ML18025B924

From kanterella
Jump to navigation Jump to search
Summary of Comments on 2018-01-24 by Ken Scarola_Nuclear Automation Engineering
ML18025B924
Person / Time
Issue date: 01/24/2018
From:
Office of Nuclear Reactor Regulation
To:
References
RIS-02-022, S01 DRF
Download: ML18025B924 (72)


See also: RIS 2002-22

Text

The following document is a preliminary draft being made

publically available to support a Category 3 public meeting

on January 26, 2018. NRC staff review of this draft document

has not been completed.

NRC DRAFT REGULATORY ISSUE SUMMARY 2002-22,

SUPPLEMENT 1

CLARIFICATION ON ENDORSEMENT OF NUCLEAR ENERGY

INSTITUTE GUIDANCE IN DESIGNING DIGITAL UPGRADES

IN INSTRUMENTATION AND CONTROL SYSTEMS

Summary of Comments on 2018-01-23 Draft RIS_KS.pdf

This page contains no comments

RIS 2002-22 Supplement 1

Page 2 of 8

UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

OFFICE OF NEW REACTORS

WASHINGTON, D.C. 20555-0001

January XX, 2018

NRC REGULATORY ISSUE SUMMARY 2002-22, SUPPLEMENT 1

CLARIFICATION ON ENDORSEMENT OF NUCLEAR ENERGY INSTITUTE GUIDANCE IN

DESIGNING DIGITAL UPGRADES IN INSTRUMENTATION AND CONTROL SYSTEMS

ADDRESSEES

All holders and applicants for power reactor operating licenses or construction permits under

Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of

Production and Utilization Facilities.

All holders of and applicants for a combined license, standard design approval, or

manufacturing license under 10 CFR Part 52, Licenses, Certifications, and Approvals for

Nuclear Power Plants. All applicants for a standard design certification, including such

applicants after initial issuance of a design certification rule.

All holders of, and applicants for, a construction permit or an operating license for non-power

production or utilization facilities under 10 CFR Part 50, including all existing non-power reactors

and proposed facilities for the production of medical radioisotopes, such as molybdenum-99,

except those that have permanently ceased operations and have returned all of their fuel to the

U.S. Department of Energy.

INTENT

The U.S. Nuclear Regulatory Commission (NRC) is issuing a supplement to Regulatory Issue

Summary (RIS) 2002-22, dated November 25, 2002 (Agencywide Documents Access and

Management System (ADAMS) Accession No. ML023160044). In RIS 2002-22, the NRC staff

endorsed Guideline on Licensing Digital Upgrades: EPRI TR-102348, Revision 1, NEI 01-01: A

Revision of EPRI TR-102348 to Reflect Changes to the 10 CFR 50.59 Rule, (Nuclear Energy

Institute (NEI) hereinafter NEI 01-01) (ADAMS Accession No. ML020860169). NEI 01-01

provides guidance for designing, licensing, and implementing digital upgrades and

replacements to instrumentation and control (I&C) systems (hereinafter digital I&C) in a

consistent and comprehensive manner. The purpose of this RIS Supplement is to clarify RIS

2002-22, which remains in effect. The NRC continues to endorse NEI 01-01 as stated in RIS

2002-22, as clarified by this RIS Supplement. This RIS Supplement clarifies the guidance for

preparing and documenting qualitative assessments that licensees can use to develop written

evaluations to address the criteria in 10 CFR 50.59, Changes, tests and experiments. This

RIS Supplement is intended to reduce regulatory uncertainty for licensees applying the

10 CFR 50.59 process and making digital I&C modifications without prior NRC approval. This

RIS Supplement is not directed toward digital I&C upgrades and replacements of reactor

This page contains no comments

RIS 2002-22 Supplement 1

Page 3 of 8

protection systems and engineered safety features actuation systems (ESFAS), since

application of the guidance in this RIS Supplement to such changes would likely involve

additional considerations. This RIS Supplement is also not intended to provide new design

process guidance for addressing software common cause failure (software CCF) or methods for

addressing common cause failure of the reactor protection systems and engineered safety

features actuation systems. Specific guidance for addressing potential common cause failure of

digital I&C equipment when making design changes to structures, systems, and components

(SSCs) is contained in other NRC guidance documents and NRC-endorsed industry guidance

documents.

This RIS Supplement requires no action or written response on the part of an addressee.

BACKGROUND INFORMATION

By letter dated March 15, 2002, NEI submitted EPRI TR-102348, Revision 1 (NEI 01-01) for

NRC staff review. NEI 01-01 replaced the original version of EPRI TR-102348, dated

December 1993, which the NRC endorsed in Generic Letter 1995-02, Use of NUMARC/EPRI

Report TR-102348, Guideline on Licensing Digital Upgrades, in Determining the Acceptability

of Performing Analog-to-Digital Replacements Under 10 CFR 50.59, dated April 26, 1995

(ADAMS Accession No. ML031070081). In 2002, the NRC staff issued RIS 2002-22 to notify

addressees that the NRC staff had reviewed NEI 01-01 and was endorsing the report for use as

guidance in designing and implementing digital upgrades to nuclear power plant instrumentation

and control systems.

Following the NRC staffs 2002 endorsement of NEI 01-01, holders of construction permits and

operating licenses have used this guidance in support of digital design modifications in

conjunction with Regulatory Guide 1.187, Guidance for Implementation of 10 CFR 50.59,

Changes, Tests, and Experiments, dated November 2000 (ADAMS Accession

No. ML003759710), which endorsed NEI 96-07, Guidelines for 10 CFR 50.59 Implementation,

Revision 1, dated November 2000 (ADAMS Accession No. ML003771157).

The regulations in 10 CFR 50.59(d)(1) state: The licensee shall maintain records of changes in

the facility, of changes in procedures, and of tests and experiments made pursuant to paragraph

(c) of this section. These records must include a written evaluation which provides the bases for

the determination that the change, test, or experiment does not require a license amendment

pursuant to paragraph (c)(2) of this section.

The NRC inspections of documentation for digital I&C plant modifications prepared by some

licensees using the guidance in NEI 01-01 uncovered inconsistencies in the performance and

documentation of engineering evaluations of digital I&C modifications and inadequacies in the

documentation of the technical bases supporting responses to the 10 CFR 50.59(c)(2)

evaluation criteria. This RIS Supplement clarifies the RIS 2002-22 endorsement of the

NEI 01-01 guidance by providing additional guidance for developing and documenting

qualitative assessments adequate for use as bases for licensee evaluations addressing the

criteria of 10 CFR 50.59(c)(2). In particular, this RIS Supplement clarifies the guidance for

documenting licensee determinations that a digital modification will exhibit a sufficiently low"1

1 NEI 01-01, Page 4-20, defines sufficiently low to mean much lower than the likelihood of failures that are

considered in the UFSAR (e.g., single failures) and comparable to other common cause failures that are not

considered in the UFSAR (e.g., design flaws, maintenance errors, calibration errors).

1

2

3

4

Page: 3

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 12:06:34 PM

In the sentence directly before this one, the limitation regarding not providing new guidance is restricted to RPS and ESF. But in this sentence that limitation is

extended to all SSCs. This contradicts subsequent sections of this RIS which provide new CCF guidance for other non-RPS/ESF SSCs.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/23/2018 10:39:52 PM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 9:03:14 AM

ATWS is considered in most FSARs, maybe all. So CCF due to a design flaw is considered in most, maybe all, FSARs.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:02:09 AM

RIS 2002-22 Supplement 1

Page 4 of 8

likelihood of failure. This determination then serves as a technical basis supporting the

conclusions that are reached when a licensee evaluates a proposed design against the criteria

of 10 CFR 50.59(c)(2) to determine whether prior NRC staff approval is needed before the

proposed design can be implemented.

In response to staff requirements memorandum (SRM)-SECY-16-0070 Integrated Strategy to

Modernize the Nuclear Regulatory Commissions Digital Instrumentation and Control Regulatory

Infrastructure (ADAMS Accession No. ML16299A157), NRC staff has engaged NEI and

industry representatives to improve the guidance for applying 10 CFR 50.59 to digital

I&C-related design modifications as part of a broader effort to modernize I&C regulatory

infrastructure. The NRC staffs plan for accomplishing this update is outlined in the NRCs

Integrated Action Plan to Modernize Digital Instrumentation and Controls Regulatory

Infrastructure (ADAMS Accession No. ML17102B307). This plan, which is updated

semiannually, provides a comprehensive view of NRC activities associated with improvements

to the digital I&C regulatory infrastructure, including a planned schedule for completion of key

regulatory infrastructure documents. In Section 5 of the NRC staffs Integrated Action Plan

(IAP), the NRC staff outlines how it plans to clarify its previous endorsement of the NEI 01-01

guidance by providing additional guidance for developing and documenting acceptable

qualitative assessments in support of the performance of 10 CFR 50.59 evaluations of proposed

digital I&C modifications. Making available the guidance in this RIS Supplement is described as

a near-term action in the IAP to provide specific guidance for documenting qualitative

assessments that a proposed digital I&C modification will exhibit a sufficiently low likelihood of

failure. The use of appropriately-prepared qualitative assessments is one acceptable way to

document the evaluation of whether a design change can result in more than a minimal increase

in the frequency of an accident or the likelihood of occurrence of a malfunction of an SSC

important to safety previously evaluated in the final safety analysis report. The use of

appropriately-prepared qualitative assessments is also one acceptable way to document the

evaluation of whether a design change can result in accidents of a different type or malfunctions

of SSCs with different results than previously evaluated. The assessment of such malfunctions

includes the need to address the potential for common cause failures, (which is within the scope

of the IAP), when proposing changes to SSCs that are of lesser importance to safety than that

of reactor protection systems and Engineered Safety Features Actuation Systems. The IAP

also describes a longer-term plan for incorporating the guidance of this RIS Supplement into

durable guidance documents that are now under development. The NRC staff will continue to

engage with stakeholders on the development of new guidance to address the identified issues

and needs.

Applicability to Non-Power Reactor Licensees

The examples and specific discussion in this RIS Supplement and other guidance referenced by

this RIS Supplement (i.e., NEI 01-01 and original RIS 2002-22) primarily focus on power

reactors. Nonetheless, licensees of non-power production or utilization facilities (NPUFs) may

also use the guidance in RIS 2002-22 and apply the guidance in this RIS Supplement to

develop written evaluations to address the criteria in 10 CFR 50.59(c)(2). In particular, NPUF

licensees may use the guidance to prepare qualitative assessments that consider design

attributes, quality measures, and applicable operating experience to evaluate proposed digital

I&C changes to their facilities as described in Sections 4, 5, and Appendix A of NEI 01-01.

However, certain aspects of the guidance that discuss the relationship of regulatory

requirements to 10 CFR 50.59 may not be fully applicable to NPUFs (e.g., 10 CFR Part 50,

Appendix A and B are not applicable to NPUFs).

1

2

Page: 4

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 12:07:45 PM

The first paragraph on Page 3 says this RIS is not applicable to RPS/ESF. But this paragraph implies it would not be applicable to any equipment of equal or

greater importance to RPS/ESF. Importance can be determined by the PRA. Equipment of equal or greater importance would typically include load sequencers,

and accident monitoring instrumentation and controls for manual actions credited in the TAA. So the original statement that says this RIS is not applicable to

RPS and ESFAS should be expanded to encompass these additional systems.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:06:19 AM

RIS 2002-22 Supplement 1

Page 5 of 8

SUMMARY OF ISSUE

Section 3.2.3 of the NRC staffs evaluation of NEI 01-01 (Attachment 1 to RIS 2002-22) states:

The staffs position regarding documentation of 10 CFR 50.59 evaluations is

accurately reflected in the second paragraph in Appendix A to the submittal,

which states: The 10 CFR 50.59 questions should be answered in sufficient

detail, either by reference to a source document or by direct statements, that an

independent third party can verify the judgements. The staff has reviewed

Appendix A, Supplemental Questions for Addressing 10 CFR 50.59 Evaluation

Criteria, and Appendix B, Outline for Documenting 10 CFR 50.59 Screens and

Evaluations, and, based on the foregoing, concludes that the guidance therein is

acceptable for licensees to use in performing and documenting their

10 CFR 50.59 evaluations.

This RIS Supplement emphasizes the staffs paragraph above.

