~8 REgy

~4

0

fy

O

I

CO

Cy

+~

~O

++*++

In Reply Refer To:

RII:RVL

50-250/79-26

50-251/79"26

UNITEDSTATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100

ATLANTA,GEORGIA 30303

PEP

5

1979

Florida Power and Light Company

Attn:

R. E. Uhrig, Vice President

Advanced

Systems

and Technology

Post Office Box 529100

Miami, Florida

33152

Gentlemen:

This refers to the inspection

conducted

by R. Vogt-Iowell of this office

on August 6-10,

1979 of activities authorized

by NRC License Nos.

DPR-31

an'd DPR-41 for the Turkey Point facility, and to the discussion of our

findings held with H. E. Yaeger at the conclusion of the inspection.

Areas

examined during the inspection

and our findings are discussed

in

the enclosed inspection report.

Within these

areas,

the inspection

consisted of selective

examinations of procedures

and representative

records,

interviews with personnel,

and observations

by the inspector.

We have

examined actions

you have taken with regard to previously reported

unresolved items'he

status of these

items is discussed

in the enclosed

report.

During the inspection, it was found that certain activities under your

license

appear

to be in noncompliance with NRC requirements.

These

items

and references

to pertinent requirements

are listed in the Notice

of Violation enclosed

herewith as Appendix A.

This notice is sent to

you pursuant to the provisions of Section 2.201 of the NRC's "Rules of

Practice", Part 2, Title 10,

Code of Federal Regulations.

Section 2.201

,requires

you to submit to this office, within 20 days of your receipt of

this notice,

a written statement

or explanation in reply including:

(1)

corrective steps

which have been taken by you,

and the results

achieved;

(2) corrective steps

which will be taken to avoid further noncompliance;

and (3) the date

when full compliance will be achieved.

In accordance

with Section 2.790 of the NRC's "Rules of Practice,"

Part 2, Title 10,

Code of Federal Regulations,

a copy of this letter and

the enclosed inspection report will be placed in the NRC's Public Document

Room. If this report contains

any information that you (or your contractor)

believe to be proprietary, it is necessary

that you make

a written

application within 20 days to this office to withhold such information

~

~

Florida Power

and Light Company

SEP

5

1979

from public disclosure.

Any such application must include

a full statement

of the reasons

on the basis of which it is claimed that the information

is proprietary,

and should be prepared

so that proprietary information

identified in the application is contained in a separate

part of the

document.

If we do not hear from .you in this regard within the specified

period,

the report will be placed in the Public Document

Room.

Should you have any questions

concerning this letter,

we will be glad to

discuss

them with you.

Sincerely,

R.

C. Lewis, Acting Chi f

Reactor Operations

and

Nuclear Support Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Inspection Report Nos. 50-250/79-26

and 50-251/79-26

cc w/enclosures:

H. E. Yaeger, Plant Manager

Post Office Box 013100

Miami, Florida

33101