ML18053A165

From kanterella
Jump to navigation Jump to search
Attachment 1A - Braidwood Station Units 1 & 2 - Mark-up Emergency Plan EP-AA-1000 Pages
ML18053A165
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 01/31/2018
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation, Office of Nuclear Material Safety and Safeguards
Shared Package
ML18053A159 List:
References
RS-18-021
Download: ML18053A165 (64)


Text

ATTACHMENT 1A Emergency Plan Marked-up Pages - Braidwood Station Exelon Standardized Emergency Plan EP-AA-1000 and Emergency Plan Annex EP-AA-1001 Affected Pages

Exelon Standardized Emergency Plan EP-AA-1000 Affected Pages - Marked-up

EP-AA-1000 Revision 2930 EXELON NUCLEAR STANDARDIZED RADIOLOGICAL EMERGENCY PLAN September 2017 EP-AA-1000 (Revision 29)

PART II: Planning Standards And Criteria Exelon Nuclear Shift Technical Advisor (STA): During normal plant operations, the Senior Reactor Operators report to the Shift Manager and directly supervise the licensed Reactor Operators and all activities in the Control Room. During an abnormal condition, the Shift Manager assumes direct supervision of personnel and all activities in the Control Room while a qualified individual steps back and assumes an overview role as an STA with the specific responsibility of monitoring the maintenance of core cooling and containment integrity. An individual assigned the duty as the STA shall be available to the Control Room at all times.

Radiation Protection: The Station Radiation Protection personnel are responsible for the handling and monitoring of radioactive materials. Included in this organization are Health Physicists, Radiation Protection Supervisors and Technicians.

Chemistry: The Station Chemistry personnel are responsible for sampling of system effluents, and the chemical and radio-analytical analysis of those samples. Included in this organization are Chemists, Chemistry Supervisors and Technicians.

Security: The Station Security personnel are responsible for the physical security of the site. Included in this organization are Security Supervisors and Security Guards.

2. Authority Over the Emergency Response Organization The Emergency Director in Command and Control is the designated Exelon Nuclear individual who has overall authority and responsibility, management ability, and technical knowledge for coordinating all emergency response activities at the nuclear power station.
  • Control Room: Shift Emergency Director (Shift Manager)
  • TSC: Station Emergency Director
  • EOF: Corporate Emergency Director
3. Criteria for Assuming Command and Control (Succession)

Emergency personnel assume responsibility for their positions upon receiving notification to activate. The responsibility for initial assessment of and response to an emergency rests with the Shift Manager. The Shift Manager is the Shift Emergency Director and has the Station and Corporate Emergency Director's responsibilities and authority until relieved by a qualified Station Emergency Director.

The Station Corporate Emergency Director, once having relieved the Shift Manager of the Emergency Director responsibilities, is responsible for continued assessment of the severity of the emergency and for the necessary functions as described in the E-Plan, the Station Annex, and the emergency implementing procedures. Final succession is achieved when the Corporate Emergency Director assumes overall Command and Control, and directs Exelon Nuclear's Emergency Response activities.

December 2017 B-2 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear The Shift Emergency Director is relieved of Command and Control as soon as possible after the declaration of an Alert (or higher classification if Alert not declared). Command and Control may be transferred directly to the Corporate Emergency Director, or transferred to the Station Emergency Director on an interim basis. Following the Command and Control turnover, the Corporate Emergency Director shall have overall Command and Control of the Emergency Response.

Note that the Station Emergency Director takes responsibility for onsite Non-Delegable Responsibilities including Classification and Emergency Exposure Control. The Corporate Emergency Director takes responsibility for offsite Non-Delegable Responsibilities including Protective Action Recommendations and State/local Notifications. Command and Control does not transfer until the following criteria have been met:

  • Adequate staff levels are present in support of the non-delegable responsibilities.
  • The staff has been fully briefed as to the status of the event and the currently proposed plan of action.
  • A turnover between the Emergency Director relinquishing Command and Control and the Emergency Director assuming Command and Control has been made.

Although Exelon Nuclear's ERO fulfills all regulatory requirements for emergency response, it may be altered by the Emergency Director. This type of alteration will be based upon identified needs within the ERO, event dependent criteria, and identified needs of the company as a whole.

4. Non-Delegable Responsibilities Non-delegable responsibilities include the following functions:
  • Event classification.
  • Protective Action Recommendations (PARs) for the general public.
  • Notification of offsite authorities (approval of state/local and NRC notifications).
  • Authorization of emergency exposure controls in excess of 5 Rem TEDE and the issuance of potassium iodide (KI), for Exelon Nuclear emergency workers per EPA-400.

The Shift Manager is responsible for the initial classification of an event and assumes the position as Shift Emergency Director. In this capacity, the Shift Manager has responsibility for performing the non-delegable responsibilities until relieved.

The Shift Emergency Director is relieved of Command and Control as soon as possible after the declaration of an Alert (or higher classification if Alert not declared). Command and Control is transferred to the Station Emergency Director but may be transferred directly to the Corporate Emergency Director.

December 2017 B-3 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear When tThe Station Emergency Director assumes overall authority and responsibility for Classification and Emergency Exposure Controlperforming all the non-delegable duties from the Shift Manager,. Tthe Corporate Emergency Director (EOF) will subsequently relieve the Station Emergency Director (TSC) of overall Command and Control and assume the non-delegable responsibilities for PAR determination and notifications to offsite authorities.

Transition of Non-Delegable Responsibilities Control Room TSC EOF (Shift Emergency Director) (Station Emergency Director) (Corporate Emergency Director)

Classification Classification PARs PARs PARs PARs PARs Notifications Notifications Notifications Notifications Notifications Emergency Exposure Emergency Exposure Controls Controls December 2017 B-4 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

5. Emergency Response Organization Positional Responsibilities The Emergency Plan designates two types of augmented ERO responders. Those designated as Minimum Staff are those key ERO needed to relieve the on-shift staff of key EP functions/tasks required in response to the Emergency and are those required to activate their respective Emergency Response Facility (ERF).

Specifically, these are the ERO that are the absolute minimum needed to implement the emergency plan (i.e., if any position or function is not staffed then the emergency plan may not be effectively implemented). These positions in most cases are required to respond to their respective ERF within 60 minutes of the declaration of an Alert or higher. See Attachment 5, Table 5-1 for the list of On-shift and Minimum Staff positions.

The positions which are considered Full Augmented staff (i.e., non-min staff) are those positions which provide support for the minimum staff in their response to the Emergency. The Full Augmentation positions consist mostly of liaisons, coordinators and additional communicators which help facilitate communication and the emergency response effort over time, but are not directly needed to implement the functions/tasks identified in the Emergency Plan.

ERO staffing tables contained within the station specific Annexthis Emergency Plan, outlines ERO positions required to meet minimum staffing and full augmentation of the on-shift complement at an Alert or higher classification, and the major tasks assigned to each position. The full augmentation staffing levels are used as a planning basis to cover a wide range of possible eventsdescribed in Emergency Preparedness Implementing Procedures (EPIPs). For extended events (one which lasts for more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />), actual staffing will be established by the Emergency Director based on the event and personnel availability. However, additional staffing or reduced staffing will only occur after discussion concerning the impact on plant operations and emergency response.

In addition to maintaining adequate documentation of the event, responsibilities for each position are as follows:

a. Station Emergency Response Organization: The Station ERO is the onsite group that is activated during an emergency. It functions under the Station Emergency Director, who is responsible for organizing and coordinating the emergency efforts at and within the immediate vicinity of the station (including carrying out all onsite emergency efforts and the initial offsite environs monitoring efforts necessary to assess plant releases).

The Station ERO consists of station personnel who are involved with emergency response efforts necessary to control the plant during an incident. This organization operates out of the Control Room, the Technical Support Center (TSC) and the Operations Support Center (OSC). Collectively, members of the Station ERO provide for the following activities during an emergency:

  • Plant systems operations
  • Radiological survey and monitoring (including Environs Monitoring)

December 2017 B-5 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Firefighting
  • Rescue operations and First Aid
  • Decontamination
  • Security of plant and access control
  • Repair and damage control
  • Personnel protection including Assembly, Accountability and Evacuation
  • Communications
  • Initial Liaison responsibilities with Federal, state and local authorities When plant conditions warrant entry into the Severe Accident Management Guidelines (SAMGs), the Station Emergency Director or other qualified individual (e.g., Operations Manager) assumes the role of Decision-Maker. The Technical Manager and/or another Other qualified individual(s) assumes the role of Evaluator (at least 2 are required), and the Control Room staff assumes the role of Implementers. Control Room personnel will perform mitigating actions for severe accidents per EOPs prior to TSC activation.

All Station ERO personnel shall have the authority to perform assigned duties in a manner consistent with the objectives of this plan.

1) Shift Manager (Shift Emergency Director) Control Room A Shift Manager is on duty 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day and is the Shift Emergency Director in a declared emergency until relieved of this function. While serving in this capacity the Shift Manager is responsible for:
  • Activating the ERO (as deemed appropriate or as procedurally required).
  • Performing those duties outlined in Section B.5.a.2 for the Station Emergency Director. The responsibilities described for the Station Emergency Director applies to either the Shift Emergency Director or the Station Emergency Director depending on which individual is in Command and Control.

The on-duty Shift Manager directs the activities of the operating crew and is responsible for the safe operation of the plant in compliance with the station NRC operating license and the station operating procedures. The Shift Manager, after relinquishing Command and Control, functionally reports to the Operations Manager in the TSC.

The Shift Manager's responsibilities, when not in Command and Control, are described below:

December 2017 B-6 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • The authority and responsibility to shutdown the reactor when determined that the safety of the reactor is in jeopardy or when operating parameters exceed any of the reactor protection circuit set-points and automatic shutdown does not occur;
  • To ensure a review has been completed to determine the circumstance, cause, and limits under which operations can safely proceed before the reactor is returned to power following a trip or an unscheduled or unexplained power reduction;
  • The responsibility to be present at the plant and to provide direction for returning the reactor to power following a trip or an unscheduled or unexplained power reduction;
  • The responsibility to adhere to the station Technical Specifications and to review routine operating data to assure safe operation;
  • The responsibility to identify applicable EALs and emergency classifications; and
  • The responsibility to adhere to plant operating procedures and the requirements for their use. During an emergency, operations personnel may depart from approved procedures where necessary to prevent injury to personnel, including the public, or damage to the facility consistent with the requirements of 10 CFR 50.54(x) and (y).
  • Supervise the activities of the Control Room Crew, Operations Communicator and Damage Control Communicator in the Control Room.
2) Station Emergency Director TSC The Station Emergency Director reports to the Corporate Emergency Director and supervises and directs the Station ERO. The Station Emergency Directors responsibilities include organizing and coordinating the onsite emergency efforts. Additionally, the Station Emergency Director has the requisite authority, plant operating experience and qualifications to implement in-plant recovery operations.

a) Station Emergency Director Responsibilities while in Command and Control:

  • Perform all non-delegable responsibilities as the Emergency Director in Command and Control until relieved by the EOF.
  • Conduct personnel assembly/accountability and evacuation of non-essential personnel at Site Area Emergency, General Emergency or as conditions warrant.

