ML17279A189

From kanterella
Jump to navigation Jump to search
Forwards Comparison of Electrical Design of Wye Pattern Globe Valve Actuator W/Ball Valve,Hanford 2 & River Bend Design, for Use & Info
ML17279A189
Person / Time
Site: Nine Mile Point, Columbia, River Bend, 05000000
Issue date: 04/07/1987
From: Mangan C
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17279A190 List:
References
(NMP2L-1019), NUDOCS 8704130437
Download: ML17279A189 (6)


Text

REQULATO NFORNATION DISTRIBUTION TTEN <RIDS) o

-ACCESSION NBR: 8704130437 DOC. DATE: 87/04/07 NOTARIZED: YES DOCXET e FAG IL:50-000 Generic Doc ket 05000000 50-397 MPPSS Nuclear Prospect Unit 2 Nash ington Public Pore 05000397 50-410 Nine Nile Point Nuclear Station>

Unit 2> Niagara aloha 05000410 50-458 River Bend Stations Unit 11 Gulf States Utilities Co.

05000458 AUTH. NANE AUTHOR AFFILIATION NANQAN> C. V.

Niagara Mohawk Poser Corp.

gCC. IO~

RECIP. NAl'1E RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards "Comparison of Electrical Design of Wge Pattern Globe Valve Actuator M/Bali Valvei Hanford 2 Zc River Bend Design." for use h info.

DISTRIBUTION CODE:

AOOID COPIEB RECEIVED: LTR I ENCL /

SIZE: R~S TITLE:

OR Submittal:

General Distribution NOTES:

QhJTER NAL:

RECIPIENT ID CODE/NAl'lE PD5 L*

PD4 LA PD1-1 PD SANWORTH R

llINERi8 ACRS NRR/DEBT/ADE NRR/DLPG/HFB NRR/Pl'fAS/ILRB OQC/HD81 COPIES LTTR ENCL 0

1 0

5 5

1 1

1 h

6 1

1 1

1 1

0 RECIPIENT ID CODE/NAME PD1-1 L*

PD5 PD PD4 PD HAUGHEY> M STERNI 8 ADN/LFNB NRR/DEST/ADS MRR/DOEA/TSB

-8 82 REG FI 01 COPIES LTTR ENCL 1

0 5

5 5

5 1

1 1

1 0

1 1

1 0

1 1

EXTERNAL:

EQSQ BRUSKEi 8 NRC PDR 1

1 1

LPDR NSlC

~c~i A. cyz. 7> ~ ~

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 44 ENCL 38

Ik

,~ [

l

NIAGARAMOHAWKPOWER CORPORATION/301 PLAINFIELOROAD, SYRACUSE, N.Y. 13212/TELEPHONE (315) 474-1511 8704130437 870407 PDR

  • DOCK 050003'P7' PDR April 7, 1987 (NMP2L 1019)

U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Re:

Nine Mile Point Unit 2 Docket No. 50-410 Gentlemen:

Enclosed for your use and information is a report that compares the electrical design of the Nine Mile Point Unit 2 wye pattern globe valve presently being installed with the ball valve design.

The report also compares the wye pattern globe valve electrical'design for Unit 2 with the Hanford 2 and River Bend electrical design.

This information was discussed with the Nuclear Regulatory Commission staff on April 2,

1987, and is provided to support review of the wye pattern globe valve design.

For your information, there is no restriction on copying any of the drawings included in this submittal.

If there are questions, please contact Mr. lallnick of my staff.

Very truly yours, NIAGARA MOHAWK POWER CORPORATION C. V. Mang Senior Vice President NLRlpns 2976G Enclosure xc:

Regional Administrator, Region I Ms.

E.

G. Adensam, Project Director Mr.

W. A. Cook, Resident Inspector Project File (2)

/t d(lL

>%hah ggd '

0 II

'V

,y 1

N l

)i

'l I

ll

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Hatter of l

l Niagara Mohawk Power Corporation

]

]

(Ni ne Mile Po I n t Unit 2) l Docket No. 50-410 AFFIOAVIT C. V. Han an

, being duly sworn, states that he is Senior Vice President of Niagara Mohawk Power Corporation; that he is authorized on the part of said Corporation to sign and file with the Nuclear Regulatory Commission the documents attached hereto; and that al.l such documents are true and correct to the best of his knowledge, information and belief.

, 1987.

Subscribed and sworn to before me, a Notary Public in and for the State of New York and County of

, this 7

day of Notary Public in and for

County, New York Hy Commission expires:

MAP( FBATESCHI Notary Public In the State of New Yorrr Quelllled In Onondaga County No. 4797550 LlyCommlselon Explroa March 3'9gg

0 P,

f