REGUL RY INFORMATION DISTRIBUT1 SYSTEM (RIDS)

'\\

ACCESSION. NBR: 8712300197, DOC. DATE: 86/08/18 NOTARIZED:

NQ DOCKET 0 F*CIL:50-259 Browns Ferry Nuclear Power Stations Unit ii Tennessee 05000259 50-260 Browns Ferry Nuclear Power Stationi Unit 2i Tennessee 05000260 50-296 Browns Ferry Nuclear Power Station>

Unit 3i Tennessee 05000296 AUTH. NAME AUTHOR AFFILIATION LEWIS> R. L.

Tennessee Valley Authority RECIP. NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards "Effluent 5 Waste Disposal Rept Supplemental Info'an June 1986. " Corresponding rept on "Radiological Impact on Man" will be forwarded seperatelg.

DISTRIBUTION CODE:

IE48D COPIES RECEIVED: LTR L

ENCL

)

SIZE TITLE:

50. 36a(a) (2) Semiannual Effluent Release Reports NOTES: G. Zech 3 cg.

1 cg.

ea to: Ebneteri Axelradi S. Richardson B. D. Liaw> K. Barri Donohewi OI.

G. Zech 3 cg.

1 cg.

ea 'to: Ebneteri Axelradi S. Richardsoni B. D. Liawi K. Barri Donohewi OI.

G. Zech 3 cg.

1 cg.

ea to: Ebneteri Axelradi S. Richardsoni B. D. Liawi K. Barri Donohewi OI.

05000259 05000260 05000296 RECIPIENT ID CODE/NAME JAMERSONe C GEARS' INTERNAL:

ACR8 AEOD/DSP/TPAB NRR/DEST/PSB NRR/PMAS/ILRB RGN2 FILE 02 COPIES LTTR ENCL 1

0 1

1 1

1 1

1 1

1 1

REC IP IENT ID CODE/NAME PD STANGi J AEOD/DOA ARM TECH ADV NRR/DREP/RPB 01 R

2/DRSS/EPRPB CQr IES LTTR ENCL 5

5 1

1 1

1 1

1 4

4 1

1 1

EXTERNAL:

BNL TICHLER i J03 NRC PDR NOTES:

1 1

10 10 LPDR 1

1 TOTAL NUMBER QF CQP IES REQUIRED:

LTTR 34 ENCL 33

~

I l'

EFFLUENT AND WASTE DISPOSAL REPORT SUPPLEMENTAL INFORMATION FIRST HALF 1986 I.

Re ulator Limits A.

Fission and Activation Gases:

l.

Instantaneous-Ql

+

0.13 Q2

<1 l.46 Ql

=

release rate from building exhaust vents in Ci/sec.

Q2 release rate from main stack in Ci/sec.

2.

Quarterly < O.lb Ci/sec as average BSC. Iodines and Particulates, half-lives > 8 days l.

Instantaneous-Q3

+

Q4

<1 0.33 44 Q3

=

release rate from building exhaust vents in yCi/sec.

Q4

=

release rate from main stack in yCi/sec.

2.

Quarterly - <0.80 yCi/sec.

as average D.

Liquid Effluent:

1E-07 yCi/ml (ref. 10 CFR 20, Appendix B, note 3C, Table II, column 2).

E.

Tritium 1.

Liquid <3.0E-03 yCi/ml (ref.

10 CFR 20, Table II, column 2) 2.

Airborne - <2.0E-07, yCi/cc (ref.

10 CFR 20, Table I, column 2)

II. Maximum Permissible Concentrations A.

Fission and Activation Gases:

Not applicable B.

Iodines:

Not applicable C.

Particulates, half lives > 8 days:

Not applicable D.

Liquid Effluents:

Sum of individual MPC ratios

<1 (Ref.

10 CFR 20, Appendix B, note 1) 87>asoo>97 86085O PDR ADOCK 0500oa59, R

PDR.

XE-RS hatt

h r=

I 9

L t& ~ i K ~ tl' g

h V

EFFLUENT AND WASTE DISPOSAL REPORT SUPPLEMENTAL INFORHATION FIRST HALF 1986 IV. Heasurements and A

roximations of Total Radioactivit A,BSC.