December 2017 B-7 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • If the emergency involves a hazardous substance and/or oil discharges, ensure that appropriate notifications and responses have been made.
  • Determine if the OSC is to remain activated at the Alert Classification.

b) Station Emergency Director Responsibilities while not in Command and Control:

  • Event classification.
  • Emergency exposure controls.
  • Protective actions for all onsite personnel.
  • Supervision of the Station ERO.
  • Inform the Corporate Emergency Director and onsite NRC as to the status of the plant.
  • Assist the Corporate Emergency Director in the acquisition of information for the state/local notifications, NRC notifications and offsite agency updates.
  • Provide information and recommendations to the Corporate Emergency Director.
  • Implement plans, procedures and schedules to meet emergency response objectives as directed by the Corporate Emergency Director.
  • Request from the Corporate ERO any additional material, personnel resources or equipment needed to implement response plans and operations.
  • Assume the duties and responsibilities of Decision-Maker when a transition to Severe Accident Management Guidelines (SAMGs) is initiated. This responsibility can be delegated to the Operations Manager if qualified.
3) TSC Director TSC The TSC Director reports to the Station Emergency Director and is responsible for the content of information transmitted from the TSC to other agencies (or facilities) and for documenting information received at the TSC in coordination with the Station Emergency Director. Responsibilities include:
  • Verify that qualified individuals are filling Communicator positions in the Control Room, TSC and OSC.

December 2017 B-8 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Supervise the activities of the Logistics Coordinator and state/local Communicator.
  • Ensure that communications are established with appropriate parties as directed by the Station Emergency Director.
  • Ensure that all required notifications to offsite governmental agencies (state/local and NRC) are timely and accurate.
  • Act as the Exelon Nuclear Liaison to any NRC Site Team Representatives.
  • Ensure that the NRC Site Team Representatives are directed to their appropriate counterparts.
  • Assist the Corporate Emergency Director in the acquisition of information for off-site agency updates.
  • Record and relay inquiries to the Station Emergency Director. In addition, record responses to such inquiries prior to transmission.
  • Assist the Station Emergency Director in maintaining proper records.
4) ENS Communicators CR/TSC/OSC The Communicators are responsible for transmitting/receiving information to and from the TSC, OSC and Control Room. General rResponsibilities assigned to the ENS all Communicators include:
  • Establish communications with appropriate parties as directed.
  • Transmit information that has been reviewed and/or approved by the responsible Manager or Coordinator.
  • Document time, date and information being transmitted or received on appropriate forms.
  • Record and relay inquiries and the responses to those inquiries.
  • Assist appropriate Managers and Coordinators in maintaining proper records and logs of emergency related activities.
  • Gather, record and post appropriate information.

a) Specific responsibilities assigned to the State/Local Communicator include:

December 2017 B-9 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Monitor NARS communications until released by the TSC Director.

b) Specific responsibilities assigned to the Damage Control Communicator include:

  • Relay requests from the Control Room and TSC for the dispatching of OSC Teams.
  • Apprise the station emergency response facilities of the status of OSC Team activities.

c) Specific responsibilities assigned to the Operations Communicator include:

  • Apprise the TSC and EOF staff of the overall plant condition and significant changes to system and equipment status.
  • Inform the Control Room, TSC, and EOF of significant changes in event status (e.g. changes in classification, command and control, initiation of station assembly, accountability, evacuation, etc.).

d) Specific responsibilities assigned to the TSC Technical Communicator include:

  • Establish and maintain contact with the EOF Technical Advisor.
  • Provide EOF with updates on technical support activities and priorities.

e) Specific responsibilities assigned to the ENS Communicator include:

  • Notify the NRC of changes in event classification, prior to the EOF accepting Command and Control, and assist the EOF ENS Communicator in completing the NRC Event Notification Worksheet and responding to NRC inquiries.
  • Provide real time updates of significant changes to plant and system status and responses to NRC inquiries.
  • Maintain continuous communications with the NRC, if requested, via the NRC ENS phone or commercial telephone line.

December 2017 B-10 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear f) Specific responsibilities assigned to the HPN Communicator include:

  • Maintain continuous communications with the NRC, if requested, via the NRC Health Physics Network (HPN) phone or commercial telephone line.
  • Communicate current Health Physics information to NRC representatives, as requested.
  • Coordinate the communications of radiological information to the NRC with the EOF HPN Communicator (onsite vs. environmental data).
5) Operations Manager TSC The Operations Manager reports to the Station Emergency Director. Major functions include determining the extent of station emergencies, initiating corrective actions, and implementing protective actions for onsite personnel.

In the event that the Station Emergency Director becomes incapacitated and can no longer fulfill the designated responsibilities, the Operations Manager will normally assume the responsibilities until relieved by another qualified Station Emergency Director. Responsibilities include:

  • Coordinate TSC efforts in determining the nature and extent of emergencies pertaining to equipment and plant facilities in support of Control Room actions.
  • Recommend equipment operations checks and miscellaneous actions to the Control Room in support of restoration and accident mitigation.
  • Approve emergency special procedures, and implement as required under the provisions of 10 CFR 50.54(x).
  • Assist the Maintenance Manager in determining the priority assigned to OSC activities.
  • Organize and direct medical response efforts for injured personnel.
  • Ensure adequate staffing of the Control Room and TSC subordinates.
  • Ensure the Shift Manager is informed of OSC staffing utilization and activities.
  • Identify steps or procedures that the Operations staff should be utilizing to properly respond to the emergency condition.

December 2017 B-11 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Assist the Station Emergency Director in evaluating changes in event classification.
  • Supervise the activities of the Operations Communicator and the ENS Communicator in the TSC.
  • Act as the TSC liaison with the appropriate NRC Site Team Representative.
  • At the direction of the Station Emergency Director, assume the duties and responsibilities of the Evaluator, or Decision-Maker if qualified, when transition to Severe Accident Management Guidelines (SAMG) is initiated.
6) Technical Manager TSC The Technical Manager reports to the Station Emergency Director and directs a staff in performing technical assessments of station emergencies and assists in recovery planning. Responsibilities include:
  • Accumulate, tabulate and evaluate data on plant conditions.
  • Evaluate plant parameters during an emergency to determine the overall plant condition.
  • Coordinate core damage assessment activities.
  • Identify data points and control parameters that the Operations staff should monitor.
  • Ensure that current and adequate technical information is depicted on status boards.
  • Identify and direct staff in the development of special procedures needed to effect long-term safe shutdown or to mitigate a release.
  • Supervise the total onsite technical staff effort.
  • Act as the TSC liaison with state and appropriate NRC Site Team representatives.
  • Assist the Radiation Protection Manager for onsite radiological/technical matters.
  • Assist the Station Emergency Director in evaluating plant based PARs (prior to Corporate Emergency Director accepting command and control) and changes in event classification.
  • Supervise the activities of the TSC Technical Communicator.

December 2017 B-12 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

7) Technical Support Staff TSC The TSC Technical Support Staff consists of the following minimum staff engineering positions:

Electrical Engineer Mechanical Engineer Core/Thermal Hydraulic Engineer - serves as Core Damage Assessment Methodology (CDAM) Evaluator, as applicable.

In addition, station Engineering support will be augmented on an as needed basis to support accident assessment and mitigation activities.

8) Logistics Coordinator TSC The Logistics Coordinator reports to the TSC Director and provides administrative services in support of emergency/recovery operations.

Responsibilities include:

  • Coordinate shift relief and continual staffing of the station.
  • Arrange for clerical staff at the TSC, OSC and Control Room.
  • Assist the Security Coordinator in coordinating ERO and station activities in support of on-going security contingency, accountability or site/area evacuation efforts.
  • Support the processing of special procedures and interim reports during an emergency.
  • Ensure that event status and priority logs are being maintained in the TSC.
  • Coordinate record-keeping efforts at the station.
  • Arrange for food, sleeping facilities and other necessary accommodations for onsite emergency workers.
  • Arrange for specialized training of Emergency Response personnel as needed.

December 2017 B-13 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

9) Radiation Protection Manager (RPM) TSC The Radiation Protection Manager reports to the Station Emergency Director and supervises the activities of the Radiation Controls Coordinator and Radiation Controls Engineer. The TSC RPM directs a staff in determining the extent and nature of radiological or hazardous material problems onsite.

Responsibilities include:

  • Accumulate, tabulate and evaluate data on plant conditions such as meteorological and radiological monitoring readings, and other pertinent data.
  • Act as the TSC liaison with the appropriate NRC Site Team representative.
  • Ensure use of protective clothing, respiratory protection, and access control within the plant as deemed appropriate to control personnel exposures.
  • Ensure that appropriate bioassay procedures have been implemented for onsite personnel when a radioactivity incident has occurred.
  • Ensure that personnel are decontaminated, if necessary.
  • Authorize personnel exposures below 5 Rem TEDE (EPA-400 lower limit).
  • Assist the Station Emergency Director in determining if exposures in excess of the 5 Rem TEDE (EPA-400 lower limit) are necessary.
  • Advise the Station Emergency Director of situations when the use of KI should be considered.
  • Assist the Station Emergency Director in evaluating dose-based PARs (prior to Corporate Emergency Director accepting command and control) and changes in radiological event classification.
  • Advise the Station Emergency Director and EOF Radiation Protection Manager of changes in radiological release status.
  • Assist the Operations Manager in planning rescue operations and provide monitoring services as required, including the transfer of injured and/or contaminated personnel.
  • Coordinate with the Security Coordinator to determine the routes to be used for evacuation of non-essential personnel.
  • Assure additional radiation protection personnel and/or equipment is arranged for, as necessary.

December 2017 B-14 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

10) Radiation Controls Engineer (RCE) TSC The Radiation Controls Engineer reports to the Radiation Protection Manager and coordinates the radiological and chemistry interface between the technical support engineering efforts. Responsibilities include:
  • Monitor area and process radiation monitors to identify trends and potential hazards within the station.
  • Evaluate plant environmental factors regarding radiological and other hazardous material conditions.
  • Evaluate radiological and hazardous material surveys and chemistry sample results as appropriate.
  • Direct the performance of sampling activities through coordination with the OSC Chemistry Lead in support of operations and core damage estimates as necessary.
  • Coordinate radiological and chemistry information with the Core/Thermal Hydraulic Engineer in support of core damage assessment.
11) Radiation Controls Coordinator (RCC) TSC The Radiation Controls Coordinator reports to the Radiation Protection Manager. The RCC coordinates site and in-plant Radiation Protection response activities through the OSC Radiation Protection Lead.

