Category:LEGAL TRANSCRIPTS & ORDERS & PLEADINGS
MONTHYEARML20217E1551999-09-28028 September 1999 Comment Supporting Pr 10CFR50 Re Elimination of Requirement for Licensees to Revise ISI & IST Programs Beyond Baseline Edition & Addenda of ASME B&PV Code ML17313B0651999-07-30030 July 1999 Comment on Draft Rg DG-1076, Service Level I,Ii & III Protective Coatings Applied to Npps. ML17313B0161999-07-0101 July 1999 Comment on Draft Rg DG-1074, SG Tube Integrity. ML20196K5631999-06-29029 June 1999 Comment Supporting Proposed Rule 10CFR50.55a Re Elimination of 120-month Requirement to Update ASME Code ISI & Inservice Testing Program ML20207D1591999-05-20020 May 1999 Comment on Proposed Rules 10CFR21,50 & 54 Re Use of Alternative Source Terms at Operating Reactors ML17313A9791999-05-20020 May 1999 Comment Opposing Draft Reg Guide DG-1084, Qualification & Training of Personnel for Nuclear Power Plants. as General Comment,Util Believes That Many of Proposed Changes Will Limit Ability to cross-train Mgt Level Personnel ML20205A4271999-03-18018 March 1999 Comment on Petition for Rulemaking PRM-50-64 Which Requested Greater Clarification by NRC Re Possible Financial Obligations of NPP Licensees as Reflected in NRC Final Policy Statement on Restructuring & Economic Deregulation ML17313A8521999-03-0505 March 1999 Comment Supporting Proposed Change to NRC Enforcement Policy.Suggested Rewording of Sections Provided ML17313A8191999-02-24024 February 1999 Comment Supporting Secy 99-007, Recommendation for Reactor Oversight Process Improvements, & Comments Provided by NEI & Regional Utility Group Iv.Offers Comments on NRC Approach to Using Performance Indicators in Assessment Process ML20198J4031998-12-11011 December 1998 Comment Opposing Proposed Rule 10CFR50 Re Requirement for Monitoring Effectiveness of Maint at NPPs ML20217B9761998-04-0909 April 1998 Comment Re Draft RG DG-1029, Guidelines for Evaluating Electromagnetic & Radio-Frequency Interference in Safey-Related Instrumentation & Control Sys ML20216A9091998-04-0303 April 1998 Comment Opposing Proposed Rule 10CFR50.55a Re Industry Codes & Stds ML17313A3361998-03-27027 March 1998 Comment Opposing Proposed GL Re Lab Testing on Nuclear-Grade Activated Charcoal. Believes That Proposed 60 Day Implementation Schedule Would Severely Challenge Resources of Limited Number of Qualified Vendors ML20217E8781998-03-27027 March 1998 Comment Supporting Proposed GL, Lab Testing of Nuclear- Grade Activated Charcoal ML17313A2511998-03-0303 March 1998 Comment on Proposed GL 98-XX Re Yr 2000 Readiness of Computer Sys at Npps. ML20203L5521998-02-25025 February 1998 Forwards Comments on Draft Reg Guide DG-5008, Reporting of Safeguards Events ML20202E4251998-01-30030 January 1998 Comment on Draft RG DG-1070, Sampling Plans Used for Dedicating Simple Metallic Commercial Grade Items for Use in Npps. Draft RG Should Be Revised to Clarify That Alloy Analyzer Can Be Used Consistent W/Guidance in EPRI NP-5652 ML20199E0871998-01-17017 January 1998 Comment Opposing PRM 50-63A by Pg Crane Re Amending Emergency Planning Regulations to Require Consideration of Prophylactic Use of Potassium Iodide for General Public ML20202G4461997-12-0101 December 1997 Comment on Proposed Final Rule 10CFR50.Licensee Requests That Effective Date Be Delayed from 980101 to 0601,in Order to Provide Enough Time to Request & Obtain NRC Review of Exemption from Rule ML20212D1391997-10-17017 October 1997 Comment on Pr 10CFR55 Re NUREG-1021,Interim