DONALD C.

COOK NUCLEAR PLANT, UNIT NOS.

1 AND 2 TECHNICAL SPECIFICATIONS CHANGE REQUEST ATTACHMENT TO AEP:NRC:0631A 0 820929 8210050~

05000~~5

>>< pgQC pDR p

.I

~ I

(

t 1

I I

a

.g%

U

\\

J 4

CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3;6.4.1 Two containment hydrogen analyzers shall be OPERABLE.

APPLICABILITY:

MODES 1 and 2

ACTION:

With one hydrogen analysis device inoperable, restore the inoperable analysis device to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE RE UIREMENTS 4.6.4.1 Each hydrogen analysis device shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL

)

CALIBRATION using a zero and span gas.

D. C.

COOK - UNIT 1 3/4 6-23 Amendment No.

a'(i-t.

I

CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3.6.4.1 Tvo containment hydrogen analyzers shall be OPERABLE.

APPLICABXLITY:

MODES 1 and 2

ACTION:

Hath-one hydrogen analysis device inoperable, restore the inoperable analysis device to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />..

'SURVEILLANCE RE UIM2LENTS 4.6,4.1 Each hydrogen analysis device shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL CALXBRATXON using a sero and span gas.