Responsibilities include:

  • Support the OSC Radiation Protection Lead in the dispatching of OSC Teams.
  • Assist the Operations Manager in planning radiological controls for personnel dispatched from the Control Room.
  • Ensure the proper use of protective clothing, respiratory protection, and access controls in the plant as appropriate to control personnel exposure.
  • Monitor habitability concerns impacting access to plant and site areas.
  • In coordination with the OSC Radiation Protection Lead, assemble and dispatch the Field Monitoring Teams as required.
  • Supervise the activities of the HPN Communicator in the TSC.
  • Request additional Radiation Protection personnel and/or equipment, as necessary in support of station activities and staff relief.

December 2017 B-15 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Prior to EOF Protective Measures Group staffing:

Perform dose assessments and provide appropriate dose-based PARs.

Coordinate Field Monitoring Team activities.

Monitor meteorological conditions and remain cognizant of forecast data.

  • Following EOF Protective Measures Group staffing:

Transfer control of the Field Monitoring Teams to the EOF Environmental Coordinator when appropriate.

Transfer responsibility of dose assessment activities to the EOF Dose Assessment Coordinator.

Assist the EOF Environmental Coordinator in the acquisition of information for the off-site agency updates.

12) Maintenance Manager TSC The Maintenance Manager reports to the Station Emergency Director and directs a staff in providing labor, tools, protective equipment and parts needed for emergency repair, damage control and recovery efforts to place the plant in a safe condition or return the plant to its pre-accident status.

Responsibilities include:

  • Direct the total onsite maintenance and equipment restoration effort.
  • Request additional equipment in order to expedite recovery and restoration.
  • Supervise the activities of the OSC Director and the TSC Damage Control Communicator.
  • Ensure the Operations Manager is informed of OSC staffing utilization and activities.
  • In coordination with the Operations Manager, determine the priority assigned to OSC activities.
  • Ensure adequate staffing of the OSC.
  • Assist in rescue operations.
  • Identify required procedures that need to be written or implemented in support of the response efforts.

December 2017 B-16 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

13) Security Coordinator TSC The Security Coordinator reports to the Station Emergency Director and maintains plant security and personnel accountability at the nuclear station.

Responsibilities include:

  • Maintain plant security and account for all personnel within the protected area.
  • Assist the Station Emergency Director in evaluating changes in security related threats and event classifications.
  • Identify any non-routine security procedures and/or contingencies that are in effect or that require a response.
  • Expedite ingress and egress of emergency response personnel.
  • Coordinate with the Radiation Protection Manager in controlling ingress and egress to and from the Protected Area if radiological concerns are present.
  • Provide for access control to the Control Room, TSC and OSC, as appropriate.
  • Expedite entry into the Protected Area, as necessary, for the NRC Site Team.
  • Act as the TSC liaison with the appropriate NRC Site Team representative.
  • Assist the Radiation Protection Manager in determining personnel evacuation routes as necessary.
  • Coordinate the evacuation of station non-essential personnel with the appropriate Local Law Enforcement Agencies (LLEAs).
14) Operations Support Center Director OSC The OSC Director reports to the Maintenance ManagerEmergency Director and supervises the activities of OSC personnel. Responsibilities include:
  • Assign tasks to designated Leads as available:

--Operations I&C Maintenance Mechanical Maintenance L Electrical Maintenance R adiation Protection December 2017 B-17 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Chemistry

  • Coordinate with the OSC Operations Lead in the dispatch of Operations personnel to support Control Room and OSC Team activities.
  • Notify the Control Room and TSC prior to dispatch of any OSC teams into the plant.
  • Maintain OSC resources including personnel, material, and equipment.
  • Maintain accountability for all individuals dispatched from the OSC.
  • Conduct periodic briefings on the overall plant status, emergency response activities, and station priorities.
  • Assemble and dispatch the Field Monitoring Teams as required.
15) Assistant Operations Support Center Director OSC The Assistant OSC Director reports to the OSC Director and supports the OSC Director in supervising the activities of personnel reporting to the OSC.

The Assistant OSC Director may be filled by an OSC Lead, normally the Radiation Protection Lead. Responsibilities include:

  • Assist the OSC Director in supervising personnel assigned to the OSC.
  • Assist in formation of Field Monitoring Teams as directed by the TSC.
  • Assist in formation of sampling teams.
  • Ensure that records of in-plant survey information and radiochemistry results are maintained.
  • Ensure that accumulated exposure records for all essential onsite personnel are maintained.
  • Coordinate with the OSC Leads to organize in-plant teams to support station priorities.
  • Ensure that in-plant team dispatch briefings include expected activities and radiological hazards.
  • Ensure that periodic facility briefings are conducted on plant radiological conditions.
16) OSC Leads OSC OSC Leads report to the OSC Director and are assigned from the following station departments:

December 2017 B-18 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Mechanical Maintenance
  • Electrical /Maintenance
  • Instrument and Control
  • Radiation Protection
  • Chemistry
  • Operations (on-shift Supervising Operator or designated Operations representative)

The OSC Lead assigned to an OSC team is responsible at all times for the safety of team personnel and to keep the OSC Director apprised of team status. Specifically, the OSC Leads are responsible for the managing and supervising OSC team personnel, including:

  • Conduct of adequate pre-dispatch briefings.
  • Ensuring adequate protective equipment and measures have been identified.
  • Tracking of OSC team activities while dispatched.
  • Debriefing of team personnel upon return to the OSC.
b. Corporate Emergency Response Organization
1) Nuclear Duty Officer (NDO)

The NDO is the Exelon Nuclear individual who acts as the initial Corporate contact for declared events. Responsibilities include:

a) Actions for all classified events:

  • Contact the affected station to verify and obtain updated information concerning emergency response actions and event status.
  • Notify Exelon Nuclear Executives of event.
  • Provide information on the event to State Duty Officers, if requested.
  • Notify the on-call Exelon Communications and Public Affairs Representative.
  • Prior to EOF activation, review any news releases for accuracy.

December 2017 B-19 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear b) Actions for Alert classifications and above:

  • Complete all actions as listed above.
  • Notify American Nuclear Insurers (ANI) prior to being transferred to the EOF.
2) Corporate Emergency Director EOF a) When the Station Emergency Director has Command and Control, the ongoing responsibilities include:
  • Coordinate all Exelon Nuclear activities involved with the emergency response.
  • Ensure off-site agency updates are periodically communicated as required/requested.
  • Coordinate Exelon Nuclear press releases with the Nuclear Duty Officer and Exelon Communications and Public Affairs.
  • Request assistance from non-Exelon Nuclear emergency response organizations, as necessary.

b) Following assumption of Command and Control, the additional responsibilities assigned to the Corporate Emergency Director include:

  • Assumes overall Command and Control of emergency response activities and the non-delegable responsibilities for PAR determination and the notification of offsite authorities.
  • Ensure that Federal, state and local authorities and industry support agencies remain cognizant of the status of the emergency situation. If requested, dispatch informed individuals to offsite governmental Emergency Operation Centers (EOCs).
  • Approve the technical content of Exelon Nuclear press releases prior to their being released to the media.

December 2017 B-20 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

3) EOF Director EOF The EOF Director reports to the Corporate Emergency Director and has the authority, management ability and technical knowledge to assist the Corporate Emergency Director in the management of Exelon Nuclear's offsite ERO.

In the event that the Corporate Emergency Director becomes incapacitated, the EOF Director shall assume the responsibilities of the Corporate Emergency Director until a transfer of Command and Control can be affected either back to the station or to another qualified Corporate Emergency Director. Responsibilities include:

  • Direct and coordinate the activation and response efforts of the EOF staff in support of the Corporate Emergency Director.
  • Evaluate the need to augment the EOF staff based on events in progress.
  • Assess the effectiveness of ongoing EOF working relationships.
  • Monitor information flow within the EOF to ensure that facility activities remain coordinated.
  • Prepare state/local notification forms with the assistance of the EOF Radiation Protection Manager and the Technical Support Manager.
  • Coordinate services as necessary to support EOF operations.
  • Coordinate with the Administrative Coordinator for continual shift staffing requirements.
  • Assist in the conduct of Corporate Emergency Director duties.
  • Act as the designated alternate for approval of the technical content of Exelon Nuclear Press Releases and information released to the News Media.
  • Act as purchasing agent in support of the TSC for contract negotiation/administration.
4) Technical Support Manager EOF The Technical Support Manager reports to the EOF Director and directs the activities of the Technical Support Group. Responsibilities include:
  • Assist the Corporate Emergency Director in monitoring changes in event classification.
  • Assist the Corporate Emergency Director in determining plant-based PARs when necessary.

December 2017 B-21 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Provide information to the EOF Director for completing the state/local notification form.
  • Provide the Corporate Emergency Director information concerning the status of plant operations, and recommendations for mitigating the consequences of the accident.
  • Coordinate the overall Exelon Nuclear engineering support from corporate staff and unaffected stations.
  • Interface with Industry and contractor engineering support organizations.
  • Ensure that the EOF Radiation Protection Manager is informed of changes in plant status that impacts or potentially impacts the offsite environment or PARs.
  • Provide technical information on facility and system design.
  • Assist in the development of post-accident recovery measures.
5) Operations Advisor EOF The Operations Advisor reports to the Technical Support Manager, directs the ENS Communicator, and is responsible for obtaining and analyzing plant status information and ensuring that it is disseminated. Specific responsibilities include:
  • Monitor the Operations Status Line to keep apprised of:

Control Room activities including progress on Emergency Operating Procedures.

Significant changes in plant system/equipment status and critical parameters.

Possible changes in event classification.

  • Identify and track critical parameters for the identification and trending of current plant status information.
  • Assist the station in identifying Operations resources from corporate staff or unaffected stations for direct support of plant shift operations personnel.
  • Assist the ENS Communicator in the completion of the NRC Event Notification Worksheet and in responding to NRC inquiries.
  • Ensure that the EOF Radiation Protection Manager is informed of changes in plant status that impact or potentially impact the offsite environment or PARs.

