reflects changes from January 1, 2017, through December 31, 2017.
This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4204.
CRH/rlt Enclosure cc:
K. M. Kennedy (NRC), w/e B. K. Singal (NRC), w/e N. H. Taylor (NRC), w/e Senior Resident Inspector (NRC), w/e Sincerely, Cynthia R. Hafenstine P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET
Enclosure to RA 18-0017 Wolf Creek Generating Station Changes to the Technical Specification Bases (36 pages)
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3l DATE EFFECTIVE/
IMPLEMENTED <4>
TAB - Title Page Technical Specification Cover Page Title Page TAB - Table of Contents ii iii 34 29 44 TAB-B 2.0 SAFETY LIMITS (SLs)
B 2.1.1-1 0
B 2.1.1-2 14 B2.1.1-3 14 B 2.1.1-4 0
B2.1.2-1 0
B 2.1.2-2 12 B 2.1.2-3 0
ORR 07-1057 ORR 06-1984 ORR 09-1744 Amend. No. 123 ORR 03-0102 ORR 03-0102 Amend. No. 123 Amend. No. 123 ORR 02-1062 Amend. No. 123 TAB-B 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABIL TY B 3.0-1 34 ORR 07-1057 B 3.0-2 0
Amend. No. 123 B 3.0-3
- 0 Amend. No. 123 B 3.0-4 19 ORR 04-1414 B 3.0-5 19 ORR 04-1414 B 3.0-6 19 ORR 04-1414 B 3.0-7 19 ORR 04-1414 B 3.0-8 19 ORR 04-1414 B 3.0-9 42 ORR 09-1009 B 3.0-10 42 ORR 09-1009 B 3.0-11 34 ORR 07-1057 B 3.0-12 34 ORR 07-1057 B 3.0-13 34 ORR 07-1057 B 3.0-14 34 ORR 07-1057 B 3.0-15 34 ORR 07-1057 B 3.0-16 34 ORR 07-1057 TAB - B 3.1 REACTIVITY CONTROL SYSTEMS B 3.1.1-1 0
B 3.1.1-2 0
B3.1.1-3 0
B 3.1.1-4 19 B 3.1.1-5 0
B 3.1.2-1 0
B 3.1.2-2 0
B 3.1.2-3 0
B 3.1.2-4 0
B 3.1.2-5 0
B3.1.3-1 0
B 3.1.3-2 0
B 3.1.3-3 0
B 3.1.3-4 0
Wolf Creek - Unit 1 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 04-1414 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 7/10/07 10/17/06 10/28/09 12/18/99 2/12/03 2/12/03 2/12/03 12/18/99 9/26/02 12/18/99 7/10/07 12/18/99 12/18/99 10/12/04 10/12/04 10/12/04 10/12/04 10/12/04 7/16/09 7/16/09 7/10/07 7/10/07 7/10/07 7/10/07 7/10/07 7/10/07 12/18/99 12/18/99 12/18/99 10/12/04 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1l REVISION NO. (ZJ CHANGE DOCUMENT (3l DATE EFFECTIVE/
IMPLEMENTED (4l TAB-B 3.1 REACTIVITY CONTROL SYSTEMS {continued}
B 3.1.3-5 0
Amend. No. 123 12/18/99 B 3.1.3-6 0
Amend. No. 123 12/18/99 B3.1.4-1 0
Amend. No. 123 12/18/99 B 3.1.4-2 0
Amend. No. 123 12/18/99 B 3.1.4-3 48 ORR 10-3740 12/28/10 B 3.1.4-4 0
Amend. No. 123 12/18/99 B 3.1.4-5 0
Amend. No. 123 12/18/99 B 3.1.4-6 48 ORR 10-3740 12/28/10 B3.1.4-7 0
Amend. No. 123 12/18/99 B 3.1.4-8 0
Amend. No. 123 12/18/99 B 3.1.4-9 0
Amend. No. 123 12/18/99 B 3.1.5-1 0
Amend. No. 123 12/18/99 B 3.1.5-2 0
Amend. No. 123 12/18/99 B 3.1.5-3 0
Amend. No. 123 12/18/99 B3.1.5-4 0
Amend. No. 123 12/18/99 B3.1.6-1 0
Amend. No. 123 12/18/99 B 3.1.6-2 0
Amend. No. 123 12/18/99 B 3.1.6-3 0
Amend. No. 123 12/18/99 B 3.1.6-4 0
Amend. No. 123 12/18/99 B 3.1.6-5 0
Amend. No. 123 12/18/99 B 3.1.6-6 0
Amend. No. 123 12/18/99 B 3.1.7-1 0
Amend. No. 123 12/18/99 B 3.1.7-2 0
Amend. No. 123 12/18/99 B 3.1.7-3 48 ORR 10-3740 12/28/10 B3.1.7-4 48 ORR 10-3740 12/28/10 B 3.1.7-5 48 ORR 10-3740 12/28/10 B 3.1.7-6 0
Amend. No. 123 12/18/99 B3.1.8-1 0
Amend. No. 123 12/18/99 B 3.1.8-2 0
Amend. No. 123 12/18/99 B 3.1.8-3 15 ORR 03-0860 7/10/03 B 3.1.8-4 15 ORR 03-0860 7/10/03 B 3.1.8-5 0
Amend. No. 123 12/18/99 B3.1.8-6 5
ORR 00-1427 10/12/00 TAB - B 3.2 POWER DISTRIBUTION LIMITS B3.2.1-1 48 ORR 10-3740 12/28/10 B 3.2.1-2 0
Amend. No. 123 12/18/99 B 3.2.1-3 48 ORR 10-3740 12/28/10 B 3.2.1-4 48 ORR 10-3740 12/28/10 B 3.2.1-5 48 ORR 10-3740 12/28/10 B 3.2.1-6 48 ORR 10-3740 12/28/10 B3.2.1-7 48 ORR 10-3740 12/28/10 B 3.2.1-8 48 ORR 10-3740 12/28/10 B 3.2.1-9 29 ORR 06-1984 10/17/06 B 3.2.1-10 70 ORR 15-0944 4/28/15 B 3.2.2-1 48 ORR 10-3740 12/28/10 B 3.2.2-2 0
Amend. No. 123 12/18/99 B 3.2.2-3 48 ORR 10-3740 12/28/10 B 3.2.2-4 48 ORR 10-3740 12/28/10 B 3.2.2-5 48 ORR 10-3740 12/28/10 B 3.2.2-6 70 ORR 15-0944 4/28/15 Wolf Creek - Unit 1 ii Revision76
LIST OF EFFECTIVE PAGES-TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB - B 3.2 POWER DISTRIBUTION LIMITS (continued)
B 3.2.3-1 0
Amend. No. 123 B 3.2.3-2 0
Amend. No. 123 B 3.2.3-3 0
Amend. No. 123 B 3.2.4-1 0
Amend. No. 123 B 3.2.4-2 0
Amend. No. 123 B 3.2.4-3 48 DRR 10-3740 B 3.2.4-4 0
Amend. No. 123 B 3.2.4-5 48 DRR 10-3740 B 3.2.4-6 0
Amend. No. 123 B 3.2.4-7 48 DRR 10-3740 TAB-B 3.3 INSTRUMENTATION B 3.3.1-1 B 3.3.1-2.
B 3.3.1-3 B 3.3.1-4 B 3.3.1-5 B 3.3.1-6 83.3.1-7 B 3.3.1-8 B 3.3.1-9 B 3.3.1-10 83.3.1-11 B 3.3.1-12 B 3.3.1-13 B 3.3.1-14 B 3.3.1-15 B 3.3.1-16 B 3.3.1-17 B 3.3.1-18 B 3.3.1-19 83.3.1-20 B 3.3.1-21 B 3.3.1-22 B 3.3.1-23 B 3.3.1-24 B 3.3.1-25 B 3.3.1-26 B 3.3.1-27 B 3.3.1-28 B 3.3.1-29 B 3.3.1-30 B 3.3.1-31 B 3.3.1-32 B 3.3.1-33 B 3.3.1-34 B 3.3.1-35 B 3.3.1-36 B 3.3.1-37 B 3.3.1-38 B 3.3.1-39 Wolf Creek - Unit 1 0
0 0
0 0
0 5
0 0
29 0
0 0
0 0
0 0
0 66 66 0
0 9
0 0
0 0
2 1
1 0
20 48 20 19 20 20 20 25
.iii Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 00-1427 Amend. No. 123 Amend. No. 123 DRR 06-1984 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 14-2329 DRR 14-2329 Amend. No. 123 Amend. No. 123 DRR 02-0123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 00-0147 DRR 99-1624
, DRR 99-1624 Amend. No. 123 DRR 04-1533 DRR 10-3740 DRR 04-1533 DRR 04-1414 DRR 04-1533 DRR 04-1533 DRR 04-1533 DRR 06-0800 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/28/10 12/18/99 12/28/10 12/18/99 12/28/10 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 10/12/00 12/18/99 12/18/99 10/17/06 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 11/6/14 11/6/14 12/18/99 12/18/99 2/28/02 12/18/99 12/18/99 12/18/99 12/18/99 4/24/00 12/18/99 12/18/99 12/18/99 2/16/05 12/28/10 2/16/05 10/13/04 2/16/05 2/16/05 2/16/05 5/18/06 Revision76
LIST OF EFFECTIVE PAGES -TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB-B 3.3 INSTRUMENTATION (continued)
B3.3.1-40 1
20 B 3.3.1-41 20 B 3.3.1-42 20 B 3.3.1-43 20 B 3.3.1-44 20 B 3.3.1-45 20 B 3.3.1-46 48 B 3.3.1-47 20 B 3.3.1-48 48 B3.3.1-49 20 B3.3.1-50 20 B3.3.1-51 21 B 3.3.1-52 20 B 3.3.1-53 20 B 3.3.1-54 20 B 3.3.1-55 25 B 3.3.1-56 66 B3.3.1-57 20 B 3.3.1-58 29 B3.3.1-59 20 B 3.3.2-1 0
B 3.3.2-2 0
B 3.3.2-3 0
B 3.3.2-4 0
B 3.3.2-5 0
B 3.3.2-6 7
B 3.3.2-7 0
B 3.3.2-8 0
B 3.3.2-9 0
B 3.3.2-10 0
B 3.3.2-11 0
B 3.3.2-12 0
B 3.3.2-13 0
B 3.3.2-14 2
B 3.3.2-15 0
B 3.3.2-16 0
B 3.3.2-17 0
B 3.3.2-18 0
B 3.3.2-19 37 B 3.3.2-20 37 B 3.3.2-21 37 B 3.3.2-22 37 B 3.3.2-23 37 B 3.3.2-24 39 B 3.3.2-25 39 B 3.3.2-26 39 B 3.3.2-27 37 B 3.3.2-28 37 B 3.3.2-29 0
B 3.3.2-30 0
B 3.3.2-31 52 Wolf Creek - Unit 1 CHANGE DOCUMENT <3l DATE EFFECTIVE/
IMPLEMENTED <4l iv ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 10-3740 ORR 04-1533 ORR 10-3740 ORR 04-1533 ORR 04-1533 ORR 05-0707 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 06-0800 ORR 14-2329 ORR 04-1533 ORR 06-1984 ORR 04-1533 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 01-0474 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 00-0147 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-1096 ORR 08-1096 ORR 08-1096 ORR 08-0503 ORR 08-0503 Amend. No. 123 Amend. No. 123 ORR 11-0724 2/16/05 2/16/05 2/16/05 2/16/05 2/16/05 2/16/05 12/28/10 2/16/05 12/28/10 2/16/05 2/16/05 4/20/05 2/16/05 2/16/05 2/16/05 5/18/06 11/6/14 2/16/05 10/17/06 2/16/05 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 5/1/01 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 4/24/00 12/18/99 12/18/99 12/18/99 12/18/99 4/8/08 4/8/08 4/8/08 4/8/08 4/8/08 8/28/08 8/28/08 8/28/08 4/8/08 4/8/08 12/18/99 12/18/99 4/11/11 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1l REVISION NO. (2l CHANGE DOCUMENT <3l DATE EFFECTIVE/
IMPLEMENTED (4l TAB-B 3.3 INSTRUMENTATION {continued}
B 3.3.2-32 52 ORR 11-0724 4/11 /11 B 3.3.2-33 0
Amend. No. 123 12/18/99 B 3.3.2-34 0
