Forwards SER on Plant Inservice Testing Program for Pumps & Valves.Three Requests Granted Conditionally,One Will Be Evaluated Against 10CFR50,App J Requirements,One Denied & Remainder Granted in Entirety
ML18033A767
Person / Time
Site: Browns Ferry  
Issue date: 05/19/1989
From: Black S
Office of Nuclear Reactor Regulation
To: Kingsley O
TENNESSEE VALLEY AUTHORITY
Shared Package
ML18033A768 List:
References
TAC-11324, TAC-11325, TAC-11326, NUDOCS 8905260350
Download: ML18033A767 (6)


Text

~p,I AEONS

+

I O~

Cy C

nO 0

+0'O

+)i**+

Docket Nos. 50-259, 50-260 and 50<<296 UNITEDSTATES NUCLEAR REGULATORYCOMMISSION WASHINGTON, D. C. 20666 Hay 19, 1989 Mr. Oliver D. Kingsley, Jr.

Senior Vice President, Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Hr. Kingsley:

SUBJECT:

SAFETY EVALUATION REPORT ON THE INSERVICE TESTING PROGRAM FOR PUMPS AND VALVES FOR BROWNS FERRY NUCLEAR PLANT, UNITS 1, 2 AND 3 (TAC NOS 11324,

11325, 11326)

The staff has completed an evaluation of the Browns Ferry Nuclear Plant (BFN),

Units 1, 2 and 3 Inservice Testing (IST) program.

This program evaluation addresses TVA's submittal dated March 25. 1988.

Previous IST submittals dated August 31, 1982, October 1, 1984, and December 23, 1986 were not completely reviewed and NRC approval of IST programs or relief requests was never completed for these earlier submittals.

In general, this program established the inservice testing that TVA will perform to meet 10 CFR 50.55a(g),

and contains certain relief requests from ASHE Code,Section XI.

The staff finds that the requests for relief from ASHE Section XI requirements are consistent with other similar BWR facilities.

The interval dates, August 31, 1982 through August 31, )992, have been approved by the Commission by letter dated March 18, 1988.

A BFN Technical Specifications (TS) change request submitted October 27, 1987 provides reference to IST code requirement.

Review of the TS change request has been completed,

approved, and issued November 27, 1988.

Thirty-one relief requests were submitted for evaluation.

Three are granted conditionally, one will be evaluated against 10 CFR 50, Appendix J requirements, one is partially denied, the remainder are granted in their entirety.

TVA should acknowledge, in writing, its understanding of the conditions of acceptance for those relief requests which have been granted conditionally or partially denied.

S90>>60850 85000PSq PDR P,DOCK 0 P

P

Mr. Oliver D. Kingsley 2>>

These relief requests are:

PV-3, "Five Minute Minimum Run Time for SLC and DFT Pump Tests;"

PV-4, "Requirements for Valve Operability Before Startup;"

PV-5, "Pump Test Instrumentation Accuracy and Full-Scale Requirements, Allowable Ranges of Inservice Test Quantities, and Vibration Amplitude Requirements;"

and PV-30, "Quarterly Exercising of the following RHR and CAD System Thermal Relief/Containment Isolation Check Valves".

If you have any questions contact Tom Daniels, Browns Ferry Project Manager on 301-492-0756.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required.

Sincerely, Original signed by

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Distribution NRC PDR Local PDR Projects Reading ADSP Reading D. Crutchfield B.

D. Liaw S. Black R. Pierson B. Wilson W. S. Little M. Simms Suzanne Black, Assistant Director for Projects TVA Projects Division Office of Nuclear Reactor Regulation T. Daniels G.

Gears D. Moran N. Markisohn OGC B. Grimes E. Jordan ACRS(10)

GPA/CA BFN Rdg. File E. Girard T.

Quay

  • SEE PREVIOUS CONCURRENCE

>><<>>>>>>>>>>>>t>>>>

NAME :MSimms

TDaniels:as
RPierson

~ >>>>>> <<>>

DATE: 4t /z'f/89: 9/g/89:

/z,W/89 OFFICIAL RECORD COPY

A 8.$

u 4.

(>udge.

SBlack

/89: 0 /

/89

~

~

~

~

V>>i i

I kirk i

k k.

I

~

h '

'E ~

.Ik k>>J U

f ID k>>

II k

k I,>> I I

k ID ID "'

D D

I k

Mr. Oliver D. Kingsley These relief requests are:

PV-3, "Five Minute Minimum Run Time for SLC and DFT Pump Tests;"

PV-4, "Requirements for Valve Operability Before Startup;"

PV-5, "Pump Test Instrumentation Accuracy and Full-Scale Requirements, Allowable Ranges of Inservice Test Quantities, and Vibration Amplitude Requirements;"

PV-30, "Closure Exercising Containment Inerting System Check Valve X-35f." 4

.l}

If you have any questions contact Tom Daniels, Browns Ferry Project Manager on 301-492-0756.

The reporting and/or recor dkeeping requirements contained in this 'letter affect fewer than ten respondents; therefore, OMB clearance is='-required.

Sincerely,

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Distribution NRC PDR Local PDR Projects Reading ADSP Reading D. Crutchfield B.

D. Liaw S. Black R. Pierson B. Wilson W. S. Little M. Simms Suzanne Black, Assistant Director for Projects TVA Projects Division Office of Nuclear Reactor Regulation T. Daniels G. Gears D. Moran N. Markisohn OGC B. Grimes E. Jordan ACRS{10)

GPA/CA BFN Rdg. File E. Girard T.

Quay

T

/LA NR VA/PM

~

0 NANE:HSimmsg: T s:as DATE

/

89

/

/89 OFFICIAL R C

RD COPY

RPier o

/%J'89 WW

/

/8 T A:AD/P W

~

SBlack

~

~

~

~

~ <<OO W &>>

WW W

/ /89:

5

'N

'I d C

H

'1 II I

II U I

J I

R

Mr. Oliver D. Kingsley, Jr.

w3 CC:

General Counsel Tennessee Valley Authority 400 West Summit Hill Drive Ell B33 Knoxville, Tennessee 37902 Mr. F. L. Moreadith Vice President, Nuclear Engineering Tennessee Val ley Authority 400 West Summit Hill Drive W12 A12 Knoxville, Tennessee 37902 Vice President and Nuclear Technical Director Tennessee Valley Authority 5N 157B Lookout Place Chattanooga, Tennessee 37402-2801 Mr. M. J.

Ray, Acting Director Nuclear Safety and Licensing Tennessee Valley Authority 5N 157B Lookout Place Chattanooga, Tennessee 37402-2801 Mr. 0. J; Zeringue Site Director Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000

Decatur, Alabama 35602 Mr. P. Carier Site Licensing Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000

Decatur, Alabama 35602 Mr. G. Campbell Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. 0.

Box 2000

Decatur, Alabama 35602 Mr. D. L. Williams Tennessee Valley Authority 400 West Summit Hill Drive W10 B85 Knoxville, Tennessee 37902
Chairman, Limestone County Commission P. 0.

Box 188

Athens, Alabama 35611 Claude Earl Fox, M.D.

State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36130 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Atlanta, Georgia 30323 Mr. Danny Carpenter Senior Resident Inspector Browns Ferry Nuclear Plant U.S. Nuclear Regulatory Commission Route 12, Box 637

Athens, Alabama 35611 Dr. Henry Myers, Science Advisor Committee on Interior and Insular Affairs U.S.

House of Representatives Washington, D.C.

20515 Tennessee Valley Authority Rockville Office 11921 Rockville Pike Suite 402 Rockvi 1 le, Maryland 20852