December 2017 B-22 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

6) ENS Communicator EOF The ENS Communicator reports to the Operations Advisor. Specific responsibilities include:
  • Notify the NRC of changes in event classification. Generally, the TSC ENS Communicator focuses on real time plant operations and the EOF ENS Communicator focuses on notifications following changes in event classification and overall changes in event response or status.
  • Establish and maintain continuous communications with the NRC, if requested, via the NRC ENS phone or commercial telephone line.
  • Coordinate NRC communications with the ENS Communicator in the TSC.
7) Technical Advisor EOF The Technical Advisor reports to the Technical Support Manager and is responsible for obtaining and analyzing technical support information, accident mitigating activities and priorities and ensuring that it is disseminated. Responsibilities include:
  • Monitor the Technical Conference Line to remain aware of TSC technical support activities, strategies and priorities.
  • Assist the Dose Assessment Coordinator in acquiring technical information pertaining to release pathway and core damage assessment.
  • Supervise the activities of the Events Recorder.
8) Events Recorder EOF The Events Recorder reports to the Technical Advisor. Responsibilities include:
  • Gather/record approved information on status boards as requested.
  • Maintain an event chronology/status log.
9) Radiation Protection Manager EOF The Radiation Protection Manager reports to the EOF Director and directs the activities of the EOF Radiation Protection staff. Specific responsibilities include:
  • Recommend changes in event classification and PARs based upon effluent releases or dose projections.
  • Assist the EOF Emergency Director in the evaluation of the significance of an emergency with respect to the public.

December 2017 B-23 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Notify the EOF Emergency Director of meteorological changes that may impact identification of downwind areas.
  • Advise the Corporate Emergency Director of protective actions taken by the station for plant personnel.
  • Assist the TSC in the planning and coordination of activities associated with the evacuation of non-essential personnel.
  • Advise the Corporate Emergency Director on the need for emergency exposures or for issuance of KI to the Field Monitoring Teams or Exelon personnel required to enter the plume.
  • Determine the need for and contact Occupational Health/Industrial Safety Services personnel for assistance.
  • Monitor plant radiological conditions and advise the TSC Radiation Protection Manager of any adverse trends or potential release pathways that may impact existing event classification.
  • Assist in the completion and review of the state/local notification form.
  • Maintain cognizance of environmental sampling activities.
  • Ensure state authorities are provided information pertaining to Exelon Field Monitoring Team activities and sample results.
  • Assist the affected station in the following areas:

Planning and coordination of activities associated with the evacuation of non-essential personnel.

Acquisition of additional instrumentation, dosimetry, protective equipment and radiological support personnel.

  • Assist and interface with the EOF Technical Support Group and the station in the development of plans for plant surveys, sampling, shielding, and special tools in support of waste systems processing and design modification activities.
  • Upon request, provide in-plant health physics data to Emergency Public Information personnel and the HPN Communicator.
  • Coordinate Field Monitoring Team activities.
  • Determine needs of the Dose Assessment Coordinator and the ENS Communicator for updates on Field Monitoring Team data and ensure distribution of new data to them in accordance with those needs.

December 2017 B-24 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Promptly report new environmental or Field Monitoring Team exposure data to the Dose Assessment Coordinator.
10) Environmental Coordinator EOF The Environmental Coordinator reports to the EOF Radiation Protection Manager and directs the Field Team Communicator, Field Monitoring Teams and the State Environs Communicator. Responsibilities include:
  • Coordinate the transfer of control of the Field Monitoring Teams if initially under the direction of the TSC Radiological Controls Coordinator.
  • Ensure communications are established with the TSC to obtain information on the accident conditions, meteorological conditions and estimates of radioactive material releases.
  • Maintain cognizance of Field Monitoring Team exposure. When warranted, ask the Dose Assessment Coordinator to initiate an evaluation of the need for administering KI to Exelon nuclear workers.
  • Determine needs of the Dose Assessment Coordinator, the Dose Assessor, the HPN Communicator and the State Environs Communicator(s) for updates on Field Monitoring Team data and ensure distribution of new data to them in accordance with those needs.
  • Upon request, provide environmental data to Emergency Public Information personnel.
  • Evaluate and coordinate additional equipment and personnel as necessary from unaffected stations to augment and/or relieve station Field Monitoring Teams.
11) State Environs Communicator EOF The State Environs Communicator is staffed as requested by the applicable state agencies. The State Environs Communicator reports to the Environmental Coordinator. Responsibilities include:
  • As needed, obtain release and dose assessment data from the Dose Assessment Coordinator and Field Monitoring Team data from the Environmental Coordinator.
  • Coordinate activities and information flow between the EOF Protective Measures Group and the affected state(s) environmental authorities, including periodic updates on meteorological conditions, Field Monitoring Team activities and survey/sample results.
  • Ensure that the Environmental Coordinator is aware of state environmental activities and sample results.

December 2017 B-25 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

12) Field Team Communicator EOF The Field Team Communicator reports to the Environmental Coordinator.

Responsibilities include:

  • Establish and maintain contact with the dispatched Field Monitoring Teams.
  • Document the Environmental Coordinators instructions and then relay this information to the Field Monitoring Teams.
  • Document environmental data reported by the Field Monitoring Teams.
  • Periodically obtain and document information on Field Monitoring Team radiological exposure.
  • Promptly report new environmental or Field Monitoring Team exposure data to the Environmental Coordinator.
  • Document questions and answers directed to and received from the Field Monitoring Teams. Ensure the Environmental Coordinator is cognizant of these information requests and relay replies to these requests.
13) Dose Assessment Coordinator EOF The Dose Assessment Coordinator reports to the EOF Radiation Protection Manager and directs the activities of the Dose Assessor and the HPN Communicator. Responsibilities include:
  • Interpret radiological data and provide PARs based upon dose projections to the EOF Radiation Protection Manager.
  • Advise the EOF Radiation Protection Manager of changes in event classification based on effluent releases or dose projections.
  • Initiate evaluation of the need for administering KI to Exelon nuclear workers when requested by the Environmental Coordinator.
  • Remain cognizant of forecast and meteorological data and ensure the status is updated periodically.
  • Notify the EOF Radiation Protection Manager of meteorological changes that may impact identification of downwind areas.
  • Upon request, provide release and dose assessment data to Emergency Public Information personnel, the HPN Communicator, and the State Environs Communicators.

December 2017 B-26 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

14) Dose Assessor EOF The Dose Assessor reports to the Dose Assessment Coordinator.

Responsibilities include:

  • Perform dose projections using the Dose Assessment computer models as directed by the Dose Assessment Coordinator.
  • Monitor meteorological and plant effluent conditions.
  • Notify the Dose Assessment Coordinator of meteorological changes that may impact identification of downwind areas.
  • Evaluate the need for administering KI to Exelon nuclear workers when requested by the Dose Assessment Coordinator.
15) HPN Communicator EOF The HPN Communicator reports to the Environmental Coordinator.

Responsibilities include:

  • Provide updates and respond to inquiries from the NRC on offsite environmental data, release status, dose projections and changes to PARs for the general public.
  • Obtain release and dose assessment data from the Dose Assessment Coordinator and Field Monitoring Team data from the Environmental Coordinator.
  • Maintain continuous communications with the NRC, if requested, via the NRC HPN phone or commercial telephone line.
  • Communicate current Health Physics information to NRC representatives, as requested.
16) Logistics Manager EOF The Logistics Manager reports to the EOF Director and directs the activities of the administrative, security and liaison personnel. Responsibilities include:
  • Ensure contact is made and communications are maintained with appropriate Non-Exelon Nuclear personnel whose assistance may be required to terminate the emergency conditions and to expedite the recovery.
  • Advise the EOF Director concerning the status of activities relating to governmental interfaces.
  • Obtain support from Human Resources, the Comptrollers Office, the Legal Department, Accounting Department and others as required.

December 2017 B-27 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Coordinate with the Nuclear Duty Officer to maintain communications with ANI and INPO.
  • Ensure that access to the EOF is limited to Emergency Responders and authorize admittance to non-Exelon personnel.
  • Ensure that NRC Site Team Representatives are directed to the Regulatory Liaison upon arrival at the EOF.
  • Ensure that updates and information are provided to the EOC Liaisons and to offsite officials present in the EOF.
  • Assist in obtaining and coordinating additional equipment/materials and

/or technical expertise to support station requests, including Exelon Corporate staff, unaffected stations and vendor/contractors.

  • Coordinate maintenance of EOF equipment as necessary.
  • Ensure shift relief and continual staffing for the EOF.
17) Administrative Coordinator EOF The Administrative Coordinator reports to the Logistics Manager.

Responsibilities include:

  • Direct the activities of the Computer Specialist.
  • Direct the clerical staff and ensure the clerical requirements for the other EOF and JIC staff are met.
  • Obtain clerical support for the EOF and JIC.
  • Coordinate shift relief and continual staffing for the EOF.
  • Obtain services as appropriate to support operation of the EOF.
18) Computer Specialist EOF The Computer Specialist reports to the Administrative Coordinator.

Responsibilities include:

  • Assist any personnel in logging in, initializing or using a desired computer program.
  • Investigate and repair problems encountered with communications equipment and computer equipment/applications.

December 2017 B-28 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

19) Security Coordinator EOF The Security Coordinator reports to the Logistics Manager. Responsibilities include:
  • Provide and interpret information on security events.
  • Assist with access control activities at the EOF and JIC.
  • Perform the following in support of the TSC Security Coordinator:

Provide assistance in resolving security events.

Assist as a liaison for local, state and federal law enforcement agencies during security related events.

Serve as the primary contact to the security force for additional support, if necessary, during a security event.

  • Obtain additional resources to support access control measures needed at the EOF and JIC.
20) State/Local Communicator EOF The State/Local Communicator reports to the Logistics ManagerEmergency Director. Responsibilities include:
  • Prepare state/local notification forms with the assistance of the Corporate Emergency Director.
  • Ensure that the Logistics Manager is made aware of issues and questions raised by offsite agencies and then relay the replies to these requests.
21) EOC Communicator EOF The EOC Communicator reports to the Logistics Manager. Responsibilities include:
  • Coordinate and dispatch EOC Liaisons as needed or requested.
  • Establish and maintain periodic contact with each location where Exelon Nuclear EOC Liaisons have been dispatched.
  • Ensure EOC Liaisons are provided event information and notifications.
  • Ensure that the Logistics Manager is made aware of issues and questions raised by offsite agencies and then relay the replies to these requests.