Amend. No. 123 12/18/99 B 3.3.2-35 20 ORR 04-1533 2/16/05 B 3.3.2-36 20 ORR 04-1533 2/16/05 B 3.3.2-37 20 ORR 04-1533 2/16/05 B 3.3.2-38 20 ORR 04-1533 2/16/05 B 3.3.2-39 25 ORR 06-0800 5/18/06 B 3.3.2-40 20 ORR 04-1533 2/16/05 B 3.3.2-41 45 Amend. No. 187 (ETS) 3/5/10 B 3.3.2-42 45 Amend. No. 187 (ETS) 3/5/10 B 3.3.2-43 20 ORR 04-1533 2/16/05 B 3.3.2-44 20 ORR 04-1533 2/16/05 B 3.3.2-45 20 ORR 04-1533 2/16/05 B 3.3.2-46 54 ORR 11-2394 11/16/11 B 3.3.2-47 43 ORR 09-1416 9/2/09 B 3.3.2-48 37 ORR 08-0503 4/8/08 B 3.3.2-49 20 ORR 04-1533 2/16/05 B 3.3.2-50 20 ORR 04-1533 2/16/05 B 3.3.2-51 43 ORR 09-1416 9/2/09 B 3.3.2-52 43 ORR 09-1416 9/2/09 B 3.3.2-53 43 ORR 09-1416 9/2/09 B 3.3.2-54 43 ORR 09-1416 9/2/09 B 3.3.2-55 43 ORR 09-1416 9/2/09 B 3.3.2-56 43 ORR 09-1416 9/2/09 B 3.3.2-57 43 ORR 09-1416 9/2/09 B 3.3.3-1 0
Amend. No. 123 12/18/99 B 3.3.3-2 5
ORR 00-1427 10/12/00 B 3.3.3-3 0
Amend. No. 123 12/18/99 B 3.3.3-4 0
Amend. No. 123 12/18/99 B 3.3.3-5 0
Amend. No. 123 12/18/99 B 3.3.3-6 8
ORR 01-1235 9/19/01 B 3.3.3-7 21 ORR 05-0707 4/20/05 B 3.3.3-8 8
ORR 01-1235 9/19/01 B 3.3.3-9 8
ORR 01-1235 9/19/01 B 3.3.3-10 19 ORR 04-1414 10/12/04 B 3.3.3-11 19 ORR 04-1414 10/12/04 B 3.3.3-12 21 ORR 05-0707 4/20/05 B 3.3.3-13 21 ORR 05-0707 4/20/05 B 3.3.3-14 8
ORR 01-1235 9/19/01 B 3.3.3-15 8
ORR 01-1235 9/19/01 B 3.3.4-1 0
Amend. No. 123 12/18/99 B 3.3.4-2 9
ORR 02-1023 2/28/02 B 3.3.4-3 15 ORR 03-0860 7/10/03 B 3.3.4-4 19 ORR 04-1414 10/12/04 B 3.3.4-5 1
ORR 99-1624 12/18/99 B 3.3.4-6 9
ORR 02-0123 2/28/02 B 3.3.5-1 0
Amend. No. 123 12/18/99 B 3.3.5-2 1
ORR 99-1624 12/18/99 B 3.3.5-3 1
ORR 99-1624 12/18/99 Wolf Creek - Unit 1 V
Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB-B 3.3 INSTRUMENTATION (continued)
B 3.3.5-4 B 3.3.5-5 B 3.3.5-6 B 3.3.5-7 B 3.3.6-1 B 3.3.6-2 B 3.3.6-3 B 3.3.6-4 B 3.3.6-5 B 3.3.6-6 B 3.3.6-7 B 3.3.7-1 B 3.3.7-2 B 3.3.7-3 B 3.3.7-4 B 3.3.7-5 B 3.3.7-6 B 3.3.7-7 B 3.3.7-8 B 3.3.8-1 B 3.3.8-2 B 3.3.8-3 B 3.3.8-4 B 3.3.8-5 B 3.3.8-6 B 3.3.8-7 1
0 22 22 0
0 0
0 0
0 0
0 57 57 0
0 57 0
0 0
0 57 57 0
24 0
TAB-B 3.4 REACTOR COOLANT SYSTEM (RCS)
B 3.4.1-1 0
B 3.4.1-2 10 B 3.4.1-3 10 B3.4.1-4 0
B3.4.1~
0 B 3.4.1-6 0
B 3.4.2-1 0
B 3.4.2-2 0
B 3.4.2-3 0
B 3.4.3-1 67 B 3.4.3-2 0
B 3.4.3-3 0
B 3.4.3-4 0
B 3.4.3-5 0
B 3.4.3-6 0
B 3.4.3-7 0
B 3.4.4-1 0
B 3.4.4-2 29 B 3.4.4-3 0
B 3.4.5-1 0
B 3.4.5-2 53 B 3.4.5-3 29 B 3.4.5-4 0
Wolf Creek - Unit 1 CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
vi DRR 99-1624 Amend. No. 123 DRR 05-1375 DRR 05-1375 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 13-0006 DRR 13-0006 Amend. No. 123 Amend. No. 123 DRR 13-0006 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 13-0006 DRR 13-0006 Amend. No. 123 DRR 06-0051 Amend. No. 123 Amend. No. 123 DRR 02-0411 DRR 02-0411 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 15-0116 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 06-1984 Amend. No. 123 Amend. No. 123 DRR 11-1513 DRR 06-1984 Amend. No. 123 12/18/99 12/18/99 6/28/05 6/28/05 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 1/16/13 1/16/13 12/18/99 12/18/99 1/16/13 12/18/99 12/18/99 12/18/99 12/18/99 1/16/13 1/16/13 12/18/99 2/28/06 12/18/99 12/18/99 4/5/02 4/5/02 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 2/10/15 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 10/17/06 12/18/99 12/18/99 7/18/11 10/17/06 12/18/99 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1l REVISION NO. <2l CHANGE DOCUMENT <3l DA TE EFFECTIVE/
IMPLEMENTED <4l TAB - B 3.4 REACTOR COOLANT SYSTEM {RCS} {continued}
B 3.4.5-5 12 ORR 02-1062 9/26/02 B 3.4.5-6 12 ORR 02-1062 9/26/02 B 3.4.6-1 53 ORR 11-1513 7/18/11 B 3.4.6-2 72 ORR 15-1918 10/26/15 B 3.4.6-3 12 ORR 02-1062 9/26/02 B 3.4.6-4 72 ORR 15-1918 10/26/15 B 3.4.6-5 75 ORR 16-1909 10/26/16 B 3.4.6-6 75 ORR 16-1909 10/26/16 B 3.4.7-1 12 ORR 02-1062 9/26/02 B 3.4.7-2 17 ORR 04-0453 5/26/04 B 3.4.7-3 72 ORR 15-1918 10/26/15 B 3.4.7-4 42 ORR 09-1009 7/16/09 B 3.4.7-5 72 ORR 15-1918 10/26/15 B 3.4.7-6 75 ORR 16-1909 10/26/16 B 3.4.8-1 53 ORR 11-1513 7/18/11 B 3.4.8-2 72 ORR 15-1918 10/26/15 B 3.4.8-3 42 ORR 09-1009 7/16/09 B 3.4.8-4 75 ORR 16-1909 10/26/16 B 3.4.8-5 72 ORR 15-1918 10/26/15 B 3.4.9-1 0
Amend. No. 123 12/18/99 B 3.4.9-2 0
Amend. No. 123 12/18/99 B 3.4.9-3 0
Amend. No. 123 12/18/99 B 3.4.9-4 0
Amend. No. 123 12/18/99 B 3.4.10-1 5
ORR 00-1427 10/12/00 B 3.4.10-2 5
ORR 00-1427 10/12/00 B 3.4.10-3 0
Amend. No. 123 12/18/99 B 3.4.10-4 32 ORR 07-0139 217/07 B 3.4.11-1 0
Amend. No. 123 12/18/99 B 3.4.11-2 1
ORR 99-1624 12/18/99 B3.4.11-3 19 ORR 04-1414 10/12/04 83.4.11-4 0
Amend. No. 123 12/18/99 B 3.4.11-5 1
ORR 99-1624 12/18/99 B 3.4.11-6 0
Amend. No. 123 12/18/99 83.4.11-7 32 ORR 07-0139 2/7/07 B 3.4.12-1 61 ORR 14-0346 2/27/14 B 3.4.12-2 61 ORR 14-0346 2/27/14 B 3.4.12-3 0
Amend. No. 123 12/18/99 B 3.4.12-4 61 ORR 14-0346 2/27/14 B 3.4.12-5 61 ORR 14-0346 2/27/14 B 3.4.12-6 56 ORR 12-1792 1.1/7/12 B 3.4.12-7 61 ORR 14-0346 2/27/14 B 3.4.12-8 1
ORR 99-1624 12/18/99 B 3.4.12-9 56 ORR 12-1792 11/7/12 B 3.4.12-10 0
Amend. No. 123 12/18/99 B 3.4.12-11 61 ORR 14-0346 2/27/14 B 3.4.12-12 32 ORR 07-0139 2/7/07 B 3.4.12-13 0
Amend. No. 123 12/18/99 B3.4.12-14 32 ORR 07-0139 217/07 B 3.4.13-1 0
Amend. No. 123 12/18/99 B 3.4.13-2 29 ORR 06-1984 10/17/06 B 3.4.13-3 29 ORR 06-1984 10/17/06 Wolf Creek - Unit 1 vii Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1l REVISION NO. (ZJ CHANGE DOCUMENT (3l DATE EFFECTIVE/
IMPLEMENTED <4>
TAB-B 3.4 REACTOR COOLANT SYSTEM (RCS) (continued)
B 3.4.13-4 35 DRR 07-1553 B 3.4.13-5 35 DRR 07-1553 B 3.4.13-6 29 DRR 06-1984 B 3.4.14-1 0
Amend. No. 123 B 3.4.14-2 0
Amend. No. 123 B 3.4.14-3 0
Amend. No. 123 B 3.4.14-4 0
Amend. No. 123 B 3.4.14-5 32 DRR 07-0139 B 3.4.14-6 32 DRR 07-0139 B 3.4.15-1 31 DRR 06-2494 B 3.4.15-2 31 DRR 06-2494 B 3.4.15-3 33 DRR 07-0656 B 3.4.15-4 33 DRR 07-0656 B 3.4.15-5 65 DRR 14-2146 B 3.4.15-6 31 DRR 06-2494 B 3.4.15-7 31 DRR 06-2494 B 3.4.15-8 31 DRR 06-2494 B 3.4.16-1 31 DRR 06-2494 B 3.4.16-2 31 DRR 06-2494 B 3.4.16-3 31 DRR 06-2494 B 3.4.16-4 31 DRR 06-2494 B 3.4.16-5 31 DRR 06-2494 B 3.4.17-1 29 DRR 06-1984 B 3.4.17-2 58 DRR 13-0369 B 3.4.17-3 52 DRR 11-0724 B 3.4.17-4 57 DRR 13-0006 B 3.4.17-5 57 DRR 13-0006 B 3.4.17-6 57 DRR 13-0006 B 3.4.17-7 58 DRR 13-0369 TAB - B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS)
B 3.5.1-1 0
Amend. No. 123 B 3.5.1-2 0
Amend. No. 123 B 3.5.1-3 73 DRR 15-2135 B 3.5.1-4 73 DRR 15-2135 B 3.5.1-5 1
DRR 99-1624 B 3.5.1-6 1
DRR 99-1624 B 3.5.1-7 71 DRR 15-1528 B 3.5.1-8 1
DRR 99-1624 B 3.5.2-1 0
Amend. No. 123 B 3.5.2-2 0
Amend. No. 123 B 3.5.2-3 0
Amend. No. 123 B 3.5.2-4 0
Amend. No. 123 B 3.5.2-5 72 DRR 15-1918 B 3.5.2-6 42 DRR 09-1009 B 3.5.2-7 42 DRR 09-1009 B 3.5.2-8 72 DRR 15-1918 B 3.5.2-9 75 DRR 16-1909 B 3.5.2-10 72 DRR 15-1918 B 3.5.2-11 72 DRR 15-1918 B 3.5.2-12 72 DRR 15-1918 Wolf Creek - Unit 1 viii 9/28/07 9/28/07 10/17/06 12/18/99 12/18/99 12/18/99 12/18/99 217107 217107 12/13/06 12/13/06 5/1/07 5/1/07 9/30/14 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 10/17/06 02/26/13 4/11 /11 1/16/13 1/16/13 1/16/13 02/26/13 12/18/99 12/18/99 11/17/15 11/17/15 12/18/99 12/18/99 7/30/15 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 10/26/15 7/16/09 7/16/09 10/26/15 10/26/16 10/26/15 10/26/15 10/26/15 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1>
REVISION NO. (Z>
CHANGE DOCUMENT (3>
DATE EFFECTIVE/
IMPLEMENTED (4>
TAB - B 3.5 EMERGENCY CORE COOLING SYSTEMS {ECCS} {continued}
B 3.5.3-1 56 DRR 12-1792 11/7/12 B 3.5.3-2 72 DRR 15-1918 10/26/15 B 3.5.3-3 56 DRR 12-1792 11/7/12 B 3.5.3-4 56 DRR 12-1792 11/7/12 B 3.5.4-1 0
Amend. No. 123 12/18/99 B 3.5.4-2 0
Amend. No. 123 12/18/99 B 3.5.4-3 0
Amend. No. 123 12/18/99 B 3.5.4-4 0
Amend. No. 123 12/18/99 B 3.5.4-5 0
Amend. No. 123 12/18/99 B 3.5.4-6 26 DRR 06-1350 7/24/06 B 3.5.5-1 21 DRR 05-0707 4/20/05 B 3.5.5-2 21 DRR 05-0707 4/20/05 B 3.5.5-3 2
Amend. No. 132 4/24/00 B 3.5.5-4 21 DRR 05-0707 4/20/05 TAB-B 3.6 CONTAINMENT SYSTEMS B 3.6.1-1 0
Amend. No. 123 12/18/99 B 3.6.1-2 0
Amend. No. 123 12/18/99 B 3.6.1-3 0
Amend. No. 123 12/18/99 B 3.6.1-4 17 DRR 04-0453 5/26/04 B 3.6.2-1 0
Amend. No. 123 12/18/99 B 3.6.2-2 0
Amend. No. 123 12/18/99 B 3.6.2-3 0
Amend. No. 123 12/18/99 B 3.6.2-4 0
Amend. No. 123 12/18/99 B 3.6.2-5 0
Amend. No. 123 12/18/99 B 3.6.2-6 0
Amend. No. 123 12/18/99 B 3.6.2-7 0