Rev 8, Operator Licensing Exam Stds for Power Reactors ML17312B4241997-04-23023 April 1997 Comment Supporting Draft Rg DG-1068 (Proposed Rev 3 to Rg 1.134, Medical Evaluation of Licensing Personnel at Npps) ML20134J9671997-02-0606 February 1997 Comment Supporting Proposed Rule 10CFR50, Draft Policy Statement on Restructuring & Economic Deregulation of Electric Util Industry ML20134N2521996-11-14014 November 1996 Comment on Draft RG DG-1012,proposed Rev 3 to RG 1.8, Qualification & Training of Personnel for Npp ML20117E3871996-08-0707 August 1996 Comment Supporting Proposed Rule 10CFR26 Re Mod to fitness-for-duty Program Requirements ML20113C6981996-06-24024 June 1996 Comment Supporting Proposed Rule 10CFR50, Financial Assurance Requirements for Decommissioning Nuclear Power Reactors. Cautions NRC Not to Adopt Rules That Are Too Restrictive & Could Lead to Premature Decommissioning ML20117P1261996-06-24024 June 1996 Comment on Proposed Rule 10CFR50, Financial Assurance Requirements for Decommissioning Nuclear Power Reactors. Urges NRC to Approach Rulemaking Re Decommissioning Costs in Manner That Will Facilitate Federal Legislative Solution ML20095A8461995-11-28028 November 1995 Comment on Petition for Rulemaking PRM-50-62 Re Proposed Changes to 10CFR50.54.Util Endorses Industry Petition & Response Provided by NEI ML17311B2931995-11-27027 November 1995 Comment Opposing Draft NUREG/CR-6354, Performance Testing of Electronic Personnel Dosimeters. ML17311B1601995-08-31031 August 1995 Comment Opposing Review of Revised NRC SALP ML20087H7241995-08-16016 August 1995 Comment Opposing Proposed Rule 10CFR2 Re Comment on Revision of NRC Enforcement Policy ML20087H7501995-08-0404 August 1995 Comment on Proposed Rule 10CFR52 Re Std Design Certification for ABWR Design & Std Design Certification for Sys 80+ Design ML20087H7331995-08-0404 August 1995 Comment on Proposed Rule 10CFR52 Re Standard Design Certification for ABWR Design & Standard Design Certification for Sys 80+ Design.Concurs w/ABB-CE Comments & NEI Recommendations ML17311B0071995-06-27027 June 1995 Comment on Proposed Review of NRC Insp Rept Content,Format & Style. Insp Detail Should Be Brief & Ref Previous Rept by Section or at Min IR Number ML20083N5031995-05-0505 May 1995 Comment on Proposed Rev to 10CFR50,app J, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors. Proposed Rev Will Result in Highly Efficient Regulation ML20082P7461995-04-19019 April 1995 Comment Supporting Proposed Rules 10CFR170 & 171 Re Proposed Revs of NRC Fee Schedule for FY95 in Fr ML20082H0971995-04-10010 April 1995 Draft Policy Statement Re Freedom of Employees in Nuclear Industry to Raise Safety Concerns W/O Fear of Retaliation ML20081B5721995-03-0808 March 1995 Motion of Plains Electric Generation & Transmission Cooperative,Inc to Withdraw,W/Prejudice,Petition for Leave to Intervene,Request for Finding of Significant Change & for Antitrust Hearing & Comments.* W/Certificate of Svc ML17311A6691995-02-0202 February 1995 Comment Supporting Draft Rg DG-8014 (Proposed Rev 3 to Rg 8.13, Instruction Concerning Prenatal Radiation Exposure) ML20078H0671995-01-20020 January 1995 Comment Supporting NUMARC Position on Proposed Rules 10CFR20,30,40,50,51,70 & 72 Re Radiological Criteria for Decommissioning of Lands & Structures ML20077M5471995-01-0404 January 1995 Comment Opposing Proposed Rule 10CFR50 Re Shutdown & low-power Operations for Nuclear Power Reactor Proposed Rule ML17311A2461994-08-25025 