CATEGORY 1 REGULAT(

INFORMATION DISTRIBUTIONSTEM (RIDS)

ACCESSiON NBR:9704250251 DOC.DATE: 97/04/ll NOTARIZED:

NO DOCKET FACIL:$0-220 Nine Mile Point Nuclear Station, Unit.1, Niagara Powe 05000220 AUTH.NAME AUTHOR AFFILIATION MCCORMICK,M.J.

Niagara Mohawk Power Corp; F~r RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk) A

SUBJECT:

Forwards approved

rept, "Analysis of Nine Mile Point Unit 1

Shroud Weld Cracking," for review.

DISTRIBUTION CODE:

A018D COPIES RECEIVED:LTR J ENCL i

SIZE: 2 + IM TITLE: GL 94-03 Intergranular Stress Corrosion Cracking of Core Shrouds in B

NOTES:

INTERNAL:

P RECIPIENT ID CODE/NAME HOOD,D CENTER 01 N

NRR/DSSA/SRXB COPIES LTTR ENCL 1

1 1

1 1

1 1

1 RECIPIENT ID.CODE/NAME NRR/DE/EMCB NRR/DRPM/PECB RES/DET/EMMEB COPIES LTTR ENCL 1

1 1

1 1

1 E

EXTERNAL: NRC PDR 1

1 D

E N

NOTE TO ALL MRIDS" RECZPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 8

ENCL 8

P N

k R

t I

NIAGARAMOHAWK G E N E RAT I 0 N BUSINESS GROUP NINE MILEPOINT NUCLEAR STATION/LAKEROAD, P O. BOX 63, LYCOMING.NEW YORK 13093/TELEPHONE (315) 349 2660 FAX(315) 349-2605 MARTINJ. McCORMICKJR. P.E.

Vice President Nuciear Engineering April 11, 1997 NMP1L 1203 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:

Nine MilePoint Unit 1 Docket No. 50-220

Subject:

Generic Letter 94-03 "Intergranular Stress Corrosion Cracking (IGSCC) in Boiling Water Reactors" Gentlemen:

By letter (NMP1L 1200) dated April8, 1997, Niagara Mohawk Power Corporation (NMPC) submitted to the NRC Staff the inspection results for the Nine MilePoint Unit 1 (NMP1) core shroud and a description of the proposed modification to the tie rod repairs previously installed. of that submittal made reference to a technical report that evaluates stress profiles for NMP1 core shroud vertical welds V9 and V10, which was prepared for NMPC by MPM Technologies.

At the time of the submittal, the report was still preliminary and had not yet been approved.

Contained herein is the approved report titled "Analysis of Nine MilePoint Unit 1 Shroud Weld Cracking," for your review.

Very truly yours, Martin

. McCormick Jr.

Vice President - Nuclear Engineering MJM/KLL/lmc Enclosure QQlF I

IIII3ll3lllllllllll)ll'HllllflllIIIIIIIlllll xc:

Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. S. S. Bajwa, Acting Director, Project Directorate I-l, NRR Mr. B. S. Norris, Senior Resident Inspector Mr. D. S. Hood, Senior Project Manager, NRR Records Management 970425025i 9704ii Poa

  • DoCX 0500022O PDR '..

UNITED STATES NUCLEARREGULATORYCOMMISSION In the Matter of Niagara Mohawk Power Corporation Nine MilePoint Unit 1 Docket No. 50-220 Martin J. McCormick Jr., being duly sworn, states that he is Vice President - Nuclear Engineering of Niagara Mohawk Power Corporation; that he is authorized on the part of said Corporation to sign and file with the Nuclear Regulatory Commission the document attached hereto; and that the document is true and correct to the best of his knowledge, information and belief.

Martin J. McCormick Jr.

Vice President '- Nuclear Engineering Subscribed and sworn before me, in and for the State of New York and the County of e

this ~~>~ day ofApril, 97.

NOTARYPUBLIC

~l ~+75~7

~-

>pg>hs JJ-~1~

I I

Report No. MPM-497439 Final Report entitled Analysis ofNine MilePoint Unit 1 Shroud Weld V9 and Weld Vlo Cracking Prepared for:

tlag Mh kP ~C 300 Erie Boulevard West Syracuse, New York 13202 by:

Dr: M:P.'Manahan, Sr.

and Dr. R. B. Stonesifer under contract to:

MPM Technologies, Inc.

P.O. Box 840, 915 Pike Street Lemont, PA 16851-0840 April, 1997 CCopyright l997 MPM Technologies, inc.

AllRights Reserved

..9704250251