Amend. No. 123 12/18/99 B 3.6.3-1 0
Amend. No. 123 12/18/99 B 3.6.3-2 0
Amend. No. 123 12/18/99 B 3.6.3-3 0
Amend. No. 123 12/18/99 B 3.6.3-4 49 DRR 11-0014 1/31/11 B 3.6.3-5 49 DRR 11-0014 1/31/11 B 3.6.3-6 49 DRR 11-0014 1/31/11 B 3.6.3-7 41 DRR 09-0288 3/20/09 B 3.6.3-8 36 DRR 08-0255 3/11/08 B 3.6.3-9 36 DRR 08-0255 3/11/08 B 3.6.3-10 8
DRR 01-1235 9/19/01 B 3.6.3-11 36 DRR 08-0255 3/11/08 B 3.6.3-12 36 DRR 08-0255 3/11/08 B 3.6.3-13 50 DRR 11-0449 3/9/11 B 3.6.3-14 36 DRR 08-0255 3/11/08 B 3.6.3-15 39 DRR 08-1096 8/28/08 B 3.6.3-16 39 DRR 08-1096 8/28/08 B 3.6.3-17 36 DRR 08-0255 3/11/08 B 3.6.3-18 36 DRR 08-0255 3/11/08 B 3.6.3-19 36 DRR 08-0255 3/11/08 B3.6.4-1 39 DRR 08-1096 8/28/08 B 3.6.4-2 0
Amend. No. 123 12/18/99 B 3.6.4-3 0
Amend. No. 123 12/18/99 B 3.6.5-1 0
Amend. No. 123 12/18/99 B 3.6.5-2 37 DRR 08-0503 4/8/08 Wolf Creek - Unit 1 ix Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB-B 3.6 CONTAINMENT SYSTEMS (continued)
B 3.6.5-3 13 B 3.6.5-4 0
B 3.6.6-1 42 B 3.6.6-2 63 B 3.6.6-3 37 B 3.6.6-4 72 B 3.6.6-5 0
B 3.6.6-6 18 B 3.6.6-7 72 B 3.6.6-8 72 B 3.6.6-9 72 B 3.6.6-10 75 B 3.6.6.11 75 B 3.6.7-1 0
B 3.6.7-2 42 B 3.6.7-3 0
B 3.6.7-4 29 B 3.6.7-5 42 TAB-B 3.7 PLANT SYSTEMS B 3.7.1-1 0
B 3.7.1-2 0
B 3.7.1-3 0
B 3.7.1-4 0
B 3.7.1-5 32 B3.7.1-6 32 B 3.7.2-1 44 B 3.7.2-2 44 B 3.7.2-3 44 B 3.7.2-4 44 B 3.7.2-5 44 B3.~2~
44 B 3.7.2-7 44 B 3.7.2-8 44 B 3.7.2-9 44 B 3.7.2-10 44 B 3.7.2-11 44 B 3.7.3-1 37 B 3.7.3-2 50 B 3.7.3-3 37 B 3.7.3-4 37 B 3.7.3-5 37 B 3.7.3-6 37 B 3.7.3-7 37 B 3.7.3-8 37 B 3.7.3-9 66 B 3.7.3-10 66 B3.7.3-11 37 B 3.7.4-1 1
B 3.7.4-2 1
B 3.7.4-3 19 Wolf Creek - Unit 1 CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
X ORR 02-1458 Amend. No. 123 ORR 09-1009 ORR 14-1572 ORR 08-0503 ORR 15-1918 Amend. No. 123 ORR 04-1018 ORR 15-1918 ORR 15-1918 ORR 15-1918 ORR 16-1909 ORR 16-1909 Amend. No. 123 ORR 09-1009 Amend. No. 123 ORR 06-1984 ORR 09-1009 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 07-0139 ORR 07-0139 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 08-0503 ORR 11-0449 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 14-2329 ORR 14-2329 ORR 08-0503 ORR 99-1624 ORR 99-1624 ORR 04-1414 12/03/02 12/18/99 7/16/09 7/1/14 4/8/08 10/26/15 12/18/99 9/1/04 10/26/15 10/26/15 10/26/15 10/26/16 10/26/16 12/18/99 7/16/09 12/18/99 10/17/06 7/16/09 12/18/99 12/18/99 12/18/99 12/18/99 2/7/07 2/7/07 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 4/8/08 3/9/11 4/8/08 4/8/08 4/8/08 4/8/08 4/8/08 4/8/08 11/6/14 11/6/14 4/8/08 12/18/99 12/18/99 10/12/04 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB - B 3.7 PLANT SYSTEMS (continued)
B 3.7.4-4 B 3.7.4-5 B 3.7.5-1 B 3.7.5-2 B 3.7.5-3 B 3.7.5-4 B 3.7.5-5 B 3.7.5-6 B 3.7.5-7 B 3.7.5-8 B 3.7.5-9 B 3.7.6-1 B 3.7.6-2 B 3.7.6-3 B 3.7.7-1 B 3.7.7-2 B 3.7.7-3 B 3.7.7-4 B 3.7.8-1 B 3.7.8-2 B 3.7.8-3 B 3.7.8-4 B 3.7.8-5 B 3.7.9-1 B 3.7.9-2 B 3.7.9-3 B 3.7.9-4 B 3.7.10-1 B 3.7.10-2 B 3.7.10-3 B 3.7.10-4 B 3.7.10-5 B 3.7.10-6 B 3.7.10-7 B 3.7.10-8 B 3.7.10-9 B3.7.11-1 B3.7.11-2 B 3.7.11-3 B3.7.11-4 B3.7.12-1 B3.7.13-1 B 3.7.13-2 B 3.7.13-3 B 3.7.13-4 B 3.7.13-5 B 3.7.13-6 B 3.7.13-7 B 3.7.13-8 B 3.7.14-1 B 3.7.15-1 Wolf Creek - Unit 1 19 1
54 54 0
76 76 76 76 76 76 0
0 0
0 0
0 1
0 0
0 0
0 3
3 3
3 64 41 41 41 57 57 64 41 64 0
57 63 63 0
24 1
75 57 57 64 64 64 0
0 CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
xi ORR 04-1414 ORR 99-1624 ORR 11-2394 ORR 11-2394 Amend. No. 123 ORR 17-0343 ORR 17-0343 ORR 17-0343 ORR 17-0343 ORR 17-0343 ORR 17-0343 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 99-1624 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 134 Amend. No. 134 Amend. No. 134 Amend. No. 134 ORR 14-1822 ORR 09-0288 ORR 09-0288 ORR 09-0288 ORR 13-0006 ORR 13-0006 ORR 14-1822 ORR 09-0288 ORR 14-1822 Amend. No. 123 ORR 13-0006 ORR 14-1572 ORR 14-1572 Amend. No. 123 ORR 06-0051 ORR 99-1624 ORR 16-1909 ORR 13-0006 ORR 13-0006 ORR 14-1822 ORR 14-1822 ORR 14-1822 Amend. No. 123 Amend. No. 123 10/12/04 12/18/99 11/16/11 11/16/11 12/18/99 2/21/17 2/21/17 2/21/17 2/21/17 2/21/17 2/21/17 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 7/14/00 7/14/00 7/14/00 7/14/00 8/28/14 3/20/09 3/20/09 3/20/09 1/16/13 1/16/13 8/28/14 3/20/09 8/28/14 12/18/99 1/16/13 7/1/14 7/1/14 12/18/99 2/28/06 12/18/99 7/16/09 1/16/13 1/16/13 8/28/14 8/28/14 8/28/14 12/18/99 12/18/99 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1l REVISION NO. <2l CHANGE DOCUMENT <3l DATE EFFECTIVE/
IMPLEMENTED <4l TAB-B 3.7 PLANT SYSTEMS {continued}
B3.7.15-2 0
Amend. No. 123 12/18/99 B 3.7.15-3 0
Amend. No. 123 12/18/99 B 3.7.16-1 5
ORR 00-1427 10/12/00 B 3.7.16-2 23 ORR 05-1995 9/28/05 B 3.7.16-3 5
ORR 00-1427 10/12/00 B 3.7.17-1 7
ORR 01-0474 5/1/01 B 3.7.17-2 7
ORR 01-0474 5/1/01 B 3.7.17-3 5
ORR 00-1427 10/12/00 B 3.7.18-1 0
Amend. No. 123 12/18/99 B 3.7.18-2 0
Amend. No. 123 12/18/99 B 3.7.18-3 0
Amend. No. 123 12/18/99 B 3.7.19-1 44 ORR 09-1744 10/28/09 B 3.7.19-2 54 ORR 11-2394 11/16/11 B 3.7.19-3 54 ORR 11-2394 11/16/11 B 3.7.19-4 61 ORR 14-0346 2/27/14 B 3.7.19-5 61 ORR 14-0346 2/27/14 B 3.7.19-6 54 ORR 11-2394 11/16/11 B 3.7.19-7 54 ORR 11-2394 11/16/11 TAB-B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.1-1 54 ORR 11-2394 11/16/11 B3.8.1-2 0
Amend. No. 123 12/18/99 B3.8.1-3 75 ORR 16-1909 10/26/16 B 3.8.1-4 71 ORR 15-1528 7/30/15 B 3.8.1-5 59 ORR 13-1524 6/26/13 B3.8.1-6 25 ORR 06-0800 5/18/06 B 3.8.1-7 26 ORR 06-1350 7/24/06 B 3.8.1-8 35 ORR 07-1553 9/28/07 B 3.8.1-9 42 ORR 09-1009 7/16/09 B3.8.1-10 39 ORR 08-1096 8/28/08 B 3.8.1-11 36 ORR 08-0255 3/11/08 B 3.8.1-12 75 ORR 16-1909 10/26/16 B 3.8.1-13 47 ORR 10-1089 6/16/10 B3.8.1-14 47 ORR 10-1089 6/16/10 B 3.8.1-15 47 ORR 10-1089 6/16/10 B 3.8.1-16 26 ORR 06-1350 7/24/06 B 3.8.1-17 26 ORR 06-1350 7/24/06 B 3.8.1-18 59 ORR 13-1524 6/26/13 B 3.8.1-19 26 ORR 06-1350 7/24/06 B 3.8.1-20 26 ORR 06-1350 7/24/06 B 3.8.1-21 33 ORR 07-0656 5/1/07 B 3.8.1-22 33 ORR 07-0656 5/1/07 B 3.8.1-23 74 ORR 16-1182 7/7/16 B 3.8.1-24 74 ORR 16-1182 7/7/16 B 3.8.1-25 74 ORR 16-1182 7/7/16 B 3.8.1-26 74 ORR 16-1182 7/7/16 B 3.8.1-27 74 ORR 16-1182 7/7/16 B 3.8.1-28 74 ORR 16-1182 7/7/16 B 3.8.1-29 74 ORR 16-1182 7/7/16 B 3.8.1-30 74 ORR 16-1182 7/7/16 B3.8.1-31 74 ORR 16-1182 7/7/16 Wolf Creek - Unit 1 xii Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED (4>
TAB-B 3.8 ELECTRICAL POWER SYSTEMS (continued)
B 3.8.1-32 74 ORR 16-1182 B 3.8.1-33 74 ORR 16-1182 B 3.8.1-34 74 ORR 16-1182 B 3.8.2-1 57 ORR 13-0006 B 3.8.2-2 0
Amend. No. 123 B 3.8.2-3 0
Amend. No. 123 B 3.8.2-4 57 ORR 13-0006 B 3.8.2-5 57 ORR 13-0006 B 3.8.2-6 57 ORR 13-0006 B 3.8.2-7 57 ORR 13-0006 B 3.8.3-1 1
ORR 99-1624 B 3.8.3-2 0
Amend. No. 123 B 3.8.3-3 0
Amend. No. 123 B 3.8.3-4 1
ORR 99-1624 B 3.8.3-5 0
Amend. No. 123 B 3.8.3-6 0
Amend. No. 123 B 3.8.3-7 12 ORR 02-1062 B 3.8.3-8 1
ORR 99-1624 B 3.8.3-9 0
Amend. No. 123 B 3.8.4-1 0
Amend. No. 123 B 3.8.4-2 0
Amend. No. 123 B 3.8.4-3 0
Amend. No. 123 B 3.8.4-4 0
Amend. No. 123 B 3.8.4-5 50 ORR 11-0449 B 3.8.4-6 50 ORR 11-0449 B 3.8.4-7 6
ORR 00-1541 B 3.8.4-8 0
Amend. No. 123 B 3.8.4-9 2
ORR 00-0147 B 3.8.5-1 57 ORR 13-0006 B 3.8.5-2 0
Amend. No. 123 B 3.8.5-3 57 ORR 13-0006 B 3.8.5-4 57 ORR 13-0006 B 3.8.5-5 57 ORR 13-0006 B 3.8.6-1 0
Amend. No. 123 B 3.8.6-2 0
Amend. No. 123 B 3.8.6-3 0
Amend. No. 123 B 3.8.6-4 0
Amend. No. 123 B 3.8.6-5 0
Amend. No. 123 B 3.8.6-6 0
Amend. No. 123 B 3.8.7-1 69 ORR 15-0493 B 3.8.7-2 69 ORR 15-0493 B 3.8.7~3 69 ORR 15-0493 B 3.8.7-4 0
Amend. No. 123 B 3.8.8-1 57 ORR 13-0006 B 3.8.8-2 0
Amend. No. 123 B 3.8.8-3 69 ORR 15-0493 B 3.8.8-4 57 ORR 13-0006 B 3.8.8-5 69 ORR 15-0493 83.8.9-1 54 DRR11-2394 B 3.8.9-2 69 ORR 15-0493 B 3.8.9-3 54 ORR 11-2394 Wolf Creek - Unit 1 xiii 7/7/16 7/7/16 717/16 1/16/13 12/18/99 12/18/99 1/16/13 1/16/13 1/16/13 1/16/13 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 9/26/02 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 3/9/11 3/9/11 3/13/01 12/18/99 4/24/00 1/16/13 12/18/99 1/16/13 1/16/13 1/16/13 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 3/26/15 3/26/15 3/26/15.