December 2017 B-29 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

22) County EOC Liaison(s) County EOCs The County EOC Liaison(s) will be dispatched to County Emergency Operations Centers (EOCs) based on established agreements with the counties. The County EOC Liaisons use the EOC Communicator as their contact at the EOF. Responsibilities include:
  • Monitor and report County EOC activities to the EOF.
  • Conduct briefings and answer questions.
  • Provide simplified explanations to EOC personnel of technical details distributed through approved channels.
  • Assist with confirmation/verification of information distributed through approved channels.
  • Provide media at the EOC with approved Exelon Nuclear press releases.
  • Assist Emergency Public Information personnel in rumor control and media monitoring.
23) State EOC Liaison(s) State EOCs At the request of state officials and/or at the discretion of the Corporate Emergency Director, Exelon Nuclear will provide Liaison personnel to state Emergency Operation Centers (EOCs). The state EOC Liaisons use the EOC Communicator as their contact at the EOF. Responsibilities include:
  • Monitor and report state EOC activities to the EOF.
  • Conduct briefings and answer questions as requested.
  • Assist Emergency Public Information personnel in rumor control and media monitoring.
24) Regulatory Liaison EOF The Regulatory Liaison reports to the Logistics Manager. Responsibilities include:
  • Coordinate interfaces between Exelon Nuclear personnel and governmental agencies within the EOF.
  • Obtain necessary equipment and supplies to support activities of governmental agencies located in the EOF.
  • Act as the Exelon Nuclear Liaison to the NRC Site Team representatives.

December 2017 B-30 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

c. Public Information Emergency Response Organization
1) Corporate Spokesperson JIC The Corporate Spokesperson reports to the Corporate Emergency Director and is responsible for directing the Exelon Emergency Public Information Organization and providing news information to the media. Responsibilities include:
  • Maintain command and control of the Joint Information Center.
  • Coordinate with Federal, state and local agencies, as well as with other organizations involved in the emergency response, to maintain factual consistency of information to be conveyed to the news media/public.
  • Conduct periodic briefings with the news media.
  • Interface with the Public Information Director.
  • Coordinate and direct responses to media inquiries.
  • Ensure that the composition and timeliness of Exelon News Releases are adequate.
  • Provide for timely exchange of information between other spokespersons.
2) Technical Spokesperson JIC The Technical Spokesperson reports to the Corporate Spokesperson.

Responsibilities include:

  • Assist in development of technical and plant status information for use in news releases and media briefings.
  • Assist the Events Recorder in the preparation of a chronological event description log.
  • Prepare briefing papers which contain additional detail and background not found in the news releases.
  • Provide answers as soon as possible to media questions.
  • Provide a follow-up explanation that corrects misinformation as soon as practicable.
3) Radiation Protection Spokesperson JIC The Radiation Protection Spokesperson reports to the Corporate Spokesperson. Responsibilities include.

December 2017 B-31 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Assist in development of environmental and health physics information for use in news releases and media briefings.
  • Assist the Events Recorder in the preparation of a chronological event description log.
  • Prepare briefing papers which contain additional detail and background not found in the news releases.
  • Provide answers as soon as possible to media questions.
  • Provide a follow-up explanation that corrects misinformation as soon as practicable.
4) JIC Director JIC The JIC Director reports the Corporate Spokesperson to ensure the operability of and to supervise the activities in the JIC. Responsibilities include:
  • Maintain cognizance of conditions of the plant and environment, and the actions of Exelon Nuclear and governmental support personnel.
  • Coordinate with Federal, state and local agencies, as well as with other organizations involved in the emergency response, to maintain factual consistency of information to be conveyed to the news media/public.
  • Participate, as needed, in rumor control activities.
  • Ensure that adequate information flow between the EOF and the JIC is coordinated through the Public Information Director.
  • Authorize admittance of non-Exelon Nuclear officials to the JIC.
  • Until the JIC is fully staffed, work with Corporate Communications to compose draft news releases.
  • Provide the drafted news releases to the Corporate Emergency Director for technical review prior to Public Information Director approval.
  • Until the JIC is fully staffed, work with Corporate Communications to ensure that rumors are reviewed, documented and responded to by Exelon Nuclear personnel as deemed appropriate.
  • Until the JIC is fully staffed, work with Corporate Communications to document and respond to rumors as quickly as possible, through the Exelon Communications and Public Affairs.

December 2017 B-32 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Until the JIC is fully staffed, work with Corporate Communications to ensure that the media is being monitored and that Exelon Nuclear personnel review the information detailed or contained in media releases.
5) JIC Coordinator JIC The JIC Coordinator reports to the JIC Director and supervises the facilities support staff. Responsibilities include:
  • Ensure the JIC is activated and operational. This includes the availability of communications and visual aids.
  • Ensure that access to the JIC areas occupied by Exelon personnel is controlled.
  • Establish a minimum frequency for addressing news media/public representatives and ensure that some form of communication occurs within that time frame (i.e., an update at least hourly.)
  • Ensure that approved News Releases and Chronological Event Description Logs are made available in the JIC.
  • Document unanswered questions and serious public misinformation issues. Follow-up on these questions and issues to ensure that they are being adequately addressed.
  • Coordinate the interface between Exelon Nuclear and the news media/public, including, as necessary, briefings, news conferences, interviews and responses to information requests.
7) Administrative Coordinator JIC The Administrative Coordinator reports to the JIC Director. Responsibilities include:
  • Coordinate with the EOF Administrative Coordinator to ensure the clerical requirements for the other JIC staff are met.
  • Coordinate shift relief and continual staffing for the JIC.
  • Obtain services as appropriate to support operation of the JIC.

December 2017 B-33 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

8) Access Controller JIC The Access Controller reports to the JIC Director and is responsible for controlling facility access and obtaining authorization prior to admitting non-Exelon Nuclear officials into the JIC.
9) Public Information Director (PID) JIC When the Emergency Public Information Organization is activated, the Public Information Director reports to the Corporate Spokesperson and is responsible for all emergency event related information intended to be conveyed from Exelon Nuclear to the news media/public. The Public Information Director may perform this function at remote locations. The Public Information Director supervises the activities of the, News Writer, Events Recorder and media monitoring and rumor control personnel. Responsibilities include:
  • Provide the Corporate Emergency Director with an overview of the public and media impacts resulting from the Exelon Nuclear and governmental activities.
  • Participate with the Corporate Emergency Director regarding information to be released to the public.
  • Authorize the issuance of news releases.
  • Interface with the Corporate Spokesperson at the JIC.
  • Act as a liaison between the ERO and Exelon Nuclears corporate executives.
  • Maintain cognizance of conditions of the plant and environment, and the actions of Exelon Nuclear and governmental support personnel.
  • Coordinate information flow between the EOF and the JIC.
  • Coordinate with the Media Monitoring Staff to rReview and access media coverage of the emergency event.
10) News Writer JIC The News Writer reports to the Public Information Director. Responsibilities include:
  • Compose draft news releases with assistance from the Technical Spokesperson and the Radiation Protection Spokesperson.
  • Provide the drafted news releases to the Corporate Emergency Director for technical review prior to Public Information Director approval.

December 2017 B-34 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

11) Events Recorder JIC The Events Recorder reports to the Public Information Director.

Responsibilities include:

  • Develop a chronological event description log.
12) Media Monitoring Staff JIC The Media Monitor reports to the Public Information Director. Responsibilities include:
  • Ensure that the media is being monitored and that Exelon Nuclear personnel review the information detailed or contained in media releases.
  • Inform the Public Information Director of all media reports and of actions taken to correct any misinformation or rumors.
  • Direct the activities of the Rumor Control Staff with respect to the function of monitoring rumors from sources other than the media.
13) Rumor Control Staff JIC The Rumor Control Staff reports to the Public Information Director and acts in support of the Media Monitors. Responsibilities include:
  • Ensure that rumors are reviewed, documented and responded to by Exelon Nuclear personnel as deemed appropriate.
  • Until the JIC is fully activated, document and respond to rumors as quickly as possible, through the Exelon Communications and Public Affairs.
  • Inform the Media Monitors when rumors representing serious misinformation are encountered.
6. Exelon Emergency Response Organization Block Diagram ERO staffing tables contained within the station specific Annexin Appendix 5, lists the key positions of the ERO and the supporting positions assigned to interface with federal, state, and county authorities. Figures B-1a through B-1d illustrates the overall emergency response organization. Section B.5 discusses specific responsibilities and the interrelationships for key positions.
7. Exelon Corporate Emergency Response Organization The Corporate ERO consists of the EOF Organization and the Emergency Public Information Organization. Personnel staffing these corporate organizations are covered in detail in Section B.5 of this plan.

December 2017 B-35 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear The Corporate Emergency Response Organization is staffed by Exelon personnel, and operates out of the Emergency Operations Facility (EOF) and the Joint Information Center (JIC). The Corporate ERO is supported by News Media Spokespersons, environmental assessment staff and monitoring teams that provide long-term support to the affected station. Additionally, the Corporate ERO has long term liaison responsibilities with federal, state, and local authorities. These positions are further described in the EPIPs.

The Emergency News Center (ENC) function is responsible for the collection and analysis of event information and status, and development of Company news statements. This information is then communicated to the JIC Corporate Spokespersons. The ENC function may be located at either the EOF or the JIC.

The Corporate ERO EOF is activated at an Alert. The EOF Organization is responsible for evaluating, coordinating and directing the overall company activities involved in the emergency response. Within the EOF, the Corporate Emergency Director shall assume Command and Control from the Station Shift Emergency Director when classification escalates to an Alert or higher, unless the EOF capabilities are limited such that the overall control and responsibility for PARs and offsite notifications cannot be assumed. The EOF may also function in a supporting role to the station when the Station Emergency Director maintains Command and Control. The JIC is activated within 90 minutes of an Alert. Some JIC functions may continue to be performed by the Exelon Communications organization until transferred to the JIC.

8. Industry/Private Support Organizations Exelon Nuclear retains contractors to provide supporting services to nuclear generating stations. A contract/purchase order with a private contractor is acceptable in lieu of an agreement letter for the specified duration of the contract. Among services currently provided are the following:
a. Institute of Nuclear Power Operations (INPO): Experience has shown that a utility may need resources beyond in-house capabilities for the recovery from a nuclear plant emergency. One of the roles of the Institute of Nuclear Power Operations (INPO) is to assist affected utilities by quickly applying the resources of the nuclear industry to meet the needs of an emergency. INPO has an emergency response plan that enables it to provide the following emergency support functions:
  • Assistance to the affected utility in locating sources of emergency personnel, equipment and operational analysis.
  • INPO, Electric Power Research Institute (EPRI) and Nuclear Energy Institute (NEI) maintain a coordination agreement on emergency information with their member utilities.
  • INPO provides the "Nuclear Network", or its replacement, electronic communications system to its members, participants, NEI, and EPRI to coordinate the flow of media and technical information about the emergency.

December 2017 B-36 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Figure B-1a: Exelon Overall ERO Command Structure Corporate Emergency Director EOF Station Corporate Director Emergency Spokesperson Director Shaded/Bold Boxes indicate minimum staffing positions.

