MONTHYEARML17241A4441999-08-18018 August 1999 Application for Amend to License NPF-16,to Change Required Surveillance Frequency for Cycling Steam Valves in Turbine Overspeed Protection Sys from Once Per Month to Once Per Quarter (92 Days).Proprietary Encls Withheld ML17241A3521999-06-0101 June 1999 Application for Amends to Licenses DPR-67 & NPF-16,revising TS 3.5.2 to Allow Up to 7 Days to Restore Inoperable LPSI Train to Operable Status ML17241A3431999-05-24024 May 1999 Application for Amend to License NPF-16,revising Unit 2 TS 3/4.5.1, Safety Injection Tanks, by Clarifying Nonconservative Wording of Surveillance 4.5.1.1.d.1 to Align Surveillance with Intent & Design Bases Requirements ML17229B0181999-02-23023 February 1999 Application for Amend to License NPF-16,removing Redundant Concentration Monitoring Requirements Specified for Modes 3 Through 6 by Deleting TS 3/4.1.2.9, Reactivity Control Sys- Boron Dilution. ML17229A9541998-12-16016 December 1998 Application for Amends to Licenses DPR-67 & NPF-16,revising Administrative Controls TS 6.3, Unit Staff Qualifications & Incorporating Specific Staff Qualifications for Multi- Discipline Supervisor Position ML17229A9221998-11-22022 November 1998 Application for Amend to License DPR-67,revising Thermal Margin SL Lines of TS Figure 2.1-1 to Reflect Increase in Value of Design Min RCS Flow from 345,000 Gpm to 365,000 Gpm & Change Flow Rates Stated in Tables 2.2-1 & 3.2-1 ML17229A9111998-11-19019 November 1998 Application for Amends to Licenses DPR-67 & NPF-16,revising Administrative Controls TS 6.3, Unit Staff Qualifications & Incorporate Specific Staff Qualifications for Multi-Discipline Supervisor (MDS) Position ML17229A8421998-08-24024 August 1998 Application for Amends to Licenses DPR-67 & NPF-16,removing Obsolete License Conditions & Incorporating Attached TS Revs ML17229A7581998-06-0303 June 1998 Application for Amends to Licenses DPR-67 & NPF-16 to Incorporate Attached TS Revs.Proposed Amends Are Administrative in Nature & Will Modify Explosive Gas Mixture Surveillance Requirement 4.11.2.5.1 ML17229A7461998-05-27027 May 1998 Application for Amend to License NPF-16,removing Requirement for SITs to Be Operable in Mode 4,which Will Minimize Potential for Inadvertent SIT Discharge During RCS Cooldown/ Depressurization Evolutions ML17229A7491998-05-27027 May 1998 Application for Amends to Licenses DPR-67 & NPF-16,revising TS 6.2.2.f to Allow Use of Longer Operating Shifts of Up to Twelve Hours Duration by Plant'S Operating Crews ML17229A7421998-05-27027 May 1998 Supplemental Application to 961031 Proposed Amend to Licenses DPR-67 & NPF-16,providing for More Efficient Use of on-site Mgt Personnel in Review & Approval Process for Plant Procedures ML17229A6481998-03-0303 March 1998 Application for Amend to License NPF-16,revising Applicability of TS 3.4.7 Re RCS Chemistry,Consistent W/ Corresponding Specification for Unit 1 ML17309A9161997-12-31031 December 1997 Application for Amend to License NPF-16 by Incorporating Attached TS Rev.Amend Will Modify TS 5.6.1 & Associated Figure 5.6-1 & TS 5.6.3 to Accomodate Increase in Allowed SFP Storage Capacity ML17309A9111997-12-29029 December 1997 Application for Amend to License NPF-16,modifying Specifications for Selected cycle-specific Reactor Physics Parameters to Provide Reference to St Lucie Unit 2 COLR for Limiting Values ML17229A5471997-12-0101 December 1997 Application for Amends to Licenses DPR-67 & NPF-16,revising EPP Section 4, Environ Conditions & Section 5, Administrative Procedures, to Incorporate Proposed Terms & Conditions of Incidental Take Statement ML17229A4601997-08-22022 August 1997 Application for Amends to Licenses DPR-67 & NPF-16,revising Specification 4.0.5,Surveillance Requirements for ISI & Testing of ASME Code Class 1,2 & 3 Components,To Relocate IST Program Requirements to Administrative Controls Section ML17229A4321997-08-0101 August 1997 Application for Amend to License NPF-16,extending semi- Annual Surveillance Interval Specified in Table 4.3-2 for Testing ESFAS Subgroup Relays to Interval Consistent W/Ceog Rept CEN-403,Rev 1-A for March 1996 ML17229A4211997-07-22022 July 1997 Application for Amend to License DPR-67,incorporating Recent Evaluation of Postulated Inadvertent Opening of MSSV Into Current Licensing Basis ML17229A3581997-05-29029 May 1997 Application for Amends to Licenses DPR-67 & NPF-16, Incorporating Administrative Changes That Will Improve Consistency Throughout TSs & Related Bases ML17229A1811996-12-20020 December 1996 Application for Amend to License DPR-67,requesting Deletion of Footnote Re TS 2.1.1, Reactor Core