12/18/99 1/16/13 12/18/99 3/26/15 1/16/13 3/26/15 11/16/11 3/26/15 11/16/11 Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1l REVISION NO. <2l CHANGE DOCUMENT <3l DATE EFFECTIVE/
IMPLEMENTED <4l TAB - B 3.8 ELECTRICAL POWER SYSTEMS (continued)
B 3.8.9-4 0
Amend. No. 123 12/18/99 B 3.8.9-5 69 ORR 15-0493 3/26/15 B 3.8.9-6 0
Amend. No. 123 12/18/99 B 3.8.9-7 0
Amend. No. 123 12/18/99 B 3.8.9-8 1
ORR 99-1624 12/18/99 B 3.8.9-9 0
Amend. No. 123 12/18/99 B 3.8.10-1 57 ORR 13-0006 1/16/13 B 3.8.10-2 0
Amend. No. 123 12/18/99 B 3.8.10-3 0
Amend. No. 123 12/18/99 B 3.8.10-4 57 ORR 13-0006 1/16/13 B 3.8.10-5 57 ORR 13-0006 1/16/13 B 3.8.10-6 57 ORR 13-0006 1/16/13 TAB - B 3.9 REFUELING OPERATIONS B 3.9.1-1 0
Amend. No. 123 12/18/99 B3.9.1-2 19 ORR 04-1414 10/12/04 B3.9.1-3 19 ORR 04-1414 10/12/04 B 3.9.1-4 19 ORR 04-1414 10/12/04 B 3.9.2-1 0
Amend. No. 123 12/18/99 B 3.9.2-2 0
Amend. No. 123 12/18/99 B 3.9.2-3 0
Amend. No. 123 12/18/99 B 3.9.3-1 68 ORR 15-0248 2/26/15 B 3.9.3-2 68 ORR 15-0248 2/26/15 B 3.9.3-3 51 ORR 11-0664 3/21 /11 B 3.9.3-4 68 ORR 15-0248 2/26/15 B3.9.4-1 23 ORR 05-1995 9/28/05 B 3.9.4-2 13 ORR 02-1458 12/03/02 B 3.9.4-3 25 ORR 06-0800 5/18/06 B 3.9.4-4 23 ORR 05-1995 9/28/05 B 3.9.4-5 33 ORR 07-0656 5/1/07 B.3.9.4-6 23 ORR 05-1995 9/28/05 B 3.9.5-1 0
Amend. No. 123 12/18/99 B 3.9.5-2 72 ORR 15-1918 10/26/15 B 3.9.5-3 32 ORR 07-0139 2/7/07 B 3.9.5-4 75 ORR 16-1909 10/26/16 B 3.9.5-5 75 ORR 16-1909 10/26/16 B 3.9.6-1 0
Amend. No. 123 12/18/99 B 3.9.6-2 72 ORR 15-1918 10/26/15 B 3.9.6-3 42 ORR 09-1009 7/16/09 B 3.9.6-4 72 ORR 15-1918 10/26/15 B 3.9.6-5 75 ORR 16-1909 10/26/16 B 3.9.7-1 25 ORR 06-0800 5/18/06 B 3.9.7-2 0
Amend. No. 123 12/18/99 B 3.9.7-3 0
Amend. No. 123 12/18/99 Wolf Creek - Unit 1 xiv Revision76
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE <1>
REVISION NO. <2>
CHANGE DOCUMENT (3>
DATE EFFECTIVE/
IMPLEMENTED (4>
Note 1 The page number is listed on the center of the bottom of each page.
Note 2 The revision number is listed in the lower right hand corner of each page. The Revision number will be page specific.
Note 3 The change document will be the document requesting the change. Amendment No.
123 issued the improved Technical Specifications and associated Bases which affected each page. The NRC has indicated that Bases changes will not be issued with License Amendments. Therefore, the change document should be a ORR number in accordance with AP 26A-002.
Note 4 The date effective or implemented is the date the Bases pages are issued by Document Control.
Wolf Creek - Unit 1 xv Revision76
BASES LCO (continued)
Wolf Creek - Unit 1 AFW System B 3.7.5 the CST to an ESW supply and supplying AFW to two steam generators.
The turbine driven AFW pump is required to be OPERABLE with redundant steam supplies from each of two main steam lines upstream of the MS IVs, and shall be capable of automatically transferring the suction from the CST to an ESW supply and supplying AFW to any of the steam generators. The piping, valves, instrumentation, and controls in the required flow paths also are required to be OPERABLE: The inoperability of a single supply line or a single suction isolation valve from an ESW train to the turbine driven AFW pump causes a loss of redundancy in ESW supply to the pump but does not render the turbine driven AFW train inoperable. The supply line begins at the point where the ESW piping branches into two lines, one supplying the motor driven AFW pump and one supplying the turbine driven AFW pump, and ends at the suction of the turbine driven AFW pump (Ref. 3). Therefore, with one ESW train inoperable, the associated motor driven AFW train is considered inoperable; and one turbine driven AFW pump supply line is considered inoperable. However, the turbine driven AFW train is OPERABLE based on the remaining OPERABLE ESW supply line.
In order for the turbine driven AFW pump and motor driven AFW pumps to be OPERABLE while the AFW System is in automatic control or above 10% RTP, the discharge flow control valves shall be in the full open position, except when the motor driven AFW pumps discharge flow control valves are automatically throttled in response to actual AFW flow (Ref. 5). When~ 10% RTP, the turbine driven AFW pump and motor driven AFW pumps remain OPERABLE with the discharge flow control valves throttled as needed to maintain steam generator levels.
The standby lineup for the turbine driven AFW steam supply lines is when the main steam supply valves, ABHV0005 and ABHV0006, are closed and OPERABLE and the warmup valves, ABHV0048 and ABHV0049, are open and OPERABLE. With a main steam supply valve and its associated warmup valve closed, the turbine driven AFW steam supply line is inoperable. The turbine driven AFW pump is inoperable when restoring a steam supply line to service if both the main steam supply valve and its associated warmup valve were closed, until such time after the restoration of the warm up line that the rate of condensate being drained is low enough that the steam trap FCST0001 and/or the bypass valve FCLV0010 are adequately draining the system as evidenced by no alarms on annunciator 00-128F in the control room.
During normal standby lineup, the turbine driven AFW pump is inoperable if the rate of condensation in the line is exceeding the capability of the steam trap FCST0001 and the bypass valve FCLV0010 as evidenced by a high level alarm on annunciator 00-128F in the control room that does not clear upon being acknowledged.
B 3.7.5-4 Revision 76
BASES LCO (continued)
APPLICABILITY ACTIONS Wolf Creek - Unit 1 AFW System B 3.7.5 The nitrogen accumulator tanks supplying the turbine driven AFW pump control valves and the steam generator atmospheric relief valves ensure an eight hour supply for the pump and valves.
Although the AFW System may be used in MODE 4 to remove decay heat, the LCO does not require the AFW System to be OPERABLE in MODE 4 since the RHR System is available for decay heat removal.
In MODES 1, 2, and 3, the AFW System is required to be OPERABLE in the event that it is called upon to function when the MFW is lost. In addition, the AFW System is required to supply enough makeup water to replace the steam generator secondary inventory, lost as the unit cools to MODE 4 conditions.
In MODE 4 the AFW System may be used for heat removal via the steam generators but is not required since the RHR System is available and required to be OPERABLE in this MODE.
In MODE 5 or 6, the steam generators are not normally used for heat removal, and the AFW System is not required.
A Note prohibits the application of LCO 3.0.4b. to an inoperable AFW train when entering MODE 1. There is an increased risk associated with entering MODE 1 with an AFW train inoperable and the provisions of LCO 3.0.4b., which allow entry into a MODE, or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
If one of the two steam supplies to the turbine driven AFW train is inoperable, action must be taken to restore OPERABLE status within 7 days. The 7 day Completion Time is reasonable, based on the following reasons:
- a.
The redundant OPERABLE steam supply to the turbine driven AFW pump;
- b.
The availability of redundant OPERABLE motor driven AFW pumps; and
- c.
The low probability of an event occurring that requires the inoperable steam supply to the turbine driven AFW pump.
B 3.7.5-5 Revision 76 I
BASES ACTIONS (continued)
Wolf Creek - Unit 1 AFW System B 3.7.5 The second Completion Time for Required Action A.1 establishes a limit on the maximum time allowed for any combination of Conditions to be inoperable during any continuous failure to meet this LCO.
The 10 day Completion Time provides a limitation time allowed in this specified Condition after discovery of failure to meet the LCO. This limit is considered reasonable for situations in which multiple Conditions are entered concurrently. The AND connector between 7 days and 10 days dictates that both Completion Times apply simultaneously, and the more restrictive must be met With one of the required AFW trains (pump or flow path) inoperable for reasons other than Condition A, action must be taken to restore OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. This Condition includes the loss of two steam supply lines to the turbine driven AFW pump. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time is reasonable, based on redundant capabilities afforded by the AFW System, time needed for repairs, and the low probability of a OBA occurring during this time period.