Specifically, this RIS Supplement provides additional guidance on what is needed to ensure that

licensees adequately perform and document qualitative assessments used to provide an

adequate basis for a determination that a digital modification will exhibit a sufficiently low

likelihood of failure, which is a key element in 10 CFR 50.59 evaluations of whether a change

requires prior NRC approval. Digital hardware being introduced in a nuclear facility modification

is typically expected to be more dependable than the equipment it is replacing. However, there

are no established consensus methods for accurately quantifying the reliability of software. NEI

96-07 Revision 1, Section 4.2.1 states: If a change has both positive and adverse effects, the

change should be screened in. The 10 CFR 50.59 evaluation should focus on the adverse

effects.

In general, digital I&C modifications may include a potential for an increase in the likelihood of

equipment failures occurring within modified SSCs, including common cause failures, that can

lead to the failure to perform a design function. In particular, digital I&C modifications that

introduce or modify identical software within independent trains, divisions, or channels within a

system, and those that introduce new shared resources, hardware, or software among multiple

non-safety related control functions (e.g., controllers, communication networks or video display

units), may include such a potential. The qualitative assessment can be used to support a

conclusion that there is not more than a minimal increase in the frequency of occurrence of

accidents or in the likelihood of occurrence of malfunctions [10 CFR 50.59(c)(2)(i) and (ii)]. The

qualitative assessment can also be used to support a conclusion that the proposed modification

does not create the possibility of an accident of a different type or malfunction with a different

result than previously evaluated in the UFSAR [10 CFR 50.59(c)(2)(v) and (vi)]. NEI 01-01

describes that for 10 CFR 50.59 evaluations, the likelihood of failure is normally demonstrated

qualitatively (i.e., through reference to reasonable engineering practices and engineering

judgment), particularly for systems or components that rely on software, because there are no

well-established, accepted quantitative methods to demonstrate the likelihood of failure from

sources such as software design errors.

For digital I&C modifications, an adequate basis for a determination that a change involves a

sufficiently low likelihood of failure may be derived from a qualitative assessment of factors

involving system design features, the quality of the design processes employed, and an

1

2

3

4

Page: 5

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 12:08:20 PM

We typically view "failure to perform" as "no function at all". But equally important is performing a design function erroneously. This is too often forgotten by

digital designers. It should be clearly stated.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:15:39 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 9:17:29 AM

A failure of shared resources among safety control functions can also introduce unanalyzed malfunctions.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:13:15 AM

RIS 2002-22 Supplement 1

Page 6 of 8

evaluation of relevant operating experience of the software and hardware used (i.e., product

maturity and in-service experience). A licensee may use a qualitative assessment to record the

factors and rationale for concluding that there is an adequate basis for determining that a digital

I&C modification will exhibit a sufficiently low likelihood of failure. In doing so, a licensee may

consider the aggregate of these factors. The attachment to this RIS Supplement, Qualitative

Assessment Framework, provides guidance for performing and documenting this qualitative

assessment.

This RIS Supplement does not change the NRC staff positions in RIS 2002-22 endorsing NEI

01-01. Specifically, RIS 2002-22 states:

Because there is currently no acceptable way to quantitatively establish the

reliability of digital systems, [NEI 01-01] gives considerable attention to the

qualitative assessment of the dependability of and risk associated with I&C

systems. The guidance in the submittal [NEI 01-01] identifies qualitative

approaches within existing endorsed guidance with regard to software issues,

including software-related common-cause failure issues, without proposing

alternatives to the existing guidance. Therefore, the guidance in [NEI 01-01]

does not propose to alter, or offer less conservative guidance for, the existing

licensing process for license amendment requests to implement digital

replacements.

There is no change in NRC staff position regarding its endorsement of the guidance in NEI

01-01 for addressing digital I&C modifications under the 10 CFR 50.59 process. However, this

RIS Supplement clarifies the staffs previous endorsement in RIS 2002-22 of the guidance in

NEI 01-01 pertaining to the performance and documentation of adequate technical evaluations

and adequately documented qualitative assessments to meet the requirements of

10 CFR 50.59. Specifically, the guidance in this RIS Supplement clarifies the NRC staffs

endorsement of the guidance pertaining to Sections 4, 5, and Appendices A and B of NEI 01-01.

The attachment to this RIS Supplement provides a framework for preparing and documenting

qualitative assessments considered acceptable to serve as a technical basis supporting the

responses to key 10 CFR 50.59(c)(2) evaluations.

Clarification of Guidance for Addressing Digital I&C Changes under 10 CFR 50.59

NEI 01-01 supports the use of qualitative assessments, engineering judgment, and industry

precedent when addressing whether frequency of occurrence of an accident or the likelihood of

occurrence of a malfunction of an SSC important to safety would be more than minimally

increased (evaluation criteria 10 CFR 50.59(c)(2)(i) and (ii)). NEI 01-01 also supports the use of

such qualitative assessments when addressing whether a possibility for an accident of a

different type or a malfunction of an SSC important to safety with a different result than any

previously evaluated in the UFSAR would be created (evaluation criteria 10 CFR 50.59(c)(2)(v)

and (vi)). This RIS Supplement describes the importance of documenting how the

implementation of key design attributes, quality of the design processes, and an evaluation of

relevant operating experience is being credited as the basis for making engineering judgments

that the likelihood of failures of SSCs that are introduced by a proposed digital modification is

low. Such qualitative assessments are used to provide an adequate basis for determining that

the likelihood of failure for proposed modifications is low. The guidance in NEI 01-01 provides a

road map to relevant standards and other sources of detailed guidance. The attachment to

this RIS Supplement clarifies how the aggregate of the proposed digital I&C system design

1

2

Page: 6

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:01:37 AM

SECY 93-087 and BTP 7-19 constitute current NRC policy on digital CCF. The current policy does not allow a conclusion that the likelihood of a CCF is

sufficiently low to require no further consideration based on these qualitative factors alone. The current policy is clear that these qualitative factors facilitate a

conclusion that the CCF is beyond design basis, but not that it requires no further consideration. Another way of looking at this is that the current policy is that

qualitative factors do not allow a conclusion that the likelihood is comparable to other sources of CCF that are not considered in the FSAR. How can a RIS be

used to change previous NRC policy.

I have heard some people say that the current NRC policy is only applicable to new plants. If that is true, which I don't believe it is, then how can the NRC create

a new policy for operating plants that is different than for new plants. This directly contradicts the commissioners direction in (SRM)-SECY-16-0070 that the

guidance for new plants and operating plants should be the same.

Number: 2 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 12:10:01 PM

Dave, You told me that "sufficiently low" could only be reached with 4 factors, the fourth being an evaluation of the "what if" malfunction results. This

contradicts your explanation of this RIS. If your interpretation is confused, the industry's interpretation is also going to be confused.

RIS 2002-22 Supplement 1

Page 7 of 8

features, quality of the design processes, and equipment and software operating experience

that are applied to the proposed design using such standards and guidance can be documented

by licensees when preparing qualitative assessments to support conclusions within a

10 CFR 50.59(c)(2) evaluation that a license amendment is not needed.

In addition, this RIS Supplement clarifies the applicability of some aspects of the NRC policy

described in Item II.Q of SRM/SECY 93-087, Policy, Technical, and Licensing Issues

Pertaining to Evolutionary and Advanced Light Water Reactor Designs, (ADAMS

No. ML003708056), in regard to the application of 10 CFR 50.59(c)(2) criteria for digital I&C

modifications.

To assist licensees in documenting adequate qualitative assessments for evaluating the

10 CFR 50.59(c)(2) criteria, the attachment to this RIS Supplement also clarifies the NRC staff

position on the content, rationale, and evaluation factors that can be addressed and evaluated

within licensee-developed qualitative assessments. Specifically, the attachment describes how

such qualitative assessments can be documented to clearly demonstrate an adequate technical

basis for the conclusion that the change does not require prior NRC staff approval.

BACKFITTING AND ISSUE FINALITY DISCUSSION

This RIS Supplement clarifies but does not supersede RIS 2002-22, and includes additional

guidance regarding how to perform and document qualitative assessments for digital I&C

changes under 10 CFR 50.59.

The NRC does not intend or approve any imposition of the guidance in this RIS Supplement,

and this RIS Supplement does not contain new or changed requirements or staff positions.

Therefore, this RIS Supplement does not represent backfitting as defined in

10 CFR 50.109(a)(1), nor is it otherwise inconsistent with any issue finality provision in

10 CFR Part 52. Consequently, the NRC staff did not perform a backfit analysis for this RIS

Supplement or further address the issue finality criteria in 10 CFR Part 52.

FEDERAL REGISTER NOTIFICATION

The NRC published a notice of opportunity for public comment on this RIS in the Federal

Register on July 3, 2017 (82 FR 30913). The NRC received comments from 13 commenters.

The NRC considered all comments, some of which resulted in changes to the RIS. The

evaluation of these comments and the resulting changes to the RIS are discussed in a

publicly-available memorandum that is available in ADAMS under Accession

No. ML17296A852.

CONGRESSIONAL REVIEW ACT

This RIS is a rule as defined in the Congressional Review Act (5 U.S.C. §§ 801-808). However,

the Office of Management and Budget has not found it to be a major rule as defined in the

Congressional Review Act.

PAPERWORK REDUCTION ACT STATEMENT

This RIS provides guidance for implementing mandatory information collections covered by

10 CFR Part 50 that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et.

This page contains no comments

RIS 2002-22 Supplement 1

Page 8 of 8

seq.). This information collection was approved by the Office of Management and Budget

(OMB) under control number 3150-0011. Send comments regarding this information collection

to the Information Services Branch, U.S. Nuclear Regulatory Commission, Washington, DC

20555-0001, or by e-mail to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of

Information and Regulatory Affairs, NEOB-10202, (3150-0011) Office of Management and

Budget, Washington, DC 20503.

Public Protection Notification

The NRC may not conduct or sponsor, and a person is not required to respond to, a request for

information or an information collection requirement unless the requesting document displays a

currently valid OMB control number.

CONTACT

Please direct any questions about this matter to the technical contact(s) or the Lead Project

Manager listed below.

Timothy J. McGinty, Director

Christopher G. Miller, Director

Division of Construction Inspection

Division of Inspection and Regional Support

and Operation Programs

Office of Nuclear Reactor Regulation

Office of New Reactors

Technical Contacts: David Rahn, NRR

Wendell Morton, NRO

301-415-1315

301-415-1658

e-mail: David.Rahn@nrc.gov

e-mail: Wendell.Morton@nrc.gov

Norbert Carte, NRR

David Beaulieu, NRR

301-415-5890

301-415-3243

e-mail: Norbert.Carte@nrc.gov e-mail: David.Beaulieu@nrc.gov

Duane Hardesty, NRR

301-415-3724

email: Duane.Hardesty@nrc.gov (Specifically for non-power reactors)

Project Manager Contact:

Tekia Govan, NRR

301-415-6197

e-mail: Tekia.Govan@nrc.gov

Note: NRC generic communications may be found on the NRC public Web site,

http://www.nrc.gov, under NRC Library/Document Collections.

Attachment: Qualitative Assessment Framework

This page contains no comments

Attachment

Qualitative Assessment Framework

1. Purpose

Regulatory Issue Summary (RIS) 2002-22 provided the NRC staffs endorsement of Nuclear

Energy Institute (NEI) Guidance document NEI 01-01, Guideline on Licensing Digital Upgrades:

EPRI TR-102348, Revision 1, NEI 01-01: A Revision of EPRI TR-102348 To Reflect Changes

to the 10 CFR 50.59 Rule. NEI 01-01 provides guidance for implementing and licensing digital

upgrades, in a consistent, comprehensive, and predictable manner, as well as guidance in

performing qualitative assessments of the dependability of digital instrumentation and control

(I&C) systems.