Safety Limits. ML17229A1591996-12-0909 December 1996 Application for Amend to License DPR-67,requesting Mod for Selected cycle-specific Reactor Physics Parameters to Refer to COLR for Limiting Values ML17229A1171996-10-31031 October 1996 Application for Amends to Licenses DPR-67 & NPF-16, Requesting Revisions to 6.5.1 Re Facility Review Group & 6.8 Re Procedures & Programs ML17339A0431996-10-30030 October 1996 Application for Amends to Licenses DPR-67 & NPF-16, Requesting to Revise TS 3/4.9.9 Re Refueling Requirements & TS 3/4.9.10 Re Refueling Operations,Water level-reactor Vessel ML17229A1071996-10-28028 October 1996 Application for Amend to License NPF-16,modifying TS to Implement 10CFR50,App J,Option B,To Revise TS to Allow Type A,B & C Containment Leakage Tests to Be Conducted at Extended Intervals Determined by performance-based Criteria ML17229A1041996-10-28028 October 1996 Application for Amend to License DPR-67,requesting to Allow Type A,B & C Containment Leakage Tests to Be Conducted at Extended Intervals Determined by performance-based Criteria ML17228B5621996-07-15015 July 1996 Application for Amends to Licenses DPR-67 & NPF-16 Revising Core Alteration Definition ML17228B5021996-06-0101 June 1996 Application for Exigent Amend to License DPR-67,revising TS Re Thermal Margin & RCS Flow Limits.Siemens Power Corp Rept EMF-96-135, St Lucie Unit 1 Chapter 15 Event Review & Analysis for 30% SG Tube Plugging Encl ML17228B3741996-01-0404 January 1996 Application for Amends to Licenses DPR-67 & NPF-16 Revising TS 3.5.3 to Rectify Discrepancy for Each St Lucie Unit & to Provide Assurance That Admin Controls for Hpsip Remain Effective in Lower Operational Modes ML17228B3341995-11-22022 November 1995 Application for Amends to Licenses DPR-67 & NPF-16,amending TS 3/4.4.6.1 for RCS Leakage Detection Instrumentation by Adapting STS for C-E Plants (NUREG-1432),Spec 3.4.15 for Facilities ML17228B2861995-10-0505 October 1995 Application for Amends to Licenses DPR-67 & NPF-16,removing SR Re Dune & Mangrove Surveys from TS ML17228B2401995-08-16016 August 1995 Application for Amends to Licenses DPR-67 & NPF-16, Relocating Selected TS Requirements Re Instrumentation,Per Final Policy Statement on TS Improvements & Relocating TS Re Emergency & Security Plan Review Process Per GL 93-07 ML17228B2431995-08-16016 August 1995 Application for Amend to License NPF-16,modifying Spec 3.6.6.1, Sbvs to More Effectively Address Design Functions Performed by Sbvs for Shield Bldg & Fuel Handling Bldg,Per NUREG-1432 ML17228B1871995-06-21021 June 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Revise Action Statements & Certain Surveillances of TS 3/4.5.1 Re Safety Injection Tanks ML17228B1771995-06-21021 June 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Extend Allowed Outage Time for Inoperable EDGs ML17309A7921995-06-21021 June 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Allow Up to Seven Days to Restore an Inoperable LPSI Train to Operable Status ML17228B1451995-05-17017 May 1995 Application for Amend to License DPR-67,extending Applicability of Current RCS Pressure/Temp Limits & Maximum Allowed RCS Heatup & Cooldown Rates to 23.6 Effective Full Power Yrs of Operation ML17228B1421995-05-17017 May 1995 Application for Amends to Licenses DPR-67 & NPF-16 Re Administrative & Conforming Update ML17228B0881995-04-0303 April 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Incorporate line-item TS Improvements to TSs 3/4.8.1 & 4.8.1.2.2 ML17228B0571995-02-27027 February 1995 Application for Amend to License NPF-16,modifying Surveillance Requirement 4.9.8.1 & 4.9.8.2 to Allow Reduction in Required Min Shutdown Cooling Flow Rate Under Certain Conditions During Operational Mode 6 ML17228B0501995-02-27027 February 1995 Application for Amend to License NPF-16,revising TS Tables 3.3-3 & 3.3-4 to Accommodate Improved Coincidence Logic & Relay Replacement for 4.16 Kv Loss of Voltage Relay ML17228B0311995-02-22022 February 1995 Application for Amends to Licenses DPR-67 & NPF-16,deleting Refs to Automatic Tester for Containment Personnel Air Lock from TS 4.6.1.3 ML17228A9901995-01-20020 January 1995 Application for Amends to Licenses DPR-67 & NPF-16, Relocating Operability Requirements for Incore Detectors (TS 3/4.3.3.2) to Updated FSAR & Revising Lhr Surveillance 4.2.1.4 & Special Test Exceptions Surveillances ML17352B0001995-01-17017 January 1995 Application for Amends to Licenses DPR-31 & DPR-41,revising TS 6.9.1.7, COLR, Re Implementation of FPL Nuclear Physics Methodology for Calculations of COLR Parameters.Fpl Topical Rept NF-TR-95-01, Nuclear Physics Methodology... Encl