CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3;6.4.1 Two containment hydrogen analyzers shall be OPERABLE.
APPLICABILITY:
MODES 1 and 2
ACTION:
With one hydrogen analysis device inoperable, restore the inoperable analysis device to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
SURVEILLANCE RE UIREMENTS 4.6.4.1 Each hydrogen analysis device shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL
)
CALIBRATION using a zero and span gas.
D. C.
COOK - UNIT 1 3/4 6-23 Amendment No.
a'(i-t.
I
CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3.6.4.1 Tvo containment hydrogen analyzers shall be OPERABLE.
APPLICABXLITY:
MODES 1 and 2
ACTION:
Hath-one hydrogen analysis device inoperable, restore the inoperable analysis device to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />..
'SURVEILLANCE RE UIM2LENTS 4.6,4.1 Each hydrogen analysis device shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL CALXBRATXON using a sero and span gas.