The purpose of this attachment is to provide supplemental clarifying guidance to licensees to

ensure that, if qualitative assessments are used, they are described and documented

consistently, through an evaluation of appropriate qualitative evidence available. Following the

guidance in RIS 2002-22 and NEI 01-01, as clarified by the guidance in this RIS Supplement,

will help licensees document qualitative assessments in sufficient detail that an independent

third party can verify the judgements, as stated in NEI 01-01. This RIS supplement guidance

presumes that the qualitative assessment will be performed after all technical work (e.g. failure

modes and effects analysis, and revised design documentation) is complete and that the

proposed modification has already been determined to have a potential adverse effect (i.e. it

has been screened in as described in NEI 96-07).

If the qualitative assessment determines that a potential failure (e.g., software common cause

failure [CCF]) has a sufficiently low likelihood, then the effects of this failure do not need to be

considered in the 10 CFR 50.59 evaluation. In particular, this qualitative assessment provides

a means of addressing software CCF.

This RIS Supplement includes guidance that licensees may use to develop adequate bases for

determining that (1) a digital modification will exhibit a sufficiently low likelihood of failure, or, (2)

if a digital I&C modification failure can be postulated, the effects of that failure will not result in a

new type of accident or a malfunction of structures, systems, and components (SSCs) with

different result than previously evaluated in the updated final safety analysis report (UFSAR).

The determination of whether a modification will exhibit a sufficiently low likelihood of failure is a

key element in 10 CFR 50.59. Licensees need to understand the possible effects of failures of

a digital I&C modification to ensure that such effects will not create a possibility for an accident

of a different type or a malfunction of an SSC with a different result than previously evaluated in

the updated final safety analysis report.

The sections that follow provides one approach, acceptable to the NRC staff, for describing the

scope, form, and content of a qualitative assessment.

2. Regulatory ClarificationApplication of Qualitative Assessments to Title 10 of the

Code of Federal Regulations, Section 50.59

After determining that an activity is safe and effective through appropriate engineering and

technical evaluations, the 10 CFR 50.59 process is applied. 10 CFR 50.59 provides a threshold

for regulatory review, not the final determination of safety, for the proposed activities.

10 CFR 50.59 establishes the conditions under which licensees may make changes to the

facility or procedures and conduct tests or experiments without prior NRC approval.

1

2

3

4

Page: 9

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 9:38:55 AM

Licensees will often conduct these evaluations prior to investing in revised design/analysis documentation.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:37:49 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 9:40:45 AM

Dave, This does not say that a failure must be postulated.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:40:15 AM

RIS 2002-22 Supplement 1, Attachment

Page 2 of 27

Evaluations must address all elements of proposed changes. Elements of a change can have

positive effects on SSC failure likelihood while other elements of the change can have adverse

effects. As derived from the guidance in NEI 96-07, positive and negative elements can be

considered together if they are interdependent. This means that if elements are not

interdependent, they must be evaluated separately.

When discussing 10 CFR 50.59 criteria, the words met or satisfy mean that a yes or

affirmative answer has been achieved and an amendment is required.

2.1 Likelihood Justifications

Qualitative assessments are needed to document the bases to support a conclusion that a

proposed digital I&C modification has a sufficiently low2 likelihood of failure, consistent with the

UFSAR analysis assumptions. This conclusion is used in the Title 10 of the Code of Federal

Regulations (10 CFR) 50.59, Changes tests and experiments, written evaluation to determine

whether prior NRC approval is required.

The staff notes that when performing digital modifications under 10 CFR 50.59, some licensees

have experienced challenges in preparing qualitative assessments needed to support

conclusions for responding to the criteria in 10 CFR 50.59(c)(2)(i), (ii), (v), and (vi).

The ability to provide an adequate basis for a determination that the digital modification will

exhibit a sufficiently low likelihood of failure is a key element of 10 CFR 50.59 evaluations to

determine whether the change requires prior NRC approval. To support the 10 CFR 50.59

process, methods are needed to evaluate the digital system likelihood of failure (e.g., based on

the dependability of the modified digital components) that could result in a malfunction of an

SSC important to safety. For digital equipment, however, there may not be well-established,

accepted quantitative methods that can be used to estimate their dependability or likelihood of

failure. Therefore, for digital SSCs, an adequate basis for determining sufficiently low likelihood

of failure may be derived from a qualitative assessment of factors involving the inclusion of key

system design features,3 the quality of the design process used, and an evaluation of relevant

operating experience (i.e., product maturity and in-service experience). The qualitative

assessment reaches a conclusion through engineering judgment that there is an adequate basis

for concluding that the digital modification will exhibit a sufficiently low likelihood of failure by

considering the aggregate of these factors.

Likelihood Thresholds for 10 CFR 50.59(c)(2)(i), (ii), (v), and (vi)

A key element of 10 CFR 50.59 evaluations is demonstrating that the modification will exhibit a

sufficiently low likelihood of failure. For digital modifications, particularly those that introduce

software, there may be the potential increase in likelihood of failure, including a single failure.

2 NEI 01-01, Page 4-20, defines sufficiently low to mean much lower than the likelihood of failures that are

considered in the UFSAR (e.g., single failures) and comparable to other common cause failures that are not

considered in the UFSAR (e.g., design flaws, maintenance errors, calibration errors).

3 System design features are used to address anticipatable and quantifiable threats (e.g., the qualification of a piece

of equipment to meet the plant seismic criteria ensures that the likelihood of failure from seismic event is sufficiently

low). Defense-in-depth and diversity are system design features to address anticipatable but non-quantifiable threats

(e.g., software CCF). These deterministic measures must be implemented under the appropriate quality processes.

1

2

Page: 10

Number: 1 Author: KenSc

Subject: Highlight

Date: 01/23/2018 10:53:30 PM

Number: 2 Author: KenSc

Subject: Sticky Note Date: 01/23/2018 10:53:57 PM

No postulation of CCF.

RIS 2002-22 Supplement 1, Attachment

Page 3 of 27

For redundant SSCs, this potential increase in the likelihood of failure creates a similar increase

in the likelihood of a common cause failure.

The sufficiently low threshold discussions have been developed using criteria from NEI 96-07,

Revision 1, and NEI 01-01. They are intended to clarify the existing 10 CFR 50.59 guidance

and should not be interpreted as a new or modified NRC position.

Qualitative Assessment

The determination that a digital I&C modification will exhibit a sufficiently low likelihood of failure

can be derived from a qualitative assessment of factors involving system design attributes, the

quality of the design processes employed, and the operating experience of the software and

hardware used (i.e., product maturity and in-service experience). The qualitative assessment

documents the factors, rationale, and reasoning for determining that the digital I&C modification

exhibits a sufficiently low likelihood of failure by considering the aggregate of these factors.

The determination of likelihood of failure may consider the aggregate of all the factors described

above. Some of these factors may compensate for weaknesses in other areas. For example,

for a digital device that is simple and highly testable, thorough testing may provide additional

assurance of a low likelihood of failure that helps compensate for a lack of operating

experience.

Qualitative Assessment Outcome

There are two possible outcomes of the qualitative assessment: (1) failure likelihood is

sufficiently low, and (2) failure likelihood is not sufficiently low. NEI 01-01, Section 4.3.6,

states, sufficiently low means much lower than the likelihood of failures that are considered in

the UFSAR (e.g., single failures) and comparable to other common cause failures that are not

considered in the UFSAR (e.g., design flaws, maintenance error, calibration errors). [Note:

This sufficiently low threshold is not interchangeable with that for distinguishing between

events that are credible or not credible. The threshold for determining whether an event is

credible or not is whether it is as likely as (i.e., not much lower than) malfunctions already

assumed in the UFSAR.]

Criteria

A qualitative assessment outcome of sufficiently low supports a no or negative answer for

10 CFR 50.59(c)(2)(i), (ii), (v), and (vi) as follows:

10 CFR 50.59(c)(2)(i)

Does the activity result in more than a minimal increase in the frequency of occurrence of an

accident previously evaluated in the UFSAR?

Sufficiently low threshold - The frequency of occurrence of an accident is directly

related to likelihood of failure of equipment that initiates the accident (e.g., an increase in

the likelihood of a steam generator tube failure has a corresponding increase in the

frequency of a steam generator tube rupture accident). Thus, an increase in likelihood

of failure of the modified equipment results in an increase in the frequency of the

accident. Therefore, if the qualitative assessment outcome is sufficiently low, then

1

2

3

4

5

6

Page: 11

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 9:47:22 AM

This is technically incorrect. Single failures, by definition are random, non-systematic failures. An increase in the likelihood of a single failure, does lower system

availability, but it does not increase the likelihood of a CCF.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 9:44:37 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:18:38 AM

Should be NEI 01-01 Section 4.4.6.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:18:44 AM

Number: 5 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:04:39 AM

This note just adds confusion because it says that if a failure is not credible but not sufficiently low likelihood it must be considered.

Number: 6 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:03:46 AM

RIS 2002-22 Supplement 1, Attachment

Page 4 of 27

there is a no more than a minimal increase in the frequency of occurrence of an accident

previously evaluated in the UFSAR.

10 CFR 50.59(c)(2)(ii)

Does the activity result in more than a minimal increase in the likelihood of occurrence of a

malfunction of a structure, system, or component (SSC) important to safety4 previously

evaluated in the UFSAR?

Sufficiently low threshold - The likelihood of occurrence of a malfunction of an SSC

important to safety is directly related to likelihood of failure of equipment that causes a

failure of SSCs to perform their intended design functions (e.g., an increase in the

likelihood of failure of an auxiliary feedwater (AFW) pump has a corresponding increase

in the likelihood of occurrence of a malfunction of SSCs - the AFW pump and AFW

system). Thus, the likelihood of failure of modified equipment that causes the failure of

SSCs to perform their intended design functions is directly related to the likelihood of

occurrence of a malfunction of an SSC important to safety. Therefore, if the qualitative

assessment outcome is sufficiently low, then the activity does not result in more than a

minimal increase in the likelihood of occurrence of a malfunction of an SSC important to

safety previously evaluated in the UFSAR.

10 CFR 50.59(c)(2)(v)

Does the activity create a possibility for an accident of a different type than any previously

evaluated in the UFSAR?

Sufficiently low threshold - NEI 96-07, Revision 1, Section 4.3.5, states, Accidents of

a different type are limited to those as likely to happen as those in the UFSAR.

Accidents of a different type are caused by failures of equipment that initiate an accident

of a different type. Only failures of equipment that are as likely to happen as those in

the UFSAR can create a possibility of an accident of a different type. If the qualitative

assessment outcome is sufficiently low, then there are no failures introduced by the

activity that are as likely to happen as those in the UFSAR that can initiate an accident of

a different type. Therefore, the activity does not create a possibility for an accident of a

different type than any previously evaluated in the UFSAR.

10 CFR 50.59(c)(2)(vi)

Does the activity create a possibility for a malfunction of an SSC important to safety with a

different result than any previously evaluated in the UFSAR?

Sufficiently low threshold - NEI 96-07, Section 4.3.6, states, Malfunctions with a

different result are limited to those as likely to happen as those in the UFSAR. A

malfunction of an SSC important to safety is an equipment failure that causes the failure

of SSCs to perform their intended design functions. Only failures of equipment that are

as likely to happen as those in the UFSAR can create a possibility of a malfunction

4 NEI 96-07, Revision 1, Section 3.9, states, Malfunction of SSCs important to safety means the failure of SSCs to

perform their intended design functions described in the UFSAR (whether or not classified as safety-related in

accordance with 10 CFR 50, Appendix B).

1

2

3

4

5

6

Page: 12

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:12:33 AM

This contradicts previous statements in this RIS and in NEI 01-01 which state to require no further consideration in 50.59, the failure likelihood must be

"comparable to other common cause failures that are not

considered in the UFSAR".