ML17228A9011994-11-0202 November 1994 Application for Amends to Licenses DPR-67 & NPF-16,upgrading TS 3/4.6.2.1 & 3/4.6.2.3 by Adapting Combined Spec for Containment Spray & Cooling Sys Contained in Std TS for C-E Plants ML17309A7511994-10-27027 October 1994 Application for Amends to Licenses DPR-67 & NPF-16, Incorporating Encl Administrative Changes ML17228A6501994-07-28028 July 1994 Application for Amends to Licenses DPR-67,revising TS 3/4.4.13 to Incorporate LTOP Requirements Similar to LTOP Requirements Recommended by NRC Via GL 90-06,in Accordance W/Resolution of Generic Issue 94 ML17228A6571994-07-25025 July 1994 Application for Amends to Licenses DPR-67 & NPF-16,revising Ts,Implementing Enhancements Recommended by GL 93-05 Re line-item TS Improvements to Reduce SR for Testing During Power Operation. ML17228A6541994-07-25025 July 1994 Application for Amend to License NPF-16,proposing TS Upgrading TS 3/4.7.1.6 for Main Feedwater Line Isolation Valves to Be Consistent w/NUREG-1432,standard TS for C-E Plants ML17228A5751994-05-23023 May 1994 Application for Amend to License DPR-67,revising TS 3.5.2 for ECCS by Removing Option That Allows HPSI Pump 1C to Be Used as Alternative to Preferred Pump for Subsystem Operability 1999-08-18
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML17241A4441999-08-18018 August 1999 Application for Amend to License NPF-16,to Change Required Surveillance Frequency for Cycling Steam Valves in Turbine Overspeed Protection Sys from Once Per Month to Once Per Quarter (92 Days).Proprietary Encls Withheld ML17241A3521999-06-0101 June 1999 Application for Amends to Licenses DPR-67 & NPF-16,revising TS 3.5.2 to Allow Up to 7 Days to Restore Inoperable LPSI Train to Operable Status ML17241A3431999-05-24024 May 1999 Application for Amend to License NPF-16,revising Unit 2 TS 3/4.5.1, Safety Injection Tanks, by Clarifying Nonconservative Wording of Surveillance 4.5.1.1.d.1 to Align Surveillance with Intent & Design Bases Requirements ML17229B0181999-02-23023 February 1999 Application for Amend to License NPF-16,removing Redundant Concentration Monitoring Requirements Specified for Modes 3 Through 6 by Deleting TS 3/4.1.2.9, Reactivity Control Sys- Boron Dilution. ML17229A9541998-12-16016 December 1998 Application for Amends to Licenses DPR-67 & NPF-16,revising Administrative Controls TS 6.3, Unit Staff Qualifications & Incorporating Specific Staff Qualifications for Multi- Discipline Supervisor Position ML17229A9221998-11-22022 November 1998 Application for Amend to License DPR-67,revising Thermal Margin SL Lines of TS Figure 2.1-1 to Reflect Increase in Value of Design Min RCS Flow from 345,000 Gpm to 365,000 Gpm & Change Flow Rates Stated in Tables 2.2-1 & 3.2-1 ML17229A9111998-11-19019 November 1998 Application for Amends to Licenses DPR-67 & NPF-16,revising Administrative Controls TS 6.3, Unit Staff Qualifications & Incorporate Specific Staff Qualifications for Multi-Discipline Supervisor (MDS) Position ML17229A8421998-08-24024 August 1998 Application for Amends to Licenses DPR-67 & NPF-16,removing Obsolete License Conditions & Incorporating Attached TS Revs ML17229A7581998-06-0303 June 1998 Application for Amends to Licenses DPR-67 & NPF-16 to Incorporate Attached TS Revs.Proposed Amends Are Administrative in Nature & Will Modify Explosive Gas Mixture Surveillance Requirement 4.11.2.5.1 ML17229A7461998-05-27027 May 1998 Application for Amend to License NPF-16,removing Requirement for SITs to Be Operable in Mode 4,which Will Minimize Potential for Inadvertent SIT Discharge During RCS Cooldown/ Depressurization Evolutions ML17229A7491998-05-27027 May 1998 Application for Amends to Licenses DPR-67 & NPF-16,revising TS 6.2.2.f to Allow Use of Longer Operating Shifts of Up to Twelve Hours Duration by Plant'S Operating Crews ML17229A7421998-05-27027 May 1998 Supplemental Application to 961031 Proposed Amend to Licenses DPR-67 & NPF-16,providing for More Efficient Use of on-site Mgt Personnel in Review & Approval Process for Plant Procedures ML17229A6481998-03-0303 March 1998 Application for Amend to License NPF-16,revising Applicability of TS 3.4.7 Re RCS Chemistry,Consistent W/ Corresponding Specification for Unit 1 ML17309A9161997-12-31031 December 1997 Application for Amend to License NPF-16 by Incorporating Attached TS Rev.Amend Will Modify TS 5.6.1 & Associated Figure 5.6-1 & TS 5.6.3 to Accomodate Increase in Allowed SFP Storage Capacity ML17309A9111997-12-29029 December 1997 Application for Amend to License NPF-16,modifying Specifications for Selected cycle-specific Reactor Physics Parameters to Provide Reference to St