consumers
- Power POW ERIN&
MICHl&AN'S PRO&RESS Palisades Nuclear Plant:
27780 Blue Star Memorial Highway, Covert, Ml 49043 April 20, 1993 Nuclear Regulatory Commission
- Document Control Desk Washington, DC 20555 GB Slade General Manager DOCKET 50-255 - LICENSE DPR PALISADES PLANT - CORRECTION OF ATTACHMENT 4 TO RADIAL PEAKING FACTOR TECHNICAL SPECIFICATIONS CHANGE REQUEST (TAC M84793)
It has come to our attention that there is an error in Attachment 4 to the Technical Specifications change request which prop6ses revised radial peaking factors for the upcoming fuel cycle. A corrected copy of that attachment, EA-A~
NL-91-169 Offsite Dose Calculations of Fuel Handling Accident, is enclosed.
lri par~graph 4.4 of the subject attachment, the decay heat fraction for 2 days after shutdown was incorrectly stated to be 0.003.
The correct number is 0.0049. This correction has no effect on the conclusion of the analysis nor on the No Significant Hazard Assessment since the analysis used a decay heat which is higher than would be produced with either of these decay heat fractions.
Paragraph 4.4 has been revised to state the correct number and to clarify the associated discussion.
We request that the revised Attachment 4 be provided to the reviewer with our
- apology for any inconvenience which the error may have caused.
- ~~~
Gerald B Slade General Manager CC Administrator, Region Ill, USNRC Resident-Inspector, Palisades Attachments 260095 9304260245 930420 PDR ADOCK 05000255 P
-r.
- ' *u A CM5 ENER6Y COMPANY
//(}rj
(/II Ii
. * @>~" connmers
~
PDWll' l'flflRIUW M.ua&.tln N0GnSS PALISADES NUCLEAR PLANT ENGINEERING ANALYSIS COVER SHEET EA-A-NL-91-169-01 Total Number of Sheets 14
. Title Off si!e Dose Calculations of Fuel Handling Accident INITIATION AND REVIEW Calculation Status Preliminary Pending Final Superseded Q
Q x
Q Initiated In it Review Method Technically Reviewed Revr Rev Appd Appd CPCo I
Description By Detai 1 Qual By Appd By Date Alt Cale Review Test Bv Date li:>M'&rca
~ '07h rrc-J)
-;?-f !It l'Je,;
fcf) 0 Original Issue
}:11/df ii/l?"L /
/
lfA// bl 1?/% 124~
- i.
1Z I
RC'-.J.~c 1..... -p.. A 4.-'\\
tt:>*
St>W[LF.4!<.j 4Ji'. f'1lo
/
J',11/l'<le-r
'f;.D 1e0ic-c:.~
o.p?.-*:::.?<" 10.\\~
,~1J/(1 ~ l~:
,4//
~_w-3 Do?c.:.y
'-:.<'.'*'-\\
'F""r,,..~+,..,...._
-iJ T/T7~r-Re~-'c~*.1
\\ "'?--< *~ AA I
~
~
~
- n, ISl:>N' t, iC6
~ 4/~J
/41ird_e,,
{._
c\\r,r, fy*
j t:AtJ/d
~
- ,t~,k 1/J-5A3 ""
I
\\
PURPOSE:
The purpose of this analysis is to demonstrate that the offsite radiological doses of a Fuel Handling Accident (FHA), using the Regulatory Guide 1.25 source term, will be within the limits of 10 CFR 100 as defined in the Standard Review Plan 15.7.4. This analysis accounts for increased radial peaking for Cycle 11, as well as potential future increases in radial peaking factor up to a value of 1.8 for the peak assembly.
SUMMARY
OF RESULTS:
The offsite doses from a fuel handling accident were calculated, bounding the maximum radial peaking factors in Cycle 11 and beyond. This was done to accommodate an increase in the peaking factor to 1.76-in Cycle 11. The analysis followed the guidelines and assumptions of
-. Regulatory Guid*e 1.25 and the *standard Review Plan. The resultant doses were calculated to be 41.19 rem thyroid and 0.12 rem whole body for 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> at the site boundary, and 7.23 rem thyroid and 0.02 rem whole body for 30 days at the low population zone distance. These calculated doses are well within the limits of 10 CFR 100, as interpreted by the Standard Review Plan 15.7.4.
