EXPORT LICE NSE NRC FORM 250 (10-07)

UNITED STATES OF AMERICA Nuclear Regulatory Commission Washington, D.C. 20555 NRC LICENSE NO.; PXB17b.11 Page 1 of 3 NRC DOCKET NO.: 11006200 LICENSE EXPIRES: September 30, 2019 Pursuant to the Atomic Energy Act of 1954, as amended, and the regulations issued by the Nuclear Regulatory Commission (NRC) pursuant thereto, and in reliance on statements and representations heretofore made by the applicant/licensee, this license is hereby issued authorizing the licensee to export the byproduct materials listed below, subject to the terms and conditions herein. This license is only valid if the licensee or 'Other Party(ies) to Export' maintain the requisite NRC or Agreement State domestic license(s).

LICENSEE Industrial Nuclear Company 14320 Wicks Blvd San Leandro, California 94577 Attn: Mike Rose ULTIMATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)

See 'Country(ies) of Ultimate Destination' INTERMEDIATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)

None OTHER U.S. PARTY(IES) TO EXPORT Industrial Nuclear Company 300 Highway 146 North La Porte, Texas 77571 (alternate license address)

APPLICANT'S REFERENCE NO.: CA 2229-01 ULTIMATE DESTINATION: See page 2 CONDITIONS. NOTES, AND DESCRIPTIONS OF 10 CFR PART 110, APPENDIX P, BYPRODUCT MATERIALS TO BE EXPORTED (NOTE: SEE PAGE 3 FOR DEFINITIONS OF CATEGORY 1 AND CATEGORY 2)

Export, to countries listed in 'Country(ies) of Ultimate Destination' of Category 2 quantities of lr-192, Se-75 and Co-60 contained in sealed sources, not to exceed 5.55 TBq, for use in industrial radiography and for the development of custom design, is authorized, Licensee is responsible for compliance with all applicable export, and other domestic regulatory requirements, including all terms and conditions of domestic material possession licenses. Licensee, if not already submitted with your application, must submit information required by 10 CFR § 110.32(d) and pertinent documentation required by 10 CFR § 110.32(g) at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shipment. See Page 3 for Mandatory Pre-shipment Notifications.

This license replaces PXB17b.10 and amends its authority by: 1) adding Oman to the 'Country(ies) of Ultimate Destinations' list; and 2) extending the expiration date from May 31, 2018 until September 30, 2019.

Neither this license nor any right under this license shall be assigned or otherwise transferred in violation of the provisions of the Atomic Energy Act of 1954, as amended.

This license Is subject to the right of recapture or control by Section 108 of the Atomic Energy Act of 1954, as amended, and to all of the other provisions of said Acts, now or hereafter in effect and to all valid rules and regulations of the NRC.

THIS LICENSE IS INVALID UNLESS SIGNED BELOW BY AUTHORIZED NRC REPRESENTATIVE SIGNATURE:

NAME AND TITLE:

DATE OF ISSUANCE:

David L, Skeen, Deputy Director Office of International Programs September 28, 2017 EXPORT LICENSE

PXB17b.11 Page 2 of 3 COUNTRY(IES) OF ULTIIVIATE DESTINATION(S):

Algeria, Armenia, Azerbaijan. Bahamas, Bahrain, Brunei, Colombia. Comoros, Costa Rica, Cote d'lvoire, Croatia, Cyprus, Dominican Republic. Ecuador, Egypt, Ei Salvador, Equatorial Guinea, Gabon, Ghana, Guatemala, Guyana, Haiti, Holy See, Honduras, Iceland, India, Indonesia, Israel, Jamaica, Jordan, Kenya, Kuwait, Malaysia, Mauritania, Morocco, Mozambique, Niger, Nigeria, Oman, Panama, Paraguay, Peru, Saint Lucia, Saudi Arabia, Suriname, Trinidad and Tobago, Tunisia, Turkmenistan, Ukraine, Uruguay and Venezuela iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiinEmiiiiiiiiiiiiiiitiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiniiiniiiiiiiiiiiiiiii

MANDATORY ADVANCED NOTIFICATIONS PER 10 CFR PART 110.50(c)

PXB17b.11 Page 3 of 3 The following Advanced Notifications must be made to both the NRC and, in case of exports, the government of the Importing country in advance of each shipment:

Advanced Notifications to the NRC are to be emailed to hoo.hoc@nrc.Qov (preferred method) or faxed to the NRC at 301-816-5151. In the subject line of the email or on the fax cover page include: "10 CFR 110.50(c) Notification."