Fission and Activation Gases,

Iodines, and Particulates:

Airborne effluent gaseous activity is continuously monitored and recorded;,additionally, grab samples are taken and analyzed monthly to determine specific radionuclide activity concentrations.

Stack and building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans.

The flow rate data is consolidated weekly to determine the volume of airborne effluents released from the plant.

Charcoal and particulate samples are taken and analyzed at least weekly to determine specific activity concentrations.

The total activity released from the plant is then calculated by taking weekly airborne effluent volume.

D.

Liquid Effluents Two gamma isotopic activity concentrations are determined on each batch of liquid effluent prior to release.

The total curie content of a released batch is determined by multiplying, the highest activity concentration by the total volume discharged.

The total activity released during a month is then determined by summing the activity content of each batch discharged during the month.

V.

Batch Value Unit First Second quarter guarter A.

Liquid 1.

Number of batches released 2.

Total time period for batch releases 3.

Maximum time period for a batch release I

4.

Average time period for batch releases 5.

Hinimum time period for a batch release 111 102 33373 33175 635 500 300

'361 165 Each Hins Mins Hins Hins 6.

Average stream flow during period of release of effluent into a flowing stream>

B, Gaseous None 1 To be supplied by others.

I I "'I Mff

Mw"

'f M

f Cy

EFFLUENT AND MASTE DISPOSAL REPORT FIRST HALF 1986 LIQUID EFFLUENTS SUHHATION OF ALL RELEASES Unit guarter quarter

'L Eaten A.

Fission and Activation Products 1.

Total Releasesl Curies 1.59E-Ol 1.53E-Ol

+1.50E+01 2.

3.

Average Diluted Conc.

During Period Percent of Applicable Limit (20 Ci/quarter) yCi/ml 2.49E-09 2.89E-09 7.95E-01 7.65E-Ol B.

Tritium 1.

Total Releases Curies 2.46E+00 2.03E+00

+5.0

+00 2.

Average Diluted Conc.

During Period 3.

Percent of Applicable Limit (3E-03 yCi/ml)

C.

Dissolved and Entrained Noble Gases2 1.

Total Releases yCi/ml 4.56E-08 3.84E-08 1.52E-03 1.28E-03 Curies 3.11E-05

<5. 31E-03 +2. 80Ei00 2.

Average Diluted Conc.

During Period 3.

Percent of Applicable Limit (6E-06 yCi/ml)

D.

Gross Alpha Radioactivity 1.

Total Releases yCi/ml 5.76E-13

<1.00E-10 9.60E-06

<1.67E-03 Curies

<7.92E-04 2.26E-04

+1.70E+Ol 2.

Average Diluted Conc.

During Period E.

Volume of Maste Release (Before dilution) pCi/ml

<1. 47E-ll

4. 27E-12 Liters 1.17E+07 1.11E>07

+5.00E+00 F.

Volume of Dilution Mater for Period Liters 5.40E+10 5.29E+10

+1.00E+Ol G.

Total CCM flow for Six Honths 135 gigagallons 1 Based on pre-release analyses which are not decay corrected.

2 Includes Xe-133, Xe-135, and others.

EFFLUENT AND WASTE DISPOSAL REPORT LIQUID RELEASES FOR FIRST HALF 1986 BATCH MODE

~Zsoto e

{Reguired by REG Guide 1.21) l.

Cr-51 2.

Mn-54 3.

Co-58 4.

Fe-59 5.

Co-60 6.

Zn-65 7.

Nb-95 8.

Zr-95 9.

Mo-Tc-99m 10.

I-131 ll.

Xe-133 12.

Cs-134 13.

XQ-135 14.

Cs-137 15.

Ba-140 16.

La-140 17.

Ce-141 18.

Sr-89 19.

Sr-90 First uarter Unit Curies 2.42E-04 2.83E-04

<2.02E-03

<2.39E-03 1.24E-02 2.97E-02

<1.88E-03

<3.11E-03 6.00E-06

<2.33E-03

<4.22E-03 4.59E-02 3.11E-05 6.96E-02 2.76E-05

<5.52E-04 3.81E-06 1.09E-04

<8.57E-05 Second uarter Unit Curies 1.05E-04 5.70E-04

<2.05E-03

<3.39E-03 1.76E-02 3.81E-02

<1.78E-03

<3.10E-03

<9.92E-04 3.04E-05

<4.11E-03 2.96E-02

<1.20E-03 6.65E-02

<8.18E-03

<5.55E-04 1.24E-05

<8.54E-04

~

<2.18E-04

4

EFFLUENT AND HASTE DISPOSAL REPORT LIQUID RELEASES FOR FIRST HALF 1986 BATCH MODE

~Ieoto e

Others (Not Required by REG Guide 1.21) 1.