Lucie Unit 2 COLR for Limiting Values ML17229A5471997-12-0101 December 1997 Application for Amends to Licenses DPR-67 & NPF-16,revising EPP Section 4, Environ Conditions & Section 5, Administrative Procedures, to Incorporate Proposed Terms & Conditions of Incidental Take Statement ML17229A4601997-08-22022 August 1997 Application for Amends to Licenses DPR-67 & NPF-16,revising Specification 4.0.5,Surveillance Requirements for ISI & Testing of ASME Code Class 1,2 & 3 Components,To Relocate IST Program Requirements to Administrative Controls Section ML17229A4321997-08-0101 August 1997 Application for Amend to License NPF-16,extending semi- Annual Surveillance Interval Specified in Table 4.3-2 for Testing ESFAS Subgroup Relays to Interval Consistent W/Ceog Rept CEN-403,Rev 1-A for March 1996 ML17229A4211997-07-22022 July 1997 Application for Amend to License DPR-67,incorporating Recent Evaluation of Postulated Inadvertent Opening of MSSV Into Current Licensing Basis ML17229A3581997-05-29029 May 1997 Application for Amends to Licenses DPR-67 & NPF-16, Incorporating Administrative Changes That Will Improve Consistency Throughout TSs & Related Bases ML17229A1811996-12-20020 December 1996 Application for Amend to License DPR-67,requesting Deletion of Footnote Re TS 2.1.1, Reactor Core Safety Limits. ML17229A1591996-12-0909 December 1996 Application for Amend to License DPR-67,requesting Mod for Selected cycle-specific Reactor Physics Parameters to Refer to COLR for Limiting Values ML17229A1171996-10-31031 October 1996 Application for Amends to Licenses DPR-67 & NPF-16, Requesting Revisions to 6.5.1 Re Facility Review Group & 6.8 Re Procedures & Programs ML17339A0431996-10-30030 October 1996 Application for Amends to Licenses DPR-67 & NPF-16, Requesting to Revise TS 3/4.9.9 Re Refueling Requirements & TS 3/4.9.10 Re Refueling Operations,Water level-reactor Vessel ML17229A1071996-10-28028 October 1996 Application for Amend to License NPF-16,modifying TS to Implement 10CFR50,App J,Option B,To Revise TS to Allow Type A,B & C Containment Leakage Tests to Be Conducted at Extended Intervals Determined by performance-based Criteria ML17229A1041996-10-28028 October 1996 Application for Amend to License DPR-67,requesting to Allow Type A,B & C Containment Leakage Tests to Be Conducted at Extended Intervals Determined by performance-based Criteria ML17228B5621996-07-15015 July 1996 Application for Amends to Licenses DPR-67 & NPF-16 Revising Core Alteration Definition ML17228B5021996-06-0101 June 1996 Application for Exigent Amend to License DPR-67,revising TS Re Thermal Margin & RCS Flow Limits.Siemens Power Corp Rept EMF-96-135, St Lucie Unit 1 Chapter 15 Event Review & Analysis for 30% SG Tube Plugging Encl ML17228B3741996-01-0404 January 1996 Application for Amends to Licenses DPR-67 & NPF-16 Revising TS 3.5.3 to Rectify Discrepancy for Each St Lucie Unit & to Provide Assurance That Admin Controls for Hpsip Remain Effective in Lower Operational Modes ML17228B3341995-11-22022 November 1995 Application for Amends to Licenses DPR-67 & NPF-16,amending TS 3/4.4.6.1 for RCS Leakage Detection Instrumentation by Adapting STS for C-E Plants (NUREG-1432),Spec 3.4.15 for Facilities ML17228B2861995-10-0505 October 1995 Application for Amends to Licenses DPR-67 & NPF-16,removing SR Re Dune & Mangrove Surveys from TS ML17228B2401995-08-16016 August 1995 Application for Amends to Licenses DPR-67 & NPF-16, Relocating Selected TS Requirements Re Instrumentation,Per Final Policy Statement on TS Improvements & Relocating TS Re Emergency & Security Plan Review Process Per GL 93-07 ML17228B2431995-08-16016 August 1995 Application for Amend to License NPF-16,modifying Spec 3.6.6.1, Sbvs to More Effectively Address Design Functions Performed by Sbvs for Shield Bldg & Fuel Handling Bldg,Per NUREG-1432 ML17228B1871995-06-21021 June 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Revise Action Statements & Certain Surveillances of TS 3/4.5.1 Re Safety Injection Tanks ML17228B1771995-06-21021 June 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Extend Allowed Outage Time for Inoperable EDGs ML17309A7921995-06-21021 June 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Allow Up to Seven Days to Restore an Inoperable LPSI Train to Operable Status ML17228B1451995-05-17017 May 1995 Application for Amend to License DPR-67,extending Applicability of Current RCS Pressure/Temp Limits & Maximum Allowed RCS Heatup & Cooldown Rates to 23.6 Effective Full Power Yrs of Operation ML17228B1421995-05-17017 May 1995 Application for Amends to Licenses DPR-67 & NPF-16 Re Administrative & Conforming