Forwards Evaluation & Request for Addl Info Re Util 840702 Response to Generic Ltr 84-09 on Technical Criteria by Which Mark I BWR Plant Could Be Found Not to Rely on Purge/ Repressurization Sys as Primary Measure of Hydrogen Control
ML18031A761
Person / Time
Site: Browns Ferry  
Issue date: 09/09/1986
From: Grotenhuis M
Office of Nuclear Reactor Regulation
To: White S
TENNESSEE VALLEY AUTHORITY
Shared Package
ML18031A762 List:
References
GL-84-09, GL-84-9, TAC-55953, TAC-55954, TAC-55955, TAC-R00098, TAC-R00099, TAC-R00100, TAC-R100, TAC-R98, TAC-R99, NUDOCS 8609150073
Download: ML18031A761 (4)


Text

Docket No. 50-259/260/296 Mr. S. A. White Manager of Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Mr. White:

SUBJECT:

HYDROGEN RECOMBINER CAPABILITY Re:

Browns Ferry Nuclear Plant, Units 1, 2 and 3

By letter dated July 2, 1984, as supplemented May 13,

1986, TVA responded to Generic Letter 84-09 dated May 8, 1984.

The Generic, Letter provided certain technical criteria by which a Mark I BWR plant co'uld be found not to rely on purge/repressurization systems as the primary measures of hydrogen control.

We have completed our review, copy enclosed, of the TVA submittals, and conclude that TVA will have demonstrated compliance with the guidance to remove al1 potential oxygen sources,

when, aS discussed with your staff, appropriate Technical Specifications, as described in the enclosed Request for Additional Information are proposed.

Please respond to the enclosed request for additional information within 60 days of the date of this request, or provide a schedule for your response.

6 The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, Original signed bp Marshall Grotenhuis, Project Manager BWR Project Directorate Imt2 Division of BWR Licensing

Enclosures:

l.

Evaluation 2.

Request for Additional Information cc w/enclosures:

See next page L

IA0 O'NA, OOD O'O OO

+IA IO HM OCI OA IA%

Oo'A KIQ.L, DISTRIBUTION:

l ~F1 NRC PDR Local PDR PD82 File LSpessard, DI HDenton

CStahle, NRR DBL:PD82 SNor 's:rs f/ P/86 RBerriero
BHayes, OI OGC - Bethesda NThompson

'Jordan HThompson SNorris/GLainas BGrimes SRConnelly, OIA MGrotenhuis J Parti ow BJYoungbl ood RCl ark/AToal ston

GZech, RI I JTayl or, IE
SPWeise, RII
WLong, NRR NGrace, RII SRichardson, IE ACRS (10)

FCantrell, RII

TKenyon, NRR JHolonich, NRR TAlexion, NRR DBL:PD DBL:PDImI DBL:PD82 RClar MGrotenhui s DMul 1 er 8/g/86 fldj /86

/f/8/ /86

~ I Jt

('I Ill,l, U

fl Eg

Nr. S.

A. White Tennessee Valley Authority Browns Ferry Nuclear Plant Units 1, 2, and 3

CC:

H. S. Sanger,'r.,

Esquire General Counml Tennessee Valley Authority 400 Commerce Avenue E 11B 330 Knoxville, Tennessee 37902 Nr.

Ron Rogers Tennessee Valley Authority 5N 130B Lookout Place Chattanooga, Tennessee 37402-2801

Chairman, Limestone County Commission Post Office Box 188
Athens, Alabama 35611 Ira L. Neyers, N.D.

State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36130 Nr. K. W. Mhitt E3A8 400 West Summit Hill Drive Tennessee Valley Authority Knoxville, Tennessee 37902 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Narietta Street, Suite 3100 Atlanta, Georgia 30303 Nr. Steven Roessler U. S. Nuclear Regulatory Commission Reactor Training Center Osborne Office Center, Suite 200 Chattanooga, Tennessee 37411 Site Director, BFNP Tennessee Valley Authority Post Office Box 2000

Decatur, Alabama 35602 Resident Inspector U. S. huclear Regulatory Commission Route 2, Box 311
Athens, Alabama 35611 Nr. Donald L. Williams, Jr.

Tennessee Valley Authority 400 West Summit Hill Drive, W10B85 Knoxville, Tennessee 37902 Nr. Robert L. Lewis, Nanager, BFHP Tennessee Valley Authority Post Office Box 2000

Decatur, Alabama 35602