Mn-56" 2.

As-76<

3.

I-133%

4.

Ag-110m 5.

Sb-125 6.

Sb-124 7.

Ru-103 8.

Ce-144 9.

Co-57 First uarter Unit Curies 4.17E-OS 7.83E-OS 1.63E-05 2.94E-04 5.31E-OS 8.75E-OS 1.82E-05 4.03E-05

~ 2.46E-06

(

Second uarter Unit Curies 1.21E-04 2;llE-04

~ These radionuclides with short half lives were erroneously reported in BFN Monthly Operating, Reports and were not actually released.

This section was prepared principally by S.

B. Jordan.

I h I

EFFLUENT AND WASTE DISPOSAL REPORT FIRST HALF 1986 GASEOUS EFFLUENTS SUMMATION OF ALL RELEASES Summation of All Releases Unit First Second guarter guarter t 'Error A.

Fission and Activation Gases 1.

Total Releases 2.

Avg. Release Rate for Period 3.

Percent of T.S. Limit Ci

<6.42E+02

<5.23E+02

+7.60E+00 yCi/sec

<8.17E+01

<6.65E+Ol 0.00'.00 B.

Iodines 1.

Total Iodine-131 2.

Avg. Release Rate for Period 3.

Percent of T.S. Limit 0.00 2.07E-03 Ci

<1.90E-04 6.50E-05

+1.22E+01 yCi/sec

<2.42E-OS 8.27E-06 C.

Particulates 1.

Particulates with half-lives

,>8 days 2.

Avg. release rate for period Ci 6.98E-04 7.81E>>05

+1.05E+Ol pCi/sec 8.88E-05 9.94E-06 3.

Percent of T.S. Limit 4.

Gross alpha radioactivity D.

Tritium ci 2.22E-02 2.48E-03

<1.19E-06 7.48E-07 1.

Total release 2.

Avg. release rate for period 3.

Percent of T.S. Limit 4.

Ground level release 5.

Elevated release Ci 5.73E-Ol 9.71E-Ol

+3.00E+00 Ci Ci 1.65E-03 1.68E-03 5.72E-01

.9.71E-01 8.7SE-04

<2.71E-02 yCi/sec 7.29E-02 1.24E-01

l. Reporting period - 182 days..'

h

EFFLUENT AND WASTE DISPOSAL REPORT

, FIRST HALF 1986 GASEOUS EFFLUENTS ELEVATED RELEASE 1.

Fission Gases Krypton-85 Krypton-85m Krypton-87 Krypton-88 Xenon-133 Xenon-135 Xenon-135m Xenon-138 Total for Period Unit Ci Ci Ci Ci Ci ci Ci Ci First Second quarter quarter

<4.10E+02

<3.13E+02

<1.12E+00

<5.04E-Ol

<4.11E+00

<1.71E+00

<3.88E+00

<3.83E+00

<2.50E+00

<1.84E+00

<7.60E-01

<8.56E-01

<3.50E+00

<2.77E>00

<7.92E+00

<8.20E+00

<4.34E+02

<3.33E>02 2.

Iodines Iodine-131 Iodine-133 Iodine-135 Total for Period Ci Ci Ci Ci

<1.50E-05 3.86E-05

<2.51E-05

<2.23E-04

<1.37E-03

<4.78E-04

<1.41E-03 3.86E-05

EFFLUENT AND WASTE DISPOSAL REPORT FIRST HALF 1986 GASEOUS EFFLUENTS ELEVATED RELEASE (Continued) 3.

Particulates Unit First Second guar'ter quarter Sr-901 Cs-134 Cs-137 Ba-140 La-140 Sb-125 Ce-144 Ru-103 4.