August 1994 Comment on Draft Reg Guide (DG-1031), Monitoring Effectiveness of Maint at Npps. Term Maint Preventable Failure Needs to Be Defined & Compared to Term Maint Preventable Functional Failure. ML17310B1911994-04-12012 April 1994 Petition to Intervene of Public Utility Commission of Texas. W/Certificate of Svc ML17310B2041994-04-12012 April 1994 Petition to Intervene of Public Utility Commission of Tx ML20062M4141993-12-27027 December 1993 Comment Supporting Petition for Rulemaking PRM-21-2 Re Procurement of Commercial Grade Items ML20056G3351993-08-27027 August 1993 Comment Opposing Proposed Rule 10CFR2 Re Review of 10CFR2.206 Process ML17306B2461993-01-15015 January 1993 Comment Supporting in Part,Draft Reg Guide DG-1020, Monitoring Effectiveness of Maint at Npps. ML17306A9571992-09-0808 September 1992 Comments on Proposed Rev to Staff Technical Position on Radwaste Classification.Supports Rev ML20099E0621992-07-29029 July 1992 Comment Opposing Proposed Rule 10CFR50.63, Loss of All AC Power ML20090F9661992-03-0909 March 1992 Comment Supporting Proposed Rule 10CFR50 & 52 Re Training & Qualification of Nuclear Power Plant Personnel ML17306A4501992-02-0404 February 1992 Comment on Draft Reg Guide Task DG-8007 (Proposed Rev 1 to Reg Guide 8.7) Re Instructions for Recording & Reporting Occupational Radiation Exposure Data 1999-09-28
[Table view] Category:PUBLIC COMMENTS ON PROPOSED RULES & PETITIONS FOR
MONTHYEARML20217E1551999-09-28028 September 1999 Comment Supporting Pr 10CFR50 Re Elimination of Requirement for Licensees to Revise ISI & IST Programs Beyond Baseline Edition & Addenda of ASME B&PV Code ML17313B0651999-07-30030 July 1999 Comment on Draft Rg DG-1076, Service Level I,Ii & III Protective Coatings Applied to Npps. ML17313B0161999-07-0101 July 1999 Comment on Draft Rg DG-1074, SG Tube Integrity. ML20196K5631999-06-29029 June 1999 Comment Supporting Proposed Rule 10CFR50.55a Re Elimination of 120-month Requirement to Update ASME Code ISI & Inservice Testing Program ML17313A9791999-05-20020 May 1999 Comment Opposing Draft Reg Guide DG-1084, Qualification & Training of Personnel for Nuclear Power Plants. as General Comment,Util Believes That Many of Proposed Changes Will Limit Ability to cross-train Mgt Level Personnel ML20207D1591999-05-20020 May 1999 Comment on Proposed Rules 10CFR21,50 & 54 Re Use of Alternative Source Terms at Operating Reactors ML20205A4271999-03-18018 March 1999 Comment on Petition for Rulemaking PRM-50-64 Which Requested Greater Clarification by NRC Re Possible Financial Obligations of NPP Licensees as Reflected in NRC Final Policy Statement on Restructuring & Economic Deregulation ML17313A8521999-03-0505 March 1999 Comment Supporting Proposed Change to NRC Enforcement Policy.Suggested Rewording of Sections Provided ML17313A8191999-02-24024 February 1999 Comment Supporting Secy 99-007, Recommendation for Reactor Oversight Process Improvements, & Comments Provided by NEI & Regional Utility Group Iv.Offers Comments on NRC Approach to Using Performance Indicators in Assessment Process ML20198J4031998-12-11011 December 1998 Comment Opposing Proposed Rule 10CFR50 Re Requirement for Monitoring Effectiveness of Maint at NPPs ML20217B9761998-04-0909 April 1998 Comment Re Draft RG DG-1029, Guidelines for Evaluating Electromagnetic & Radio-Frequency Interference in Safey-Related Instrumentation & Control Sys ML20216A9091998-04-0303 April 1998 Comment Opposing Proposed Rule 10CFR50.55a Re Industry