(... 9304260249 930420..
- n
. PDR f'DOCK 05000255*
. I p
PDS~*.c i
I
1.0 OBJECTIVE
2.0 REFERENCES
3.0 BACKGROUND
PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET Table of Contents E-A-NL-91-169-01 Sheet _2_ Rev # --=2 __
3 3
4 4.0 ANALYSIS INPUT................................................
4 5.0 ASSUMPI10NS....................................................
6 6.0 ANALYSIS 6
7.0 SIDdMARY 8
1.0 OBJECTIVE PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET E-A-NL-91-169-01 Sheet _3_ Rev # --=2 __
The purpose of this analysis is to demonstrate that the offsite radiological doses of a Fuel Handling Accident (FHA), using the Regulatory Guide 1.25 source term, will be within the limits of 10 CFR 100 as defined in the Standard Review Plan [Ref. 2.1]. This analysis accounts for increased radial peaking for Cycle 11, as well as potential future increases in radial peaking factors up to a value of 1.8.
2.0 REFERENCES
- 2. 1 Regulatory Guide. 1. 25 Rev 2, "Assumptions Used For Evaluating The Potential Radiological Consequences of a Fuel Handling Accident in the Fuel Handling and Storage Facility for Boiling and Pressurized Water Reactors," March 1972.
2.2 NUREG-0800, USNRC Standard Review Plan, Section 15.7.4Rev 1, "Radiological Consequences of Fuel Handling Accidents.
2.3 Letter from D.L. Ziemann (NRC) to D. Bixel (CPCo) dated June 21, 1979.
Subject:
Safety Evaluation by the Office of Nuclear Reactor Regulation Regarding the Fuel Handling Accident Inside. Containment.
Cart/Frame: 2600/0540..
2.4 Letter from D.L. Ziemann (NRC) to D.P. Hoffman (CPCo) dated February 5, 1980.
Subject:
XV Radiological Consequences of Fuel Damaging Accidents (Inside and Outside Containment).
Cart/Frame: 2614/0667.
2.5 NED0-24782, "BWR Owners' Group NUREG-0578 Implementation: Analysis and Positions
- For Plant Unique Submittals," General Electric, August 1980.
2.6
- NUREG/CR-1413 ORNL/NUREG-70, "A Radionuclide Decay Data Base - Index and Summary Table," Oak Ridge National Laboratory, May 1980.
2.7 NUREG/CR-5009 PN-6258, "Assessment of the Use of Extended Bumup Fuel in Lightwater Power Reactors," Pacific Northwest Laboratory.
2.8 ICRP Publication 30, "Limits for Intakes of Radionuclides by Workers," July 1978.
~
2.9 Regulatory Guide 1.4 Rev 2, "Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Pressurized Water Reactors," June 1974.
2.10 Palisades Plant Final Safety Analysis Report.
2.11 Palisades Plant Technical Specifications, Section 3.8.3, through Amendment 153.
2.12 EMF-92-178, "Palisades Cycle 11: Disposition and Analysis of Standard Review Plan Chapter 15 Events," Siemens Power Corporation, November 1992.
PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET E-A-NL-91-169-01 Sheet _4_ Rev # --=2 __
2.13 E-PAH-92-03, "Core Decay Heat Release Fractions Using NRC Branch Technical Position ASB 9-2" 2.14 Letter from H.G. Shaw (Siemens) to R.J. Gerling dated October 6, 1992.
Subject:
Fuel Internal Rod Pressure at End of Life.
3.0 BACKGROUND
The FHA (Fuel Handling Accident) analysis is the bounding radiological consequence analysis for the dropping of a fuel assembly. For an FHA, the source tenns of Regulatory Guide 1.25 [Ref. 2.2]
and Standard Review Plan (SRP) 15. 7.4 [Ref. 2.1] are used. This source tenn amounts to 10% of the assembly iodine, krypton, and xenon found in the gap between the fuel pins and the cladding escaping to the outside atmosphere.
