Attachment 3 to AEP:NRC:1124B PROPOSED REVISED TECHNICAL SPECIFICATION PAGES 9506060418 950525 PDR ADOCK 05000315 ,','I P,

PDR

a+F C i,

'x I

DESIGiV FEATURES DESICV PRESSURE AVD T MPERATLRE 5.2.2 The reactor containment building is designed and shall be 'maintained in accordance with the ori.ginal design provisions contained in Section 5.2.2 of the FSAR.

PENETRATIONS 5.2.3 Penetrations through the reactor containment building are designed and shall be maintained in accordance with the ori.ginal design provisi.ons contained in Section 5.4 of the FSAR with allowance for normal degradation pursuant to the applicable Surveillance Requirements.

5.3 REACTOR CORE f A FUEL ASSEefBLIES 5.3.1 The reactor core shall contain 193 fuel *assemblies with each fuel assembly containing 204 fuel x'ods clad with Zircaloy-4~ - Each fuel rod shall have a nominal active fuel length of 144 inches., The initial core loading shall have a maximum enrichment of 3.35 weight percent U-235.

Reload fuel shall be similar in physi.cal design to the initi.al core loading and shall have a maxlmnm nominal enriohsenr of 4.95 weight percene U-235.

CONTROL ROD ASSE.fBLIES 5.3.2 The reactor core shall contain 53 full length and no pax't 1ength control xod assemblies.

The full length control x'od assemblies shall contain a nominal 142 inches of absorber material.

The nominal values of absorber materi.al shall be 80 percent silver, 15 percent indium and 5

percent, cadmium.

All control rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLPVT SYSTEM"i DESICV PRESSURE AVD TcÃPERATURE 5.4.1 The reactox'oolant system is designed and shall be maintained:

COOK NUCLEAR PLANT - UNIT 1 5 4

~DXENT NO. l82

r

DES IGN FEATURES 5

~ 3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor coze shall contain 193 fuel assemblies with each fuel assembly containing 264 fuel rods clad with Zircaloy-4i-- Each fuel rod shall have a nominaL active fuel length of 144 inches.

The initial core loading shall have a maximum enrichment of 3.3 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and may be nominally enriched up to 4.95 weight percent U-235.

CONTROL ROD ASSE.'GULLIES 5,3.2 The reactor core shall contain 53 full length and no part length control rod assemblies, The full length control. zod assemblies shall contain a nominal 142 inches of absorber material.

The nominal values of absorber material shall be.80 percent silver, 15 percent indium and 5 percent cadmium.

All control rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTE."i DESIGN PRESSURE AND TENPERATURE 5 4 1.1 The reactor coolant system.is designed and shall be maintained:

In accordance with the code requirements specified in Section 4.1.6 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements.

b.

For a pressure'f 2485 psig, and c,

For a temperature of 650 F, except for the pressurizer which is 680 F.

COOK NUCLEAR PLANT - UNIT 2 5-4 msmmrr NO.

SS 152

except that limited substitutions of zirconium alloy or stainless steel filler rods, in accordance with NRC-approved applications of fuel rod configurations, may be used.

Attachment 2 to AEP:NRC:1124B EXISTING TECHNICAL SPECIFICATIONS PAGES MARKED TO REFLECT PROPOSED CHANGES

5.0 DESIGN FEATURES 5.2 CONTAINMENT Continued DESIGN PRESSURE AND TEMPERATURE 5.2.2 The reactor containment building is designed and shall be maintained in accordance with the original design provisions contained in Section 5.2.2 of the FSAR.

PEN ETRATIONS 5.2.3 Penetrations through the reactor containment building are designed and shall be maintained in accordance with the original design provisions contained in Section 5.4 of the FSAR with allowance for normal degradation pursuant to the applicable Surveillance Requirements.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 193 fuel assemblies with each fuel assembly containing 204 fuel rods clad with Zircaloy4, except that limited substitutions of zirconium alloy or stainless steel filler rods, in accordance with NRC-approved applications of fuel rod configurations, may be used.

Each fuel rod shall have a nominal active fuel length of 144 inches.

The initial core loading shall have a maximum enrichment of3.35 weight percent U-235. Reload fuel shall be similar in physical design to the initialcore loading and shall have a maximum nominal enrichment of 4.95 weight percent U-235.

CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 53 full length and no part length control rod assemblies.

The full length control rod assemblies shall contain a nominal 142 inches of absorber material.

The nominal values of absorber material shall be 80 percent silver, 15 percent indium and 5 percent cadmium. Allcontrol rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

COOK NUCLEAR PLANT-UNITI Page 5-4 AMENDMENT4Q, 440

5.0 DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 193 fuel assemblies with each fuel assembly containing 264 fuel rods clad with ZircaloyA, except that limited substitutions of zirconium alloy or stainless steel filler rods, in accordance with NRC-approved applications of fuel rod configurations, may be used.

Each fuel rod shall have a nominal active fuel length of 144 inches. The initialcore loading shall have a maximum enrichment of3.3 weight percent U-235. Reload fuel shall be similar in physical design to the initial core loading and may be nominally enriched up to 4.95 weight percent U-235.

CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 53 full length and no part length control rod assemblies.

The full length control rod assemblies shall contain a nominal 142 inches of absorber material.

The nominal values of absorber material shall be 80 percent silver, 15 percent indium and 5 percent cadmium. Allcontrol rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

In accordance with the code requirements specified in Section 4.1.6 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements.

b.

For a pressure of 2485 psig, and For a temperature of 650'F, except for the pressurizer which is 680'F.