Codes & Stds ML20217E8781998-03-27027 March 1998 Comment Supporting Proposed GL, Lab Testing of Nuclear- Grade Activated Charcoal ML17313A3361998-03-27027 March 1998 Comment Opposing Proposed GL Re Lab Testing on Nuclear-Grade Activated Charcoal. Believes That Proposed 60 Day Implementation Schedule Would Severely Challenge Resources of Limited Number of Qualified Vendors ML17313A2511998-03-0303 March 1998 Comment on Proposed GL 98-XX Re Yr 2000 Readiness of Computer Sys at Npps. ML20203L5521998-02-25025 February 1998 Forwards Comments on Draft Reg Guide DG-5008, Reporting of Safeguards Events ML20202E4251998-01-30030 January 1998 Comment on Draft RG DG-1070, Sampling Plans Used for Dedicating Simple Metallic Commercial Grade Items for Use in Npps. Draft RG Should Be Revised to Clarify That Alloy Analyzer Can Be Used Consistent W/Guidance in EPRI NP-5652 ML20199E0871998-01-17017 January 1998 Comment Opposing PRM 50-63A by Pg Crane Re Amending Emergency Planning Regulations to Require Consideration of Prophylactic Use of Potassium Iodide for General Public ML20202G4461997-12-0101 December 1997 Comment on Proposed Final Rule 10CFR50.Licensee Requests That Effective Date Be Delayed from 980101 to 0601,in Order to Provide Enough Time to Request & Obtain NRC Review of Exemption from Rule ML20212D1391997-10-17017 October 1997 Comment on Pr 10CFR55 Re NUREG-1021,Interim Rev 8, Operator Licensing Exam Stds for Power Reactors ML17312B4241997-04-23023 April 1997 Comment Supporting Draft Rg DG-1068 (Proposed Rev 3 to Rg 1.134, Medical Evaluation of Licensing Personnel at Npps) ML20134J9671997-02-0606 February 1997 Comment Supporting Proposed Rule 10CFR50, Draft Policy Statement on Restructuring & Economic Deregulation of Electric Util Industry ML20134N2521996-11-14014 November 1996 Comment on Draft RG DG-1012,proposed Rev 3 to RG 1.8, Qualification & Training of Personnel for Npp ML20117E3871996-08-0707 August 1996 Comment Supporting Proposed Rule 10CFR26 Re Mod to fitness-for-duty Program Requirements ML20113C6981996-06-24024 June 1996 Comment Supporting Proposed Rule 10CFR50, Financial Assurance Requirements for Decommissioning Nuclear Power Reactors. Cautions NRC Not to Adopt Rules That Are Too Restrictive & Could Lead to Premature Decommissioning ML20117P1261996-06-24024 June 1996 Comment on Proposed Rule 10CFR50, Financial Assurance Requirements for Decommissioning Nuclear Power Reactors. Urges NRC to Approach Rulemaking Re Decommissioning Costs in Manner That Will Facilitate Federal Legislative Solution ML20095A8461995-11-28028 November 1995 Comment on Petition for Rulemaking PRM-50-62 Re Proposed Changes to 10CFR50.54.Util Endorses Industry Petition & Response Provided by NEI ML17311B2931995-11-27027 November 1995 Comment Opposing Draft NUREG/CR-6354, Performance Testing of Electronic Personnel Dosimeters. ML17311B1601995-08-31031 August 1995 Comment Opposing Review of Revised NRC SALP ML20087H7241995-08-16016 August 1995 Comment Opposing Proposed Rule 10CFR2 Re Comment on Revision of NRC Enforcement Policy ML20087H7331995-08-0404 August 1995 Comment on Proposed Rule 10CFR52 Re Standard Design Certification for ABWR Design & Standard Design Certification for Sys 80+ Design.Concurs w/ABB-CE Comments & NEI Recommendations ML20087H7501995-08-0404 August 1995 Comment on Proposed Rule 10CFR52 Re Std Design Certification for ABWR Design & Std Design Certification for Sys 80+ Design ML17311B0071995-06-27027 June 1995 Comment on