The exception to this is Kr-85, where 30 % escapes to the outside atmosphere.
NUREG/CR-5009 updates the value of escaping I-131 to 12% due to higher fuel bumup.
The limits for offsite dose are 300 rem thyroid and 25 rem whole body, as found in 10 CFR 100; The Standard Review Plan 15. 7.4 [Ref. 2.2] sets the acceptance criteria for a FHA as "appropriately within the guidelines" of 10 CFR 100 and gives the value of 25 % of the 10 CFR 100 limits, or 75 rem thyroid and 6.25 rem whole body. ln Reference 2.3, the dose of 91 rem thyroid is given and deemed acceptable. In Reference 2.4, the limit is given as 100 rem thyroid for Palisades Nuclear Plant. This value is the licensing basis thyroid dose limit for a FHA at Palisades.
4.0 ANALYSIS INPUT 4.1 The breathing rate for offsite doses is 3.47E-4 m 3/sec in accordance with Reference 2.9.
This is the breathing rate given for a person offsite during the first eight hours of the accident. This is also the maximum. breathing rate given, so it is deemed conservative.
4.2 The number of fuel assemblies-in the core, 204, is found in Reference 2.10, Section 3.3.1.
4.2 The rated core thennal power, 2530 MW 0 is from Reference 2.10.
4.3 The assembly radial peaking factor of 1.8 was used for this analysis. The value of 1. 76 is the factor for cycle 11 and can be found in Reference 2.12, but 1. 8 was used to bound radial peaking.
4.4 The decay heat fractional energy release 2 days after shutdown, based on Reference 2.13, is approximately 0.0049. This results in a Linear Heat Generation Rate of 0.026 kW/ft. This LHGR is less than the 0.05 kW/ft used to calculate the fuel rod pressure in Reference 2.14.
Thus, the fuel rod pressure provided in Reference 2.14 is conservative.
4.5 The fuel rod gas pressure is less than 1200 psig based on Reference 2.14. This meets the requirements needed to make the Reference 2.1 assumptions valid. Reference 2.14 can be found as Attachment 8.1.
PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET E-A-NL-91-169-01 Sheet _s_ Rev# -~2 __
4.6 The Pool Decontamination Factors are 100 for iodine and 1 for all other nuclides. This is taken from Reference 2.1 based on Reference 2. 14.
4.7 The radionuclide activities for one day after reactor shutdown were found in Reference 2.5 and are listed in Table 1. For the iodine isotopes, the values in Table 1 are doubled because Reference 2.5 gives 50% of the value needed.
4.8 The radionuclide half lives are found in Reference 2.6 and are listed in Table 1. The values found in Reference 2.6 were converted to minutes before being input into the table.
4.9 The dose conversion factors for the radionuclides are from Reference 2.8, and are listed.in Table 1. The values found were converted to new units before being input into the table.
Table 1 Nuclide Si t 112 Dose Conversion (Ci/MW J (min)
Factors See Note 1-131 2.696E+4 11577.6 1073000 1-132 7.204E+2 138 6290 1-133 2.178E+4 1248 181300 1-134 3.040E-4 52.6 1073 1-135 4.778E+3 396.6 31450 Kr-83m 6.039E+O 109.8
.000003 Kr-85m 1.489E+2 268.8
.03031 Kr-85 2.999E+2 5638291
.000473 Kr-87 2.295E-2 76.3
.1447 Kr-88 4.452E+l 170.4
.369 Xe-131m l.708E+2 17049.6
.001324 Xe-133m-1.547E+3 3153.6
.005375 Xe-133 5.171E+4 7552.8
.006259 Xe-135m 6.693E+2 15.36
.07647 Xe-135 7.388E+3 546.6
.04676 Xe-138 4.830E-27 14.13
.1969 NOTE:
The Dose Conversion Factors are (Rem/Ci) for Iodine and (Rem/sec)/(Ci/m
~ for all other nuclides.