The second Completion Time for Required Action B.1 establishes a limit on the maximum time allowed for any combination of Conditions to be inoperable during any continuous failure to meet this LCO.
The 10 day Completion Time provides a limitation time allowed in this specified Condition after discovery of failure to meet the LCO. This limit is considered reasonable for situations in which Conditions A and B are entered concurrently. The AND connector between 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> and 10 days dictates that both Completion Times apply simultaneously, and the more restrictive must be met.
C.1 and C.2 When Required Action A.1 or B.1 cannot be completed within the required Completion Time, or if two AFW trains are inoperable, the unit must be placed in a MODE in which the LCO does not apply. To achieve this status, the unit must be placed in at least MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in MODE 4 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.
B 3.7.5-6 Revision 76 I
BASES AFW System B 3.7.5 ACTIONS D.1 (continued)
SURVEILLANCE REQUIREMENTS Wolf Creek - Unit 1 If all three AFW trains are inoperable, the unit is in a seriously degraded condition with no safety related means for conducting a cooldown, and only limited means for conducting a cooldown with nonsafety related equipment. In such a condition, the unit should not be perturbed by any action, including a power change, that might result in a trip. The seriousness of this condition requires that action be started immediately to restore one AFW train to OPERABLE status.
Required Action D.1 is modified by a Note indicating that all required MODE changes or power reductions are suspended until one AFW train is restored to OPERABLE status. In this case, LCO 3.0.3 is not applicable because it could force the unit into a less safe condition.
SR 3.7.5.1 Verifying the correct alignment for manual, power operated, and automatic valves in the AFW System water and steam supply flow paths provides assurance that the proper flow paths will exist for AFW operation. This SR does not apply to valves that are locked, sealed, or otherwise secured in position, since they are verified to be in the correct position prior to locking, sealing, or securing. This SR also does not apply to manual vent/drain valves, and to valves that cannot be inadvertently misaligned, such as check valves. This Surveillance does not require any testing or valve manipulation; rather, it involves verification that those valves capable of being mispositioned are in the correct position.
The 31 day Frequency, based on engineering judgment, is consistent with procedural controls governing valve operation, and ensures correct valve positions.
This SR is modified by a Note indicating that the SR is not required to be performed for the AFW flow control valves until the AFW System is placed in standby or THERMAL POWER is above 10% RTP.
SR 3.7.5.2 Verifying that each AFW pump's developed head at the flow test point is greater than or equal to the required developed head ensures that AFW pump performance has not degraded during the cycle. Flow and differential head are normal tests of centrifugal pump performance required by the ASME Code (Ref. 2). Because it is undesirable to introduce cold AFW into the steam generators while they are operating, this testing is performed on recirculation flow. This test confirms one point B 3.7.5-7 Revision 76
BASES SURVEILLANCE REQUIREMENTS Wolf Creek - Unit 1 SR 3.7.5.2 (continued)
AFW System B 3.7.5 on the pump design curve and is indicative of overall performance. Such inservice tests confirm component OPERABILITY, trend performance, and detect incipient failures by indicating abnormal performance.
Performance of inservice testing discussed in the ASME Code (Ref. 2)
(only required at 3 month intervals) satisfies this requirement. The test Frequency in accordance with the lnservice Testing Program results in testing each pump once every 3 months, as required by Reference 2.
When on recirculation, the required differential pressure for the AFW pumps (Ref. 4) when tested in accordance with the lnservice Testing Program is:
Motor Driven Pumps
- 2: 1514 psid at a nominal flow of 110 gpm Turbine Driven Pump
- 2: 1616.4 psid at a nominal flow of 130 gpm This SR is modified by a Note indicating that the SR should be deferred until suitable test conditions are established. This deferral is required because there is insufficient steam pressure to perform the test.
SR 3.7.5.3 This SR verifies that AFW can be delivered to the appropriate steam generator in the event of any accident or transient that generates an ESFAS, by demonstrating that each automatic valve in the flow path actuates to its correct position on an actual or simulated actuation signal.
This Surveillance is not required for valves that are locked, sealed, or otherwise secured in the required position under administrative controls.
The 18 month Frequency is based on the need to perform this Surveillance under the conditions that apply during a unit outage and the potential for an unplanned transient if the Surveillance were performed with the reactor at power. The 18 month Frequency is acceptable based on operating experience and the design reliability of the equipment.
This SR includes the requirement to verify that each AFW motor-operated discharge valve limits the flow from the motor driven AFW pump to each steam generator to ::::; 320 gpm and that valves in the ESW suction flowpath actuate to the full open position upon receipt of an Auxiliary Feedwater Pump Suction Pressure-Low signal.
B 3.7.5-8 Revision 76 I
BASES SURVEILLANCE REQUIREMENTS REFERENCES Wolf Creek - Unit 1 SR 3.7.5.4 AFW System B 3.7.5 This SR verifies that the AFW pumps will start in the event of any accident or transient that generates an AFAS by demonstrating that each AFW pump starts automatically on an actual or simulated actuation signal. The 18 month Frequency is based on the need to perform this Surveillance under the conditions that apply during a unit outage and the potential for an unplanned transient if the Surveillance were performed with the reactor at power.
This SR is modified by a Note. The Note indicates that the SR be deferred until suitable test conditions are established. This deferral is required because there is insufficient steam pressure to perform the test.
SR 3.7.5.5 This SR verifies that the AFW is properly aligned by verifying the flow paths from the CST to each steam generator prior to entering MODE 2 after more than 30 days in MODE 5 or 6. OPERABILITY of AFW flow paths must be verified before sufficient core heat is generated that would require the operation of the AFW System during a subsequent shutdown.
The Frequency is reasonable, based on engineering judgement and other administrative controls that ensure that flow paths remain OPERABLE.
To further ensure AFW System alignment, flow path OPERABILITY is verified following extended outages to determine no misalignment of valves has occurred. This SR ensures that the flow path from the CST to the steam generators is properly aligned.
- 1.
USAR, Section 10.4.9.
- 2.
ASME Code for Operation and Maintenance of Nuclear Power Plants.
- 3.
NRG letter (C. Poslusny to 0. Maynard) dated December 16, 1998:
"Wolf Creek Generating Station - Technical Specification Bases Change, Auxiliary Feedwater System."
- 4.
Performance Improvement Request 2002-0945.
- 5.
Condition Report 2006-000188.
B 3.7.5-9 Revision 76 I
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB - Title Page Technical Specification Cover Page Title Page TAB-Table of Contents ii iii 34 29 44 TAB - B 2.0 SAFETY LIMITS (SLs)
B 2.1.1-1 0
B 2.1.1-2 14 B 2.1.1-3 14 B 2.1.1-4 0
B2.1.2-1 0
B 2.1.2-2 12 B 2.1.2-3 0
ORR 07-1057 ORR 06-1984 ORR 09-1744 Amend. No. 123 ORR 03-0102 ORR 03-0102 Amend. No. 123 Amend. No. 123 ORR 02-1062 Amend. No. 123 TAB-B 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILTY B 3.0-1 34 ORR 07-1057 B 3.0-2 0
Amend. No. 123 B 3.0-3 0
Amend. No. 123 B 3.0-4 19 ORR 04-1414 B 3.0-5 19 ORR 04-1414 B 3.0-6 19 ORR 04-1414 B 3.0-7 19 ORR 04-1414 B 3.0-8 19 ORR 04-1414 B 3.0-9 42 ORR 09-1009 B 3.0-10 42 ORR 09-1009 B 3.0-11 34 ORR 07-1057 B 3.0-12 34 ORR 07-1057 B 3.0-13 34 ORR 07-1057 B 3.0-14 34 ORR 07-1057 B 3.0-15 34 ORR 07-1057 B 3.0-16 34 ORR 07-1057 TAB-B 3.1 REACTIVITY CONTROL SYSTEMS B 3.1.1-1 0