Tritium Total for Period ci Ci Ci Ci Ci Ci Ci ci Ci ci Ci 4.788-07

<4.398-07 7.938-07

<1.61E-07

<1.728-05

<1.90E-05

<1.49E-05 1.76E-06

<5.60E-05

<5.928-04

<1. 64E-05

<3. 608-95 4.868-05 2.158-05 2.07E-05 8.638-07

7. 148-05
2. 33E-05
8. 758-04

<2. 71E-02 1 Predicted estimation of releases.

EFFLUENT AND WASTE DISPOSAL REPORT FIRST HALF 1986 GASEOUS EFFLUENTS GROUND LEVEL RELEASE 1.

Fission Gases Krypton-85 Krypton-85m Krypton-87 Krypton-88 Xenon-133 Xenon-135 Xenon-135m Xenon-138 Total for Period Unit Ci Ci Ci Ci Ci Ci ci First Second guaeter quarter

<1.83E+02

<1.77E+02

<1.26E+00

<7.14E-01

<2.77E+00

<1.53E+00

<3.89E+00

<2.35E+00

<3.20E+00

<1.64K+00

<9.76E-01

<5.64E-01

<4.08E+00

<1.92E+00

<9.07E+00

<4.48E+00

<2.08E+02

<1.90E+02 2.

Iodines Iodine-131 Iodine-133 Iodine-135 Total for Period Ci ci Ci Ci

<1.75E-04 2.64E-05

<4.45E-04

<4.69E-01

<1.08E-02

<3.01E-02

<1.14E-02 2.64E-05

EFFLUENT AND MASTE DISPOSAL REPORT FIRST HALF 1986 GASEOVS EFFLVENTS GROVND LEVEL RELEASE (Continued) 3.

Particulates Sr-901 Cs-134 Cs-137 Ba-140 La-140 Cr-51 Co-60 Zn-65 Sb-124 4.

Tritium Total for Period Unit Ci Ci Ci Ci Ci Ci Ci Ci Ci'i ci First Second guarter guarter 6.198-06

<1.56E-05 7.078-07

<2.708-06 7.15E-05

<4.1SE-04 1.03E-04 3.15E-OS

<S.OSE-04

<3.26E-03

<3.04E-04

<1.15E-03 2.78E-04 2.81E-OS 6.388-05 2.338-05 7,55E=OS 6.278-04 5.48E-OS 5.728-01 9.718-01 1 Predicted estimation of releases.

.,II'

~

~ II

EFFLUENT AND WASTE DISPOSAL REPORT FIRST HALF 1986 SOLID WASTE AND IRRADIATED FUEL SHIPHENTS A.

Solid Waste Shipped Offsite for burial or disposal

{not irradiated fuel)

First Unit Half Error a.

Spent resins, filter sludges, evaporator bottoms, etc.

m3ci b.

Dry compressible

waste,

{Drums) m3 contaminated eguip., etc.

Ci c.

Irradiated components, m3 control rods, etc, Ci 8.75E+Ol 2.38E+02 1.50E+Ol 1.69E+02 3.52E+00 1.50E>01 N/A d.

Non-compressible waste m3 2.88E+02 Scrap metal, scrap wood, etc.

Ci 1.27E+Ol 1.50E>01 2.

Estimate of major nuclide compositions

{by type of waste) a.

Spent Resins, Filter Sludges, Evaporator Bottoms, etc.

First Half 1.

Zinc-65 2.

Cesium-137 3.

Cesium-134 4.

Chromium-51 5.

Cobalt-60 6.

Lanthanum-140 7.

Barium-140 8.

Iodine-131 9.

Hanganese-54 10.

Silver-110m 11.

Iron-55 12.

Other Nuclides Unit Unit 5.27Et01 Ci 1.92Et01 Ci 1.21E+Ol Ci O.OOEOOO Ci 1.09E001 Ci O.OOE+00 Ci O.OOEt00 Ci O.OOE+00 Ci 1.06E-01 Ci O.OOE+00 Ci 3.78E+00 Ci 1.21E+00 Ci 1.25Et02 4.57E+Ol 2.87E+01 O.OOE+00 2.59Et01 O.OOEt00 O.OOE+00 O.OOE+00 2.52E-Ol O.OOE+00 8.99E+00 2.88E+00

c,v t

EFFLUENT AND MASTE DISPOSAL REPORT SECOND HALF 1985 SOLID HASTE AND IRRADIATED FUEL SHIPHENTS 2.