5.0 ASSUMPTIONS PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET E-A-NL-91-169-01 Sheet _6_ Rev# __ 2 __
5.1 The core is assumed to have run at 102 % of rated power, or 2580.6 MW r 5.2 The FHA occurs inside containment, 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after shutdown, as per Reference 2.12. This creates the most severe consequences for a fuel handling accident.
5.3 One fuel assembly is completely damaged as a result of the fuel handling accident.
This is consistent with Reference 2.1.
5.4 The fuel assembly with the peak inventory is the one damaged, consistent with Reference 2.1 5.5 Consistent with References 2.1 and 2.7, 30% of the Kr-85 found in the gap between the cladding and the fuel is released, along with 12% of the 1-131 and 10% of the remaining iodine, krypton, and xenon.
- 5. 6 The release of radionuclides fails to trip high-radiation alanns and escapes from containment, unfiltered, into the environment. There is a direct flow path through one of the clean waste receiver tanks as long as a containment isolation signal is not generated
- 5. 7 The release *is over a two hour period as per Reference 2.1.
6.0 ANALYSIS 6.1 Fuel Activity The first part of this analysis was to determine the activity of each radionuclide released to the reactor cavity water from the pellet-clad gap of the damaged assembly. First, the core inventory of each radionuclide per MW t one day after shutdown was found in Reference 2. 5. The value was divided by 204 (number of fuel assemblies in the core) to find the activity per MW t for the one damaged assembly. This was multiplied by the. 102 % rated power of 2580.6 MW t as well as the assembly peaking factor of 1.8 to find the activity in the peak assembly one day after shutdown. This value is then corrected for the extra day of decay using the radioactive decay equation. This value, unique to each radionuclide, is multiplied by the fraction of that nuclide in the pellet-clad gap that is released to yield the total nuclide release to the water from the damaged assembly. The equation for this can be written as:
where
- s. PF A.=F(
i r)e
.l g
204
-LN(2) 1440 tl/2 Ai
= activity released to water from pellet-clad gap, Ci Si
= Source term of individual isotope, Ci/MW t F g
= fraction of inventory in the pellet-clad gap inventory released P
= power of plant at 102 % *of rated power, MW t Fr
= peaking factor of peak assembly t 1,2
= half life of nuclide, in minutes
PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET 6.2 Activity Released Outside Containment E-A-NL-91-169-01 Sheet _7_ Rev # -~2:0....--_
The next step in this analysis was to find the activity that is released from the water and into the outside air. This was done using the overall decontamination factor for the water. For all iodine isotopes, D cff is 100, meaning that one hundredth, or 1 % of all iodine released from the pellet clad gap makes it to the outside air. For all other isotopes, D cff is set to 1, meaning that all of the activity released from the pellet clad gap makes it to the outside air. The denotation Q is used to represent the activity of each nuclide released to the outside air.
From there, the dose received due to each isotope was computed. This was done by multiplying the Q value for each isotope by the dose conversion factor (DCF cfd* Then it was multiplied by the Atmospheric Dispersion Factor. This number is based on the distance away from the location, so two values were used: one for the site boundary and one for the low population zone.
- For the iodine isotopes, the value produced was multiplied by the breathing rate, since the calculated dose from iodine is thyroid dose due to inhalation. This is represented by the following equations:
Hwb=Q DCF.X Q
for iodine isotopes and:
Hthy= (Q DCF.X) BR Q
for all other radionuclides where Hlhy
- Hwb x!Q DCF Q
BR
= dose to thyroid from inhalation of iodine
= dose to whole body from xenon and krypton exposure
= atmospheric dispersion factor for location
= dose conversion factor for isotope
= activity released outside containment
= breathing rate of an individual subject to radionuclide exposure The values of Hlhy*were then summed separately for the site boundary (sb) and the low population zone (lpz). The same was done for H wb' The values found as maximum doses are:
H lhy(sb)
H thy(lpz)
H w.,(sb)
H w.,(lpz)
= 41.19 rem
= 7.23 rem
= 0.12 rem
= 0.02 rem These values are well within the values given as limits by References 2.2 and 2.4.
