ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9404050253 DOC.DATE: 94/03/25 NOTARIZED: NO DOCKET FACIL:STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 AUTH.NAME AUTHOR AFFILIATION KRAINIK,A.K.

Arizona Public Service Co.

(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

R

SUBJECT:

Forwards rev 1 to Unit 2,Cycle 5,COLR,effective on 940319.

I COLR modifies Linear Heat Rate in COLR section 3.2.1 from kW/ft to 13.5kW/ft as result of LOCA reanalysis w/increased D

number of plugged SG tubes.

S DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR / ENCL f SIKE:

TITLE: OR Submittal:

General Distribution

/

NOTES:Standardized plant.

RECIPIENT ID CODE/NAME PDV LA HOLIAN, B INTERNAL: ACRS NRR/DORS/OTSB NRR/DRPW NRR/DSSA/SRXB O~C~PBeB IL 01 EXTERNAL: NRC PDR COPIES LTTR ENCL 1

1 2

2 6

6 1

1 1

1 1

1 1

0 1

1 1

1 RECIPIENT ID CODE/NAME PDV PD TRAN,L NRR/DE/EELB NRR/DRCH/HICB NRR/DSSA/SPLB NUDOCS-.ABSTRACT OGC/HDS1 NSIC COPIES LTTR ENCL 1

1 2

2 1

1 1

1 1

1 1

1 1

0 1

1 05000529 A

D D

D NOTE TO ALL"RIDS" RECIPIENTS:

D D

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 24 ENCL 22

l

Arizona Public Service Company PALO VERDE NUCLEAR GENERATING STATION P.O. BOX 52034

~

PHOENIX, ARIZONA85072-2034 102-02879-AKK/RAB/6EC March 25, 1994 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555

Dear Sirs:

Subject:

Palo Verde Nuclear, Generating Station (PVNGS)

Unit 2 Docket No. STN 50-529 Submittal of Revision 1 to Unit 2, Cycle 5, Core Operating Limits Report File: 94-005-41 9.05 94-056-026 Pursuant to PVNGS Unit 2 Technical Specification 6.9.1.10, enclosed is a copy of Revision 1 to the Unit 2, Cycle 5, Core Operating Limits Report (COLR). Revision 1 to the Unit 2, Cycle 5, COLR was effective on March 19, 1994.

As required by Specification 6.9.1.10, a copy of the COLR submittal is being forwarded to the NRC Region V Administrator and the Resident Inspector.

Revision 1 to the Unit 2, Cycle 5, COLR modifies the Linear Heat Rate in COLR Section 3.2.1 from 13.5 kW/ftto 13.2 kW/ftas a result of loss-of-coolant accident (LOCA) reanalysis with an increased number of plugged steam generator tubes.

Should you have any questions, please contact Richard A. Bernier at (602) 393-5882.

Sincerely, Angela K. Krainik, Manager Nuclear Licensing AKK/RAB/6EC/dd Enclosure 9454050253 940328 "

PDR ADOt"K 05000529 i

PDR'

j w4kP

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk, Revision 1 to Unit 2, Cycle 5, Core Operating Limits Report Page 2 cc:

W. F. Conway K. E. Perkins, Jr.

K. E. Johnston B. E. Holian (all w/enclosure)

If IN t

I