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:12:30 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:07:57 AM

Yes, but the sentence above says that even if you have not reached the "sufficiently low" threshold, there are no new accidents introduced unless the failure is

"as likely" as other failures assumed in the FSAR. This is quite confusing.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:05:54 AM

Number: 5 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:11:38 AM

This contradicts previous statements in this RIS and in NEI 01-01 which state to require no further consideration in 50.59, the failure likelihood must be

"comparable to other common cause failures that are not

considered in the UFSAR".

Number: 6 Author: KenSc

Subject: Highlight

Date: 01/23/2018 10:57:32 PM

RIS 2002-22 Supplement 1, Attachment

Page 5 of 27

with a different result. If the qualitative assessment outcome is sufficiently low, then

there are no failures introduced by the activity that are as likely to happen as those in the

UFSAR. Therefore, the activity does not create a possibility for a malfunction of an SSC

important to safety with a different result than any previously evaluated in the UFSAR.

2.2 Additional Considerations for 10 CFR 50.59 evaluation of criterion (c)(2)(vi)

The 10 CFR 50.59 evaluation of criterion (c)(2)(vi) can be viewed as a five-step process that

stems from NEI 96-07, Revision 1, Section 4.3.6, which states: The possible malfunctions with

a different result are limited to those that are as likely to happen as those described in the

UFSAR. This section provides excerpts from NEI 96-07, Revision 1, and NEI 01-01 and

groups them into five steps to more clearly describe the considerations for addressing

10 CFR 50.59 criterion (c)(2)(vi). The section should not be interpreted as creating new or

revised NRC positions:

Step 1: Develop a list of ways (i.e., failure modes of SSCs important to safety that are affected

by the proposed modification) in which SSCs can fail to perform their intended design functions.

malfunction of SSCs important to safety means the failure of SSCs to perform their

intended design functions described in the UFSAR (whether or not classified as

safety-related in accordance with 10 CFR Part 50, Appendix B.) [NEI 96-07, Rev. 1,

Section 3.9, Definition of Malfunction of SSCs, page 18.]

Step 2: Perform a qualitative assessment of the likelihood of occurrence of each failure mode to

determine which ones are as likely to happen as those described in the UFSAR.

For digital systems, reasonable assurance of adequate quality and low likelihood of

failure is derived from a qualitative assessment of the design process and the system

design features. [NEI 01-01, Section 5.3.1, page 5-14]

If the qualitative assessment outcome is not sufficiently low, then perform Steps 3, 4, and 5 to

evaluate the results of these failures against 10 CFR 50.59 criterion (c)(2)(vi).

Step 3: Determine the malfunction results.

The key issue is the effect of failures of the digital device on the system in which it is

installed. [NEI 01-01, Section 4.4.6, page 4-19]

Another way to determine the appropriate level of detail is to consider the level at which

design functions are described in the UFSAR. If the relevant design functions are

assigned at the system level, then it is appropriate to evaluate the effects of malfunctions

at this level. [NEI 01-01, Section 4.4.6, page 4-19]

If failures of the digital device cause the system to malfunction (i.e., not perform its

design function), then the evaluation needs to determine if the result of the system

malfunction is bounded by or different than those previously evaluated. [NEI 01-01,

Section 4.4.6, page 4-19]

1

2

3

4

5

6

7

8

9

10

Page: 13

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:20:03 AM

This contradicts NEI 01-01 which says to require no further consideration the failure likelihood must be "comparable to other common cause failures that

are not

considered in the UFSAR", not as likely as those that are considered.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:13:32 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:21:57 AM

Needs to also include ways of erroneous performance. You can argue that "failure" encompasses "erroneous" but erroneous is too often overlooked by digital

designers.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/23/2018 10:58:55 PM

Number: 5 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:27:10 AM

This should say "which ones that are not as unlikely as failures not considered in the FSAR" or "which one whose likelihood is not comparable to other

common cause failures that are not

considered in the UFSAR."

Number: 6 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:22:20 AM

Number: 7 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:53:43 AM

"as likely as those described in the FSAR" contradicts "comparable to other common cause failures that are not

considered in the UFSAR", which is your definition of "sufficiently low". These are two different thresholds. So it is not clear when Steps 3-5 are needed. This

RIS is supposed to bring clarity to the 50.59 issue, not more ambiguity.

Number: 8 Author: KenSc

Subject: Highlight

Date: 01/23/2018 11:00:26 PM

Number: 9 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:33:03 AM

Clarify that "end result" means "plant level".

Number: 10

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:28:29 AM

RIS 2002-22 Supplement 1, Attachment

Page 6 of 27

NEI 01-01, Section 5.2, page 5-10 states that, reanalysis of design basis events is

permitted using best estimate conditions and realistic assumptions Unless already

incorporated into the design and licensing basis, best-estimate methods cannot be

used for evaluating different results than those previously evaluated in the UFSAR. For

failures in which likelihood is not sufficiently low, the results of these failures are to be

analyzed using methods consistent with the plants design and licensing basis.

An example of a change that would create the possibility for a malfunction with a

different result is a substantial modification or upgrade to control station alarms, controls,

or displays that are associated with SSCs important to safety that creates a new or

common cause failure that is not bounded by previous analyses or evaluations. [NEI

96-07, Section 4.3.1, page 55.]

If a feedwater control system is being upgraded from an analog to a digital system, new

components may be added that could fail in ways other than the components in the

original design. Provided the end result of the component or subsystem failure is the

same as, or is bounded by, the results of malfunctions currently described in the UFSAR

(i.e., failure to maximum demand, failure to minimum demand, failure as-is, etc.), then

this upgrade would not create a malfunction with a different result. [NEI 96-07, Section

4.3.6, page 54; also see NEI 01-01, Section 4.4.6, page 4-19.]

Note that [for criterion (vi)] new types of malfunctions are not the issue. NEI 96-07,

Revision 1, states that a new failure mechanism is not a malfunction with a different

result if the result or effect is the same as, or is bounded by, that previously evaluated in

the UFSAR. [NEI 01-01, Section 4.4.6, page 4-19]

Step 4: Identify the associated malfunctions and results previously evaluated in the UFSAR.

the evaluation needs to consider the level of detail that was previously evaluated in the

UFSAR (i.e., component versus division/train versus system level failures). [NEI 01-01,

Section 4.4.6, page 4-19]

Another way to determine the appropriate level of detail is to consider the level at which

design functions are described in the UFSAR. If the relevant design functions are

assigned at the system level, then it is appropriate to evaluate the effects of malfunctions

at this level. [NEI 01-01, Section 4.4.6, page 4-19]

Step 5: Compare the newly created results to the results of malfunctions previously evaluated

in the UFSAR. If the created results are not bounded by the previously evaluated results,

then an LAR is required.

Once the malfunctions previously evaluated in the UFSAR and the results of these

malfunctions have been determined, then the types and results of failure modes that the

proposed activity could create are identified. Comparing the two lists can provide the

answer to the criterion question. [NEI 96-07, Rev. 1, Section 4.3.6, page 55]

A new failure mechanism is not a malfunction with a different result if the result or effect

is the same as, or is bounded by, that previously evaluated in the UFSAR. [NEI 01-01,

Section 4.4.6, page 4-19]

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

Page: 14

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:49:34 AM

This is new NRC policy that clearly contradicts the quote in this paragraph from NEI 01-01, which is previously endorsed by NRC. It is not clarification of

previous policy. It also contradicts SECY 93-087 and BTP 7-19. A RIS cannot change previous NRC policy.

Regardless, "best estimate" methods are used in most, maybe all, FSARs for ATWS, SBO and fire. So they are used in the FSAR, therefore even with this new

policy they can be used to evaluate CCFs when the CCF is considered beyond design basis (i.e., significantly less likely than other malfunctions considered in

design basis events).

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/23/2018 11:02:45 PM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:33:15 AM

Clarify that "end result" means "plant level".

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:31:39 AM

Number: 5 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:34:04 AM

These are failure modes or component level effects. They are not the "end result"

Number: 6 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:34:02 AM

Number: 7 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:44:51 AM

What does it mean to be "bounded". This RIS needs to provide guidance, because this is a particular area for frequent industry inconsistency.

Number: 8 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:34:56 AM

Clarify that "end result" means "plant level".

Number: 9 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:34:29 AM

Number: 10

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:44:57 AM

Number: 11

Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:47:18 AM

This is not clear. All design functions are assigned at the system level. But the effects of system level failures are determined at the plant level. Clarity is needed

here because this is another area of frequent industry inconsistency.

Number: 12

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:46:06 AM

Number: 13

Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:47:45 AM

define "bounded"

Number: 14

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:47:34 AM

Number: 15

Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:48:50 AM

"results" appears to have two different meanings. This needs clarification.

Number: 16

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:48:19 AM

Number: 17

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:48:24 AM

Number: 18

Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:52:10 AM

"bounded" is used in three quotes on this page. But it is never defined here or in NEI 01-01. A definition is clearly needed.

Number: 19

Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:51:10 AM

RIS 2002-22 Supplement 1, Attachment

Page 7 of 27

3. Producing Qualitative Assessments that Support a Sufficiently Low Likelihood

Conclusion

The qualitative assessment framework described herein may be used to develop and document

the technical basis supporting a conclusion that a proposed digital modification satisfies each of

the likelihood thresholds outlined above. The resulting qualitative assessments may then be

used as part of the reasoning and rationale serving as the basis for a 10 CFR 50.59 evaluation.

The NRC staff has determined that proposed digital I&C modifications having all the

characteristics listed below are likely to result in qualitative assessment results that support a

determination that a license amendment is not required by 10 CFR 50.59:

[Note: The term design functions, as used in this RIS Supplement, conforms to the

definition of design functions in NEI 96-07, Revision 1.]

1. Digital I&C design-functions replacing I&C design-functions that:

a) Do not create a CCF vulnerability due to the integration of subsystems or

components from different systems that combine design functions that were not

previously combined within the same system, subsystem, or component being

replaced, and

b) Do not create a CCF vulnerability due to the incorporation of new shared resources

(such as power supplies, controllers, and human-machine interfaces) with other

design functions either explicitly (or implicitly) described in the final safety analysis

report as updated (UFSAR) as functioning independently from other plant system

functions, or modeled in the current design basis to be functioning independently

from other plant design functions, and

c) Do not affect reactor trip or engineered safety feature initiation/control logic design

functions.

Integration, as used in this RIS clarification refers to the process of combining software

components, hardware components, or both into an overall system, or the merger of the

design function of two or more systems or components into a functioning, unified system

or component. Integration also refers to the coupling of design functions (software/

hardware) via digital communications. Modifications can result in design functions of

different systems being integrated or combined either directly in the same digital device

or indirectly via shared resources, such as digital communications or networks, common

controllers, power supplies, or visual display units. Such integration could be

problematic because the safety analysis may have explicitly or implicitly modeled the

equipment performing the design functions that would be integrated on the basis that it is

not subject to any potential source of common cause failure.

2. Digital I&C modifications to SSCs that do not result in a CCF vulnerability due to a

reduction of any aspect of independence (or separation), single failure tolerance, or

diversity credited in the UFSAR (including a reduction in diversity due to hardware or

software resources shared among non-safety related control functions); and

3. Digital I&C modifications to facility SSCs, where a malfunction due to a design defect is

precluded through: (a) simplicity (as demonstrated through 100 percent testing or a

combination of testing and input/output state analysis); or (b) a demonstration of

1

2

Page: 15

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 10:58:08 AM

The same software in different systems could be considered a "shared resource". So change to "shared hardware resource".

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:56:17 AM

RIS 2002-22 Supplement 1, Attachment

Page 8 of 27

adequate internal or external systematic diversity, or where a design defect is assumed,

postulated to be triggered, and demonstrated to result in no new malfunction or a

malfunction that is bounded at the level previously evaluated in the safety analysis.

