Docket Ho. 50-315

Docket No. 50-316

EA 90-194

Indiana tiichigan Power

Company

ATTN:

Hr. Hilton P. Alexich

Vice President

Nuclear Operations Division

'

Riverside Plaza

.

Columbus,

OH

43216

'entlemen:

This refers to the special

safety inspection

conducted

by lair. Joseph

t1. Ulie

and others of this office on September

10-14, October

5 and

November 6, 1990,

of activities at the D.

C.

Cook Nuclear Plant, Units

1 and 2, authorized

by

.NRC Operating

Licenses

No.

DPR-58

and

No.

DPR-74

and to the discussion

of our

findings with you and others of your staff at the conclusion of the inspection.

This inspection

involved

a full scope follow up review of Sections III.G, J

and

L of 10 CFR Part 50, Appendix R.

The enclosed

copy of our inspection report identifies areas

examined during

the inspection.

Within these

areas,

the inspection consisted

of a selective

examination of procedures

and representative

records,

observations,

and

interviews with personnel.

During this inspection,

certain of your activities appeared

to be in violation

of NRC requirements.

For these

apparent violations,

we are releasing this

report at this time for your information.

Following an Enforcement

Conference,

presently

scheduled for November 20, 1990, you will be notified by separate

correspondence

of our decision regarding

enforcement

actions related to these

issues.

No written response

is required until you are notified of the proposed

enforcement actions.

Additionally, the inspection

addressed

two other issues

that are not related

to the pending of the Enforcement

Conference.

These additional

issues

are:

(1) utilizing a licensee staff member for a triennial auditing team

while this individual had direct responsibilities

in the area

being audited;

and (2)

a deviation from an

FSAR commitment to protect structural steel.

Issue

Ho.

1 is

a violation of 10 CFR 50, Appendix B, Criterion XVIII, Audits,

as

described

in the attached

Notice of Violation.

The inspection

showed that

actions

had been

taken to resolve

the identified violation and to prevent

recurrence.

Our understanding

of your actions is described

in Paragraph 3.i.

of the enclosed

inspection report.

Consequently,

no reply to this violation is

'equired,

and we have

no further questions

regarding this matter.

Regarding

Issue

No. 2, our understanding

of your actions is described

in Paragraph

4.a.

of the enclosed

inspection report.

Consequently,

a Notice of Deviation is not

being issued

and

we have

no further questions

regarding this matter.

'~02 i yg(ip-,

Pglp

gpss

~~

JOAN d (lp

Q

DC'.P~~Qg~~

~ +

Fbi.

~

I

T

0

Indiana Michigan Power

Company

NOV

9 i890

In accordance

with 10 CFR 2.790 of the Commission's

regulations,

a copy of

this letter and the enclosures will be placed in the

NRC Public Document

Room.

'e

will gladly discuss

any questions

you have concerning this inspection.

S incerely,

OPwtGi<>V L J+jCi't g p/

Enclosures:

l.

Inspection

Reports

No. 50-315/90018(DRS);

No. 50-316/90018(DRS)

2.

Notice of Violation

cc w/enclosures:

A. A. Blind, Plant Manager

DCD/DCB (RIDS)

OC/LFDCB

Resident

Inspector, RIII

James

R. Padgett,

tlichigan Public

Service

Commission

EIS Coordinator,

USEPA,

Region

5 Office

,tlichigan Department of

Public Health

D.

C.

Cook LPH,

NRR

bcc w/enclosures:

J.

Lieberman,

OE

J. Goldberg,

OGC

J. Partlow,

NRR

T. 0. Hartin, Director

Division of Reactor Safety

RIII

lie/jk/lc

11/08/90

SAIC

Storey

11/1 /90

RIII

~Butler

11~9 /90

RI I I PC

tv

RI I

Le

artz

11/'7 /90

RIII

Gardner

11/ 9 /90

BNL

Fre

co

11/ 9 /90

RIII

Ring

11/cj /90

BNL

ull van

11/

/90

P

Wederson

artin

11/) /90 II/f/90

T

0