Update ML17228B0881995-04-0303 April 1995 Application for Amends to Licenses DPR-67 & NPF-16.Amends Would Incorporate line-item TS Improvements to TSs 3/4.8.1 & 4.8.1.2.2 ML17228B0571995-02-27027 February 1995 Application for Amend to License NPF-16,modifying Surveillance Requirement 4.9.8.1 & 4.9.8.2 to Allow Reduction in Required Min Shutdown Cooling Flow Rate Under Certain Conditions During Operational Mode 6 ML17228B0501995-02-27027 February 1995 Application for Amend to License NPF-16,revising TS Tables 3.3-3 & 3.3-4 to Accommodate Improved Coincidence Logic & Relay Replacement for 4.16 Kv Loss of Voltage Relay ML17228B0311995-02-22022 February 1995 Application for Amends to Licenses DPR-67 & NPF-16,deleting Refs to Automatic Tester for Containment Personnel Air Lock from TS 4.6.1.3 ML17228A9901995-01-20020 January 1995 Application for Amends to Licenses DPR-67 & NPF-16, Relocating Operability Requirements for Incore Detectors (TS 3/4.3.3.2) to Updated FSAR & Revising Lhr Surveillance 4.2.1.4 & Special Test Exceptions Surveillances ML17352B0001995-01-17017 January 1995 Application for Amends to Licenses DPR-31 & DPR-41,revising TS 6.9.1.7, COLR, Re Implementation of FPL Nuclear Physics Methodology for Calculations of COLR Parameters.Fpl Topical Rept NF-TR-95-01, Nuclear Physics Methodology... Encl ML17228A9011994-11-0202 November 1994 Application for Amends to Licenses DPR-67 & NPF-16,upgrading TS 3/4.6.2.1 & 3/4.6.2.3 by Adapting Combined Spec for Containment Spray & Cooling Sys Contained in Std TS for C-E Plants ML17309A7511994-10-27027 October 1994 Application for Amends to Licenses DPR-67 & NPF-16, Incorporating Encl Administrative Changes ML17228A6501994-07-28028 July 1994 Application for Amends to Licenses DPR-67,revising TS 3/4.4.13 to Incorporate LTOP Requirements Similar to LTOP Requirements Recommended by NRC Via GL 90-06,in Accordance W/Resolution of Generic Issue 94 ML17228A6571994-07-25025 July 1994 Application for Amends to Licenses DPR-67 & NPF-16,revising Ts,Implementing Enhancements Recommended by GL 93-05 Re line-item TS Improvements to Reduce SR for Testing During Power Operation. ML17228A6541994-07-25025 July 1994 Application for Amend to License NPF-16,proposing TS Upgrading TS 3/4.7.1.6 for Main Feedwater Line Isolation Valves to Be Consistent w/NUREG-1432,standard TS for C-E Plants ML17228A5751994-05-23023 May 1994 Application for Amend to License DPR-67,revising TS 3.5.2 for ECCS by Removing Option That Allows HPSI Pump 1C to Be Used as Alternative to Preferred Pump for Subsystem Operability 1999-08-18
[Table view] |
Text
R10RXTY 3-(ACCELERATED RZDS -PROCESSING)
N REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9508210214 DOC.DATE: 95/08/16 NOTARIZED: YES DOCKET FACIL:50-389 St. Lucie Plant, Unit 2, Florida Power & Light Co. 05000389 P AUTH. NAME AUTHOR AFFILIATION SAGER,D.A. Florida Power & Light Co.
RECIP.NAME RECIPIENT AFFILIATION
'ocument Control Branch (Document Control Desk)
SUBJECT:
Application for amend to license NPF-16,modifying spec 3.6.6.1,Sheild Bldg ventilation sys to more effectively address design functions performed. by SBVS for Sheild-bldg j
Fuel Handling Bldg.
DISTRIBUTION CODE: AOOID COPIES RECEIVED:LTR ! ENCL SIZE:
TITLE: OR Submittal: General Distribution NOTES" RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-1 LA 1 1 PD2-1 PD 1 1 NORRIS,J 1 1 INTERNAL: ACRS '
E CEN~ 1 1 1 NRR/DE/EMCB 1 1 RR/DRCH/HICB 1 1 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 NUDOCS-ABSTRACT 1 1 OGC/HDS3 1 0 EXTERNAL NOAC' 1 1 NRC PDR 1 1 D 0
N NOTE TO ALL "RZDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESKI ROOM OWFN 5D8 (415 2083) TO ELIMINATE YOUR NAME FROM DISTRZBUTZON LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR 18 ENCL 17
i Florida Power 5 Light Company, P.O. Box128, Fort Pierce, FL34954.0128 August 16, 1995 L-95-215 10 CFR 50 '0 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: St. Lucie Unit 2 Docket No. 50-389 Proposed License Amendment Shield Buildin Ventilation S stem Pursuant to 10 CFR 50.90, Florida Power & Light Company (FPL) requests to amend Facility Operating License NPF-16 for St. Lucie Unit 2 by incorporating the attached Technical Specifications (TS) revisions. The revisions will modify Specification 3.6.6.1, Shield Building Ventilation System (SBVS), to more effectively address the design functions performed by the SBVS for both the Shield Building (secondary containment) and the Fuel Handling Building. Accounting for plant specific differences, the proposed changes are consistent with NUREG-1432, Standard Technical Specifications for Combustion Engineering Plants.