Licensees may evaluate digital I&C modifications to SSCs associated with reactor protection

systems and ESF actuation systems using the qualitative assessment clarification in this RIS

Supplement with the following four considerations: (1) the proposed modification is not part of

the actuation/control logic portion of reactor protection systems and ESF systems, (2) the

proposed modification is not an extension of an ESF actuation, such as emergency power bus

load sequencers, (3) the design function will continue to be accomplished and the proposed

design will continue to satisfy applicable NRC requirements, and (4) any new input or output

devices do not communicate with the actuation logic portion of reactor protection systems or

ESF actuation systems using digital data communications. This would include possible

changes to individual, non-shared channel inputs to reactor protection systems logic, reactor

protection systems power supplies, or output actuators (relays/breakers). Proposed

modifications beyond these types would likely require a license amendment.

4. Qualitative Assessment

4.1. Quantitative vs. Qualitative

A quantitative assessment is one capable of representing the SSC by a mathematical model,

such as apportioning the reliability and availability goals among parts of the system, assigning

probabilities to each failure mode of concern, and reconciling the calculated estimates of

reliability and availability with the overall SSC goals. A qualitative assessment identifies

possible ways in which an SSC can fail, and identifies appropriate precautions (design changes,

administrative procedures, etc.) that will reduce the frequency or consequences of such failures.

For example, a licensee may be able to rely on a qualitative assessment of a particular digital

controller even if it is difficult to demonstrate that the controller uses an error-free operating

system and error-free application-specific system software logic commands. Specifically, it may

be possible to demonstrate qualitatively that the controller has a set of specific attributes that

allow its installation without prior NRC approval. One acceptable set of attributes is that (1)

software for that controller has been prepared using a high-quality software development

process, (2) the controller was tested thoroughly during acceptance and post-installation tests,

and (3) the particular controller has been used in tens of thousands of hours of successful

operation at other locations under similar plant conditions and for similar purposes, and there

has been no evidence of operational failures due to software defects.

The qualitative assessment conclusion makes use of engineering judgment. As stated above,

NEI 01-01 describes that for 10 CFR 50.59 evaluations, the likelihood of failure is normally

demonstrated qualitatively (i.e., through reference to reasonable engineering practices and

engineering judgment) particularly for systems or components that rely on software, because

there are no well-established, accepted quantitative methods to demonstrate the likelihood of

failure from software design errors. When applying engineering judgment, the following

principles and general considerations may be followed:

The technical qualifications of the personnel performing such evaluations will be appropriate

for the evaluation preparation and reviews.

The evaluation process follows the applicable corporate engineering or plant engineering

procedures for performing such engineering evaluations or calculations.

1

2

3

4

5

6

7

8

Page: 16

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:00:58 AM

This contradicts previous sections which say that the malfunction must be analyzed only if the likelihood is not "sufficiently low" based on a qualitative

assessment. Here you say that analysis is needed to reach the "sufficiently low" threshold. This is quite confusing.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 10:59:25 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:01:26 AM

Very unclear. See previous comments.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:01:11 AM

Very

Number: 5 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:04:42 AM

Even if you hardwire a signal from a digital device, the digital device itself can create an erroneous signal that could adversely affect RPS/ESF. Digital data

communication creates an additional communication independence vulnerability. But it has no effect (positive or negative) on functional independence.

Number: 6 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:02:46 AM

Number: 7 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:07:50 AM

Per previous NRC policy, all of these attributes facilitate a conclusion of sufficiently low likelihood to be analyzed using "best estimate" methods. Not sufficiently

low to require no further consideration. This RIS is changing NRC policy.

Number: 8 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:07:41 AM

RIS 2002-22 Supplement 1, Attachment

Page 9 of 27

The basis for conclusions relying on engineering judgment are clearly documented in the

evaluation/analysis.

A sound technical basis or rationale for the judgment (e.g., recognized engineering

principles, standards, trend evaluations, and empirical data; previous engineering

experience, calculations, or evaluations; demonstrated industry practices, etc.) is

established.

The level of detail used to justify the engineering judgment may be commensurate with the

safety significance and complexity of the design function affected in accordance with

licensees procedures.

The level of detail permits another technical reviewer with similar expertise, and without

recourse to the author, to understand the author's rationale.

Simplified models and estimation techniques can provide supporting bases for engineering

judgement.

4.2. Overview of Design Information that Supports Qualitative Assessments

Technical information is needed to support a conclusion that a proposed digital I&C modification

will exhibit a sufficiently low likelihood of failure. As described in greater detail below, an

adequate basis for determining sufficiently low likelihood of failure may be derived from a

qualitative assessment of factors involving the inclusion of key system design features, the

quality of the design process used, and an evaluation of relevant operating experience (i.e.,

product maturity and in-service experience). The qualitative assessment reaches a conclusion

through engineering judgment that there is an adequate basis for concluding that the digital

modification will exhibit a sufficiently low likelihood of failure by considering the aggregate of

these factors. Section 5 of this Attachment provides further discussion regarding technical

information supporting qualitative assessments.

4.3. Qualitative Assessment Categories

Consistent with the guidance provided in NEI 01-01, this attachment specifies three general

categories of proposed design-related characteristics (described in Table 1 of this document)

that can be used to develop justifications that demonstrate a sufficiently low likelihood of failure

for a proposed modification. The aggregate of the three qualitative assessment categories form

the technical basis for developing justifications based upon the likelihood of failure (i.e., single

failures and CCF) of a digital I&C modification to a system or components. The aggregate of all

three categories below needs to be evaluated to demonstrate that there is an adequate basis for

concluding that the proposed modification will exhibit a sufficiently low likelihood of failure such

that the criteria described in Section 2 of this attachment can be addressed:

Design attributes:

NEI 01-01 Section 5.3.1 states:

To determine whether a digital system is sufficiently dependable, and

therefore that the likelihood of failure is sufficiently low, there are some

important characteristics that should be evaluated. These characteristics,

discussed in more detail in the following sections include. . .

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 10 of 27

Hardware and software design features that contribute to high

dependability (See Section 5.3.4). Such [hardware and software design]

features include built-in fault detection and failure management schemes,

internal redundancy and diagnostics, and use of software and hardware

architectures designed to minimize failure consequences and facilitate

problem diagnosis.

Consistent with the above-quoted text, design attributes of the proposed modification

can prevent or limit failures from occurring or mitigate the consequences of such

possible failures. The qualitative assessment documents and describes hardware and

software design features that contribute to high dependability. Design attributes focus

primarily on built-in features such as fault detection and failure management schemes,

internal redundancy and diagnostics, and use of software and hardware architectures

designed to minimize failure consequences and facilitate problem diagnosis. However,

design features external to the proposed modification (e.g., mechanical stops on valves)

may also need to be considered.

During the design process, it is important to consider both the positive effects of

installing the digital equipment (e.g., elimination of single-point vulnerabilities (SPVs),

ability to perform signal validation, diagnostic capabilities, etc.) with the potential

negative effects (e.g., software CCF, etc.).

Within the concept of defense-in-depth, acceptable justification for concluding an

accident of a different type will not be initiated could include, if supported by the facts,

that the postulated new accident is only possible after a sequence of multiple unlikely

independent failures. This type of justification is summarized and documented as part of

the qualitative assessment.

Quality of the Design Process:

Section 5.3.3 of NEI 01-01 states:

For digital equipment incorporating software, it is well recognized that

prerequisites for quality and dependability are experienced software

engineering professionals combined with well-defined processes for

project management, software design, development, implementation,

verification, validation, software safety analysis, change control, and

configuration control.

Consistent with the guidance provided in NEI 01-01, Quality Design Processes means

those processes employed in the development of the proposed modification. Such

processes include software development, hardware and software integration processes,

hardware design, and validation and testing processes that have been incorporated into

the development process. Although in many cases this development process would be

documented and available for referencing in the qualitative assessment for proposed

modifications to safety-related equipment, for commercial- grade-dedicated or

non-safety related equipment it may not be readily available. In such cases, the

qualitative assessment may place greater emphasis on the design attributes included

and the extent of successful operating experience for the equipment proposed.

1

2

3

Page: 18

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:10:25 AM

Limiting and mitigating do not reduce the likelihood of the failure.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:09:58 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:12:29 AM

This paragraph is not related to design attributes that reduce the likelihood of failure. It is about tolerating the failure. This paragraph should be deleted or

moved.

RIS 2002-22 Supplement 1, Attachment

Page 11 of 27

Operating Experience:

Section 5.3.1 of NEI 01-01 states, Substantial applicable operating history reduces

uncertainty in demonstrating adequate dependability.

Consistent with the above-quoted text, relevant operating experience can be used as a

means to help demonstrate that software and hardware employed in a proposed

modification have adequate dependability. The licensee may document information

showing that the proposed system or component modification employs equipment with

significant operating experience in nuclear power plant applications, or in non-nuclear

applications with comparable performance standards and operating environment. The

licensee may also consider whether the suppliers of such equipment incorporate quality

processes such as continual process improvement, incorporation of lessons learned,

etc., and document how that information demonstrates adequate equipment

dependability.

These categories are not mutually exclusive and may overlap in certain areas. Adequate

qualitative assessments for SSCs fully address each of the above categories. Qualitative

assessment documentation for the proposed modification to SSCs is retained in accordance

with the licensees design engineering procedures, procedures implementing

10 CFR 50.59(d)(1), and NRC-approved QA program.

Table 1 provides acceptable examples of design attributes, quality of the design processes, and

documentation of operating experience. This listing is not all inclusive, it merely provides

examples. Licensees may consider additional design attributes, quality of the design

processes, and documentation of operating experience in their qualitative assessment and need

not use these specific examples.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 12 of 27

Table 1Qualitative Assessment Category Examples

Categories

Acceptable Examples for Each Category

Design Attributes

Design criteriaDiversity (if applicable), Independence, and

Redundancy.

Inherent design features for software, hardware or

architectural/network Watchdog timers that operate independent of

software, isolation devices, segmentation, self-testing, and self-

diagnostic features.

Basis for identifying that possible triggers are non-concurrent.

Sufficiently simple (i.e., enabling 100 percent testing or

comprehensive testing in combination with analysis of likelihood of

occurrence of input/output states not tested).

Unlikely series of eventsEvaluation of a given digital I&C

modification would necessarily have to postulate multiple independent

random failures in order to arrive at a state in which a CCF is

possible.

Failure state always known to be safe, or at least the same state as

allowed by the previously installed equipment safety analysis.

Quality of the

Design Process

Justification for use of industry consensus standardsfor codes and

standards not endorsed by the NRC.

Justification for use of the other standards.

Justification for applicability of standards used.

Use of Appendix B vendors. If not an Appendix B vendor, the

analysis can state which generally accepted industrial quality program

was applied.

Use of Commercial Grade Dedication processes per guidance of

EPRI TR-106439, Annex D of IEEE 7-4.3.2, and examples within

EPRI TR-107339.

Demonstrated tolerance (e.g., through qualification testing) to

withstand environmental conditions within which the SSC is credited

to perform its design function (e.g., EMI/RFI, Seismic).

Development process rigor (adherence to generally-accepted

commercial or nuclear standards.)

The use of custom software using code for application software will

typically call for extensive evaluation or testing or both to demonstrate

dependability, where there is inadequate information to conclude that

a quality design process has been used.

Operating

Experience

Wide range of operating experience in similar applications, operating

environments, duty cycles, loading, comparable configurations, etc.,

to that of the proposed modification.

History of lessons learned from field experience addressed in the

design.

Relevant operating experience: Architecture of the referenced

equipment and software along with the design conditions and modes

of operation of the equipment should be substantially similar to those

of the system being proposed as a digital I&C modification.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 13 of 27

4.3.1 Design Attributes to Reduce the Likelihood of Failure

Many system design attributes, procedures, and practices can contribute to significantly

reducing the likelihood of failure (e.g., CCF). A licensee can account for this by deterministically

assessing the specific vulnerabilities through the introduction of failure modes (e.g., software

CCF) within a proposed modification and applying specific design attributes to address those

vulnerabilities (see Table 1 above). An adequate qualitative justification regarding the likelihood

of failure of a proposed modification would consist of a description of: (a) the identified

vulnerabilities of the proposed modification, (b) the design attributes used to address the

identified vulnerabilities, and (c) a clear description explaining why the chosen design attributes

and features are adequate.