B 3.1.1-2 0
B 3.1.1-3 0
B 3.1.1-4 19 B 3.1.1-5 0
B3.1.2-1 0
B 3.1.2-2 0
B 3.1.2-3 0
B 3.1.2-4 0
B 3.1.2-5 0
B 3.1.3-1 0
B 3.1.3-2 0
B 3.1.3-3 0
B 3.1.3-4 0
Wolf Creek - Unit 1 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 04-1414 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 7/10/07 10/17/06 10/28/09 12/18/99 2/12/03 2/12/03 2/12/03 12/18/99 9/26/02 12/18/99 7/10/07 12/18/99 12/18/99 10/12/04 10/12/04 10/12/04 10/12/04 10/12/04 7/16/09 7/16/09 7/10/07 7/10/07 7/10/07 7/10/07 7/10/07 7/10/07 12/18/99 12/18/99 12/18/99 10/12/04 12/18/99
- 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 Revision77
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1l REVISION NO. (2l CHANGE DOCUMENT (3l DATE EFFECTIVE/
IMPLEMENTED (4l TAB-B 3.1 REACTIVITY CONTROL SYSTEMS (continued)
B 3.1.3-5 0
Amend. No. 123 B 3.1.3-6 0
Amend. No. 123 B 3.1.4-1 0
Amend. No. 123 B 3.1.4-2 0
Amend. No. 123 B 3.1.4-3 48 ORR 10-3740 B 3.1.4-4 0
Amend. No. 123 B 3.1.4-5 0
Amend. No. 123 B 3.1.4-6 48 ORR 10-37 40 B 3.1.4-7 0
Amend. No. 123 B 3.1.4-8 0
Amend. No. 123 B3.1.4-9 0
Amend.No.123 B 3.1.5-1 0
Amend. No. 123 B 3.1.5-2 0
Amend. No. 123 B 3.1.5-3 0
Amend. No. 123 B 3.1.5-4 0
Amend. No. 123 B 3.1.6-1 O
Amend. No. 123 B 3.1.6-2 0
Amend. No. 123 B 3.1.6-3 0
Amend. No. 123 B 3.1.6-4 0
Amend. No. 123 B 3.1.6-5 0
Amend. No. 123 B 3.1.6-6 0
Amend. No. 123 B 3.1.7-1 0
Amend. No. 123 B3.1.7-2 0
Amend.No.123 B3.1.7-3 48 DRR10-3740 B3.1.7-4 48 DRR10-3740 B3.1.7-5 48 DRR10-3740 B 3.1.7-6 0
Amend. No. 123 B 3.1.8-1 0
Amend. No. 123 B 3.1.8-2 0
Amend. No. 123 B 3.1.8-3 15 ORR 03-0860 B 3.1.8-4 15 ORR 03-0860 B 3.1.8-5 0
Amend. No. 123 B3.1.8-6 5
DRR00-1427 TAB - B 3.2 POWER DISTRIBUTION LIMITS B 3.2.1-1 48 B 3.2.1-2 0
B 3.2.1-3 48 B 3.2.1-4 48 B 3.2.1-5 48 B 3.2.1-6 48 B 3.2.1-7 48 B 3.2.1-8 48 B 3.2.1-9 B 3.2.1-10 B 3.2.2-1 B 3.2.2-2 B 3.2.2-3 B 3.2.2-4 B 3.2.2-5 B 3.2.2-6 Wolf Creek - Unit 1 29 70 48 0
48 48 48 70 ii ORR 10-3740 Amend. No. 123 ORR 10-3740 ORR 10-3740 ORR 10-3740 ORR 10-3740 ORR 10-3740 ORR 10-3740 ORR 06-1984 ORR 15-0944 ORR 10-3740 Amend. No. 123 ORR 10-3740 ORR 10-3740 ORR 10-3740 ORR 15-0944 12/18/99 12/18/99 12/18/99 12/18/99 12/28/10 12/18/99 12/18/99 12/28/10 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/28/10 12/28/10 12/28/10 12/18/99 12/18/99 12/18/99 7/10/03 7/10/03 12/18/99 10/12/00 12/28/10 12/18/99 12/28/10 12/28/10 12/28/10 12/28/10 12/28/10 12/28/10 10/17/06 4/28/15 12/28/10 12/18/99 12/28/10 12/28/10 12/28/10 4/28/15 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB - B 3.2 POWER DISTRIBUTION LIMITS (continued)
B 3.2.3-1 0
Amend. No. 123 B 3.2.3-2 0
Amend. No. 123 B 3.2.3-3 0
Amend. No. 123 B 3.2.4-1 0
Amend. No. 123 B 3.2.4-2 0
Amend. No. 123 B 3.2.4-3 48 ORR 10-3740 B 3.2.4-4 0
Amend. No. 123 B 3.2.4-5 48 ORR 10-3740 B 3.2.4-6 0
Amend. No. 123 B 3.2.4-7 48 DRR 10-3740 TAB-B 3.3 INSTRUMENTATION B 3.3.1-1 B 3.3.1-2 B 3.3.1-3 B 3.3.1-4 B 3.3.1-5 B 3.3.1-6 B 3.3.1-7 B 3.3.1-8 B 3.3.1-9 B 3.3.1-10 B 3.3.1-11 B 3.3.1-12 B 3.3.1-13 B 3.3.1-14 B 3.3.1-15 B3.3.1-16 B 3.3.1-17 B 3.3.1-18 B 3.3.1-19 B 3.3.1-20
. B 3.3.1-21 B 3.3.1-22 B 3.3.1-23 B 3.3.1-24 B 3.3.1-25 B 3.3.1-26 B 3.3.1-27 B 3.3.1-28 B 3.3.1-29 B 3.3.1-30 B 3.3.1-31 B 3.3.1-32 B 3.3.1-33 B 3.3.1-34 B 3.3.1-35 B 3.3.1-36 B 3.3.1-37 B 3.3.1-38 B 3.3.1-39 Wolf Creek - Unit 1 0
0 0
0 0
0 5
0 0
29 0
0 0
0 0
0 0
0 66 66 0
0 9
0 0
0 0
2 1
1 0
20 48 20 19 20 20 20 25 iii Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 00-1427 Amend. No. 123 Amend. No. 123 DRR 06-1984 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 14-2329 ORR 14-2329 Amend. No. 123 Amend. No. 123 ORR 02-0123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 00-0147 ORR 99-1624 ORR 99-1624 Amend. No. 123 ORR 04-1533 ORR 10-3740 DRR 04-1533 DRR 04-1414 ORR 04-1533 ORR 04-1533 DRR 04-1533 ORR 06-0800 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/28/10 12/18/99 12/28/10 12/18/99 12/28/10 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 10/12/00 12/18/99 12/18/99 10/17/06 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 11/6/14 11/6/14 12/18/99 12/18/99 2/28/02 12/18/99 12/18/99 12/18/99 12/18/99 4/24/00 12/18/99 12/18/99 12/18/99 2/16/05 12/28/10 2/16/05 10/13/04 2/16/05 2/16/05 2/16/05 5/18/06 Revision77
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB-B 3.3 INSTRUMENTATION (continued)
B 3.3.1-40 20 B 3.3.1-41 20 B 3.3.1-42 20 B 3.3.1-43 20 B 3.3.1-44 20 B 3.3.1-45 20 B 3.3.1-46 48 B 3.3.1-47 20 B 3.3.1-48 48 B 3.3.1-49 20 B3.3.1-50 20 83.3.1-51 21 B3.3.1-52 20 83.3.1-53 20 B 3.3.1-54 20 B 3.3.1-55 25 B 3.3.1-56 66 B 3.3.1-57 20 B 3.3.1-58 29 B 3.3.1-59 20 B3.3.2-1 0
B 3.3.2-2 0
B 3.3.2-3 0
B 3.3.2-4 0
B 3.3.2-5 0
B 3.3.2-6 7
B 3.3.2-7 0
B 3.3.2-8 0
B 3.3.2-9 0
B 3.3.2-10 0
B 3.3.2-11 0
B 3.3.2-12 0
B 3.3.2-13 0
B 3.3.2-14 2
B 3.3.2-15 0
B 3.3.2-16 0
B 3.3.2-17 0
B 3.3.2-18 0
B 3.3.2-19 37 B 3.3.2-20 37 B 3.3.2-21 37 B 3.3.2-22 37 B 3.3.2-23 37 B 3.3.2-24 39 B 3.3.2-25 39 B 3.3.2-26 39 B 3.3.2-27 37 B 3.3.2-28 37 B 3.3.2-29 0
B 3.3.2-30 0
B 3.3.2-31 52 Wolf Creek - Unit 1 CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
iv ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 10-3740 ORR 04-1533 ORR 10-3740 ORR 04-1533 ORR 04-1533 ORR 05-0707 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 06-0800 ORR 14-2329 ORR 04-1533 ORR 06-1984 ORR 04-1533 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 01-0474 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 00-0147 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-1096 ORR 08-1096 ORR 08-1096 ORR 08-0503 ORR 08-0503 Amend. No. 123 Amend. No. 123 ORR 11-0724 2/16/05 2/16/05 2/16/05 2/16/05 2/16/05 2/16/05 12/28/10 2/16/05 12/28/10 2/16/05 2/16/05 4/20/05 2/16/05 2/16/05 2/16/05 5/18/06 11/6/14 2/16/05 10/17/06 2/16/05 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 5/1/01 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 4/24/00 12/18/99 12/18/99 12/18/99 12/18/99 4/8/08 4/8/08 4/8/08 4/8/08 4/8/08 8/28/08 8/28/08 8/28/08 4/8/08 4/8/08 12/18/99 12/18/99 4/11/11 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE'1>
REVISION NO. '2>
TAB-B 3.3 INSTRUMENTATION (continued)
B 3.3.2-32 52 B 3.3.2-33 0
B 3.3.2-34 0
B 3.3.2-35 20 B 3.3.2-36 20 B 3.3.2-37 20 B 3.3.2-38 20 B 3.3.2-39 25 B 3.3.2-40 20 B 3.3.2-41 45 B 3.3.2-42 45 B 3.3.2-43 20 B 3.3.2-44 20 B 3.3.2-45 20 B 3.3.2-46 54 B 3.3.2-47 43 B 3.3.2-48 37 B 3.3.2-49 20 B 3.3.2-50 20 B 3.3.2-51 43 B 3.3.2-52 43 B 3.3.2-53 43 B 3.3.2-54 43 B 3.3.2-55 43 B 3.3.2-56 43 B 3.3.2-57 43 B 3.3.3-1 0
B 3.3.3-2 5
B 3.3.3-3 0
B 3.3.3-4 0
B 3.3.3-5 0
B 3.3.3-6 8
B 3.3.3-7 21 B 3.3.3-8 8
B 3.3.3-9 8
B 3.3.3-10 19 83.3.3-11 19 B 3.3.3-12 21 B 3.3.3-13 21 B 3.3.3-14 8
B 3.3.3-15 8
B 3.3.4-1 0
B 3.3.4-2 9
B 3.3.4-3 15 B 3.3.4-4 19 B 3.3.4-5 1
B 3.3.4-6 9
B 3.3.5-1 0
B 3.3.5-2 1
B 3.3.5-3 1
Wolf Creek - Unit 1 CHANGE DOCUMENT (3>
DATE EFFECTIVE/
IMPLEMENTED <4>
ORR 11-0724 Amend. No. 123 Amend. No. 123 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 06-0800 ORR 04-1533 Amend. No. 187 (ETS)
Amend. No. 187 (ETS)
ORR 04-1533 ORR 04-1533 ORR 04-1533 ORR 11-2394 ORR 09-1416 ORR 08-0503 ORR 04-1533 ORR 04-1533 ORR 09-1416 ORR 09-1416 ORR 09-1416 ORR 09-1416 ORR 09-1416 ORR 09-1416 ORR 09-1416 V
Amend. No. 123 ORR 00-1427 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 01-1235 ORR 05-0707 ORR 01-1235 ORR 01-1235 ORR 04-1414 ORR 04-1414 ORR 05-0707 ORR 05-0707 ORR 01-1235 ORR 01-1235 Amend. No. 123 ORR 02-1023 ORR 03-0860 ORR 04-1414 ORR 99-1624 ORR 02-0123 Amend. No. 123 ORR 99-1624 ORR 99-1624 4/11/11 12/18/99 12/18/99 2/16/05 2/16/05 2/16/05 2/16/05 5/18/06 2/16/05 3/5/10 3/5/10 2/16/05 2/16/05 2/16/05 11/16/11 9/2/09 4/8/08 2/16/05 2/16/05 9/2/09 9/2/09 9/2/09 9/2/09 9/2/09 9/2/09 9/2/09 12/18/99 10/12/00 12/18/99 12/18/99 12/18/99 9/19/01 4/20/05 9/19/01 9/19/01 10/12/04 10/12/04 4/20/05 4/20/05 9/19/01 9/19/01 12/18/99 2/28/02 7/10/03 10/12/04 12/18/99 2/28/02 12/18/99 12/18/99 12/18/99 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB-B 3.3 INSTRUMENTATION (continued)
B 3.3.5-4 1
B 3.3.5-5 0
B 3.3.5-6 22 B 3.3.5-7 22 B 3.3.6-1 0
B 3.3.6-2 0
B 3.3.6 0 B 3.3.6-4 0
B 3.3.6-5 0
B 3.3.6-6 0
B 3.3.6-7 0
B 3.3.7-1 0
B 3.3.7-2 57 B 3.3.7-3 57 B 3.3.7-4 0
B 3.3.7-5 0
B 3.3.7-6 57 B 3.3.7-7 0
B 3.3.7-8 0
B 3.3.8-1 0
B 3.3.8-2 0
B 3.3.8-3 57 B 3.3.8-4 57 B 3.3.8-5 0
B 3.3.8-6 24 B 3.3.8-7 0
TAB-B 3.4 REACTOR COOLANT SYSTEM (RCS)
B3.4.1-1 0
B 3.4.1-2 10 B3.4.1-3 10 B 3.4.1-4 0