It by is requested that the proposed amendment, May 1, 1996.
if approved, be issued Attachment 1 is an evaluation of the proposed TS changes.
Attachment 2 is the "Determination of No Significant Hazards Consideration." Attachment 3 contains a copy of the appropriate TS pages marked-up to show the proposed changes.
The proposed amendment has been reviewed by the St. Lucie Facility Review Group and the Florida Power & Light Company Nuclear Review Board. In accordance with 10 CFR 50.91 (b)(1), a copy of the proposed amendment is being forwarded to the State Designee for the State of Florida.
Please contact us if there are any questions about this submittal.
Very truly yours, 484 D. A. ger Vice r sident St. Lucie Plant DAS/RLD Attachments .~ AA~iQ cc: See next page ~
9S08210214 950816 PDR ADOCK 05000385' an FPL Group company PDR
St. Lucie Unit 2 L-95-215 Docket No. 50-389 Page 2 Proposed License Amendment Shield Buildin Ventilation S stem cc: Stewart D. Ebneter, Regional Administrator, Region II, USNRC.
Senior Resident Inspector, USNRC, St. Lucie Plant.
Mr. W.A. Passetti, Florida Department of Health and Rehabilitative Services.
'I
% ~
'L I~
~ ~
~
gS St. Lucie Unit 2 L-95-215 Docket No. 50-389 Page 3 Proposed License Amendment Shield Buildin Ventilation S stem STATE OF FLORIDA )
) SS ~
COUNTY OF ST. LUCIE )
D. A. Sager being first duly sworn, deposes and says:
That he is Vice President, St. Lucie Plant for the Nuclear Division of Florida Power & Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.
D. A. ager STATE OF FLORIDA COUNTY-OF Sl- l t L The foregoing instrument was acknowledged before me this day of 19 Q5 by D.A. Sager, who is perso and who did take an oath.
lly known to me
(
Name My Commission Commission No.
expires CS-l
(" C 5'ill of Notary Public HID
- a..ti KAREN WEST MY COMMISSION 9 CO359928 APFII 18, 1998 ROROEO THRU TROY FARI EXPlAES SSURANOE, INO.
I
)
l I
>" ~ Kwf RIpk ~ $ )
yA ', I,rE I
I
~ ~
~ ~
St. Lucie Unit 2 Docket No. 50-389 Proposed License Amendment Shield Buildin Ventilation S stem ATTACHMENT 1
,EVALUATION OF PROPOSED TS CHANGES
~ )
1
~ ~
1 ~
St. Lucie Unit 2 L-95-215 Docket No. 50-389 Attachment 1 Proposed L'icense Amendment Page 1 of 5 Shield Buildin Ventilation S ste EVALUATIONOF PROPOSED TS CHANGES Introduction Florida Power and Light Company (FPL) proposes to revise the St. Lucie Unit 2 (PSL2)
Technical Specifications (TS) for the Shield Building Ventilation System (SBVS). The changes will clarify the Applicability and the Actions required by TS 3.6.6.1, and explicitly account for the dual purpose of the SBVS to perform design functions for both the Shield Building (secondary containment) and the Fuel Handling Building. The proposed changes are consistent with the generic specifications of NUREG-1432, Standard Technical Specifications for Combustion Engineering Plants, as they apply to single systems that would perform the same two safety functions independently.
Back round The St. Lucie Unit 2 containment system consists of a free-standing steel primary containment, and a reinforced concrete shield building that encloses the primary containment. The SBVS, consisting of two independent, redundant, full-capacity fan and filter subsystems (trains), is designed to collect and filter radioactive airborne fission products that may leak from the primary containment to the annulus formed by these structures in the event of a Loss of Coolant Accident (LOCA). Upon receipt of a Containment Isolation Actuation Signal (CIAS), the SBVS will automatically actuate to perform the fission product removal function that is assumed for the postulated LOCA. The system must be OPERABLE, but is not operating during normal operation of the plant.
Each train of the SBVS is also connected, via normally closed motor-operated butterfly valves, to the corresponding exhaust duct for the Fuel Handling Building Ventilation System (FHBVS). Upon receipt of a high radiation signal from the spent fuel storage pool area, the normally operating FHBVS will automatically de-energize and appropriate isolation dampers will close, the FHBVS-to-SBVS cross-tie valves will open, and the SBVS will automatically actuate to evacuate and filter air from the spent fuel storage pool area. The SBVS thereby provides the fission product removal function that is assumed for the postulated fuel handling accident.