Changes in control system design need to be evaluated for potential vulnerabilities to CCF. In

addition, there are some SSCs that have few applicable requirements (e.g. no diversity or

redundancy requirements). These SSCs may have been implemented in a manner (i.e.,

relatively independently) such that only individual SSC malfunctions or failures were considered

in the UFSAR. If these individual SSCs are combined with (e.g., controlled by a common digital

component, employ the same software in separate digital devices), or are coupled to each other

(e.g., by digital communication), then the potential for malfunctions with a different result or

accidents of a different type would be evaluated under 10 CFR 50.59.

4.3.1.1 Diversity and Common Cause Failure

Diversity is one example of a design attribute of an SSC that can be used as part of the bases

for demonstrating an SSC modified with digital technology will exhibit a low likelihood of a loss

of design function due to a potential common cause failure. The design of certain SSCs is

required to include diversity to the extent practical. (For example, for protection systems,

diversity is to be used to the extent practical to prevent loss of the protection function.

(10 CFR Part 50 Appendix A, Criterion 22.)). Some licensees have already followed staff

guidance, such as NUREG-0800, Chapter 7, Branch Technical Position 7-19, in establishing the

High volume production usage in different applicationsNote that for

software, the concern is centered on lower volume, custom, or

user-configurable software applications. High volume, high quality

commercial products with relevant operating experience used in other

applications have the potential to avoid design errors.

Evaluation of the operating experience for specific versions of

operating system software designed by high quality commercial grade

equipment vendors may be one of the only means by which a degree

of assurance of reliability may be judged. For some applications and

custom-developed software, operating experience may be the most

reliable justification that the software is acceptable. It may be

necessary to delay implementing major application software use and

software revisions until the software version has sufficient operating

experience.

The operating system and application level software may need to be

considered. In some cases it may be necessary to address vendor

software that creates the configuration files as well as the

configuration file itself.

1

2

Page: 21

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:18:10 AM

Clarify that this refers to functional diversity. Implementation diversity is not required in the protection system by 10CFR Part 50 Appendix A. Implementation

diversity is only required by 50.62 for ATWS, which is a beyond design basis event for which "best estimate" methods are permitted.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:16:14 AM

RIS 2002-22 Supplement 1, Attachment

Page 14 of 27

design basis of certain SSCs. Further, some SSCs are subject to existing regulatory

requirements or other acceptance criteria to which the licensee is committed, and include

diversity in the design. In these cases, the licensees have incorporated diversity into the design

basis. In all other cases, the licensees need not consider the use of diversity (i.e., as described

in the staff requirements memorandum on SECY 93-087) in evaluating a proposed modification

under 10 CFR 50.59. However, diversity within the proposed design, and any affected SSCs is

a powerful means which may significantly reduce the likelihood of malfunctions affecting the

accomplishment of design functions.

4.3.1.2 Digital Communications

Digital communications can reduce SSC independence credited or assumed in the UFSAR.

Reduction in independence may create the possibility of a new failure that could result in

concurrent failures not considered in the UFSAR. Careful consideration is needed to preclude

adverse effects on safety and non-safety related SSC independence. DI&C-ISG-04, Revision 1,

Highly-Integrated Control RoomsCommunications Issues (ADAMS Accession Number

ML083310185) provides an acceptable means of addressing digital communication between

redundant SSCs, echelons of defense-in-depth, or SSCs with different safety classifications.

DI&C-ISG-04 was developed to address digital communication among safety-related and

between safety-related and non-safety related SSCs. The principles of this ISG or other

technically justifiable considerations, may be used to assess non-safety related SSCs.

4.3.1.3 Combining (Integration) of Functions

Combining design functions of different safety-related or non-safety related SSCs in a manner

not previously evaluated or described in the UFSAR could introduce new interdependencies and

interactions that make it more difficult to account for new potential failure modes (i.e., single

failures and CCF). Failure of combined design functions that: 1) can effect malfunctions of

SSCs or accidents evaluated in the UFSAR; or, 2) involve different defense-in-depth echelons5;

are of significant concern.

Combining previously separate component functions can result in more dependable system

performance due to the tightly coupled nature of the components and a reduction in complexity.

If such a combination does not create a new failure mode, it is generally acceptable. In all

cases in which a licensee proposes to combine previously separate design functions in a

safety-related and/or non-safety related digital I&C, the qualitative assessment needs to weigh

the risks of possible new malfunctions against the benefits of combining the previously

separately controlled functions. Where possible, failure modes and effects analyses and

non-safety related control system segmentation analyses can be performed for the proposed

modification.

4.3.2 Quality of the Design Process and the use of Quality Standards

5 As stated in NEI 01-01, Section 5.2, a fundamental concept in the regulatory requirements and expectations for

instrumentation and control systems in nuclear power plants is the use of four echelons of defense-in-depth: 1)

Control Systems; 2) Reactor Trip System (RTS) and Anticipated Transient without SCRAM (ATWS); 3) Engineered

Safety Features Actuation System (ESFAS); and 4) Monitoring and indications.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 15 of 27

Quality of the design process is a key element that determines the dependability of proposed

modifications. Licensees employing design processes consistent with the requirements of their

NRC approved quality assurance program will result in a quality design process.

When possible, the use of applicable industry consensus standards contributes to a quality

design process and provides a previously established acceptable approach (e.g IEEE Std. 1074-2006, IEEE Standard for Developing a Software Project Life Cycle Process, RG 1.173,

Developing Software Life Cycle Processes for Digital Computer Software Used in Safety

Systems of Nuclear Power Plant). In some cases, other nuclear or non-nuclear standards also

provide technically justifiable approaches that can be used if confirmed applicable for the

specific application.

Quality standards should not be confused with quality assurance programs or procedures.

Quality standards are those standards which describe the benchmarks that are specified to be

achieved in a design. Quality standards should be documents that are established by

consensus and approved by an accredited standards development organization. For example,

IEEE publishes consensus-based quality standards relevant to digital I&C modifications and is a

recognized standards development organization. Quality standards used to ensure the

proposed change has been developed using a quality design process do not need to be solely

those endorsed by the NRC staff. The qualitative assessment document should demonstrate

that the standard being applied is valid for the circumstances for which it is being used.

4.3.3 Evaluation of Relevant Operating Experience

Operating experience relevant to a proposed digital I&C change may be credited as part of an

adequate basis for a determination that the proposed change does not result in more than a

minimal increase in the frequency of occurrence of initiating events that can lead to accidents,

or in more than a minimal increase in the likelihood of occurrence of a malfunction of an SSC

important to safety previously evaluated in the UFSAR. Differences may exist in the specific

digital I&C application between the proposed digital I&C modification and that of the equipment

and software whose operating experience is being credited. In all cases, however, the

architecture of the referenced equipment and software should be substantially similar to that of

the system being proposed. Further, the design conditions and modes of operation of the

equipment whose operating experience is being referenced also needs to be substantially

similar to that being proposed as a digital I&C modification. For example, it is important to

recognize that when crediting operating experience from other facilities, one needs to

understand what design features were present in the design whose operating experience is

being credited, and what operating conditions (e.g., ambient environment, continuous duty, etc.)

were experienced by the referenced design. Design features, which serve to prevent or limit

possible common cause failures, and references into relevant operating experience, should be

noted, and considered in the proposed design. Doing so would provide additional support for a

determination that the dependability of the proposed design will be similar to the referenced

application.

5.

Engineering Evaluations Supporting Qualitative Assessments

5.1

Introduction

This section describes approaches that could be used for conducting and documenting

engineering evaluations when they are used to support qualitative assessments. In some cases

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 16 of 27

these approaches describe efforts beyond those discussed in NEI 01-01. This information is

provided for consideration only. They do not represent an NRC position of what is necessary or

required. Use of any of this information is at the discretion of licensees.

Prior to implementing new digital I&C designs, engineering evaluations of the proposed design

need to be performed as part of the design and verification processes. Although the plant is

designed to cope with single failures of SSCs, it is possible that new sources of common cause

failure could be introduced as part of the digital I&C design, such as through the introduction of

identical software into redundant channels; through the use of shared resources; or common

hardware and software among systems performing different design functions. Therefore it is

essential that such sources of common cause failure be identified, to the extent practicable, and

addressed during the design stage as one acceptable method to support the technical basis

concluding that a proposed new design has a low likelihood of failure that is evaluated in the

subsequent licensing evaluation.

Section 3.2.2 of NEI 01-01 states:

For digital systems, the likelihood of software-related failure is minimized using

the same basic approach of controlling the design, implementation, operation,

and maintenance processes. Compliance with industry standards and regulatory

requirements coupled with tests, evaluations, and reviews is used to assure a

very low likelihood of failure. The important activities that are performed

throughout the various phases of the digital modification process and that

contribute to minimizing risk are summarized in Section 3.3 [Phases of the Plant

Modification Process] and discussed in detail in Section 5 [Additional Guidance

on Addressing Digital Upgrade Issues.] Results of these activities are then used

in the 10 CFR 50.59 process as described in Section 4 [Licensing Process and

10 CFR 50.59.] With respect to failures due to software, including common

cause failures, the key to addressing these in licensing is having performed

appropriate design, analysis and evaluation activities to provide reasonable

assurance that such failures have a very low likelihood. [emphasis added]

Such key evaluation activities may include, but are not limited to: a) the deterministic analysis of

the conformance of the design with regulatory requirements, engineering standards, and

regulatory guidance, as well as the licensing basis of the plant; b) the performance of adequate

deterministic failure analyses, including analysis of the effects of digital I&C failures at the

component-level, system-level, and plant-level; c) the evaluation of the proposed modification

for its overall dependability; and d) the deterministic evaluation of the design for the adequacy

of its ability to provide adequate defense-in-depth. It should be noted that items b), c), & d) may

be distinct analyses from a), but they are performed as a consequence of a). The qualitative

assessment framework discussed in the previous sections of this Attachment relies, in part, on

the technical bases and conclusions documented within these engineering evaluations.

Design Process Considerations

Section 3.2 of NEI 01-01 includes a figure (Figure 3-2, Using Failure Analysis to Understand

and Manage Risk) that illustrates "how failure analysis is applied during the design process to

understand and manage risk. Risk is a function of both the likelihood and the consequences of

potential failures and hazards. Depending on the combination, risk could be judged to be

negligible, non-negligible (but acceptable), or unacceptable. In practice, the design process

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 17 of 27

identifies unacceptable risks and makes adjustments accordingly, so by the time a proposed

change is ready for implementation in the plant or for NRC review, it will always lie in the region

of negligible or acceptable risk. [emphasis added]

The design process, in part, answers the following questions: a) what can go wrong? b) how

likely is it to occur?; and c) what actions are needed to address it? In Section 5.2, key

engineering evaluations are described that provide insights to whether adequate design

attributes and features have been incorporated to minimize the occurrence of system failures,

and to demonstrate sufficient system/equipment redundancy, diversity, separation, or

independence.

Section 3.1 of NEI 01-01 states:

Engineering evaluations include the collection of activities that are performed to

demonstrate reasonable assurance that the system is safe and satisfies the

specified requirements (e.g., for quality, dependability, and performance). This

may include evaluating and interpreting the results of the failure analysis, design

verifications, software V&V, and review of vendor software design and

development processes. Where appropriate, analyses of overall

defense-in-depth and diversity of the plant may be warranted to demonstrate the

ability to cope with common cause failures.

Section 4.1.1 of NEI 01-01 states that two key elements of the engineering evaluations are

evaluating the dependability of the digital equipment and its associated software, and analyzing

potential failures. One of the key considerations in licensing digital upgrades is determining

whether failures due to software are as likely as other potential failures addressed in the

UFSAR. This issue is addressed by establishing reasonable assurance that such failures are

unlikely, based on the engineering evaluations performed as part of the design process.

5.2 Key Engineering Evaluations

Section 4 Engineering Evaluations of Appendix B, Outline for Documenting 10 CFR 50.59

Screens and Evaluations, of NEI 01-01 provides guidance for documenting why the proposed

digital I&C modification as designed is considered appropriate for the application. This

Appendix section describes types of engineering evaluations that may be used to provide

justification as to why the proposed design is appropriate. These include an evaluation of the

design for conformance with applicable design criteria, regulatory requirements and industry

standards.