December 2017 B-41 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Figure B-1b: Emergency Onsite Organization Station Emergency Director

  • Security TSC Coordinator Director State/Local Logistics Communicator Coordinator Clerical Support Rad Protection Maintenance Operations Technical Manager Manager Manager
  • Manager
  • Technical Rad Controls Rad Controls OSC Damage Control ENS Operations Communicator Coordinator Engineer Director Communicator Communicator Communicator (TSC)

(TSC) (TSC)

Core/Thermal HPN Asst OSC Damage Control Control Room Engineer Communicator Director Communicator Shift Manager (OSC)

Mechanical Control Room Engineer Operations Shift Staff Mechanical Electrical/I&C Rad Protection Chemistry Pool (2) Pool (3) Pool (8) Pool (1) Pool Electrical Operations Engineer Communicator Shaded/Bold Boxes indicate minimum staffing positions. (in CR)

ERO response pool personnel do not include the on-shift complement. Damage Cont Communicator

  • SAMG functions may be assigned to other qualified personnel. Minimum staffing (in CR) requires 1 Decision-Maker and 2 Evaluators.

December 2017 B-42 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Figure B-1c: Emergency Offsite Organization EOFEmergency Director Rad Protection Technical _______

Logistics Manager Support Manager _______

Manager Environmental Dose Assmt Operations Technical Security State/Local Coordinator Coordinator Advisor Advisor Coordinator Communicator ENS Events Administrative Regulatory State Environs Dose Communicator Records Coordinator Liaison Communicator Assessor EOC Computer Field Team HPN ____________

Communicator Specialist Communicator Communicator Clerical Field Monitoring Support State EOC Teams (2) Liaisons County EOC Liaisons Shaded/Bolded Boxes indicate minimum staffing positions.

December 2017 B-43 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Figure B-1d: Emergency Public Information Organization Corporate Spokesperson JIC Technical Rad Protection Public Info Director Spokesperson Spokesperson Director Administrative JIC Access News Coordinator Coordinator Controller Writer Events Facility Support Recorder Staff Media Monitoring Staff Rumor Control Staff Shaded/Bolded Boxes indicate minimum staffing positions.

December 2017 B-44 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

9) Field Monitoring Team (FMT) Communications: A separate communications system has been installed to allow coordinated environmental monitoring and assessment during an emergency. This system consists of the necessary hardware to allow communication between the Control Room, TSC, EOF, and mobile units in Exelon Nuclear vehicles. Though direct communications between the Control Room and the FMTs is not required per the prescribed methods of FMT coordination, the FMTs can be contacted from equipment in the Control Room if required. Commercial cell phones or other means are available as back up to the primary field team communications system.

In addition, station communication links exist to ensure appropriate information transfer capabilities during an emergency. The station may also utilize its Public Address System, station radios and notification devices to augment its emergency communications.

e. ERO Notification System: Exelon Nuclear utilizes an automated ERO Notification System to rapidly notify members of the ERO. The system consists of a network of physical infrastructure capable of initiating and receiving contact via multiple notification devices. When activated, the system contacts the notification devices (e.g., through commercial and cellular phone, email, text message) belonging to members of the ERO. The System includes redundant activation methods via the internet, call-centers, or direct telephone activation, as well as redundant, geographically separated call centers and data centers, with redundant power sources. Implementing procedures specify the course of action to be taken if the primary ERO Notification System activation path fails to respond. The ERO Notification System provides primary and back-up notification functions. For the Exelon North East sites, the ERO notification system description is contained in the Station Annex and EP implementing procedures.
f. NRC Communications (ENS and HPN)

Communications with the NRC Operations Center will be performed via the NRC ENS and HPN circuits or commercial telephone line. Information is normally communicated from an approved NRC Event Notification Worksheet prior to establishing an open ENS and/or HPN line.

The actual configuration of these systems may vary from station to station.

Installation and use of these NRC telephones is under the direction of the NRC (see Figure F-3).

Emergency Notification System (ENS): Dedicated telephone equipment is in place between each nuclear station's Control Room and the NRC, with an extension of that line in the TSC. A separate line is available in the EOF with the capability of being patched with the station through the NRC. This line is used for NRC event notifications and status updates.

Health Physics Network (HPN): There also exists a separate dedicated telephone between the NRC, the TSC, and EOF for conveying health physics information to the NRC as requested or as an open line.

December 2017 F-3 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Figure F-3: NRC Communications for Nuclear Response NRC Control Headquarters Room patch TSC Commercial only NRC Region EOF NOTE: ENS and HPN circuits may use the Federally maintained system, company tie lines or PBX as dedicated primary communications systems and have commercial backups.

December 2017 F-7 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear The primary purpose of the Emergency Public Information Organization is to disseminate information from Exelon Nuclear's ERO about the emergency events to the public, via the news media. However, the authority for issuance of news releases for the classification of an Unusual Event or prior to ERO activation will always reside with the Exelon Communications and Public Affairs Department. Upon activation, the Emergency Public Information Organization has the responsibility and authority for issuance of news releases to the public.

The Emergency Public Information Organization is comprised of senior managers from Exelon Nuclear who will function as spokespersons, and other Exelon Nuclear individuals including personnel from the Governmental Affairs and Human Relations areas. Exelon Nuclear's spokespersons disseminate information to the news media/public concerning the emergency events out of a Joint Information Center (JIC).

2) The Joint Information Center (JIC): The JIC is the facility in which media personnel gather to receive information related to the emergency event. The JIC is the location where approved news releases will be provided to the media for dissemination to the public. News releases are coordinated between the EOF and JIC personnel and state and/or Federal representatives in the JIC. Exelon public information personnel operate from the EOF and the JIC, which is under the direction of the Corporate Spokesperson and functions as the single point contact to interface with Federal, state, and local authorities who are responsible for disseminating information to the public.

Each station has a designated JIC. Each JIC is equipped with appropriate seating, lighting and visual aids to allow for public announcements and briefings to be given to the news media. Additionally, JICs are equipped with commercial telephone lines for making outgoing calls. The Emergency Public Information Organization functions from the JIC and EOF in preparing and releasing utility information about the emergency event. The JIC is activated at the declaration of an Alert or higher classification. Some JIC personnel may perform functions remotely from alternate locations while remaining in contact with personnel in the JIC facility (e.g., media monitoring, rumor control, news writers, issuance of press releases). The JIC Director and Corporate Spokesperson will ensure communication and coordination of these functions with the EOF and JIC staff. Functions of the JIC include:

  • Serving as the primary location for accumulating accurate and current information regarding the emergency conditions and writing news releases.
  • Providing work space and phones for public information personnel from the state, counties, NRC, FEMA, and industry-related organizations.
  • Providing telephones for use by the news media personnel.

December 2017 G-2 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

  • Providing responses to media inquiries through Media Monitoring Staff telephones that the media can call for information about an emergency.
b. The news media is not permitted into the EOF during an emergency.
4. Coordination of Public Information
a. The JIC is staffed by Exelon and government public information representatives who will be the source of public information during an emergency at the station.

The Corporate Spokesperson is the primary spokesperson for Exelon Nuclear.

The Corporate Spokesperson has direct access to all necessary information (see Section B.5).

b. The JIC is staffed by federal, state, county, and utility personnel to assure timely, periodic exchange and coordination of information. Representatives coordinate information prior to conducting news briefings.
c. Rumors or misinformation are identified during an emergency by the media/rumor control monitorsJIC Staff. They respond to public and news media calls and monitor media reports.
d. The common MW Region JIC is located west of Chicago, in Warrenville IL, in the Exelon Nuclear Cantera facility. This facility supports the Braidwood, Byron, Clinton, Dresden, LaSalle and Quad Cities stations.

The JIC for the MA Region Three Mile Island, Limerick and Peach Bottom Stations is co-located with the EOF at 175 North Caln Road, Coatesville, Pennsylvania.

The JIC for Calvert Cliffs Station is co-located with the EOF about twelve miles from the site, in Calvert Industrial Park, Skipjack Road at Hallowing Point Road.

The JIC for the Ginna Station is located at 1255 Research Forest, Macedon, NY.

The JIC for the Nine Mile Point Station is located near the Oswego County Airport, on County Route 176 in the Town of Volney, New York approximately 12 miles from the site.

5. Media Orientation Emergency Preparedness, in conjunction with Exelon Communications and Public Affairs Department, offers training (at least annually) to acquaint news media with the E-Plan, information concerning radiation, and points of contact for release of public information in an emergency. Training is provided for those media agencies that accept the training offer.

December 2017 G-3 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear Personnel in the TSC shall be protected from radiological hazards, including direct radiation and airborne contaminants under accident conditions with similar radiological habitability as Control Room personnel. To ensure adequate radiological protection, permanent radiation monitoring systems have been installed in the TSC and/or periodic radiation surveys are conducted. These systems indicate radiation dose rates and airborne radioactivity inside the TSC while in use. In addition, protective breathing apparatus (full-face air purifying respirators) and KI are available for use as required.

The TSC has access to a complete set of as-built drawings and other records, including general arrangement diagrams, P&IDs, and the electrical schematics.

The TSC has the capability to record and display vital plant data, in real time, to be used by knowledgeable individuals responsible for engineering and management support of reactor operations, and for implementation of emergency procedures.

c. Operations Support Center (OSC): Each nuclear generating station has established an OSC. The OSC is the onsite location to where station support personnel report during an emergency and from which they will be dispatched for assignments or duties in support of emergency operations. The OSC shall be activated whenever the TSC is activated, but need not remain activated at the Alert level if its use is judged unnecessary by the Station Emergency Director. At the Site Area and General Emergency levels, the OSC or an alternate OSC shall be activated at all times. The OSC is not activated for a HOSTILE ACTION when the Alternative Facility is implemented. Activation for other events is optional.

Station disciplines reporting to the OSC include, but are not limited to:

  • Operating personnel not assigned to the Control Room,
  • Radiation Protection Personnel,
  • Chemistry Personnel,
  • Maintenance Personnel (mechanical, electrical and I&C).

Figure B-1b illustrates the staffing and organization for the OSC.

Each OSC is equipped with communication links to the Control Room, the TSC and the EOF (see Section F). A limited inventory of supplies will be kept for the OSC. This inventory will include respirators, protective clothing, flashlights and portable survey instruments.

2. Emergency Operations Facility (EOF)

The EOF is the location where the Corporate Emergency Director will direct a staff in evaluating and coordinating the overall company activities involved with an emergency. Activation of the EOF is mandatory upon declaration of an Alert or higher classification. The EOF provides for:

  • Management of overall emergency response.

December 2017 H-3 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear

3. Emergency Operations Centers EOCs operated by the state and local communities have been established to perform direction and control of emergency response functions.

The respective state EOCs are capable of continuous (24-hour) operations for a protracted period. These centers contain sufficient communications (radio, telephone and teletype) equipment, maps, emergency plans, and status boards to provide the necessary interfaces with other federal, state, county, and Exelon emergency facilities.