7.0
SUMMARY
PALISADES NUCLEAR PLANT ANALYSIS CONTINUATION SHEET E-A-NL-91-169-01 Sheet _a_ Rev # -~2=---
This analysis was performed to demonstrate that the radiological consequences of a fuel handling accident are within the limits of References 2.2 and 2.4. The activity in the pellet-clad gap of the peak fuel assembly at the time of the accident was found. Then, the fraction of activity that is would be released is accounted for. The decontaminating ability of the water was then factored in to provide the activity released outside containment of each radionuclide involved. Finally, the dose related to this release was found at the site boundary as well as the low population zone, and the thyroid dose was corrected for the breathing rate of the person subject to the exposure. The exposures calculated for each isotope involved were them summed to find the overall exposures encountered.
The doses calculated at the site boundary were 41.19 rem thyroid and 0.12 rem whole body dose. The doses for the low population zone were calculated to be 7.23 rem thyroid and 0.02 rem whole body.
These are well inside the limits established and are considered acceptable.
PALISADES NUCLEAR.PLANT ANALYSIS CONTINUATION SHEET List of Attachments E-A-NL-91-169-01 Sheet _9_ Rev# -~2=---
8.1 Reference 2.14: Letter from H.G. Show (Siemens) to R.J. Gerling dated October 6, 1992.
Subject:
Fuel Internal Rod Pressure at End of Life.
- 8. 2 Technical Review Checklist 8.3 Engineering Analysis Checklist 8.4 Document Review Sheet
e Siemens Power Corporation Propri.
- SIEMENS October 6, 1992 HGS:327:92 Mr. R. J. Gerling Consumers Power Company Palisades Nuclear Power Plant 2nao Blue Star Memorial Hwy.
Covert, Ml 49043-9530
Dear Bud:
In response to information requested by CPCo, a RODEX2 gas pressure analysis for a fuel rod stored in the Palisades spent fuel storage pool has been performed.
Key input variables for the analysis are the FSAR design basis of 1 SOOF for the spent fuel storage pool and an LHGR = 0.05 kW/ft. ANSl/AN.S-5.1-1979 indicates that the ratio of the decay heat rate to the heat rate for infinite operation is 0.0028 two weeks following shutdown. Multiplying 0.0028 by the core average LHGR (5.23 kW/ft) gives 0.014 kW/ft; thus, the LHGR of 0.05 kW/ft is conservative. The hot operating end of life internal rod pressure was 2698 psia.
The analysis indicates that gas pressure in the fuel rod stored in the pool will be less than 1170 psia. For reference purposes, the SPC calculation number is E-5059-337-SX.
If you have any questions, please contact Mr. Jim Hulsman.
Very truly yours,
~
- H. G. Shaw Contract Administrator tlm
. c:
T. C. Bordine, CPCo Jackson
- l*llPPalisades
- - J. W. Hulsman, SPC S. F. Pierce, CPCo Palisades Siemens Power Corporation Nuclear Division
- Headquarters 155 108th Avenue NE. PO Box 90777 Bellevue. WA 98009-0777 Tel: (206) 453-4300 Fax: (206) 453-4446
TECllUCAL BQIEM CH.UI EA* 4-AIL-7/-161-tJI REY. 0 Proc No 9.11 Revision 5 Page 1 of 1 This checklist provides guidance for the review of engineering 1n1lyses.
Answer questions Yes or No. or N/A if they do not apply.
OocW11nt 111 comments an a 3110 Font. Satisfactory resolution of COllmlnts and completion of this chec:klt st ts noted by the Technically Reviewed signature on the Init11t1on and Review record black of Fona 3619.
- 1. Have the proper input codes, standards and design principles been spec:1f11d?
- 2.
Have the input codes, standards and design principles been properly applied?
- 3. Are all inputs and assU11Pttons valid and the basts for thet r use docWllntld?
- 4.
Is Y*ndor 1nforut1on ustd as input addressed co1TtCtl1 tn the analysts?
- s. If the analysis argumnt departs fro11 Vendor Inforutton/Rlc01m1ndat1ons, ts the departure Justtftcatton docUlllfttld7
- s. Are assumptions 1ccurat1l1 descrtbtcl lftcl reasonable?
- 7.
Has* the use of engtnHrtng Judg_,.t beeft doc.... tld lftcl Justtftld?
