05000250/LER-1979-035, Forwards LER 79-035/01T-0

From kanterella
(Redirected from ML17339A387)
Jump to navigation Jump to search
Forwards LER 79-035/01T-0
ML17339A387
Person / Time
Site: Turkey Point 
Issue date: 11/23/1979
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17339A389 List:
References
NUDOCS 7912130632
Download: ML17339A387 (2)


LER-1979-035, Forwards LER 79-035/01T-0
Event date:
Report date:
2501979035R00 - NRC Website

text

t'.O. IdOX 629100, MIAhll,f L MltaC a'a a aim FLORIDA POWER 8 LIGHTCOMPANY November 23, 1979 PRN-LI-79-423 Mr. James P. O'Reilly, Director, Region II Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

REPORTABLE OCCURRENCE 250-79-35 TURKEY POINT UNIT 3 DATE OF OCCURRENCE:

NOVEMBER 9 1979 ECCS ANALYSIS-POTENTIAL NONCONSERVATISM The attached Licensee Event Report is being submitted in accordance with Technical Specification 6.9.2 to provide prompt notification of the subject occurrences Very truly yours, A.

D. Schmidt Vice President Power Resources MAS/cph Attachment cc:

Di rector, Office of Inspecti on Di rectqr, Office of Management Harold Reis, Esquire Fi le 933.1TP and Enforcement (40)

Information and Program Control (3)

QQ3.

~jj

'7qdIS &

pp+ "p