The county EOCs serve as Command and Control headquarters for local emergency response activities as well as a center for the coordination of communications to field units and to the state EOCs. These EOCs have the equipment necessary, (such as facsimile machines, telecommunications equipment, radio gear, photocopiers, wall maps, etc.) to carry out their emergency responsibilities.

4. Activation NOTE: NUREG-0654 Criterion II.B.5 states that the licensee must be able to augment on-shift capabilities within a short period after declaration of an emergency. It further defines that short period as 30 and 60 minutes. The time frames for rapid augmentation of a nuclear power plant staff in the event of an emergency are not rigid inviolate requirements but rather goals. It is Exelon Nuclears intent to expend its best efforts to meet the augmentation criteria goals regarding staffing Emergency Response Facilities with sufficiently skilled individuals capable of handling an emergency. Both the NRC and Exelon Nuclear realize that due to diversity of normal residential patterns for the stations staff, possible adverse weather conditions, road congestion and site access restrictions, these time frames might be exceeded.

Exelon Nuclear has put into place plans and procedures to ensure timely activation of its emergency response facilities. The Shift Manager (as Shift Emergency Director) will initiate a call-out in accordance with the implementing procedures. The ERO augmentation process identifies individuals who are capable of fulfilling the specific response functions that are listed in ERO staffing tables contained within the station specific Annex. This table was developed based on the functions listed in NUREG-0654, Table B-1.

Although the response time will vary due to factors such as weather and traffic conditions, a goal of 60 minutes for minimum staffing, following the declaration of an Alert or higher emergency classification, has been established for the ERO personnel responding to the station emergency facilities and the EOF. Additionally, plans have been developed to ensure timely functional activation and staffing of the JIC within 90 minutes of when the classification of Alert is declared.

December 2017 H-5 EP-AA-1000 (Revision 2930)

PART II: Planning Standards And Criteria Exelon Nuclear It is the goal of the organization to be capable of activating the applicable Emergency Response Facility upon achieving minimum staffing. The facility can be declared activated when the following conditions are met:

a. Minimum staffing has been achieved.
b. The facility is functional.

Although the minimum staffing criteria applies to the JIC, the activation time is not applicable. Public Information personnel must first coordinate the decision to activate the JIC with the appropriate offsite authorities.

The Director in charge may elect to activate their facility without meeting minimum staffing; if it has been determined that sufficient personnel are available to fully respond to the specific event (this would not constitute a successful minimum staff response).

5. Monitoring Equipment Onsite Each nuclear station is equipped with instrumentation for seismic monitoring, radiation monitoring, fire protection and meteorological monitoring. Instrumentation for the detection or analysis of emergency conditions is maintained in accordance with station Technical Specifications, if applicable, or commitments made to the NRC. The actual instrumentation varies somewhat from site to site and thus will not be described in detail in this plan. Descriptions of the equipment will appear in each Station Annex. This equipment includes but is not limited to the following:
a. Geophysical Monitors
1) Meteorological Instrumentation: A permanent meteorological monitoring station is located near each station for display and recording of wind speed, wind direction, and ambient and differential temperature for use in making offsite dose projections. Meteorological information is presented in the CR, TSC, and EOF by means of the plant computer system. This information is remotely interrogated using a computer or other data access terminal.

With regard to Exelon Nuclears meteorological monitoring program, there has been a quality assurance program adopted from 10 CFR 50, Appendix B.

However, since the meteorological facilities are not composed of structures, systems, and components that prevent or mitigate the consequences of postulated accidents and are not "safety related," not all aspects of 10 CFR 50, Appendix B, apply. Those aspects of quality assurance germane to supplying good meteorological information for a nuclear power station were adopted into the meteorological quality assurance program. The meteorological program is also subject to the requirements of the QATR, Section 19, Augmented Quality.

December 2017 H-6 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear Appendix 5 Table 5-1: Emergency Response Organization (ERO) Staffing and Augmentation Plan EOF - Alert or TSC / OSC Greater Alert or Greater Alert or Greater Augment Emergency w/in 60 min.

Augment Augment Preparedness (EP) On-Shift w/in 60 min. w/in 90 min.

Functions Command and Control

  • Provide overall ERO command and control, until relieved.
  • Approve emergency (1) Shift (1) Station Not applicable (1) Corporate action level (EAL) Emergency Emergency Emergency and/ or protective Director Director Director action recommendation (PAR) classifications, until relieved.
  • Authorize personnel dose extensions, until relieved.

Communications3

  • Communicate EAL and PAR (1) ENS classifications to Shift Communicator (1) State / Local Not applicable Communicator offsite response Communicator1 (TSC) organizations (OROs),

including the NRC, until relieved.

Radiation Protection

  • Provide qualified radiation protection coverage for (3) Additional responders (3) Additional Radiation accessing potentially (2) Radiation Radiation Protection Protection Protection Technicians [In Not applicable unknown radiological environments during Personnel Technicians [In addition to emergency addition to personnel on-shift conditions. personnel on-shift] and those (OSC) responding within
  • Provide in-plant surveys. 60 min.] (OSC)
  • Control dosimetry and radiologically controlled area access.

December 2017 Appendix 5 Page 1 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear EOF - Alert or TSC / OSC Greater Alert or Greater Alert or Greater Augment Emergency w/in 60 min.

Preparedness On-Shift Augment Augment w/in (EP) Functions w/in 60 min. 90 min.

Supervision of Radiation Protection Staff and Site Radiation Protection

  • Evaluate and assess plant and offsite radiological data in the development of onsite protective actions and offsite PARs, until relieved.
  • Recommend onsite (1) TSC Radiation (1) Shift Protection Manager Not applicable (1) EOF Radiation protective actions Emergency Protection and offsite PARs to (RPM) (TSC)

Director Manager (EOF) the applicable decision- maker, until relieved.

  • Direct all radiation protection activities, including field monitoring team (FMT) direction, until relieved.
  • Provide relevant information to applicable communicators who are communicating offsite PARs to OROs, until relieved.

Dose Assessments/

Projections (1) Dose (1) Shift Dose Not Applicable

  • Perform dose Not applicable Assessment Assessor 1 Coordinator assessments/projectio ns and provide input (EOF) to applicable PAR decision- maker, until relieved.

December 2017 Appendix 5 Page 2 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear EOF - Alert or TSC / OSC Greater Alert or Greater Alert or Greater Augment Emergency w/in 60 min.

Augment Augment w/in Preparedness On-Shift w/in 60 min. 90 min.

(EP) Functions Emergency Classifications Emergency Classification (1) Operations

  • Evaluate plant Advisor1 Not applicable Not applicable Manager (TSC) conditions and recommend emergency classifications, until relieved.

TSC Engineering Staff

  • (1) Electrical/

Instrumentation and Control (I&C):

Engineering Provide (1) Core/

engineering

  • Provide engineering Thermal coverage for the coverage related to Hydraulics ERO related to As needed Not applicable the specific discipline Engineer - electrical or I&C of the assigned STA1 equipment.

engineer, until

  • Evaluate * (1) Mechanical:

relieved.

reactor Provide conditions. engineering coverage for the ERO related to mechanical equipment.

  • (1) Core/Thermal Hydraulics:

Evaluate reactor conditions.

(1) Security Coordinator (TSC)

Security staffing

  • Coordinate Security per the site- security- related Not applicable Not applicable specific security activities and plan. information with the Emergency Coordinator.

December 2017 Appendix 5 Page 3 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear EOF - Alert or TSC / OSC Greater Alert or Greater Alert or Greater Augment Emergency w/in 60 min.

Preparedness On-Shift Augment Augment (EP) Functions w/in 60 min. w/in 90 min.

Maintenance Personnel Maintenance (OSC)

Operations Personnel * (1) I&C Staff1,4 (OSC) Technician:

  • Limited * (1) Electrical Provide maintenance Maintenance assistance with capability Technician: logic needed on- Provide manipulation, Repair Team Activities shift. This is electrical support for event Not applicable typically support for mitigation and limited to minor ECCS equipment repair, electrical and/ equipment, and support or mechanical event of digital I&C work to mitigation, and if applicable.

restore power equipment Additional I&C and/or repair. staff may be emergency called out if core cooling * (1) Mechanical needed.

system Maintenance (ECCS) flow. Technician: Provide mechanical support

  • Electrical for ECCS Maintenance equipment, event Technicians - As mitigation, and needed.

equipment repair.

  • Mechanical Maintenance Technicians - As needed.

December 2017 Appendix 5 Page 4 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear EOF - Alert or TSC / OSC Greater Alert or Greater Alert or Greater Augment Emergency w/in 60 min.

Preparedness On-Shift Augment Augment (EP) Functions w/in 60 min. w/in 90 min.

OSC Supervisors

  • (1) Electrical Maintenance Supervisor

/Lead:

Supervise OSC activities related to electrical (1) OSC equipment.

Director Supervision of (1) Repair

  • Supervise OSC Not applicable Repair Team Team activities as * (1) Mechanical Activities Supervisor1 directed by Maintenance Emergency Supervisor /

Coordinator. Lead:

Supervise OSC activities related to mechanical equipment.

  • (1) I&C Supervisor /

Lead: Supervise OSC activities related to I&C equipment. May be combined with Electrical Supervisor.

  • (1) Radiation Protection Supervisor / Lead:

Supervise OSC activities related to radiation protection.

December 2017 Appendix 5 Page 5 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear EOF - Alert or TSC / OSC Greater Alert or Greater Alert or Greater Augment Emergency w/in 60 min.

Augment Augment Preparedness (EP) On-Shift w/in 60 min. w/in 90 min.

Functions Onsite FM Individual

  • (1) Qualified individual to assess the protected area for radiation and contamination and provide input to the TSC RPM.

Responsible for Offsite FMT B radiation protection coverage for the * (1) Qualified FMT as directed individual to by TSC RPM or assess the area(s)

EOF RPM. outside the protected area for

. radiation and contamination, Offsite FMT A and for radioactive

  • (1) Qualified plume tracking, as individual to assess directed by, and Field Monitoring Not applicable under the control Not applicable the area(s) outside Teams (FMTs) of, the EOF DAC the protected area for radiation and or RPM.

contamination, and Responsible for for radioactive the radiation plume tracking, as protection directed by, and coverage of the under the control of, FMT as directed the EOF DAC or by EOF RPM.

RPM. Responsible * (1) Driver to for the radiation provide protection coverage transportation.

of the FMT as directed by EOF RPM.

  • (1) Driver to provide transportation.

December 2017 Appendix 5 Page 6 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear TSC / OSC EOF/JIC - Alert or Greater2 Augment Alert or Greater Alert or Greater w/in 90 min.

Emergency Preparedness On-Shift Augment Augment (EP) Functions w/in 60 min. w/in 90 min.

