Text
REGULAT Y INFORMATION DISTRIBUTION 'YSTEM (RIDS>
ACCESSION NOR: 8709170219 DOC. DATE: 87/O'V/14 NOTARIZED:
NO FACIL:STN-50-529'alo Verde Nuclear Station>
Unit 2i Arizona Pub li STN-50-530 Palo Verde Nuclear Station>
Unit 3i Arizona Publi AUTH. NAME AUTHOR AFFILIATION HAYNES> J. G.
Ar i zona Nuclear Power Prospect (formerly Ari.zona Public Berv RECIP. NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Application for amends to Licenses NPF-51 5 NPF-65i changing max enrichment in Fuel assemblies from 4. 0 / U-235 to 4. 05/.
DISTRIBUTION CODE:
A001D COPIES RECEIVED: LTR l
ENCL g SIZE:
TITLE:
OR Submittal:
General Distribution NOTES: Standardized plant.
Standardi zed p lant.
05000529 05000530 RECIPIENT ID CODE/NAME PD5 LA LICITRAa E INTERNAL: ACRS NRR/DEBT/ADB NRR/DEBT/MTB NRR/DOEA/TSH OGC/HDS1 RES/DE/EIB EXTERNAL:
EGSG HRUBKEi S NRC PDR COPIES LTTR ENCL 1
0 1
1 6
1 1
1 1
1 1
0 1
1 1
1 1
RECIPIENT ID CODE/NAME PD5 PD DAVIS' ARM/DAF/LFMB NRR/DEBT/CEB NRR/DEBT/RBB NRR/PMAS/ ILRB 01 LPDR NSIC COP IES LTTR ENCL 5
5 1
1 0
1 1
1 1
1 1
1 1
1 NOTES:
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 29 ENCL 26
Arizona Nuclear Power Project P.O. BOX 52034
~
PHOENIX. ARIZONA85072-2034 161-00500-JGH/LJM September 14, 1987 UPS. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Unit 2 and 3
Docket No.
STN 50-529 (License NPF-51)
STN 50-530 (License NPF-65)
Reload Technical Specification Amendment File: 87-F-005-419.05 87-C-056-026 87-F-056-026
Dear Sir:
Attached please find proposed changes to the PVNGS Unit 2
and 3
Technical Specifications.
The amendment request addresses changing the maximum enrichment in fuel assemblies from 4.0 weight percent U-235 to 4.05 weight percent.
This change is a result of the final Cycle 2 fuel management core design.
- Enclosed, with this amendment request
- package, are the following:
A.
B.
C.
D.
E.
F.
G.
Description of the Technical Specification Amendment Request.
Purpose of the Technical Specification.
Need for the Technical Specification Amendment.
Basis for Proposed No Significant Hazards Consideration Determination.
Safety Analysis for the Amendment Request.
Environmental Impact Consideration Determination.
Marked-up Technical Specification Change Pages.
By copy of this
- letter, we are also forwarding the proposed changes to the appropriate state agency.
In accordance with the requirements of 10 CFR 170.12(c),
the license amendment application fee of $150.00 has been forwarded to the U.S.
NRC License Fee Management Coordinator.
~ 8709l.70219 870914 t"
1 PDR ADOCK 05000529 r DR/.
l 1
t 1'
USNRC Document Control Desk Reload'echnical Specification Amendment 161- 00500 Page 2
If you have any questions, please call W. F. Quinn at (602) 371-4087.
Very truly yours, J.
G. Haynes Vice President Nuclear Production JGH/LJM/ls Attachments
(~/~150 ~fd) cc:
0.
M. De Michele E. E.
Van Brunt, Jr.
G.
W. Knighton J.
R. Ball.
J.
B. Martin E. A. Licitra (w/a)
A. C. Gehr C. E. Tedford R.
M. Diggs
fj Pf
ATTACHMENT A.
DESCRIPTION OF THE TECHNICAL SPECIFICATION AMENDMENT RE<EUEST The proposed amendment increases the maximum enrichment from 4.0 to 4.05 weight percent U-235 as set forth in Technical Specification (T.S.) 5.3.1.
B.
PURPOSE OF THE TECHNICAL SPECIFICATION T.S. 5.3.1 describes the core by way of the number of fuel assemblies, the length of the fuel rods and the weight of the fuel rods.
It identifies the physical properties of the rods, fuel and burnable
- poison, contained within a
bundle.
The T.S. states the maximum allowable enrichment of U-235.
C.
NEED FOR THE TECHNICAL SPECIFICATION AMENDMENT To support the desired fuel management design of Cycle 2 and to allow future 18-month equilibrium cycles, the maximum peak pin enrichment as stated in T.S.
5.3.1 will be increased to the value of 4.05, weight percent U-235.
By increasing the enrichment to 4;05 PVNGS will be able to meet the long term goal of 18 month equilibrium cycles without adversely affecting safety margins.
D.
BASIS FOR PROPOSED NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION 1.
The Commission has provided standards for determining whether a
significant hazards consideration exists as stated in 10 CFR 50.92.
A proposed amendment to an operating license for a facility involves no significant hazards consideration if operation of the facility in accordance with a proposed amendment would not: (1) Involve a significant increase in the probability or consequences of an accident previously evaluated; or (2)
Create the possibility of a new or different kind of accident from any accident previously evaluated; or (3)
Involve a
significant reduction in a margin of safety.
A discussion of these standards as they relate to the amendment request follows:
Standard 1Involve a
significant increase in the probability or consequences of an accident previously evaluated.
The proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
Increasing the maximum allowed enrichment to 4.05 weight percent affects the criticality analysis for New Fuel Storage and Spent Fuel Storage.
The FSAR references the results of the existing criticality analyses for a
maximum enrichment of 4.3 wtX.
The results of the analysis for 4.05 enrichment shows that the K ff for new fuel storage/handling is still less than the limit of 0.98 as required by T.S. 5.6.1.2 and for spent fuel eff
t
of the analysis for 4.05 enrichment shows that the K f s, the limiting value set forth by the T.S. for both New Fuel and Spent Fuef storage,are still less than the limits of 0.98 and 0.95 respectively.
Therefore, the probability of occurrence or the consequences of an accident or malfunction of equipment important to safety previously evaluated
'in the FSAR will not be increased.
The proposed Technical Specification amendment will not create the possibility for an accident or malfunction'f a different 'ype than any previously evaluated in the FSAR.
The proposed change does not alter the configuration of the plant or the way in which it is operated.
Therefore, the possibility of a
different accident or malfunction will not be created.
The proposed Technical Specification amendment will not reduce the margin of safety as defined in the basis for the Technical Specifications.
The analysis performed for the proposed change shows that, for an enrichment of 4.05 wtX the results are still conservative with respect to the criteria set forth by Technical Specifications.
Therefore, the margin of safety is maintained.
F.
ENVIRONMENTAL IMPACT CONSIDERATION DETERMINATION The proposed change request does not involve an unreviewed environmental question because operation of PVNGS Units 2 and 3, in accordance with this
- change, would not:
1.
Result in a
significant increase in any adverse environmental impact previously evaluated in the Final Environmental Statement (FES) as modified by the staff's testimony to the Atomic Safety and Licensing Board; or 2.
Result in a significant change in effluents or power levels; or 3.
Result in matters not previously reviewed in the licensing basis for PVNGS which may have a significant environmental impact.
G.
MARKED-UP TECHNICAL SPECIFICATION CHANGE PAGES Limiting Conditions For Operation And Surveillance Requirements.
5-5
t