PRELIHINRY DATA SHEET FOR, NUREGAT57 S/RV TEST WYLE LABS'UNTSVILLE'LAs DATE TESTED 3-24-81 S/RV MODEL NO S/Ry SERIAL NP N63580-00-0019 RUN/TEST NO.
403 S/RV MANUFACTURER CROSBY 6R10 TYPE OF TEST WATER 15 F SUBCOOLED LOADS I
SUPPORTS TEST RESULTS S/RV OPENED ON COMMAND S/RV CLOSED ON COMMAND S/RV FLUID TEST CONDITIONS FLUID TEMPERATURE INLET PRESSURE S/RV FLOW RATE S/RV OPENING TIME (MAIN DISK LIFT TIME)
YES YES 206~ F 262 PSIG LATER VALVE INTEGRITY DEMONSTRATED BY:
VISUAL INSPECTION POST-TEST HYDRO.+
POST-TEST DISASSEMBLY INSPECTION FACILITY INTEGRITY DEMONSTRATED YES N/A N/A YES
+ ONLY ONCE PER VALVE AT END OF TEST SEQUENCE
" NOT APPLICABLE