Media Information

  • Manage and Not applicable Not applicable Not applicable Corporate coordinate media Spokesperson information related to the event.
  • Public Information Director
  • Other personnel may be assigned this function if no collateral duties are assigned to an individual that are beyond the capability of that individual to perform at any given time.

December 2017 Appendix 5 Page 7 EP-AA-1000 (Revision 2930)

PART III: Appendices Exelon Nuclear TSC / OSC EOF/JIC - Alert or Greater2 Augment w/in 90 Emergency On-Shift Alert or Greater Alert or Greater Preparedness (EP)

Functions Augment w/in 60 Augment w/in 90 min. min.

JIC/EOF * (1) EOF/JIC Not applicable Not applicable Not applicable Information Computer Technology (IT) Specialist (@

90 min from Alert or higher)

1. Other personnel may be assigned this function if no collateral duties are assigned to an individual that are beyond the capability of that individual to perform at any given time.
2. Exelons Communication Department will perform necessary JIC functions at the Unusual Event declaration and initially upon a higher initial EAL declaration. The JIC facility will be activated within 90 minutes of an Alert declaration; however, some functions may continue to be performed by the Exelon Communications Department. Some JIC functions such as Public Information Director, New Writer, Media Monitor, Rumor Control may be performed remotely by Exelons Communication Department.
3. Additional Communications will be staffed at the EOF or TSC if needed.
4. At Clinton, one (1) Repair Team Activity position is filled by a station IMD person. The IMD person is annotated in this table to support performance of specific EOP activities such as lifting leads and installing jumpers. The IMD person is required on shift until such time that operators are trained and qualified to perform these tasks.

December 2017 Appendix 5 Page 8 EP-AA-1000 (Revision 2930)

Emergency Plan Annex EP-AA-1001 Affected Pages - Mark-ups

EP-AA-1001 Revision 3435 EXELON NUCLEAR RADIOLOGICAL EMERGENCY PLAN ANNEX FOR BRAIDWOOD STATION

Braidwood Annex Exelon Nuclear Table of Contents Section Page Section 1: Introduction BW 1-1 1.1 Facility Description BW 1-1 1.2 Emergency Planning Zone BW 1-2 Section 2: Organizational Control of Emergencies BW 2-1 2.1 Shift Organization Staffing BW 2-1 2.2 Emergency Response Organization Block Diagram BW 2-1 2.3 Non-Exelon Nuclear Support Groups BW 2-1 Section 3: Classification of Emergencies BW 3-1 Section 4: Emergency Measures BW 4-1 4.1 Notification of the Emergency Organization BW 4-1 4.2 Assessment Actions BW 4-1 4.3 Protective Actions for the Offsite Public BW 4-1 4.4 Protective Actions for Onsite Personnel BW 4-2 Section 5: Emergency Facilities and Equipment BW 5-1 5.1 Emergency Response Facilities BW 5-1 5.2 Assessment Resources BW 5-1 5.3 Protective Facilities and Equipment BW 5-6 5.4 First Aid and Medical Facilities BW 5-6 5.5 Law Enforcement Agencies BW 5-6 5.6 Fire Fighting Organizations BW 5-7 5.7 EMS Support BW 5-7 APPENDIXES Appendix 1: NUREG-0654 Cross-Reference Appendix 2: Station Letters of Agreement ADDENDUMS Addendum 1: On- Shift Staffing Technical Basis Addendum 2: Evacuation Time Estimates for Braidwood Generating Station Plume Exposure Pathway Emergency Planning Zone Addendum 3: Emergency Action Levels for Braidwood Station November 2017 iii EP-AA-1001 (Revision 3435)

Braidwood Annex Exelon Nuclear Section 2: Organizational Control of Emergencies Braidwoods Emergency Response Organization (ERO) and its key positions are described in the Exelon Nuclear Standardized Radiological Emergency Plan (EP-AA-1000).

This section describes the Emergency Response Organization (ERO) and its key positions. It outlines the staffing requirements which provide initial emergency response actions and provisions for timely augmentation of on-shift personnel when required. It also describes interfaces among Exelon Nuclear emergency response personnel and specifies the offsite support available to respond to the nuclear generating stations.

2.1 Shift Organization Staffing Initial response to any emergency is by the normal plant organization present at the site. This organization includes positions that are onsite 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per day and is described in Section B.1 of the Exelon Nuclear Standardized Radiological Emergency Plan. The Normal Shift Organization will be augmented, in an emergency, with designated/additional Emergency Response Organization (ERO) personnel within 60 minutes following the declaration of an Alert or higher emergency classification as specified under Table 2-1. ERO activation is described in Section H.4 of the Exelon Nuclear Standardized Radiological Emergency Plan.

Table 2-1 outlines ERO positions required to meet minimum staffing and full augmentation of the on-shift complement at an Alert or higher classification, and the major tasks assigned to each position. Responsibilities for each position are described in Section B.5 of the Exelon Nuclear Standardized Radiological Emergency Plan.

2.2 Emergency Response Organization Block Diagram Figures B-1a through B-1d of the Exelon Nuclear Standardized Radiological Emergency Plan illustrates the overall emergency response organization.

2.3 Non-Exelon Nuclear Support Groups Exelon Nuclear has contractual agreements with several companies whose services would be available in the event of a radiological emergency. These agencies and their available services are listed in Appendix 3 of the Exelon Nuclear Standardized Radiological Emergency Plan.

Emergency response coordination with governmental agencies and other support organizations is discussed in Section A of the Exelon Nuclear Standardized Radiological Emergency Plan.

Site specific Agreements also exist on file at Braidwood Station with several support agencies. These agencies and their support roles are listed in Appendix 2, Station Letters of Agreement.

November 2017 BW-2-1 EP-AA-1001 (Revision 3435)

Braidwood Annex Exelon Nuclear Table 2-1: Minimum Staffing Requirements Minimum Staffing Functional Area Major Tasks Emergency Positions Minimum *60 Minute Other Full Shift Size Augmentation On- Augmentation Call

1. Plant Operations/Safe Control Room Staff Shift Manager 1 Shutdown and Assessment Shift Supervisor 1 of Operational Aspects Nuclear Station Operator 3 Non-Licensed Operator 4
2. Emergency Direction and Command and Control Shift Emergency Director (CR) 1(a)

Control Station Emergency Director (TSC) 1 Corporate Emergency Director (EOF) 1

3. Notification & Emergency Plant Shift Personnel 1 Communication Communications TSC Director (TSC) 1 EOF Director (EOF) 1 State/Local Communicator 1 (EOF) 1 (TSC)

ENS Communicator 1 (TSC) 1 (EOF)

HPN Communicator 1 (EOF) 1 (TSC)

Plant Status OPs Communicator (CR/TSC) 2 Operations Advisor (EOF) 1 In-Plant Team Control Damage Control Comm. (CR/TSC/OSC) 3 Technical Activities Technical Communicator (TSC) 1 Technical Advisor (EOF) 1 Governmental State Environs Communicator (EOF) (b)

EOC Communicator (EOF) 1 State EOC Liaison (State EOC) (b)

County EOC Liaison (County EOC) (b)

Regulatory Liaison (EOF) 1

4. Radiological Assessment Offsite Dose RP Personnel 1 Assessment Dose Assessment Coordinator (EOF) 1 Dose Assessor (EOF) 1 Radiation Controls Coordinator (TSC) 1 Offsite Surveys Environmental Coordinator (EOF) 1 Field Team Communicator (EOF) 1 Offsite Field Team Personnel 4 (b)

Onsite Surveys Onsite Field Team Personnel 2 (b)

In-plant Surveys RP Personnel 1 2 (b)

Chemistry Chemistry Personnel 1 1 (b)

RP Supervisory Radiation Protection Manager(TSC/EOF) 2 November 2017 BW-2-2 EP-AA-1001 (Revision 3435)

Braidwood Annex Exelon Nuclear Minimum Staffing Functional Area Major Tasks Emergency Positions Minimum *60 Minute Other Full Shift Size Augmentation On- Augmentation Call

5. Plant System Engineering, Technical Support STA / Incident Assessor (CR) 1 Repair, and Corrective Technical Manager (TSC) 1 Actions Core Thermal/Hydraulic Engineer (TSC) 1 Mechanical Engineer (TSC) 1 Electrical Engineer (TSC) 1 SAMG Decision-Maker (TSC) 1(a)

SAMG Evaluator (TSC) 2(a)

Operations Manager (TSC) 1 Radiation Controls Engineer (TSC) 1 Technical Support Manager (EOF) 1 Repair and Corrective Mechanical Maintenance (OSC) 1(a) 2 (b)

Actions Electrical/I&C Maintenance (OSC) 1(a) 3 (b)

Maintenance Manager (TSC) 1 OSC Director (OSC) 1 Assistant OSC Director (OSC) 1 OPs Lead & Support Personnel (OSC) (b)

6. In-Plant Protective Actions Radiation Protection RP Personnel 2(a) 4 (b)
7. Fire Fighting -- Fire Brigade(c) 5
8. 1st Aid and Rescue -- Plant Personnel 2(a) (b)

Operations

9. Site Access Control and Security & Security Team Personnel (d) (d)

Personnel Accountability Accountability Security Coordinator (TSC) 1 EOF Security Security Coordinator (EOF) 1

10. Resource Allocation and Logistics Logistics Manager (EOF) 1 Administration Logistics Coordinator (TSC) 1 Administration Administrative Coordinator (EOF) 1 Clerical Staff (TSC/EOF/JIC) (b)

Inter Facility Logs Events Recorder (EOF/JIC) 2 Facility Support Computer Specialist (EOF) 1 November 2017 BW-2-3 EP-AA-1001 (Revision 3435)

Braidwood Annex Exelon Nuclear Minimum Staffing Functional Area Major Tasks Emergency Positions Minimum *60 Minute Other Full Shift Size Augmentation On- Augmentation Call

11. Public Information Media Interface Corporate Spokesperson (JIC) 1 Rad Protection Spokesperson (JIC) 1 Technical Spokesperson (JIC) 1 Information Public Information Director 1 Development News Writer 1 Media Monitoring and Media Monitoring Staff (b)

Rumor Control Rumor Control Staff (b)

Facility Operation and JIC Director (JIC) 1 Control JIC Coordinator (JIC) 1 Administrative Coordinator (JIC) 1 Access Controls (JIC) 1 Facility Support Staff (JIC) (b)

TOTAL: 19 37 3 32(b)

  • Response time is based on optimum travel conditions.

(a) May be provided by personnel assigned other functions.

(b) Personnel numbers depend on the type and extent of the emergency.

(c) Fire Brigade per FSAR/Technical Specifications, as applicable.

(d) Function performed by on-shift security personnel.

November 2017 BW-2-4 EP-AA-1001 (Revision 3435)