To limit offsite radiation exposures that could result from either a LOCA or a fuel handling accident, assuming single active failure criteria, Limiting Condition for Operation (LCO) 3.6.6.1 requires two independent SBVS to be OPERABLE during "MODES 1, 2, 3, 4, 5, and 6 with operations involving movement of irradiated fuel
P
'I
~ 1
~ ~
~ ~
St. Lucie Unit 2 L-95-215 Docket No. 50-389 Attachment 1 Proposed License Amendment Page 2 of 5 Shield Buildin Ventilation S stem within the spent fuel storage pool or crane operations with loads over the spent fuel storage pool with irradiated fuel in the spent fuel storage pool." The LCO provides an ACTION statement for the case of a single inoperable SBVS in MODES 1, 2, 3, and 4, and another ACTION statement for a single inoperable SBVS in MODES 5 and 6.
Descri tion and Anal sls of Pro ose Chan es Marked-up copies of the applicable TS pages are contained in Attachment 3 to this submittal.
TS 3.6.6.1 Shi I Buildin Ven il i n m:
TA *I I g I gt << I ~PPLI APILITP I <<I statements to explicitly reflect the separate, but overlapping plant conditions gf that require an OPERABLE SBVS:
"At all times during MODES 1, 2, 3, and 4.
During movement ofirradiated fuel assemblies or during crane operations with loads over irradiated fuel assemblies in the Spent Fuel Storage Pool in MODES 1, 2, 3, 4, 5, and 6. "
Basis: The existing statement of applicability is a single run-on sentence that creates ambiguity, and could result in misinterpretation of the plant conditions that require the availability of an OPERABLE SBVS. The proposed change clearly relates that LCO 3,6.6.1 is applicable at all times during operational MODES 1, 2, 3, and 4, and thereby assures that SBVS operability assumptions used in the safety analyses to determine the site boundary radiation doses in the event of a LOCA remain valid. The second statement of applicability clearly relates that conditions in the Fuel Handling Building that would make a fuel handling accident a credible event are not mode-specific, and that LCO 3.6.6.1 is applicable whenever those conditions exist. Therefore, the proposed change also provides assurance that SBVS operability assumptions used in the fuel handling accident analysis to determine the radioactive effluent release to the environment remain valid.
The proposed change to LCO 3.6.6.1 APPLICABILITY, accounting for plant
'pecific differences, is consistent with NUREG-1432, LCO 3.6.13, "Shield Building Exhaust Cleanup System (SBEACS)(Dual)" and LCO 3.7.14, "Fuel Building Air Cleanup System (FBACS)."
'f a1
,<<g
St. Lucie Unit 2 L-95-215 Docket No. 50-389 Attachment 1 Proposed License Amendment Page 3 of 5 Shield Buildin Ventilation S stem
- 2. The existing ACTION statements for an inoperable SBVS will be deleted and replaced with the following:
"A~T~I)N: a. With the SBVS inoperable Zggdg due to loss of the SBVS capability to provide design basis j7ltered air evacuation from the Spent Fuel Pool area, only ACTION-c is required.
If the SBVS is inoperable for any other reason, concurrently implement ACTION-b and ACTION-c.
- b. (I) With one SBVS inoperable in MODE 1, 2, 3, or 4, restore the inoperable system to OPERABLE status within 7 days; otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
(2) With both SBVS inoperable in MODE 1, 2, 3, or 4, immediately enter LCO 3.0.3. "
C. (1) With one SBVS inoperable in any MODE, restore the inoperable system to OPERABLE status within 7 days; otherwise, suspend movement of irradiated fuel assemblies within the Spent Fuel Storage Pool and crane operations with loads. over irradiated fuel in the Spent Fuel Storage Pool.
(2) With both SBVS inoperable in any MODE, immediately suspend movement ofirradiated fuel assemblies within the Spent Fuel Storage Pool and crane operations with loads over irradiated fuel in the Spent Fuel Storage Pool.
~BI: The SBVS has two separate and distinct nuclear safety functions:
(1) to mitigate the effects of a LOCA by exhausting filtered air from the Shield Building, and (2) to mitigate the effects of a fuel handling accident by exhausting filtered air from the Fuel Handling Building. OPERABILITY is demonstrated, in part, by surveillances that require the SBVS to develop a specified "negative pressure" in the area to be exhausted.
St. Lucie Unit 2 L-95-215 Docket'No. 50-389 Attachment 1 Proposed License Amendment Page 4 of 5 Shield Buildin Ventilation S stem The existing ACTIONs provided by LCO 3.6.6.1 are stated for the condition where one SBVS (train) is inoperable in either "MODES 1, 2, 3, and 4," or "MODES 5 and 6." The former ACTION requires a unit transition to COLD SHUTDOWN if the inoperable SBVS train is not restored to OPERABLE status within 7 days. This action is appropriate for a condition where the SBVS is unable to perform its design safety function for mitigating the effects of a LOCA. However, the specified action provides no compensatory measures for the probable concurrent condition where the SBVS can not perform its design safety function for mitigating a fuel handling accident. Moreover, should a condition develop in the Fuel Handling Building during MODES 1, 2, 3, or 4 that impacts ~onl the SBVS capability to mitigate a fuel handling accident, such as opening the spent fuel cask shield door, the specified ACTION could result in an unwarranted unit shutdown and cooldown in addition to not requiring the proper compensatory measures until entering MODE 5.
