DOCKET' 05000400 05000401 05000402>>

05000403'OTES'j.

REGULAT INFORMATION DISTRIBUTIO STEM (RIDS)

ACCESSION NBR:ef03230745 DOC.DATE~ sf/03/fe NOTARIZED: No FACIL::SO 400 Shear on Har r)s Nuclear Power Planti Unit ii Carolina'0;,401 Shear on Har ris Nuclear Powe'r I Pl anti Unit* 2'i Car ol-ina S0.402 Shearon Har r)s Nucle'ar Power Planti Unit: 3i Cai'ol)na 50 403 Shear on Harl,is-Nuclear Power: Plant'i Uni.t 4i Carol ina-AUTH~ NAME",

'UTHOR AFF ILI'ATION CHIANGI'iN,J, Caro'line Power>>

L Light>> Co, RECIP ~ NAME),

RECIPIENT AFFILIATION O'REILLYiJ'eP,.

Region 2i Atlantai Office" of -the Dir actor

SUBJECT:

= Final deficiency rept. ret omission of pr otective'oating 8

existence of damaged-,coating on Unit 1. containmegt.,l)ner:

duel to concr ete') acement" past requir ed point'Inspcr i ter,'iai FCR AS 287iwritteh to allow coating w/o surface pre>aration; DISTRIBUTION CODE,: BOi98'OPIES RECEIVED:LTR J "ENCL

'IZE:-

'ITLE':'onstruction Deficiency Repor t>> (fOCFRSO.SSE')

RECIPIENT'D CODE/NAMEI ACTION:

A/D L'ICENSNG 04 RUSHBROOKiM ~

06'NTERNAL:.

ASLBP/ Ji'e HARD EDO L STAFF 19 HYD/GEO BR 22'ZC>

QUAL BR 12',

NRC PDR 02",

P

'REV 13 EG FILE'1 DRDS DEV 21 COPIES LTTR ENCL 1

1 1

1 1

1 1

1, 1 1

1 1

1 1

1 1

1 1

1 RECIPIENT'D CODE/NAME>>.

YOUNGBLOODiB 05 AULUCKiR ~ '7 D/DIR HUM FAC15 EQUIP QUAL',BR11 ILES 09 MPA 20 OELD'1 QA BR

, 14 RUTHERFORDi> ~ IE" COPIES LTTR ENCL<

1 1

1 1>>

1 1

1 1"

1 fl 1

1-f f>>

1 1

1 1

EXTERNAL:= ACRS NSIC'6'8 ie 1

1 LPDR 03 TOTAL'UMBER OF COPIES REQUIRED ~

LTTR 37 ENCL'7

0 1

0

FQ.e:

SH N-2/18 Xtem 49 C~L Carolina Power 8 Light Company Raleigh, N.C. 27602 March 16, 1981 Mr. James P. O'Reilly United States Nuclear Regulatory Commission Region II 101 tfarietta Street, Northwest Atlanta, Georgia 30303

+~ <<$p l~i,')

SHEAROH HARRIS NUCLEAR POWER PLANT UNITS 1, 2, 3 AHD 4 DOCKET NOS. 50-400, 50-401, 50-402 AHD 50-403

,OMXSSIOH OF PROTECTIVE COATXHG AHD EXISTENCE OF DAMAGED COATIHG OH TIiE UNIT 1 CONTAIN.'KVZLX~

(OPEN XT&f 400/80-23-10

Dear ~Lr. O'Reilly:

Attached is the anal 10CFR50.55(e) report on the subject deficiency which describes the problem and the corrective action taken to accomplish resolution.

With this report, Carolina Power

& Light Company considers this matter closed.

H you have any questions regarding this matter, please do not hesitate to contact me.

NJC/at (6983)

Attachment cc:

Mr. G. Maxwell W/A Hr. V. Stello (2) W/Ag Yours very truly, P i~irlal Sighted By i'. 3. Chiangi N. J. Chiangi Manager Engineering

& Construction Quality Assurance/Quality Control

0

~~

~

Iy -<-< C P

,p

~. ~ )

<<o l

Carolina Power

& Light Company Shearon Harris Nuclear Power Plant Unit 1 Final Report March 16, 1981

'I Reportable Under 10CFR50.55(e)

Prepared by:

Carolina Power

& Light Company

SUBJECT 10CFR50.55(e)

Reportable Item Shearon Harris Nuclear Power Plant (SHNPP).

Omission 'of Protective Coating and Existence of Damaged Coating on the Unit 1 Containment Liner.

DESCRIPTION On or about September 16, 1980, it was noticed by site inspection personnel that a section of the Unit 1 Containment Liner plate, adjacent to the refueling slab (a two inch gap exists in this area between the liner plate and the slab) had not received the final nuclear coatings required, prior to placing the concrete slab.

In addition in some areas the coating that existed (prime coat only) had been damaged and also had not been repaired.

The section of liner plate in question is approximately five (5) feet in height and sixteen (16) feet long.

SAFETY IMPLICATIONS I

The liner plate in the containment building furnishes no structural value for the building, but rather serves as an impervious barrier for containing any possible type of radioactive contamination/release that may exist inside the building.

For this reason, the liner plate has to be protected against corrosion.

Considering the worst possible environment that could exist inside the containment for an extended period (30 to 40 years) the possibility existed that the liner plate, without the protective coating, could have had a corrosion rate which would cause its wall thickness to fall below the minimum allowable.

THE CAUSE OF THE PROBLE'4/PREVENTATIVE ACTION The cause of the problem was that the concrete placement proceeded past the point where the liner coating could be applied properly as a result of inspectors not being fully aware of the coating requirements of the"liner plate.

The Inspectors saw steel that had a painted surface, although sections were acceptable, and did not really understand what requirements were involved in coating the plate.

Inspection personnel have been advised of the function of the liner plate and the manner in which it must be coated.

CORRECTIVE ACTION FCR-AS-287 was written to allow the coating to be applied without any type of surface preparation and the second prime and top coats to be applied using best possible technique available since there was only a 1 1/2" to 2" gap in which to work.

Inspection criteria would be waived as a result of the location.

Since the liner plate already had a prime coat, which was in fair condition, the Engineer approved this request.

A special spray nozzle (1 1/4" diameter with a 360 application)'as procurred to aid in the coating.

An attempt was made to scarify the surface to improve paint adhesion (this consisted of using steel brushes and a special sandblasting tool that was 1 3/4 inches in diameter).

Not all the surface was scarified but what could be reached was.

After preparing the

surface, environmental conditions were established around the area and the coating operation proceeded and has now been satisfactorily completed.

DETAILED REFERENCE The following detailed references are on file at the project site:

(1)

Letter to Forehand from Lucas (2)

Letter to Distribution from Chiangi (3)

Letter to Forehand from Lucas (4)

Letter to Forehand from Lucas (5)

Letter to O'Reilly from Chiangi (6)

Letter to O'Reilly from Chiangi (7)

FCR-AS-287 10/20/80 10/20/80 ll/12/80 ll/14/80 11/14/80 2/27/81 10/07/80