B 3.4.1-5 0
B3.4.1~
0 B 3.4.2-1 0
B 3.4.2-2 0
B 3.4.2-3 O-B 3.4.3-1 67 B 3.4.3-2 0
B 3.4.3-3 0
B 3.4.3-4 0
B 3.4.3-5 0
B 3.4.3-6 0
B 3.4.3-7 0
B 3.4.4-1 0
B 3.4.4-2 29 B 3.4.4-3 0
B 3.4.5-1 0
B 3.4.5-2 53 B 3.4.5-3 29 B 3.4.5-4 12 Wolf Creek - Unit 1 CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
DRR 99-1624 Amend. No. 123 DRR 05-1375 DRR 05-1375 Amend. No. 123
-Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 vi DRR 13-0006 DRR 13-0006 Amend. No. 123 Amend. No. 123 DRR 13-0006 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 13-0006 DRR 13-0006 Amend. No. 123 DRR 06-0051 Amend. No. 123 Amend. No. 123 DRR 02-0411 DRR 02-0411 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 15-0116 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 06-1984 Amend. No. 123 Amend. No. 123 ORR 11-1513 DRR 06-1984 DRR 02-1062 12/18/99 12/18/99 6/28/05 6/28/05 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 1/16/13 1/16/13 12/18/99 12/18/99 1/16/13 12/18/99 12/18/99 12/18/99 12/18/99 1/16/13 1/16/13 12/18/99 2/28/06 12/18/99 12/18/99 4/5/02 4/5/02 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 2/10/15 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 10/17/06 12/18/99 12/18/99 7/18/11 10/17/06 9/26/02 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2l CHANGE DOCUMENT <3l DATE EFFECTIVE/
IMPLEMENTED <4l TAB - B 3.4 REACTOR COOLANT SYSTEM (RCS) (continued)
B 3.4.5-5 12 ORR 02-1062 B 3.4.5-6 12 ORR 02-1062 B 3.4.6-1 53 ORR 11-1513 B 3.4.6-2 72 ORR 15-1918 B 3.4.6-3 12 ORR 02-1062 B 3.4.6-4 72 DRR 15-1918 B 3.4.6-5 75 ORR 16-1909 B 3.4.6-6 75 ORR 16-1909 B 3.4.7-1 12 ORR 02-1062 B 3.4.7-2 17 ORR 04-0453 B 3.4.7-3 77 ORR 17-1001 B 3.4.7-4 42 ORR 09-1009 B 3.4.7-5 72 DRR 15-1918 B 3.4.7-6 75 ORR 16-1909 B 3.4.8-1 53 DRR 11-1513 B 3.4.8-2 77 ORR 17-1001 B 3.4.8-3 42 ORR 09-1009 B 3.4.8-4 75 ORR 16-1909 B 3.4.8-5 72 ORR 15-1918 B 3.4.9-1 0
Amend. No. 123 B 3.4.9-2 0
Amend. No. 123 B 3.4.9-3 0
Amend. No. 123 B 3.4.9-4 0
Amend. No. 123 B 3.4.10-1 5
ORR 00-1427 B3.4.1~2 5
DRR0~1427 B 3.4.10-3 0
Amend. No. 123 B 3.4.10-4 32 ORR 07-0139 B 3.4.11-1 0
Amend. No. 123 B 3.4.11-2 1
DRR 99-1624 B 3.4.11-3 19 ORR 04-1414 B 3.4.11-4 0
Amend. No. 123 B3.4.11-5 1
DRR99-1624 B 3.4.11-6 0
Amend. No. 123 B3.4.11-7 32 DRR07-0139 B 3.4.12-1 61 DRR 14-0346 B 3.4.12-2 61 DRR 14-0346 B 3.4.12-3 0
Amend. No. 123 B 3.4.12-4 61 ORR 14-0346 B 3.4.12-5 61 ORR 14-0346 B 3.4.12-6 56 ORR 12-1792 B 3.4.12-7 61 ORR 14-0346 B3.4.12-8 1
DRR99-1624 B 3.4.12-9 56 ORR 12-1792 B 3.4.12-10 0
Amend. No. 123 B 3.4.12-11 61 ORR 14-0346 B 3.4.12-12 32 ORR 07-0139 B 3.4.12-13 0
Amend. No. 123 B 3.4.12-14 32 ORR 07-0139 B 3.4.13-1 0
Amend. No. 123 B 3.4.13-2 29 ORR 06-1984 B 3.4.13-3 29 ORR 06-1984 Wolf Creek - Unit 1 vii 9/26/02 9/26/02 7/18/11 10/26/15 9/26/02 10/26/15 10/26/16 10/26/16 9/26/02 5/26/04 6/22/17 7/16/09 10/26/15 10/26/16 7/18/11 6/22/17 7/16/09 10/26/16 10/26/15 12/18/99 12/18/99 12/18/99 12/18/99 10/12/00 10/12/00 12/18/99 2/7/07 12/18/99 12/18/99 10/12/04 12/18/99 12/18/99 12/18/99 2/7/07 2/27/14 2/27/14 12/18/99 2/27/14 2/27/14 11/7/12 2/27/14 12/18/99 11/7/12 12/18/99 2/27/14 2/7/07 12/18/99 2/7/07 12/18/99 10/17/06 10/17/06 Revision77 j
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1>
REVISION NO. (2>
CHANGE DOCUMENT (3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB-B 3.4 REACTOR COOLANT SYSTEM (RCS) (continued)
B 3.4.13-4 35 ORR 07-1553 B 3.4.13-5 35 ORR 07-1553 B 3.4.13-6 29 ORR 06-1984 B 3.4.14-1 0
Amend. No. 123 B 3.4.14-2 0
Amend. No. 123 B 3.4.14-3 0
Amend. No. 123 B 3.4.14-4 0
Amend. No. 123 B 3.4.14-5 32 ORR 07-0139 B 3.4.14-6 32 ORR 07-0139 B 3.4.15-1 31 ORR 06-2494 B 3.4.15-2 31 ORR 06-2494 B 3.4.15-3 33 ORR 07-0656 B 3.4.15-4 33 ORR 07-0656 B 3.4.15-5 65 ORR 14-2146 B 3.4.15-6 31 ORR 06-2494 B 3.4.15-7 31 ORR 06-2494 B 3.4.15-8 31 ORR 06-2494 B 3.4.16-1 31 ORR 06-2494 B 3.4.16-2 31 ORR 06-2494 B 3.4.16-3 31 ORR 06-2494 B 3.4.16-4 31 ORR 06-2494 B 3.4.16-5 31 ORR 06-2494 B 3.4.17-1 29 ORR 06-1984 B 3.4.17-2 58 ORR 13-0369 B 3.4.17-3 52 ORR 11-0724 B 3.4.17-4 57 ORR 13-0006 B 3.4.17-5 57 ORR 13-0006 B 3.4.17-6 57 ORR 13-0006 B 3.4.17-7 58 ORR 13-0369 TAB - B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS)
B 3.5.1-1 0
Amend. No. 123 B 3.5.1-2 0
Amend. No. 123 B 3.5.1-3 73 ORR 15-2135 B 3.5.1-4 73 ORR 15-2135 B 3.5.1-5 1
ORR 99-1624 B 3.5.1-6 1
ORR 99-1624 B 3.5.1-7 71 ORR 15-1528 B 3.5.1-8 1
ORR 99-1624 B 3.5.2-1 0
Amend. No. 123 B 3.5.2-2 0
Amend. No. 123 B 3.5.2-3 0
Amend. No. 123 B 3.5.2-4 0
Amend. No. 123 B 3.5.2-5 72 ORR 15-1918 B 3.5.2-6 42 ORR 09-1009 B 3.5.2-7 42 ORR 09-1009 B 3.5.2-8 72 ORR 15-1918 B 3.5.2-9 75 ORR 16-1909 B 3.5.2-10 72 ORR 15-1918 B 3.5.2-11 72 ORR 15-1918 B 3.5.2-12 72 ORR 15-1918 Wolf Creek - Unit 1 viii 9/28/07 9/28/07 10/17/06 12/18/99 12/18/99 12/18/99 12/18/99 217107 217107 12/13/06 12/13/06 5/1/07 5/1/07 9/30/14 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 12/13/06 10/17/06 02/26/13 4/11 /11 1/16/13 1/16/13 1/16/13 02/26/13 12/18/99 12/18/99 11/17/15 11/17/15 12/18/99 12/18/99 7/30/15 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 10/26/15 7/16/09 7/16/09 10/26/15 10/26/16 10/26/15 10/26/15 10/26/15 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB - B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) (continued)
B 3.5.3-1 B 3.5.3-2 B 3.5.3-3 B 3.5.3-4 B 3.5.4-1 B 3.5.4-2 B 3.5.4-3 B 3.5.4-4 B 3.5.4-5 B 3.5.4-6 B 3.5.5-1 B 3.5.5-2 B 3.5.5-3 B 3.5.5-4 56 DRR 12-1792 72 DRR 15-1918 56 DRR 12-1792 56 DRR 12-1792 0
Amend. No. 123 0
Amend. No. 123 0
Amend. No. 123 0
Amend. No. 123 0
Amend. No. 123 26 DRR 06-1350 21 DRR 05-0707 21 DRR 05-0707 2
Amend. No. 132 21 DRR 05-0707 TAB - B 3.6 CONTAINMENT SYSTEMS B 3.6.1-1 0
B 3.6.1-2 0
B 3.6.1-3 0
B 3.6.1-4 17 B 3.6.2-1 0
B 3.6.2-2 0
B 3.6.2-3 0
B 3.6.2-4 0
B 3.6.2-5 0
B 3.6.2-6 0
B 3.6.2-7 0
B 3.6.3-1 0
B 3.6.3-2 0
B 3.6.3-3 0
B 3.6.3-4 49 B 3.6.3-5 49 B 3.6.3-6 49 B 3.6.3-7 41 B 3.6.3-8 36 B 3.6.3-9 36 B 3.6.3-10 8
B 3.6.3-11 36 B 3.6.3-12 36 83.6.3~13 50 B 3.6.3-14 36 83.6.3-15 39 B 3.6.3-16 39 B 3.6.3-17 36 83.6.3-18 36 B 3.6.3-19 36 B 3.6.4-1 39 B 3.6.4-2 0
B 3.6.4-3 0
B 3.6.5-1 0
B 3.6.5-2 37 Wolf Creek - Unit 1 ix Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 04-0453 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 DRR 11-0014 DRR 11-0014 DRR 11-0014 DRR 09-0288 DRR 08-0255 DRR 08-0255 DRR 01-1235 DRR 08-0255 DRR 08-0255 DRR 11-0449 DRR 08-0255 DRR 08-1096 DRR 08-1096 DRR 08-0255 DRR 08-0255 DRR 08-0255 ORR 08-1096 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 08-0503 11/7/12 10/26/15 11/7/12 11/7/12 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 7/24/06 4/20/05 4/20/05 4/24/00 4/20/05 12/18/99 12/18/99 12/18/99 5/26/04 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 1/31/11 1/31/11 1/31/11 3/20/09 3/11/08 3/11/08 9/19/01 3/11/08 3/11/08 3/9/11 3/11/08 8/28/08 8/28/08 3/11/08 3/11/08 3/11/08 8/28/08 12/18/99 12/18/99 12/18/99 4/8/08 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE'1>
REVISION NO. '2>
TAB-B 3.6 CONTAINMENT SYSTEMS (continued)
B 3.6.5-3 13 B 3.6.5-4 0
B 3.6.6-1 42 B 3.6.6-2 63 B 3.6.6-3 37 B 3.6.6-4 72 B 3.6.6-5 0
B 3.6.6-6 18 B 3.6.6-7 72 B 3.6.6-8 72 B 3.6.6-9 72 B 3.6.6-10 75 B 3.6.6.11 75 B 3.6.7-1 0
B 3.6.7-2 42 B 3.6.7-3 0
B 3.6.7-4 29 B 3.6.7-5 42 TAB - B 3.7 PLANT SYSTEMS B 3.7.1-1 0
B 3.7.1-2 0
B 3.7.1-3 0
B3.7.1-4 0
B 3.7.1-5 32 B 3.7.1-6 32 B 3.7.2-1 44 B 3.7.2-2 44 B 3.7.2-3 44 B 3.7.2-4 44 B 3.7.2-5 44 B 3.7.2-6 44 B 3.7.2-7 44 B 3.7.2-8 44 B 3.7.2-9 44 B 3.7.2-10 44 B3.7.2-11 44 B 3.7.3-1 37 B 3.7.3-2 50 B 3.7.3-3 37 B 3.7.3-4 37 B 3.7.3-5 37 B 3.7.3-6 37 B 3.7.3-7 37 B 3.7.3-8 37 B 3.7.3-9 66 B 3.7.3-10 66 B3.7.3-11 37 B 3.7.4-1 1
B 3.7.4-2 1
B 3.7.4-3 19 Wolf Creek - Unit 1 CHANGE DOCUMENT (3>
DATE EFFECTIVE/
IMPLEMENTED (4>
X ORR 02-1458 Amend. No. 123 ORR 09-1009 ORR 14-1572 ORR 08-0503 ORR 15-1918 Amend. No. 123 ORR 04-1018 ORR 15-1918 ORR 15-1918 ORR 15-1918 ORR 16-1909 ORR 16-1909 Amend. No. 123 ORR 09-1009 Amend. No. 123 ORR 06-1984 ORR 09-1009 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 07-0139 ORR 07-0139 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 09-1744 ORR 08-0503 ORR 11-0449 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 08-0503 ORR 14-2329 ORR 14-2329 ORR 08-0503 ORR 99-1624 ORR 99-1624 ORR 04-1414 12/03/02 12/18/99 7/16/09 7/1/14 4/8/08 10/26/15 12/18/99 9/1/04 10/26/15 10/26/15 10/26/15 10/26/16 10/26/16 12/18/99 7/16/09 12/18/99 10/17/06 7/16/09 12/18/99 12/18/99 12/18/99 12/18/99 2/7/07 2/7/07 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 10/28/09 4/8/08 3/9/11 4/8/08 4/8/08 4/8/08 4/8/08 4/8/08 4/8/08 11/6/14 11/6/14 4/8/08 12/18/99 12/18/99 10/12/04 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