The analyses described below represent acceptable methods for performing engineering

evaluations supporting a qualitative assessment. One result of performing these evaluations is

to provide insights as to whether a proposed digital I&C design modification may need to be

enhanced with the inclusion of different or additional design attributes. Such different or

additional design attributes would serve to prevent the occurrence of a possible software CCF,

reduce the likelihood of occurrence of a possible software CCF, or mitigate the effects of a

software CCF that can occur.

5.2.1 Failure Analyses

1

2

3

4

Page: 25

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:27:04 AM

This contradicts your definition of "sufficiently low" which requires the failure likelihood to be comparable to failures not considered in the FSAR".

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:26:09 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:29:00 AM

The ability to mitigate the malfunction is completely different than the determination of likelihood.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:27:52 AM

RIS 2002-22 Supplement 1, Attachment

Page 18 of 27

As stated in Section 5.1 of NEI 01-01, a digital I&C modification failure analysis is a part of the

design process that should be performed as part of plant design procedures and should be

documented as part of the design process. The performance of such a deterministic failure

analysis of a proposed digital I&C modification is one acceptable method for providing insights

regarding the possible failure modes of the modification that are needed to support such

licensing evaluations, which are typically performed later in the modification process. The

failure analysis provides, in part, the insights needed to determine if a proposed digital I&C

modification is vulnerable to possible software CCF such that the resulting design could reduce

redundancy, diversity, separation, or independence, which could result in more than a minimal

increase in the likelihood of occurrence of accidents or malfunctions. Such deterministic failure

analyses provide feedback to the designers regarding effects of possible failures of the

proposed digital I&C modification on plant systems so that the designers can make

determinations as to whether there is a need to further modify the design to address any design

issues that are uncovered. For example, a failure analysis may reveal that due to the adequacy

of design features already included within a proposed design, the possible occurrence of

failures due to a software CCF vulnerability is considered to have such a low risk that the

proposed design is considered to be adequate.

NEI 01-01 Section 5.1 states, in part, that the failure analysis should include the following

elements..:

Identification of potential system-level failure and undesirable behavior (which

may not be technically failures) and their consequences. This includes

consideration of potential single failures as well as plausible common cause

failures.

Identification of potential vulnerabilities, which could lead to system failures or

undesirable conditions.

Assessment of the significance and risk of identified vulnerabilities.

Identification of appropriate resolutions for identified vulnerabilities, including

provide [sic] means for annunciating system failures to the operator.

NEI 01-01 Section 5.1 also states:

A variety of methodologies and analysis techniques can be used in these

evaluations, and the scope of the evaluations performed and documentation

produced depends on the scope and complexity of the upgrade. The analysis

maintains a focus at the level of the design functions performed by the system,

because it is the effects of the failure on the system and the resulting impact on

the plant that are important. Failures that impact plant safety are those that

could: prevent performance of a safety function of the system, affect the ability of

other systems to perform their safety functions, or lead to plant trips or transients

that could challenge safety systems.

NEI 01-01 Section 5.1.1 states, in part,

1

2

Page: 26

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:31:46 AM

Clarify that this means risk comparable to other failures that are not considered in the FSAR and distinguish this from risks that do not reach this level and

therefore require further analysis of the plant level effects.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:30:54 AM

RIS 2002-22 Supplement 1, Attachment

Page 19 of 27

It is useful at this stage to review the UFSAR to determine how failures of the

affected system are described and analyzed. An understanding of the UFSAR-

described failures and their results is needed to support the 10 CFR 50.59

evaluation discussed in Section 4 [Licensing Process and 10 CFR 50.59.] If the

plant design change introduces any failures that cause results different from

those analyzed in the UFSAR, then a license amendment may be required.

The introduction of new digital designs having sources of CCF in common with other plant

non-safety related designs that have been assumed in the safety analyses to remain functional,

may result in the plant being put into a condition for which it has not been analyzed. This is

particularly the case when such common sources of CCF also are subject to common triggers.

An adequate failure analysis is one that includes a sufficient level of detail to enable licensees to

make a determination as to the possibility for and likelihood of potential new failures that could

be introduced by a proposed modification. This includes an understanding of the operations of

any external connections of the modified SSC(s) to and from other SSCs, as well as an

understanding of how identical hardware and software, power supplies, human-machine

interfaces, etc. may have been employed elsewhere in the plant, such that after the modification

has been implemented, there remains a possible commonality in vulnerabilities to the same

common cause sources and their triggers. NEI 01-01, Section 4.1.2 states that additional

factors that can contribute to the determination that the likelihood of software CCF is acceptably

low include:

Simple software architecture, few inputs/outputs, well-defined failure states, built-

in fault tolerance (see Section 5.3.2). Systems that are sufficiently simple can

have well defined failure modes and tend to allow for more thorough testing of all

input and output combinations than complex systems. The simplicity of the

digital equipment itself and of the application should be considered.

Modifications that employ effective design attributes and features such as internal or external

systematic diversity help to ensure that possible vulnerabilities do not result in CCFs. The

design of such systems are deemed to be adequate.

5.2.2 Dependability Evaluation

The dependability of a design is described in NEI 01-01 (Page 2-3) as a broad concept

incorporating various characteristics of digital equipment, including reliability, safety, availability,

maintainability, and others. Section 4.1.2 of NEI 01-01 states:

To determine whether a digital system poses a significant risk of software failure,

the factors that contribute to its dependability (or likelihood of failure) and quality

need to be evaluated.

NEI 01-01, Section 4.1.2 further states that additional factors that can contribute to the

determination that the likelihood of software CCF is acceptably low include:

The maturity of the product and substantial relevant history of satisfactory

operation in similar application (including operating experience at other plants

and in other industries). Additional confidence is gained if the same equipment

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 20 of 27

and application program have been used successfully in other nuclear plants or

other similar applications.

Technical evaluation in combination with deterministic design measures can be used to make a

determination as to whether a proposed I&C modification is sufficiently dependable. However,

there might not be clearly applicable consensus methods for accurately quantifying the reliability

of software. Therefore, it may be necessary to use engineering judgment as to whether the

proposed design is still sufficiently dependable in its ability to perform its required functions

while significantly limiting, or avoiding the introduction of possible new sources of software CCF.

The dependability evaluation relies on some degree of engineering judgment to support a

conclusion that the digital modification is considered to be sufficiently dependable. When

performing a dependability evaluation, one acceptable method is to consider: (1) inclusion of

any deterministically-applied defensive design features and attributes, (2) conformance with

applicable standards regarding quality of the design process for software and hardware, and (3)

relevant operating experience. Although not stated in NEI 01-01, staff believes that judgements

regarding the quality of the design process and operating experience may supplement, but not

replace the inclusion of design features and attributes.

For proposed designs that are more complex or more risk significant, the inclusion of design

features and attributes that: serve to prevent vulnerabilities to software CCF, significantly reduce

the possible occurrence of software CCF, or significantly limit the consequences of such

software CCF, should be key considerations for supporting a sufficiently dependable

determination. Design features maximizing reliable system performance, to the extent

practicable, can be critical in establishing a basis for the dependability of complex or risk

significant designs.

Section 5.1.3 of NEI 01-01 states that Judgments regarding dependability, likelihood of failures,

and significance of identified potential failures should be documented. It may be challenging

to demonstrate sufficient dependability using solely the quality of the design process.

5.2.3 Defense-in-Depth Analyses

If there are specific licensing basis discussions for diversity or defense-in-depth applicable to

the affected design function they must be explicitly addressed. For example, as discussed in

Section 5.2 of NEI 01-01, a defense-in-depth and diversity (D3) analysis is required when the

trip logic and actuation portions of the RTS and/or ESFAS are modified with digital equipment.

Although a formal D3 analysis is not required for non-protection systems, a defense-in-depth

analysis should also be considered for complex digital modifications of non-protection systems to

determine the impact of any new potential vulnerabilities to common cause failures due to the

introduction of shared resources, common hardware and software, or the combination of design

functions of systems that were previously considered to be independent of one another. If a new

potential common cause vulnerability has been introduced, the defense in depth analysis can

identify whether there may be diverse manual or automatic means that can perform the same or

different functions or whether additional design features (e.g., internal diversity) are appropriate

for incorporation.

Possible software CCFs that have been identified in the failure analysis (and not eliminated from

consideration based on the dependability evaluation) can be assessed to determine whether

1

2

Page: 28

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:36:46 AM

BTP 7-19 says a D3 analysis is required for "safety systems" not just protection systems. A RIS cannot change current Staff policy.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:36:08 AM

RIS 2002-22 Supplement 1, Attachment

Page 21 of 27

adequate diversity and defense-in-depth will remain after the digital I&C modification is

implemented. Possible means, for ensuring adequate diversity and defense-in-depth will

remain at the system or plant level, can include: (a) the use of design attributes to achieve

adequate diversity, (b) the crediting of available high-quality, non-safety related, but

independent systems, or (c) manual actions that are already analyzed and credited in the

UFSAR safety analysis.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 22 of 27

Section 5.2.1 of NEI 01-01 states:

The cumulative effects of a series of upgrades or modifications should also be

considered in the determination of whether a defense-in-depth and diversity

analysis is performed. For any change to the plant, consideration should be

given to the effects the change may have on diversity and defense-in-depth for

RTS/ESFAS functions. If the change would affect the diversity and defense-in-

depth of the RTS/ESFAS functions, then the analysis should be performed.

Also, if other I&C systems, including ATWS and other non-safety systems, are

being upgraded to digital in plants where digital upgrades to RTS and/or ESFAS

have already been done, prior defense-in-depth and diversity analyses should be

reviewed. If the I&C system under consideration was credited in the prior

analysis as providing backup, then the replacement digital equipment should be

diverse from that used in the protection systems. NUREG-6303 provides

guidance on methods that can be used to assess the diversity of digital systems.

For RPS and ESFAS, BTP 7-19, Revision 7, Section 1.9 states that many system design

attributes, testing, procedures, and practices can contribute to significantly reducing the

probability of CCF occurrence. However, there are two design attributes, either of which is

sufficient to eliminate consideration of software based or software logic based CCF. For other

systems, different design attributes and testing can be used if: (1) technically acceptable, (2)

suitable for the application, and (3) defensible. Properly implemented, these different attributes

could serve to significantly reduce uncertainty and establish that the risk is determined

negligible or acceptable.

To simplify and to facilitate the D3 analysis, a CCF may be assessed using best-estimate

methods and realistic assumptions. However, such methods are not appropriate for use in

evaluating the effects of failures when performing 50.59 evaluations. Unless already

incorporated into the design and licensing basis, best-estimate methods cannot be used for

evaluating different results than those previously evaluated in the UFSAR.

A defense-in-depth evaluation may reveal any direct or indirect impacts on interfaces with

existing plant SSCs. This type of evaluation may reveal there are existing backup capabilities

that could serve to mitigate any negative effects of possible low likelihood failures that could be

introduced through the proposed design of the modification.

5.3 Appropriate Resolution to Identified Failures

If a postulated common cause failure of a digital modification has been provisionally determined

to be not sufficiently low, in general, the following options can be considered:

-

seek NRC approval first, pursuant 10 CFR 50.90 for the modification;

-

satisfy 10 CFR 50.59 criteria using an alternative approach6; or

-

redesign the proposed modification so that a sufficiently low likelihood of failure conclusion

could be made.

6 An example of an alternative approach is a deterministic conclusion that failure likelihood is less than comparable

failures in the UFSAR.

1

2

3

4

5

6

Page: 30

Number: 1 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:39:34 AM

Number: 2 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:39:13 AM

These other attributes can be used when accompanied by Staff review. Now you are changing the Staff policy to allow these other attributes to be used without

Staff review and without additional endorsed Staff guidance.

