05000296/LER-1980-019-03, /03L-0:on 800527,during Normal Operation, Discovered Drywell Sump Flow Transmitter FT-77-16 Had Output Signal Shift.Cause Unknown.Transmitter Replaced & Instrument Loop Calibr

From kanterella
(Redirected from ML18025A937)
Jump to navigation Jump to search
/03L-0:on 800527,during Normal Operation, Discovered Drywell Sump Flow Transmitter FT-77-16 Had Output Signal Shift.Cause Unknown.Transmitter Replaced & Instrument Loop Calibr
ML18025A937
Person / Time
Site: Browns Ferry 
Issue date: 06/25/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18025A936 List:
References
LER-80-019-03L-01, LER-80-19-3L-1, NUDOCS 8007010377
Download: ML18025A937 (4)


LER-1980-019, /03L-0:on 800527,during Normal Operation, Discovered Drywell Sump Flow Transmitter FT-77-16 Had Output Signal Shift.Cause Unknown.Transmitter Replaced & Instrument Loop Calibr
Event date:
Report date:
2961980019R03 - NRC Website

text

u.

FII<l LLAIIIIE UI'LAftJRY COMMIb',slOI Q'.ICENSE NUtJIIEB 80

~sltE s u ~ ~<<

~ ti<

P77) j

~CENSEE EVENT REDaLI'I'05NTR)L BLOCK: L Qi If'LEASE PRINT OR TYPE I'LLREQUIRED INFORMATION)

I 6

[iiOI A

L 8

R F

Q2L

~0~ 0 7

8 9

LICENSEE CODE 14 15 25 ZG L!CENSE TYPE JO 57 Cnr 58 (CON'T

(~o<

<a<<ac< ~LQs 0

5 0

0 0

2 6

0 6

2 QB DOCKET NUIJBER GB 69 EVENT DATE 74 75 REPORT DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES QID During normal operation the drywell sump flow transmitter FT-77-16 was discovered

~D3

~O4 to have an output signal shift.

Reference T.S. 3.6.C.1.

No redundant systems.

No danger to health or safety of public.

Previous occurrence:

259/73007.

~OS

~os

~cs 7

8 9

SYSTEh!

CAUSE

CAUSE E,oh!P VALVE CODE CODE SUBCODI.

COMP'INENT CODE SUPCODL SUBCODE

~OB 0 Q 8 Q

~EQ<2 1

N 8

T R

U Q

~TO<5

~ZQs 7

8 9

'10

'l I2 13 I8 II\\

20 SEOUEI'ITIAL OCCURRENCE REPORT BEVISIDN LER<RO EVENT YEAR REPORT NO.

CODE TYPE NO On nFr<on<

~80

~

~01 9

~m

~03

~L

~0 21 22 23 24 26 Zt 28 29 30 31 32 ncr!Dtt FurUBE EFFECT SHU'f DO'IYN ATTACHMENT N"BD4 PRIIJE COIJ.

COEJPONL!JT Tnt'eN ACT!ON 0>> I LANr hIETHOD HOURS +22 SUBhlITTED FOR71bL!B.

SIIPPLIEB hIANUPACTEIBEI<

~CO<a ~ZQ<o

~ZQze

~ZQ2<

0 0

0 0

~Y Q22

~NO<

~L Q25 G

0 8

0 J.

33 34 35 3G 37 40 41 42 43 44 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q21 o

Flow transmitter, FT-77-16, suffered a zero shift each time sum um s were run.~

Cause of shift.unknown.

GE t e

GE5!AC Nodal 555111BDAA3AAA flow transmitte w

replaced and instrument loop calibrated.

No recurrence control lanned due to low incident rate.

I 4

1 8

9 FnCILITY STAIUS

'E POYIEfl OTHER STATUS

~<5 E

s

~~~

0 Q25 1,8 9

10 12 I1 44 ACTIVITY CONTENT REI.EASED OF fIELE'ASE AVAUNTOF ACTIVII Y 3'2 6

~

Q33 ~2'34 7

8 9

10 11 44 uf BSO(dNEL FXPOSUIIES NUt/BEII TYPE'ESCIIIPTION L00000 JQ2< ~ZQ2<<L NA I

8 9

I I 12 13 peBSDNNEL INJURIES 4 <a NA LOCATIONOF RELEASE t IE TROD OF DISCOVERY D2SCOVERY DESCRIPTION

(~AQ2<

Operator observed 4G 8<5 811 P.I2 7

8 9

11 12 7

8 I.OSS OF OR Onlnnre To FACILITYQ43 IVI'E

DESCRIPTION

Z Q42 NA, 9

10 ruoucl T Y DESCRIPTION ~4

~N. Q<<

NA 800'F 02 0 NAME OF PRFPARER 0

77 PHONE:

68 69 NRC USE ONLY Fi'<<1 E20 I<

iC 4

Tennessee Valley Authori Bro.vns Ferry Nuclear Plant I.ER SUPPI E~iIENTAL INFORMATION N<<m AV--tv BV 15. 2 1/10/79 BFRO 50 296 / 8019 Technical Specification Involved 3.

~

~ 1 Repor ted Under Technical Specification

6. 7.2.b(2)

Date of Occurrence 5/

/

Time of Occurrence

'Unit Identification and Descri tion'of Occurrence:

Drywell sump flow transmitter FT-77-16 was discovered to suffer a zero shift each time the sump pump was'un'.'onditions Prior to Occurrence:

Unit 1 8 97%

Unit 2 8 98%

Unit 3 8 99%

Action specified in the Technical Specification Surveil.'ance Requirements met Sump pumps locked out until flow transmitter returned to service.

~Ayarent Causa of Occurrence:

Cause of zero shift unknown.

Anal sis of Occurrence:

There was no damage to plant equipment.

There was no activity release, no personnel exposure or injury and no danger to-the health or safety of the public.

Corrective Action

The tran'smitter was replaced and loop calibrated.

Failure Data:

BFRO-50-259/73007

~Retention:

criod - Lifetime; Responsibility - Admn>istrative Supervisor

'":Revision:

l' t r

'V, I

C