For technical assistance, use the same e-mail address or call 301-816-5100.

Advanced Notifications to the government of the importing country must be emailed or faxed to the appropriate foreign government authorities. To locate the point-of-contact for international Prior Shipment Notifications see:

http://wv,fw-ns.iaea.orQ/downloads/rw/imD-exDort/imDort-export-contact-Doints.Ddf. In the subject line of the email or on the fax cover page include: "NOTIFICATION TO THE IMPORTING STATE PRIOR TO SHIPMENT OF CATEGORY 1 OR 2 RADIOACTIVE SOURCES." For technical assistance or for countries not listed, contact the Office of International Programs' export/import staff at 301-287-9056.

Table 1: Appendix P to Part 110 Cateqorv 1 and Category 2 Radioactive Material Threshold Limits Radioactive Category 1 Category 2 Material Terabequerels (TBq)

Curies (Ci)^

Terabequerels (TBq)

Curies(Ci)^

Amerlcium-241 (Am-241) 60 1,600 0.6 16 Americium-241/Be:yllium (Am-241/Be) 60 1,600 0.6 16 Californium-252 (Cf-252) 20 540 0.2 5.4 Cufium-244 (Cm-244) 50 1,400 0.5 14 Cobalt-60 (Co-eO) 30 810 0.3 8.1 Cesium-137 (Cs-137) 100 2,700 1.0 27 Gadolinium-153 (Gd-153) 1,000 27,000 10.0 270 lridium-192 {lr-192) 80 2,200 0.8 22 Plutonium-2382 (Pu-238) 60 1,600 0.8 16 Plutonium-239/Bervllium^(Pu-239/Be) 60 1,600 0.6 16 Promethium-147 (Pm-147) 40,000 1,100,000 400 11,000 Radium-226^ (Ra-226) 40 1,100 0.4 11 Selenium-75 (Se-75) 200 5,400 2.0 54 Strontium-90 (Y-90) 1,000 27,000 10.0 270 Thulium-170 (Tm-170) 20,000 540,000 200 5,400 Ytterbium-169 (Yb-169) 300 8,100 3.0 81 Calculation of Shipments Containing Multiple Sources or Radionuclides:

The "sum of fractions" methodology for evaluating combinations of radionuclides being transported is to be used when import or export shipments contain multiple sources or multiple radionuclides. The threshold limit values used in a sum of the fractions calculation must be the metric values (i.e., TBq).

I. If multiple sources and/or multiple radionuclides are present in an import or export shipment, the sum of the fractions of the activity of each radionuclide must be determined to verify the shipment is less than the Category 1 or 2 limits of Table 1, as appropriate. If the calculated sum of the fractions ratio, using the following equation, is greater than or equal to 1.0, then the Import or export shipment exceeds the threshold limits of Table 1 and the applicable security provisions of this part apply.

II. Use the equation below to calculate the sum of the fractions ratio by inserting the actual activity of the applicable radionuclides or of the individual sources (of the same radionuclides) in the numerator of the equation and the corresponding threshold activity limit from the Table 1 in the denominator of the equation. Ensure the numerator and denominator values are in the same units and ali calculations must be performed using the TBq (i.e., metric) values of Table 1.

R1 = activity for radionuclides or source number 1 R2 = activity for radionuclides or source number 2 RN = activity for radionuclides or source number n Ri z

+

AR1 = activity limit for radionuclides or source number 1 AR2 = activity limit for radionuclides or source number 2 ARN = activity limit for radionuclides or source number n R2 R,,

1

+

ARi AR2 AR..

^ The values to be used to determine whether a license is required are given in TBq. Curie (Gi) values are provided for practical usefulness only and are rounded after conversion.

2 The limits for exports of Pu-238 and Pu-239/Be can be found in § 110.21.

2 Discrete sources of Radium-226.