ML18009A647

From kanterella
Jump to navigation Jump to search
Amend 21 to License NPF-63,revising Table 3.7-6,Item 19 Re Max Temp for Tank Area & Deleting Item 17 Concerning Max Temp for Fuel Pool Cooling Pump & HX Area
ML18009A647
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 09/06/1990
From: Adensam E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML18009A648 List:
References
NPF-63-A-021 NUDOCS 9009140113
Download: ML18009A647 (5)


Text

h pe REGIJ, G+

Qp UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 CAROLINA POWER 8

LIGHT COMPANY et al.

DOCKET NO. 50-400 SHEARON HARRIS NUCLEAR POWER PLANT UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

21 License No.

NPF-63 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Carolina Power 8 Light Company, (the licensee),

dated December 18, 1989, as supplemented January 12,

1990, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2:

Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating License No.

NPF-63 is hereby amended to read as follows:

9009140113 900906 PDR ADOCK 05000400 P

PDC

"2" (2)

Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, and the Environmental Protection Plan contained in Appendix 8, both of which are attached

hereto, as revised through Amendment No. 2I, are hereby incorporated into this license.

Carolina Power 8 Light Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications Orignal signed by:

Elinor G.

Adensam, Director Project Directorate II-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Date of Issuance:

September 6

]99O OFC: L NAME: P DATE

7 /

DRPR: PM: PD21: DRPR: SP 0

n.:

RB cCracken

/90:

I l90: rilkl90 OGC

0 P

1:

RPR:

~

~

a

EA sam

~ t / ~/9O

/

/9O OFFICIAL RECORD COPY

~

~

g

~

'4 r

~

~

r

~

~

~

~

r

ATTACHMENT TO LICENSE AMENOMENT NO.

FACILITY OPERATING LICENSE NO.

NPF-63 OOCKET NO. 50-400 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.

The revised areas are indicated by marginal lines.

Remove Pa es 3/4 7-29 Insert Pa es 3/4 7-29

TABLE 3.7-6 AREA TEMPERATURE MONITORING MAXIMUM TEMPERATURE LIMIT ('F)

REACTOR AUXILIARYBUILDING l.

2 ~

3 ~

4.

5 ~

6.

7 t 8.

9.

10.

11.

12.

13.

14.

15.

Control Room Envelope (El 305')

Process I&C, Room (El 305')

Rod Control Cabinets Area (El 305')

A&B Battery Rooms (El 286')

A&B Switchgear Rooms (El 286')

Main Steam, Feedwater Pipe Tunnel (El 286' 261')

SA&SB Electrical Penetration Areas (El 261' 286')

Area with MCC lA35SA and 1B35SB (El 261')

HVAC Chillers, Auxiliary FW Piping

& Valve Area (El 261')

CCM Pumps,.

CCW Hx, Auxiliary FM Pumps Area (El 236')

1A-SA, 1B-SB, and 1C-SAB Charging Pump Rooms (El 236')

Service Water Booster Pump 1B-SB (El 236')

Mechanical and El.ectrical Penetration Areas (El 236')

Containment Spray Additive Tank, and H&V Equipment Area (El 216')

Trains A&B Containment Spray

Pump, RHR Pump, H&V Equipment Areas (El 190')

85 85 104 85 90 116 104 104 104 104 104 104 104 104 104 FUEL HANDLING BUILDING 16.

17.

Trains A&B Emergency Exhaust System Areas (El 261')

Deleted 104 WASTE PROCESSING BUILDING 18.

H&V Equipment Room (El 236')

104 MISCELLANEOUS 19.

20.

21.

w 22 ~

23.

24.

25.

26.

27.

Tank Area (El 236')

Diesel Fuel Oil Storage Building (El 242')

Emergency Service Mater Electrical Equipment Room Emergency Service Mater Pump Room DELETED 1A-SA & 1B-SB H&V Equipment Rooms (El 292')

lA-SA & 1B-SB H&V Equipment Rooms (El 280')

1A"SA & 1B-SB Electrical Rooms (El 261')

1A-SA & 1B-SB Diesel. Generator Rooms (El 261')

104 122 104 122 122 118 116 120 SHEARON HARRIS - UNIT 1-3/4 7-29 Amendment No.

21