Estimate of major nuclide compositions (by type of waste)

(Continued) b.

Dry Compressible

Waste, Contaminated Equipment, etc.

1.

Zinc-65 2.

Cesium-137 3.

Cesium-134 4.

Chromium-51 S.

Cobalt-60 6.

Iron-55 7.

Iron-59 8.

Iodine-131 9.

Hanganese-54 10.

Silver-llOm ll.

Niobium-95 12.

Other Nuclides 7.19E+00 7.19E+00 1.21E%01 1.88E+Ol 2.57E+01 1.34E+00 Ci 2.53E-01 Ci 2.53E-01 Ci 4.25E-01 Ci 6.60E-01 Ci 9.05E-01 Ci 4.71E-02 O.OOEEOO Ci O.OOE+00 4.43E+00 1.33E+00 2.31EEOO 2.13E-01 Ci

,'.56E-Ol Ci 4.66E-02 Ci 8.13E-02 Ci 7.50E-03 First Half Unit Unit

'L 1.94Et01 Ci 6.82E-Ol c.

Irradiated Components, Control Rods, etc.

None

fl

~

asNIC<" "'lftlw

EFFLUENT AND MASTE DISPOSAL REPORT FIRST HALF 1986 SOLID WASTE AND IRRADIATED FUEL SHIPHENTS 2.

Estimate of major nuclide compositions (by type of waste)

(Continued) d ~

Unit 7

1.

. Zinc-65 2.

Cesium-137 3.

Cesium-134 4.

Chromium-51 5.

Cobalt-60 6.

Iron-55 7.

Iron-59 8.

Iodine-131 9.

Hanganese-54 10.

Silver-110m ll.

Niobium-95 12.

Other Nuclides 7.19E+00 Ci 7.19E+00 1.21E+Ol 1.88E+Ol 2.57E+Ol Ci Ci Ci ci 1.34E+00 Ci O.OOE+00 Ci 4.43E+00 Ci 1.33E+00 Ci 2.08E+00 Ci 4.59E-Ol Ci Non-compressible

Waste, Scram He>al, Scrap Mood, etc.

First HalfUnit 1.94E+Ol Ci 2.47Et00 9.11E-01 9.11E-01 1.53E-01 2.38E+00 3.26E+00 1.69E-01 O.OOE+00 5.61E-01 1.68E-01 2.63E-01 5.81E-02 3.

Solid Maste Disposition Number of Shi ments 32 1

Hode of Trans ortation Destination Sole Use Truck

Barnwell, SC Sole Use Truck
Richland, MA 4.

Irradiated Fuel Disposition Number of Shi ments None Hode of Trans ortation N/A Destination N/A This section was prepared principally by R.

D. Hosley.

P

~

~'~" ~

C4~il%-

~

l

~

r.

TENNESSEE VALLEY ALJTHORITY Browns Ferry Nuclear Plant Post Office Box 2000

Decatur, Alabama 35602 AUG 18 1986 Re ional Administrat

, Offi f Inspection a

Enforcemen Nu ear Regulat y Commission 101 Harietta rect Sui 3100 Atlant

, Georgia 30303

Dear Sir:

I As required by Regulatory Guide 1.21, Revision 1, we are submitting the enclosed report of radioactive discharges released from Browns Ferry during the period of January 1, 1986, through June 30, 1986.

The corresponding report on the "Radiological Impact on Han" will be forwarded separately by TVA's Radiological Hygiene Branch.

Very truly yours, TENNESSEE VALLEY AUTHORITY Original Signed By Robert L. Lewis, Robert L. Lewis Plant Hanager Enclosure cc: Milliam J. Taylor U.S. Environmental Protection Agency Facilities Performance Branch Mater Hanagement Division 345 Courtland Street Atlanta, Georgia 30308 James M. Marr Alabama Mater Improvement Commission State Office Building Hontgomery, Alabama 36130 Document Control Desk

.S. Nuclear Regulatory Commission Mashington, D.C.

20555 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Mashington, D.C.

20555 (2)

Ao F.

((at Qniinrtuo.tv Emolover

~

~

e~

~ ~~

ai