REGULATO 'NFORMATION DISTRIBUTIO

'CKSSION NBR:8009100465 DOC ~ DATE; 80/08/19 NO FACIL:50-400 Shearon Harrjs Nuclear Power Planti 50-401 Shearon Harrjs Nuclear Power Planti 50-002 Shearon Harris Nuclear Power Planti 50-403 Shearon Harris Nuclear Power Planti AUTH.NAME AUTHOR AFF ILI ATION CHIANGIPN ~ J.

Carolina Power 8 Light Co.

REC IP ~ NAME RECIPIENT AFFILIATION N

S TEM (R IDS)

TARIZED:

NO Unit ii Carolina Unjt 2i Caroljna Unit 3i Carolina Unit 4i Car ol ina DOC 000~

o 01 05000002 05000003

SUBJECT:

Deficiency rept re potential deficjency re use of insufficient preheat. in, field welding of Seismic I hangers.,

Item is still under investigation to determine reportability per 10CFR50.55e.Evaluation will be completed by 800905.

DISTRIBUTION CODE:

BOI90 COPIES RECEIVED:LTR &ENCL /SIZEE TITLE: Construction Deficiency Report (10CFR50.55K)

NOTES'ECIPIENT IO CODE/NAME ACTION:

A/0 LICENSNG 04 RUSHBROOKEM ~

06 INTERNAL: AD/RCI/IE 17 ASLBP/J ~ HARD DIREHUM FAC Slo EQUIP QUAL" BR11 LIC QUAL BR 12 NRC POR 02 PRO ST REV 13 01 STANDROS DEY 21 COPIES Lfl'TR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

RECIPIENTS ID CODE/NA9E.

YOUNGBLOODEB 05 HILSONE JERRY 07 AEOO 18 0/DIR HUM FAC15 EDO L STAFF'9 ILE 09

'PA 20 OELD 21 QA BR 14 RUTHERFORDid ~ IE COPIES LTTR ENCL-1 1

1 1

1 1

1 1

1 1

2 2

1 1

1 1

1 1

1 1

EXTERNAL: ACRS NSIC 16 08 I

16 16 1

1 LPDR 03 1

1 SEP gg t980 43 TOTAL NUMBER OF COPIES REQUIRED:

LTTR ~

ENCL'

0 tt 1 f I

"'I e

'1 I,

e II It r

CFP-IL Carolina Power & Light Company

',,"g l g, Pile:

SH N-2/18 Item 43 August 19, 1980 Mr. James P. O'Reilly United States Nuclear Regulatory Commission Region II 101 Marietta Street, Northwest Atlanta, Georgia 30303 SHEARON HARRIS NUCLEAR POWER PLANT UNITS 1, 2, 3, AND 4 DOCKET NOS. 50-400,'0-401, 50-402 AND 50-403 USE OP INSUFFICIENT PRElKAT IN THE PIELD WELDING OP SEISMIC I HANGERS

Dear Mr. O'Reilly:

On July 22, 1980,.the Region XI,office,'(Mr. V..Brownlee) was notl,fied by the Carolina Power

& Light Company (CP&L) of:a potentially.reportable item concerning the use of insufficient preheat in the'ield.welding of.Seismic I hangers.

As indi-cated,duxing the August 19, 1980,. telephone conversation with, youx Mr. J. K. Rausch, CP&L has not completed'ts metallurgical evaluation of thismatter'o determine whether the problem is reportable'.per'he'rovisions of 3,0CPR50.55(e) and 10CPR Part 21. It is now anticipated'hat this reportability. evaluation will be completed by September',

1980,. at which time the'RC.will.be notified of our decision.

Thank you for your consideration in this matter.

rVR/mt.(090 861) cc:

Mr. V. Stello (2).

Yours very truly, N

J. Chi gi ger Eng neexing Construction

Quality, ssuxance a Oeel 00 Pk5 411 Fayettevllle Street

~ P. O. Box 1551

~ Raleigh, N. C. 27602

'FPIOIAL"COPY

~ t 0

F