Proposed Review of NRC Insp Rept Content,Format & Style. Insp Detail Should Be Brief & Ref Previous Rept by Section or at Min IR Number ML20083N5031995-05-0505 May 1995 Comment on Proposed Rev to 10CFR50,app J, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors. Proposed Rev Will Result in Highly Efficient Regulation ML20082P7461995-04-19019 April 1995 Comment Supporting Proposed Rules 10CFR170 & 171 Re Proposed Revs of NRC Fee Schedule for FY95 in Fr ML20082H0971995-04-10010 April 1995 Draft Policy Statement Re Freedom of Employees in Nuclear Industry to Raise Safety Concerns W/O Fear of Retaliation ML17311A6691995-02-0202 February 1995 Comment Supporting Draft Rg DG-8014 (Proposed Rev 3 to Rg 8.13, Instruction Concerning Prenatal Radiation Exposure) ML20078H0671995-01-20020 January 1995 Comment Supporting NUMARC Position on Proposed Rules 10CFR20,30,40,50,51,70 & 72 Re Radiological Criteria for Decommissioning of Lands & Structures ML20077M5471995-01-0404 January 1995 Comment Opposing Proposed Rule 10CFR50 Re Shutdown & low-power Operations for Nuclear Power Reactor Proposed Rule ML17311A2461994-08-25025 August 1994 Comment on Draft Reg Guide (DG-1031), Monitoring Effectiveness of Maint at Npps. Term Maint Preventable Failure Needs to Be Defined & Compared to Term Maint Preventable Functional Failure. ML20062M4141993-12-27027 December 1993 Comment Supporting Petition for Rulemaking PRM-21-2 Re Procurement of Commercial Grade Items ML20056G3351993-08-27027 August 1993 Comment Opposing Proposed Rule 10CFR2 Re Review of 10CFR2.206 Process ML17306B2461993-01-15015 January 1993 Comment Supporting in Part,Draft Reg Guide DG-1020, Monitoring Effectiveness of Maint at Npps. ML17306A9571992-09-0808 September 1992 Comments on Proposed Rev to Staff Technical Position on Radwaste Classification.Supports Rev ML20099E0621992-07-29029 July 1992 Comment Opposing Proposed Rule 10CFR50.63, Loss of All AC Power ML20090F9661992-03-0909 March 1992 Comment Supporting Proposed Rule 10CFR50 & 52 Re Training & Qualification of Nuclear Power Plant Personnel ML17306A4501992-02-0404 February 1992 Comment on Draft Reg Guide Task DG-8007 (Proposed Rev 1 to Reg Guide 8.7) Re Instructions for Recording & Reporting Occupational Radiation Exposure Data ML20055F4531990-06-29029 June 1990 Comment on Proposed Rule 10CFR55 Re Operators Licenses Modified for fitness-for-duty.Rule Unnecessary & May Adversely Affect Morale of Licensed Operators ML19327B1631989-09-0707 September 1989 Comment on Draft Reg Guide, Assuring Availability of Funds for Decommissioning Nuclear Reactors. Recommends That NRC Should Not Attempt to Dictate Standardized Form of Decommissioning Trust Agreement ML20235V7101989-02-27027 February 1989 Comment Opposing Proposed Rule 10CFR50 Re Ensuring Effectiveness of Maint Programs for Nuclear Power Plants. Rule Will Not Improve Maint,Reliability or Safety of Arizona Nuclear Power Project Plants 1999-09-28
[Table view] |
Text
j a.roe.red z REGAIATei'%8!itMf59 b881HEbTIoiisTEM (RIDs)
ACCESSION NBR:950 7110001 DOC.DATE: 95/06/27 NOTARIZED: NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH. NAME AUTHOR AFFILIATION GRAPO,B.A. Arizona Public Service Co. (formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION MEYERS,D. Division of Freedom of Information 6 Publications Services C~v~~",'n proposed "Review of NRC Insp Rept Content, Format F'UBJECT:
a Sty e." Insp detail should be brief & ref previous rept by section or at min IR number.