- 8. Are all constants, vartabl11 lftcl formalu corNCt and properly applttd!
- 9.
Have an1 *tnor (tnstptft,cant) eM"On bla tdeftttftlCIT If yes; Idattf7 oa the 3110 Fora ancl Justtt1 tbetr tnstgntftcanca.
l.
- 10. Does anal11t1 tnolve *ldtng? If Y11; vertfJ U..
followtnt tnforaatt* ts 1ccurat1l1...,,.... w oa the anilysts drawtftl (GutiMlt doc'lll1Rt).
- Type of V.lcl
- stza of Velt *
- Matle1al Betnt Jotnecl
- TMdmets of Matlrt1l Bltng Joined
- LOIKt* of V.ld(I)
- ApfNf111te Veld S111boloV
- 11. Has the obJicttve of the an1lysts bHlt M!
- 12.
H*ave adlltatstrattv* recpat,...ts suda 11......,.tnt ucl fon11t.been sattsftldt (Y, ~ H)A) y
~
v t%
i(
y I(
5ee t"Tt'Cochcl 3 f/t/ &~rf'-..
v I
Form 3698 9-89 PALISADES NUCLEAR PLA.
ENGINEERING ANALYSIS CH.E?Kusr Affected Revision lt~ms Affected By This EA Yes No Required Identify*
Closeout
_t.:..
Other EAs 0
JZf
- 2.
Design Documents Elec E-38 through E-49 0 ;z1
- 3.
Design Documents Mech M259, M664, M665 0
~
4.0 LICENSING DOCUMENTS 4.1 Final Safety Analysis Report (FSAR)
,¢ 0 Yes FSA£
\\4. \\ 4 FC-13'1 4.2 Technical Specifications 0
~
4.3 Standing Order 54 0
!ZI 5.0 PROCEDURES 5.1 Administrative Procedures 0
~
5.2 Working Procedures D
~
5.3 Tech Spec Surveillance Procedures D
~
6.0 OTHER DOCUMENTS 6.1 0-List D
~
6.2 Plant Drawings D
6.3 Equipment Data Base D ~
6.4 Spare Parts (Stock/MMS) 0 JZI 6.5 Fire Protection Program Report D ~
(FPPR) 6.6 Design Basis Documents D
J21 6.7 Operating Checklists D
~
6.8 SPCCJPIPP Oil and Hazardous Material Spilt Prevention Plan D ~
6.9 EEO Documents D 9f Do any of the following documents need to be generated as a result of this EA:
Yes No
- zf
- 1.
Corrective Action Document?
D Reference
- 2.
Safety Evaluation?
d 0
Reference
- 3.
EEO Evaluation Sheet?
0 0'
Reference Is PRC Review of this EA Required?
0 J2(
CompletedBY.y ?#~
Date 12/i1/~
)
- Identify Section, No, Drawing, Document, etc.
- PM'tf'S£111EPH Document Title Item Page and/or Number Section Number I
J.CC~Z5 Organ1zat1on
,,('¢ 5/11-formJllO 10-91 NUCLEAR OPERATIONS DEPARTMENT Document Review Sheet Date
/L.
Comments Document Number
.,L;,,-. --re -/.J3, -,.
Review Coordinator Date Re111s1on Number Page ;
of 2 Response or Resolution Uo"'c Date Jl 11 7Z.