TAB-B 3.7 PLANT SYSTEMS (continued) 83.7.4-4 19 B 3.7.4-5 1
B 3.7.5-1 54 B 3.7.5-2 54 B 3.7.5-3 0
B 3.7.5-4 76 B 3.7.5-5 76 B 3.7.5-6 76 B 3.7.5-7 76 B 3.7.5-8 76 B 3.7.5-9 76 B 3.7.6-1 0
B 3.7.6-2 0
B 3.7.6-3 0
B 3.7.7-1 0
B 3.7.7-2 77 B 3.7.7-3 0
83.7.7-4 1
B 3.7.8-1 0
B 3.7.8-2 0
B 3.7.8-3 0
B 3.7.8-4 0
B 3.7.8-5 0
B 3.7.9-1 3
B 3.7.9-2 3
B 3.7.9-3 3
B 3.7.9-4 3
B 3.7.10-1 64 B 3.7.10-2 41 B 3.7.10-3 41 B 3.7.10-4 41 B 3.7.10-5 57 B 3.7.10-6 57 B 3.7.10-7 64 B 3. 7.1 0-8 41 B 3.7.10-9 64 B 3.7.11-1 0
83.7.11-2 57 B 3.7.11-3 63 B 3.7.11-4 63 B 3.7.12-1 0
83.7.13-1 24 B 3.7.13-2 1
B 3.7.13-3 75 B 3.7.13-4 57 B 3.7.13-5 57 B 3.7.13-6 64 B 3.7.13-7 64 B 3.7.13-8 64 B3.7.14-1 0
B 3.7.15-1 0
Wolf Creek - Unit 1 CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
xi ORR 04-1414 ORR 99-1624 ORR 11-2394 ORR 11-2394 Amend. No. 123 ORR 17-0343 ORR 17-0343 ORR 17-0343 ORR 17-0343 ORR 17-0343 ORR 17-0343 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 17-1001 Amend. No. 123 ORR 99-1624 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 123 Amend. No. 134 Amend. No. 134 Amend. No. 134 Amend. No. 134 ORR 14-1822 ORR 09-0288 ORR 09-0288 ORR 09-0288 ORR 13-0006 ORR 13-0006 ORR 14-1822 ORR 09-0288 ORR 14-1822 Amend. No. 123 ORR 13-0006 ORR 14-1572 ORR 14-1572 Amend. No. 123 ORR 06-0051 ORR 99-1624 ORR 16-1909 ORR 13-0006 ORR 13-0006 ORR 14-1822 ORR 14-1822 ORR 14-1822 Amend. No. 123 Amend. No. 123 10/12/04 12/18/99 11/16/11 11/16/11 12/18/99 2/21/17 2/21/17 2/21/17 2/21/17 2/21/17 2/21/17 12/18/99 12/18/99 12/18/99 12/18/99 6/22/17 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 7/14/00 7/14/00 7/14/00 7/14/00 8/28/14 3/20/09 3/20/09 3/20/09 1/16/13 1/16/13 8/28/14 3/20/09 8/28/14 12/18/99 1/16/13 7/1/14 7/1/14 12/18/99 2/28/06 12/18/99 7/16/09 1/16/13 1/16/13 8/28/14 8/28/14 8/28/14 12/18/99 12/18/99 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB-B 3.7 PLANT SYSTEMS {continued}
B3.7.15-2 0
Amend. No. 123 12/18/99 B 3.7.15-3 0
Amend. No. 123 12/18/99 B 3.7.16-1 5
DRR 00-1427 10/12/00 B 3.7.16-2 23 DRR 05-1995 9/28/05 B 3.7.16-3 5
DRR 00-1427 10/12/00 B 3.7.17-1 7
DRR 01-0474 5/1/01 B 3.7.17-2 7
DRR 01-0474 5/1/01 B 3.7.17-3 5
DRR 00-1427 10/12/00 B 3.7.18-1 0
Amend. No. 123 12/18/99 B 3.7.18-2 0
Amend. No. 123 12/18/99 B 3.7.18-3 0
Amend. No. 123 12/18/99 B 3.7.19-1 44 DRR 09-1744 10/28/09 B 3.7.19-2 54 DRR 11-2394 11/16/11 B 3.7.19-3 54 DRR 11-2394 11/16/11 B 3.7.19-4 61 DRR 14-0346 2/27/14 B 3.7.19-5 61 DRR 14-0346 2/27/14 B 3.7.19-6 54 DRR 11-2394 11/16/11 B 3.7.19-7 54 DRR 11-2394 11/16/11 TAB-B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.1-1 54 DRR 11-2394 11/16/11 B 3.8.1-2 0
Amend. No. 123 12/18/99 B 3.8.1-3 75 DRR 16-1909 10/26/16 B 3.8.1-4 71 DRR 15-1528 7/30/15 B 3.8.1-5 59 DRR 13-1524 6/26/13 B 3.8.1-6 25 DRR 06-0800 5/18/06 B 3.8.1-7 26 DRR 06-1350 7/24/06 B 3.8.1-8 35 DRR 07-1553 9/28/07 B 3.8.1-9 42 DRR 09-1009 7/16/09 B 3.8.1-10 39 DRR 08-1096 8/28/08 B 3.8.1-11 36 DRR 08-0255 3/11/08 B 3.8.1-12 75 DRR 16-1909 10/26/16 B 3.8.1-13 47 DRR 10-1089 6/16/10 B 3.8.1-14 47 DRR 10-1089 6/16/10 B 3.8.1-15 47 DRR 10-1089 6/16/10 B 3.8.1-16 26 DRR 06-1350 7/24/06 B 3.8.1-17 26 DRR 06-1350 7/24/06 B 3.8.1-18 59 DRR 13-1524 6/26/13 B 3.8.1-19 26 DRR 06-1350 7/24/06 B 3.8.1-20 26 DRR 06-1350 7/24/06 B 3.8.1-21 33 DRR 07-0656 5/1/07 B 3.8.1-22 33 DRR 07-0656 5/1/07 B 3.8.1-23 74 ORR 16-1182 7/7/16 B 3.8.1-24 74 ORR 16-1182 7/7/16 B 3.8.1-25 74 ORR 16-1182 7/7/16 B 3.8.1-26 74 ORR 16-1182 7/7/16 B 3.8.1-27 74 ORR 16-1182 7/7/16 B 3.8.1-28 74 ORR 16-1182 7/7/16 B 3.8.1-29 74 ORR 16-1182 7/7/16 B 3.8.1-30 74 ORR 16-1182 7/7/16 B 3.8.1-31 74 ORR 16-1182 7/7/16 Wolf Creek - Unit 1 xii Revision??
LIST OF EFFECTIVE PAGES -TECHNICAL SPECIFICATION BASES PAGE<1l REVISION NO. <2l CHANGE DOCUMENT <3)
DATE EFFECTIVE/
IMPLEMENTED <4)
TAB-B 3.8 ELECTRICAL POWER SYSTEMS (continued)
B 3.8.1-32 74 ORR 16-1182 B 3.8.1-33 74 ORR 16-1182 B 3.8.1-34 74 ORR 16-1182 B 3.8.2-1 57 ORR 13-0006 B 3.8.2-2 0
Amend. No. 123 B 3.8.2-3 0
Amend. No. 123 B 3.8.2-4 57 ORR 13-0006 B 3.8.2-5 57 ORR 13-0006 B 3.8.2-6 57 ORR 13-0006 B 3.8.2-7 57 ORR 13-0006 B 3.8.3-1 1
ORR 99-1624 B 3.8.3-2 0
Amend. No. 123 B 3.8.3-3 0
Amend. No. 123 B 3.8.3-4 1
ORR 99-1624 B 3.8.3-5 0
Amend. No. 123 B 3.8.3-6 0
Amend. No. 123 B 3.8.3-7 12 ORR 02-1062 B 3.8.3-8 1
ORR 99-1624 B 3.8.3-9 0
Amend. No. 123 B 3.8.4-1 0
Amend. No. 123 B 3.8.4-2 0
Amend. No. 123 B 3.8.4-3 0
Amend. No. 123 B 3.8.4-4 0
Amend. No. 123 B 3. 8.4-5 50 D RR 11-0449 B 3.8.4-6 50 ORR 11-0449 B 3.8.4-7 6
ORR 00-1541 B 3.8.4-8 0
Amend. No. 123 B 3.8.4-9 2
ORR 00-0147 B 3.8.5-1 57 ORR 13-0006 B 3.8.5-2 0
Amend. No. 123 B 3.8.5-3 57 ORR 13-0006 B 3.8.5-4 57 ORR 13-0006 B 3.8.5-5 57 ORR 13-0006 B 3.8.6-1 0
Amend. No. 123 B 3.8.6-2 0
Amend. No. 123 B 3.8.6-3 0
Amend. No. 123 B 3.8.6-4 0
Amend. No. 123 B 3.8.6-5 0
Amend. No. 123 B 3.8.6-6 0
Amend. No. 123 B 3.8.7-1 69 ORR 15-0493 B 3.8.7-2 69 ORR 15-0493 B 3.8.7-3 69 ORR 15-0493 B 3.8.7-4 0
Amend. No. 123 B 3.8.8-1 57 ORR 13-0006 B 3.8.8-2 0
Amend. No. 123 B 3.8.8-3 69 ORR 15-0493 B 3.8.8-4 57 ORR 13-0006 B 3.8.8-5 69 ORR 15-0493 B 3.8.9-1 54 ORR 11-2394 B 3.8.9-2 69 ORR 15-0493 B 3.8.9-3 54 ORR 11-2394 Wolf Creek - Unit 1 xiii 7/7/16 7/7/16 717/16 1/16/13 12/18/99 12/18/99 1/16/13 1/16/13 1/16/13 1 /16/13 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 9/26/02 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 3/9/11 3/9/11 3/13/01 12/18/99 4/24/00 1/16/13 12/18/99 1/16/13 1/16/13 1/16/13 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 12/18/99 3/26/15 3/26/15 3/26/15 12/18/99 1/16/13 12/18/99 3/26/15 1/16/13 3/26/15 11/16/11 3/26/15 11/16/11 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE<1>
REVISION NO. <2>
CHANGE DOCUMENT <3>
DATE EFFECTIVE/
IMPLEMENTED <4>
TAB-B 3.8 ELECTRICAL POWER SYSTEMS (continued)
B 3.8.9-4 0
Amend. No. 123 B 3.8.9-5 69 ORR 15-0493 B 3.8.9-6 0
Amend. No. 123 B 3.8.9-7 0
Amend. No. 123 B 3.8.9-8 1
ORR 99-1624 B 3.8.9-9 0
Amend. No. 123 B 3.8.10-1 57 ORR 13-0006 B 3.8.10-2 0
Amend. No. 123 B 3.8.10-3 0
Amend. No. 123 B 3.8.10-4 57 ORR 13-0006 B 3.8.10-5 57 ORR 13-0006 B 3.8.10-6 57 ORR 13-0006 TAB-B 3.9 REFUELING OPERATIONS B 3.9.1-1 0
B 3.9.1-2 19 B 3.9.1-3 19 B 3.9.1-4 19 B 3.9.2-1 0
B 3.9.2-2 0
B 3.9.2-3 0
B 3.9.3-1 68 B 3.9.3-2 68 B 3.9.3-3 51 B 3.9.3-4 68 B 3.9.4-1 23 B 3.9.4-2 13 B 3.9.4-3 25 B 3.9.4-4 23 B 3.9.4-5 33 B 3.9.4-6 23 B 3.9.5-1 0
B 3.9.5-2 72 B 3.9.5-3 32 B 3.9.5-4 75 B 3.9.5-5 75 B 3.9.6-1 0
B 3.9.6-2 72 B 3.9.6-3 42 B 3.9.6-4 72 B 3.9.6-5 75 B 3.9.7-1 25 B 3.9.7-2 0
B 3.9.7-3 0
Wolf Creek - Unit 1 Amend. No. 123 ORR 04-1414 ORR 04-1414 ORR 04-1414 Amend. No. 123 Amend. No. 123 Amend. No. 123 ORR 15-0248 DRR 15-0248 ORR 11-0664 ORR 15-0248 ORR 05-1995 ORR 02-1458 ORR 06-0800 ORR 05-1995 ORR 07-0656 ORR 05-1995 Amend. No. 123 ORR 15-1918 ORR 07-0139 ORR 16-1909 ORR 16-1909 Amend. No. 123 ORR 15-1918 ORR 09-1009 ORR 15-1918 ORR 16-1909 ORR 06-0800 Amend. No. 123 Amend. No. 123 xiv 12/18/99 3/26/15 12/18/99 12/18/99 12/18/99 12/18/99 1/16/13 12/18/99 12/18/99 1 /16/13 1/16/13 1/16/13 12/18/99 10/12/04 10/12/04 10/12/04 12/18/99 12/18/99 12/18/99 2/26/15 2/26/15 3/21/11 2/26/15 9/28/05 12/03/02 5/18/06 9/28/05 5/1/07 9/28/05 12/18/99 10/26/15 2/7/07 10/26/16 10/26/16 12/18/99 10/26/15 7/16/09 10/26/15 10/26/16 5/18/06 12/18/99 12/18/99 Revision??
LIST OF EFFECTIVE PAGES - TECHNICAL SPECIFICATION BASES PAGE(1)
REVISION NO. (Z)
CHANGE DOCUMENT (3)
DATE EFFECTIVE/
IMPLEMENTED (4)
Note 1 The page number is listed on the center of the bottom of each page.
Note 2 The revision number is listed in the lower right hand corner of each page. The Revision number will be page specific.
Note 3 The change document will be the document requesting the change. Amendment No.
123 issued the improved Technical Specifications and associated Bases which affected each page. The NRC has indicated that Bases changes will not be issued with License Amendments. Therefore, the change document should be a ORR number in accordance with AP 26A-002.
Note 4 The date effective or implemented is the date the Bases pages are issued by Document Control.
Wolf Creek - Unit 1 xv Revision77