DISTRIBUTION CODE: DS09D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: SECY/DSB Dist: Public Comment on Propos d Rule R)-Misc Notice;Reg G 0 NOTES:STANDARDIZED PLANT 05000528 R Standardized plant. 05000529 Standardized plant. 05000530 RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL INTERNA . LE CENTE NMSS/IMOB T8F5 OGW/DR i 8 RES DIR RES/DS IR RES/FMPAS EXTERNAL: NRC PDR D
.C u
E N
i"POTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE 'O'ASTE! COiNTACTTHE DOCL'MEYTCOYTROL DESK, ROOiiI PI-37 (EXT. 504-20S3 ) TO ELIMIYATE YOUR YAihIE FRO!iI DISTRI!3I:!'IOY,LIS I S FOR DOCUAIEYTS YOU DOY"! .'PEED!
'TOTAL NUMBER OF- COPIES REQUIRED: LTTR 7 ENCL
i I
1 1
)
1
)
1 l
~ -(lips"O Arizona Public Service gomIDIIny //J .
PALO VERDE NUCLEAR GENERATING ETATION $
~
P.O. BOX 52034 ~ PHOENIX, ARIZQNPP+72-2034 Ii:
)E 7
l'IIIL $ PUVIAl 102 ~03400 B-fjG GUn( g.R~ p David Meyers, Chief, Rules Review and Directives Branch Division of Freedom of Information and Publication Services Office of Administration Mail Stop: T-6D-59 U.S. Nuclear Regulatory Commission Washington, DC 20555
Dear Sir:
This letter is Arizona Public Service'st (APS) response to the request for comment concerning Nuclear Regulatory Commission (NRC)
Inspection Reports . APS comments are brief and follow the format numbering in the Federal Register dated May 30, 1995 pages 28180 and 28181.
A. 1.a. Not always. If a problem is formal during an inspection that is not directly related to health and safety of the public, it but not tracked as an issue for the inspector to should be mentioned follow up.
A. 1.d. Report the facts, the concern of too negative or equal time dilutes the issue. The report should focus on regulatory issues. Too often qthe IR's drive the business end of the utility because of comments inspectors make.
A. 1.b. The detail should be - brief and reference the previous report by section or at a minimum IR number.
B. l.a. Yes, all regions should use a similar format which will assist utilities trying to trend information.
B.1.b. With a seasoned inspector focused on protection of the health and safety of the public " pulling the reins" the integrated IR's could be more comprehensive and concise.
B. 1.c. More standardization or boilerplate where applicable would ease the utilities ability to understand exactly what NRC wants accomplished.
There would be much less reaching between the lives.
9507ii000i 950b27 0500052S PDR ADQCK 8 PDR
t g
A
B.2.b. APS would favor a "bulletized" approach to inspection reports.
C. 1. APS would favor a deletion of the "we are deeply concerned comments" in the IR cover letters unless there is a clear direct tie from the actual adverse condition and the health and safety of the public.
C.2. The particular inspector should take ownership in the IR of their findings especially in team inspections to facilitate the licensee addressing issues.
C.4. APS feels that the point are generally made and the extra expense and delays which are added to the
. report to correct a few types are not warranted.
APS appreciates the opportunity to comment. If there are any questions concerning the comments please contact Burton Grabo, Section Leader of 602-393-6492.
Sincerely, Burton A. Grabo Section Leader Nuclear Regulatory Affairs
e gl p h