Text
- -
'\\
v
~File No Pl0.2.1 In~ident No PAL-79-10-NC33 NPDES NONCOMPLIANCE NOTIFICATION Possible Noncompliance with Daily Average/Maximum Limi: Lio_n December 5, 1979 Plant:
Palisades Permit No MI-0001457 Outfall
Description:
Turbine Sump Oil Separator Outfall No 800218
- Parameter:
Oil/Grease Parameter No 00556
- 1.
Date of Incident:
10-15, 23, 29-79 2~
Identification of spe~ific effluent limitation exceeded:
Daily maximum limitation of 20 mg/l for oil and grease.
- 3.
Description of Incident:
Date Oil/Grease (Mg/l)
Volume '(Gallons) 10/15/79 41 9,000 10/23/79 29 5,000 10/29/79 24.1 3,000
- 4.
Apparent Cause:
The*problem was apparently caused by failure.of the oil separator or improper operation.
- 5.
If*not immediately corrected, the anticipated time the condition is expected to continue:
NA
- 6.
Corrective Action.- The following corrective action was taken or will be taken to reduce, eliminate and prevent recurrence:
The separat9t was restored t~ proper operation and subsequent ~nalysis shows results in the 1-10 mg/l range after:ll/1/79..
- 7.
Additional Comments:
NA
- 8.
Signed:
R L Fobes i-J,/;;cF~
7912180