ADMINISTRATIVE CONTROLS b.

Ce At least one licensed Operator shall be in the control room when fuel is in the reactor.

In addi.tion, while the unit is in Mode 1; 2, 3, or 4, at least one licensed Senior Operator shall be in the control room.

An individual* qualified in radiation protection procedures shall be on site when fuel is in the reactor.

d.

All CORE ALTERATIONS shall be directly supervised by a licensed Senior Operator trained or qualified in refueling and CORE ALTERATIONS (SO-CA) who has no other concurrent responsibilities during this operation.

Be A site fi.re brigade of at onsite at all times.

The of the minimum shift crew or any personnel required fire emergency.

least 5 members* shall be maintained fire brigade shall not include 3 members necessary for safe shutdown of the unit for other essential functions during a The amount of overtime worked by plant staff members performing safety-related functions must be limited in accordance with NRC Policy Statement on working hours (Generic Letter 82-12).

g

~

The Shift Supervisor, Assistant Shift Supervisor, and Uni.t Supervisor shall hold a Senior Operator License, h.

The Operations Superintendent must have held a Senior Operator License at Cook Nuclear Plant or a similar reactor and one mid-level Production Supervisor shall hold a current Senior Operator License.

The individual qualified in radiation protection procedures and the composition of the fire brigade may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in order to accommodate unexpected absence provided immediate action is taken to fillthe required positions.

COOK NUCLEAR PLANT - UNIT 1 6-2 AMENDMENT NO.

8912200150 891212 PDR ADOCK 05000315 P

PNU

ADMINISTRATIVE CONTROLS 6.3 FACILITY STAFF UALIFICATIONS 6.3.1 Each member of the facility staff'shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions, except for (1) the Plant Radiation Protection Manager, who shall meet or exceed qualifications of Regulatory Guide 1 ~ 8, September

1975, (2) the Shift Technical Advisor, who shall have a bachelor's degree or equivalent in a scientific or engineering discipline with specific training in plant design, and response and analysis of the plant for transients and accidents
and, (3) the Operations Superintendent must have held a Senior Operator License as specified in Section 6.2.2.h.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction of the Training Manager and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and of 10 CFR Part 55.

6.4.2 A training program for the fire brigade shall be maintained under the direction of the Plant Manager and shall meet or exceed the requirements of Section 27 of the NFPA Code-1976.

6.5 REVIEW AND AUDIT 6.5.1 PLANT NUCLEAR SAFETY REVIEW COMMITTEE PNSRC FUNCTION 6.5.1.1 The PNSRC shall function to advise the Plant Manager on all matters related to nuclear safety.

COMPOSITION 6.5.1.2 The PNSRC shall be composed of Assistant Plant Managers, Department Superintendents, or supervisory personnel reporting directly to the Plant Manager, Assistant Plant Managers or Department Superintendents from the functional areas listed below:

Licensing Activities Safety

& Assessment Operations Technical Support Radiation Protection Maintenance The Chairman, his alternate and other members and their alternates of the PNSRC shall be designated by the Plant Manager.

In addition to the

Chairman, the PNSRC membership shall consist of a minimum of one individual from each of the areas designated above.

PNSRC members and alternates shall meet or exceed the minimum qualifications of ANSI N18.1-1971 Section 4.4 for comparable positions.

The nuclear power plant operations individual shall meet the qualifications of Section 4'.2 and the maintenance individual shall meet the qualifications of Section 4.2.3 of ANSI N18.1-1971.

COOK NUCLEAR PLANT - UNIT 1 6-4 AMENDMENT NO.

ADMINISTRATIVE CONTROLS b.

At least one licensed Operator shall be in the control room when fuel is in the reactor.

In addition, while the unit is in Mode 1, 2, 3, or 4, at least one licensed Senior Operator shall be in the control room.

c.

An individual qualified in radiation protection procedures shall be on site when fuel is in the reactor.

d.

All CORE ALTERATIONS shall be directly supervised by a licensed Senior Operator trained or qualified in refueling and CORE ALTERATIONS (SO-CA) who has no other concurrent responsibilities during this operation.

B>>

A site fire brigade of at onsite at all times, The of the minimum shift crew or any personnel required fire emergency.

least 5 members shall be maintained fire brigade shall not include 3 members necessary for safe shutdown of the unit for other essential functions during a f.

The amount of overtime worked by plant staff members performing safety-related functions must be limited in accordance with NRC Policy Statement on working hours (Generic Letter 82-12).

g.

The Shift Supervisor, Assistant Shift Supervisor, and Unit Supervisor shall hold a Senior Operator Licensees h.

The Operations Superintendent must have held a Senior Operator License at Cook Nuclear Plant or a similar reactor and one mid-level Production Supervisor shall hold a current Senior Operator License.

The individual qualified in radiation protection procedures and the composition of the fire brigade may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in order to accommodate unexpected absence provided immediate action is taken to fillthe required positions.

COOK NUCLEAR PLANT - UNIT 2 6-2 AMENDMENT NO.

0 k

~l jll C

ADMINISTRATIVE CONTROLS 6.3 FACILITY STAFF UALIFICATIONS 6.3.1 Each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18,1-1971 for comparable positions, except for (1) the Plant Radiation Protection Manager, who shall meet or exceed qualifications of Regulatory Guide 1,8, September

1975, (2) the Shift Technical Advisor, who shall have a bachelor's degree or equivalent in a scientific or engineering discipline with specific training in plant design, and response and analysis of the plant for transients and accidents
and, (3) the Operations Superintendent must have held a Senior Operator License as specified in Section 6.2.2.h.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction of the Training Manager and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and of 10 CFR Part 55.

6.4,2 A training program for the fire brigade shall be maintained under the direction of the Plant Manager and shall meet or exceed the requirements of Section 27 of the NFPA Code-1976.

6.5 REVIEW AND AUDIT 6.5.1 PLANT NUCLEAR SAFETY REVIEV COMMITTEE PNSRC FUNCTION 6.5,1.1 The PNSRC shall function to advise the Plant Manager on all matters related to nuclear safety.

COMPOSITION 6.5.1,2 The PNSRC shall be composed of Assistant Plant Managers, Department Superintendents, or supervisory personnel reporting directly to the Plant Manager, Assistant Plant Managers or Department Superintendents from the functional areas listed below:

'Licensing Activities Safety

& Assessment Operations Technical Support Radiation Protection Maintenance The Chairman, his alternate and other members and their alternates of the PNSRC shall be designated by the Plant Manager.

In addition to the

Chairman, the PNSRC membership shall consist of a minimum of one individual from each of the areas designated above'NSRC members and alternates shall meet or exceed the minimum qualifications of ANSI N18.1-1971 Section 4.4 for comparable positions.

The nuclear power plant operations individual shall meet the qualifications of Section 4.2.2 and the maintenance individual shall meet the qualifications of Section 4.2.3 of ANSI N18.1-1971.

COOK NUCLEAR PLANT - UNIT 2 6-4 AMENDMENT NO.