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:42:46 AM

You are making a statement with inadequate justification. "Best estimate" methods are used in most, maybe all, FSARs for all beyond design basis events. SECY 93-087 and BTP 7-19 define CCF with concurrent accidents as a beyond design basis event. Now, you are using this RIS to change NRC policy.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:40:21 AM

Number: 5 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 11:44:21 AM

This is not an alternate approach. It is your definition of "sufficiently low"

Number: 6 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:43:50 AM

RIS 2002-22 Supplement 1, Attachment

Page 23 of 27

NEI 01-01 Section 5.1.4, states, in part, with regard to appropriate resolution for identified

potential failures, the following:

Modify the design or apply greater emphasis to appropriate parts of the design

process to address the potential failure. If the failure is considered significant

because of a lack of confidence (or difficulty in achieving reasonable assurance)

in a portion of the design or in a particular software element in the design, then

one option may be to apply additional design verification or testing activities.

This additional design verification or testing could develop the needed confidence

and achieve reasonable assurance that the likelihood of the failure is such that it

is no longer considered a significant risk [sufficiently low]. Alternatively, the

design itself may be modified to either preclude the failure (e.g., make it fail safe

for this particular failure) or add internal backups in the design, such as

redundancy or diversity.

Redesigning a proposed modification to include additional design attributes, design features (e.g.,

internal or external systematic diversity) and/or additional design verification and testing activities

is a recommended option for licensees to consider if the licensee wants to implement the

modification without prior NRC approval. Redesigning could also help ensure potential new

failure modes and misbehaviors are adequately addressed in the design. Providing additional

design verification and/or testing activities on software or software-based elements of a proposed

design that demonstrates high reliability can be a key consideration in demonstrating the overall

dependability of the proposed modification and that the modification will exhibit a low likelihood of

failure.

NEI 01-01 Section 5.1.4, also states, in part, with regard to appropriate resolution for identified

potential failures, the following:

Rely on existing backup capability offered by existing systems to address the

failure - other equipment or systems that provide alternate ways of

accomplishing the function or otherwise provide backup for this failure. This may

include operator action if there is adequate information and time available for the

operator to act, and with appropriate procedures and/or training.

Supplement the existing backup capability such that the failure is adequately

addressed. This could include improving the ability to detect the failure

automatically so the repair response will be timely, improving procedures and

training for the operators to mitigate the effects of the failure, or providing

additional backup capability (e.g., manually operated switches for critical

functions and procedural guidance for their use), so that the resulting risk is

insignificant.

Reliance on existing backup capability that has been evaluated and documented as part of a

plants licensing bases is one acceptable means to address postulated failure modes and

undesirable behaviors of a proposed digital I&C modification. Similarly, re-design of existing

backup capabilities is also considered acceptable, as a means to address failures that can be

introduced by the modification. In cases where reliance on back-up capability or operator actions

is not part of the plants licensing basis, prior NRC approval would likely be required.

1

2

3

4

Page: 31

Number: 1 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 12:01:52 PM

"Best estimate" methods facilitate crediting backups. Without "best estimate" methods backups cannot be credited because they will never achieve the same

performance (e.g. response time, design basis margin to critical safety function limits) as the original system.

Number: 2 Author: KenSc

Subject: Highlight

Date: 01/24/2018 11:59:40 AM

Number: 3 Author: KenSc

Subject: Sticky Note Date: 01/24/2018 12:03:16 PM

This is not an economical means nor is it likely to show equivalent design basis results. This is why "best estimate" methods are needed.

Number: 4 Author: KenSc

Subject: Highlight

Date: 01/24/2018 12:02:23 PM

RIS 2002-22 Supplement 1, Attachment

Page 24 of 27

5.4 Documentation of Engineering Evaluations

The documentation of adequate engineering evaluation outlines the identification of potential

new failure modes or undesirable behaviors on the design function of the modified SSC(s) or

other SSC(s), the possible effects of these vulnerabilities on plant safety, and the design

features or operating provisions that are being put into place to prevent and/or mitigate their

occurrence as well as descriptions of the types of engineering evaluations performed.

Documenting an adequate engineering evaluation of appropriate resolutions to the identified

vulnerabilities permits a clear understanding by designers and future evaluators of the potential

effects of the vulnerabilities to plant safety and operations.

Table 2 below provides a suggested outline for documentation to support NEI 01-01 Appendix B

guidance for engineering evaluations that supports and forms the basis for qualitative

assessments for safety-related and non-safety related SSCs, as applicable. Although not

required, licensees may use Table 2 as an example basis for the level of detail, types of

evaluations, and documentation such that technical conclusions reached through the

engineering evaluations can be verified independently. Implementation details are at the

discretion of the licensee, consistent with the licensees procedures.

Engineering Evaluations and Documentation for Non-Safety Related SSCs

With regard to engineering evaluations of non-safety related SSCs, there may be differences in

the level of detail, types of analyses and documentation based upon the non-safety related

SSC(s) being modified and the characteristics of the design within the proposed modification.

Adequate engineering evaluation for non-safety related SSCs helps ensure:

Postulated new failure modes do not result in concurrent failures in shared resources,

common hardware and software, or communications among two or more different

non-safety related SSCs such as the combining of different design functions that were

previously separate (e.g. Feedwater and Turbine Bypass controls).

Postulated new failure modes do not exist that could propagate to two or more different

non-safety related SSCs such that the effect could place the plant into an unanalyzed

condition based upon the plants existing safety analysis.

Identified vulnerabilities have been adequately addressed (e.g. specific design features,

quality of the design processes or demonstration of relevant operating experience).

Documentation for non-safety related modifications should be consistent with the licensees

procedures. Licensees need not prepare formal qualitative assessments for every proposed

digital modification to non-safety related SSCs where the nature of the proposed modification

does not have the characteristics described above (i.e., with the potential to impact assumptions

in the safety analysis), consistent with requirements of licensee procedures.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 25 of 27

Table 2Example - Engineering Evaluation Documentation Outline

to support a Qualitative Assessment

Topical Area

Description

Step 1

Identification

Describe the full extent of the SSCs to be modifiedboundaries of the

design change, interconnections with other SSCs, and potential

commonality to vulnerabilities with existing equipment.

What are all of the UFSAR-described design functions of the

upgraded/modified components within the context of the plant

system, subsystem, etc.?

Describe what design function(s) that were provided by the

previously installed equipment are affected and how those same

design functions will be accomplished by the modified design. Also

describe any new design functions to be performed by the modified

design that were not part of the original design.

What assumptions and conditions are expected for each associated

design function for either safety-related or power generation

purposes? For example, the evaluation should consider both active

and inactive states, as well as transitions from one mode of

operation to another.

Step 2Identify

potential

vulnerabilities: failure

modes and

undesirable behavior

Consider the possibility that the proposed modification may have

introduced potential single failures and plausible common cause failures.

What are potential new undesirable behaviors of the modified

system? A key consideration is that undesirable behaviors may

not necessarily constitute a SSC failure, but a mis-operation. (e.g.,

spurious actuation)

Consider errors or failures as a result of hardware, software

including operating systems, application software, combining of

functions onto the same controller(s), introduction of shared

resources, or common hardware and software, etc.

Are there interconnections or interdependencies among the

modified SSC and other SSCs? This could be facilitated by use of

digital communications, modification of control logic, common

usage of hardware/software, etc.

Are there potential new sources of common cause failure being

introduced that are also subject to common triggering

mechanisms with those of other SSCs not being modified?

What potential failure modes or undesired behaviors may be

introduced as a result of the modification (e.g. new operator

interfaces, introduction of digital communications)

Step 3Assess the

effects of the

identified

vulnerabilities

Could the possible new failure mode or undesired behavior lead to

a plant trip or transient?

Could the possible new failure mode or undesired behavior

prevent performance of a safety function of the SSC(s) being

modified?

Can the possible new failure mode or undesired behavior affect

the ability of other SSCs to perform their safety function?

Could the possible new failure mode of the SSC, concurrent with

a similar failure of another SSC not being modified but sharing a

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 26 of 27

Table 2Example - Engineering Evaluation Documentation Outline

to support a Qualitative Assessment

Topical Area

Description

common vulnerability and triggering mechanism, place the plant

into an unanalyzed condition, or into a condition for which the

other SSC was assumed to function as expected for a particular

event analyzed in the existing safety analysis?

What are the results of the postulated new failure(s) of the

modified SSC(s) compared to previous evaluation results

described in the UFSAR?

Does the possible new failure mode or undesired behavior affect

the ability of the modified SSC or other SSCs to provide its design

function (as defined in NEI 96-07)?

Step 4Identify

appropriate

resolutions for each

identified vulnerability

What actions are being taken (or were taken) to address significant

identified vulnerabilities?

Are further actions required?

Re-design in order to add additional design features or attributes?

Credit existing backup capability?

Is there means to annunciate the postulated failure or misbehavior

to the operator?

Step 5Rationale

Provide a brief description of why the identified resolutions described in

Step 4 of this table adequately address the identified vulnerabilities in

Step 3 of this table.

Step 6

Documentation of

Available Evidence

An acceptable documentation describes each of the resolutions

needed to address the potential low likelihood failure modes

identified in Step 2 of this table

Conformance to regulatory requirements (e.g. General Design

Criteria and Regulatory Guides) and Industry consensus

standards, etc. that are met or credited. (e.g., seismic, EMI/RFI,

ambient temperature, heat contribution, etc.), as applicable.

Quality of the Design Processes employed in such as within the

software life cycle development (e.g., verification and validation

processes used as evident in a traceability matrix, quality

assurance (QA) documentation, unit test and system test results,

etc.,),

Description of relevant Operating History (e.g., platform used in

numerous applications worldwide, etc. with minimal failure history,

etc.)

Description of how the design features/attributes are credited

towards resolution of the vulnerabilities identified (e.g., internal

design features within the digital I&C architectures such as self-

diagnostic and self-testing features or physical restrictions

external to the digital I&C portions of the modified SSC(s)),

defense-in-depth (e.g., internal systematic diversity, internal back-

up capability, etc.)

Engineering evaluations performed such as failure analysis,

dependability analysis, defense-in-depth analysis, etc.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 27 of 27

Table 2Example - Engineering Evaluation Documentation Outline

to support a Qualitative Assessment

Topical Area

Description

Step 7Conclusion Apply the results of the engineering evaluation to the qualitative

assessment to respond to the 50.59 evaluation questions as appropriate.

6. Qualitative Assessment Documentation

NRC endorsed guidance for documenting 10 CFR 50,59 evaluations to meet the requirements

of 10 CFR 50.59 (d) is provided in both NEI 96-07, Revision 1 in Section 5.0, Documentation

and Reporting and NEI 01-01, Appendix B. Both of these documents reiterate the principals

that documentation should include an explanation providing adequate basis for the

conclusion so that a knowledgeable reviewer could draw the same conclusion.

Considerations and conclusions reached while performing qualitative assessments supporting

the evaluation criteria of 10 CFR 50.59, are subject to the aforementioned principles. In order

for a knowledgeable reviewer to draw the same conclusion regarding qualitative assessments,

details of the considerations made, and their separate and aggregate effect on any qualitative

assessments need to be included or clearly referenced in the 10 CFR 50.59 evaluation

documentation. Documentation of referenced documents includes the document name and

location of the information within any referenced document.

If the qualitative assessment categories discussed in Section 4.3 are used, each category would

be discussed in the documentation including positive and negative aspects considered,

consistent with the examples provided in Table 1. In addition, a discussion of the degree to

which each of the categories was relied on to reach the qualitative assessment conclusion

would be documented.

This page contains no comments

RIS 2002-22 Supplement 1, Attachment

Page 28 of 27

SUBJECT: NRC REGULATORY ISSUE SUMMARY, CLARIFICATION ON ENDORSEMENT

OF NUCLEAR ENERGY INSTITUTE GUIDANCE IN DESIGNING DIGITAL UPGRADES IN

INSTRUMENTATION AND CONTROL SYSTEMS, SUPPLEMENT 1 TO RIS 2002-22,

DATE: January XX, 2018

This page contains no comments