Ted /ev; el(..* &./t ~A-.Nl.-.1/ -/I 1-C/ ?;t<' ~ pl' z L~i1 i:\\:
I*
Site Boundary Low Population Zone t=24 hrs t='=24 hrs (1/min) t=48 Thyroid Whole Bod Thyroid Whole Body J
Ci/MW Aa (Ci)
Lamb eta Aa (Ci)
Q (Ci)
(Rem)
(Rem)
(Rem)
(Rem)
Kr-83m 6.039E+OO 137.5 6.313E-03 0.015 0.001549 8.8E-13 1.5E-13 Kr-85m 1.489E+02 3390.5 2.579E-03 82.678 8.267843 0.000038 0.000006 Kr-85 2.999E+02 6828.7 1.230E-07 6827.514 2048.254 0.000150 0.000026 Kr-87 2.295E-02 0.5 9.084E-03 0.000 0.000000 2.4E-12 4.3E-13 Kr-88 4.452E+01 1013.7 4.068E-03 2.896 0.289638 0.000016 0.000002 Xe-131m 1.708E+02 3889.1 4.065E-05 3667.998 366.7997 0.000075 0.000013 Xe-133m 1.547E+03 35225.2 2.198E-04 25668.112 2566.811 0.002138 0.000375 xe...:.133 5.171 E+04 1177436.7 9.177E-05 1031682.524 103168.2 0.100088 0.017563 Xe-135m 6.693E+02 15240.0 4.513E-02 0.000 9.1 E-26 1.1 E-30 1.9E-31 Xe-135 7.388E+03 168224.8 1.268E-03 27095.860 2709.585 0.019638 0.003446 Xe-138 4.830E-27 0.0 4.906E-02 0.000 2.3E-57 7.0E-62 1.2E-62 1-131 2.696E+04 613879.2 5.987E-05 563172.157 675.8065 39.00168 6.844165 1-132 7.204E+02 16403.5 5.023E-03 11.848 0:011847 0.000004 0.000000 1-133 2.178E+04 495930.6 5.554E-04 222885.904 222.8859 2.173409 0.381398 1-134 3.046E-04 0.0 1.318E-02 0.000 4.0E-14 2.3E-18 4.0E-19 1-135 4.778E+03 108795.1 1.748E-03 8778.854 8.778854 0.014849 0.002605 41.18994 0.122146 7.228170 0.021434
consumers Power POWUUll&
MllUfEA#'S IWH5 Document Title
,?/A,-/P- //~"' r*.,~,/,i,/,-,?A~.t>/' /;,..,,/
Item Page and/or Number Section Number Lf~_,./ A.A.,d,../,0/'~I/
/
AL'~/ -<')#/-/~
- ~
.::::- ao.7~ l"~r i
/___,//,/
t/5P,y'
,Tj-;,
Re~~-',.,#
/,
- ..V/./f/
I Organization
/~5'#
Form 3110 10-91 I
NUCLEAR OPERATIONS DEPARTMENT Document Review Sheet J/,01,/ /,',.,,, 4c/de4'T I
Document Number 64-.4--..1/L_- 'f/'-/69-&/
/
Comments ~T L.-7:--~.J d i/YJ~t?,,,/ Z.L..e:-
/
- J//~
,_ /.
A,.,
,?J.o~f /LJ,23 k~r)
/
T/,:e:;
/~ /,? __ _,/A ;A<_T;;;;/,/
k /.. /,d" r/.,.
//.
/
dto_,,.e/,,,,, /ve/ /d -=>/',,.....,,~.""'/e..,.
/
/
/1/1'1
/c?::J~~ c;-,, A
/,.Pu,_,~ /ii0 ~-
/
- 1 Revision Number I j
Page/ of/
Response or Resolution 0
loat*?A-31Rf7i/f)Z~ I Date/i, I I Document Sponsor "I
IJ c, 3 I
Date
./
I I
{
consumers Power POWEIUllli
- MIUflfiJlll'S ~
Document Title r).f::' (; !,:,
/.
';/
/J).?~.:>
Item Page and/or Number Section Number A
f<~ /... LZ;../1.-.-
A I
//M
/.
Rev1~* -m"./ - I or9 a~i~a~ion
/_/A
.-_':.d_
~y
.. c"
.,:;i;1:%-.
.. v
- >.77'
-~ -
l Form 3110 10-91 NUCLEAR OPERATIONS DEPARTMENT Document Review Sheet
/)/.£.;,;?_/ d10'/:/t/.,;.
,:k,d Document Number
.4-./,
G/-,4.-,.;,.,/_ -'f'/.-//.7'-C'/
I Rev1s1on Number I Page
,/'
Comments Response or Resolution
~/},/:?/ //'!~&-
~
I Da~e _..
. I Review Coordinator 7/~A
,.-/_).. :._.S I
Date I
Document Sponsor
. I Date r
/O~ /