Forwards SE Accepting Alternative to 10CFR50.55a(g)(6)(ii)(A) Augmented RPV Exam for Plant, Provided by Util 961122 & s
ML18068A716
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 10/23/1998
From: Richards S
NRC (Affiliation Not Assigned)
To: Kingsley O
COMMONWEALTH EDISON CO.
Shared Package
ML18068A717 List:
References
TAC-M97370, TAC-M99659, NUDOCS 9811020058
Download: ML18068A716 (4)


Text

'.

Mr. Oliver D. Kingsley, President Nuclear Generation Group Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 October 23, 1998

SUBJECT:

ALTERNATIVE TO 10 CFR 50.55a(g)(6)(ii)(A) AUGMENTED REACTOR PRESSURE VESSEL EXAMINATION FOR QUAD CITIES NUCLEAR PLANT, UNITS 1AND2 (TAC NOS. M97370 AND M99659)

Dear Mr. Kingsley:

The NRG staff has reviewed and evaluated the information provided by the Commonwealth Edison Company in its letter dated. November 22, 1996, and in its request for additional information response dated April 14, 1997, for Unit 1 and letter dated September 18, 1997, for Unit 2. Supplemental information dated August 21, 1998, was also provided for Units 1 and 2 and reviewed by the staff. These letters were submitted regarding the alternative to 10 CFR 50.55a(g)(6)(ii)(A), augmented reactor pressure vessel examination, for Quad Cities Nuclear Plant, Units 1 and 2..The staff authorizes the licensee's proposed alternative to augmented examination of reactor pressure vessel pursuant to 10 CFR 50.55a(a)(3)(i).

, The staff's evaluation and conclusions are contained in the enclosed safety evaluation (SE).

This task completes TAC Nos. M97370 and M99659.

Sincerely, ORIGINAL SIGNED BY:

------901102oosef 901023

--~ *-----~,

PDR ADOCK 05000254 Stuart A. Richards, Director Project Directorate 111-2 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation I

p PDR Docket Nos. 50-254, 50-265

Enclosure:

SE cc w/encl: See next page DISTRIBUTION:

\\ioom~

PUBLIC PDlll-2 r/f.

S. Richards C. Moore R. Pulsifer ACRS, T2E26 MRing, Rill DOCUMENT NAME: G:\\CM\\QUAD\\QC97370.RLF E. Adensam, EGA 1 OGG, 015B18 To receive a copy of this document, indica i the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE PM:PDlll-2 NAME DATE 10/ 7' I

,.\\,...... *;. ""i

..,,. ' ' ', l I

t

.._) "-"

0 D:PDlll-2 SRICHARDS~

10/)

198

UNITED STATES NUCLEAR REGULATORY COMMISSION Mr. Oliver D. Kingsley, President Nuclear Generation Group Commonwealth Edison*Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 WASHINGTON, D.C. 20555-0001 October 23. 1998

SUBJECT:

ALTERNATIVE TO 10 CFR 50.55a(g)(6)(ii)(A) AUGMENTED REACTOR PRESSURE VESSEL EXAMINATION FOR QUAD CITIES NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. M97370 AND M99659)

Dear Mr. Kingsley:

The NRC staff has reviewed and evaluated the information provided by the Commonwealth Edison Company in its letter dated November 22, 1996, and in its request for additional information response dated April 14, 1997, for Unit 1 and letter dated September 18, 1997, for Unit 2. Supplemental information dated August 21, 1998, was also provided for Units 1 and 2 and reviewed by the staff. These letters were submitted regarding the alternative to 10 CFR 50.55a(g)(6)(ii)(A), augmented reactor pressure vessel examination, for Quad Cities Nuclear Plant, Units 1 and 2. The staff authorizes the licensee's proposed alternative to augmented examination of reactor pressure vessel pursuant to 10 CFR 50.55a(a)(3)(i).

The staff's evaluation and conclusions are contained in the enclosed safety evaluation (SE).

This task completes TAC Nos. M97370 and M99659.

Docket Nos. 50-254, 50-265

Enclosure:

SE cc w/encl: See next page Sincerely, Stuart A. Richards, Director Project Directorate 111-2 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation.

-***-*-- --*** ~-*-~* -* -.

---*~*:.. ___..,_,.. -.,.:. ___._...._...__.,_,. __ ~........... **-*----**-*****--.--**. ****'-** *--~ ------ *-- -*-**

e e

0. Kingsley Commonwealth Edison Company cc:

Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603 Commonwealth Edison Company Quad Cities Station Manager 22710 206th Av.enue N.

Cordova, Illinois 61242-9740 U.S. Nuclear Regulatory Commission Quad Cities Resident Inspectors Office 22712 206th Avenue N.

Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator

  • U.S. NRC, Region Ill 801 Warrenville Road Lisle, Illinois 60532-4351 William D. Leach Manager - Nuclear MidAmerican Energy Company 907 Walnut Street P.O. Box657 Des Moines, Iowa 50303 Vice President - Law and Regulatory Affairs MidAmerican Energy Company One River Center Place 106 E. Second Street P.O. Box 4350 Davenport, Iowa 52808 Quad Cities Nuclear Power Station
  • Units 1 and 2 Commonwealth *Edison Company Site Vice President - Quad Cities 22710 206th Avenue N.

Cordova, Illinois 61242-9740 Document Control Desk-Licensing Commonwealth Edison Company 1400 Opus Place, Suite 400 Downers Grove, Illinois 60515 Mr. David Helwig Senior Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515 Mr. Gene H. Stanley PWR's Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL. 60515 Mr. Steve Perry BWR's Vice President Commonwealth Edison Co_mpany Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515 Mr. Dennis Farrar Regulatory Services Manager Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 Ms. Irene Johnson, Licensing Director Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515

0. Kingsley Commonwealth Edison Company

,.r Commonwealth Edison Company Reg. Assurance Supervisor - Quad Cities 2271 O 206th Avenue N.

Cordova, Illinois 61242-9740 Mr. Michael J. Wallace Senior Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515 Quad Cities Nuclear Power Plant Units 1and2