The proposed ~ACTION- distinguishes between the compensatory actions required for the condition where only the SBVS capability to perform the fuel handling accident safety function is affected, and the case where both the fuel handling accident and the LOCA safety functions are affected. Considering the narrative format and existing structure of the PSL2 Technical Specifications, this Action statement is necessary to provide clear direction to facility operators that concurrent entry into the two independently stated reference Actions (b and c) within this same LCO is permissible, and depending upon the scope of SBVS inoperability, may or may not be required.
The proposed ACTION-b does not change the previously approved compensatory measures or the action completion times stated for "MODES 1, 2, 3, and 4" in the existing PSL2 Specification, and assures availability of the LOCA mitigation safety function consistent with the plant safety analyses.
This Action is also consistent with NUREG-1432, LCO 3.6.13, "Shield Building Exhaust Cleanup System (SBEACS)(Dual)"
The proposed ~ACTI N- is consistent with the previously approved compensatory measures stated for "MODES 5 and 6" in the existing PSL2 Specification, but clarifies that the compensatory measures are mode independent. The Action completion times are compatible with those stated in Action-b, and assure availability of the fuel handling accident safety function consistent with the plant safety analyses. Action-c, is also consistent with NUREG-1432, LCO 3.7.14, "Fuel Building Air Cleanup System (FBACS)."
St. Lucie Unit 2 L 95-2 l5 Docket'No. 50-389 Attachment 1 Proposed License Amendment Page 5 of 5 Shield Buildin Ventilation S stem Conclusion The proposed changes are consistent with the format and content of the current PSL2 Technical Specifications as well as the technical substance of the corresponding Specifications in NUREG-1432. By distinguishing between the conditions where (1) the cause of SBVS inoperability impacts the ability to provide both the LOCA and fuel handling accident mitigation safety functions, and (2) the cause of inoperability impacts ~nl the fuel handling accident mitigation safety function, the proposed actions provide assurance that the proper compensatory measures will be taken in the event one or both SBVS trains become inoperable. The changes more clearly identify the conditions for LCO Applicability and implementation of the stated Actions, and do not prescribe operability requirements different from the existing TS 3.6.6.1.
Therefore, FPL considers the proposed amendment to be administrative in nature.
~ ~
~ ~
St. Lucie Unit 2 Docket'No. 50-389 Proposed License Amendment Shield Buildin Ventilation S stem ATTACHMENT 2 DETERMINATION OF NO SIGNIFICANT HAZARDS CONSIDERATION
St. Lucie Unit 2 L-95-215 Docket'No. 50-389 Attachment 2 Proposed License Amendment Page 1 of 2 Shield Buildin Ventilation S stem DETERMINATION OF NO SIGNIFICANT HAZARDS CONSIDERATION Pursuant to 10CFR50.92, a determination may be made that a proposed license amendment involves no significant hazards consideration if operation of the facility in accordance with the proposed amendment would not: (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety. Each standard is discussed as follows:
(1) Operation of the facility in accordance with the proposed amendment would not involve a significant increase in the probability or consequences of an accident previously evaluated.
The proposed license amendment for St. Lucie Unit 2 will clarify the Applicability and the Actions required by Technical Specification (TS) 3.6.6.1, and explicitly account for the dual purpose of the Shield Building Ventilation System (SBVS) to perform design functions for both the Shield Building (secondary containment) and the Fuel Handling Building. The proposed amendment is administrative in nature.
The SBVS only operates when actuated by automatic control signals generated by systems detecting postulated accident conditions. The SBVS is not an accident initiator, the proposed TS changes do not involve any assumptions relative to accident initiators used in the plant safety analyses, and the amendment, therefore, will not impact the probability of occurrence for accidents previously analyzed. Relative to accident consequences, at least one train of the SBVS must operate to fulfill the design function of evacuating filtered air from the Shield Building during the postulated Loss of Coolant Accident; and likewise assumed in the analysis for the Fuel Handling Building during a fuel handling accident. The proposed changes simply remove elements of ambiguity from TS 3.6.6.1; do not reduce the existing operability requirements for the system; and provide further assurance that proper compensatory measures will be taken in the event one or both SBVS trains become inoperable.
Therefore, operation of the facility in accordance with the proposed amendment will not involve a significant increase in the probability or consequences of an accident previously evaluated.
St. Lucie Unit 2 L-95-215 Docket No. 50-389 Attachment 2 Proposed License Amendment Page 2 of 2 Shield Buildin Ventilation S stem (2) Operation of the facility in accordance with the proposed amendment would not create the possibility of a new or different kind of accident from any accident previously evaluated.
The proposed amendment is administrative in nature and will not change the physical plant or the modes of plant operation defined in the facility license. The changes do not involve the addition or modification of equipment, nor do they alter the design or methods of operation of plant systems. Plant configurations that are prohibited by TS will not be created by this amendment, Therefore, operation of the facility in accordance with the proposed amendment would not create the possibility of a new .
or different kind of accident from any accident previously evaluated.
(3) Operation of the facility in accordance with the proposed amendment would not involve a significant reduction in a margin of safety.
The proposed amendment will not change the SBVS operability requirements nor otherwise alter the basis for any technical specification that is related to the establishment of, or the maintenance of, a nuclear safety margin. The proposed changes are administrative in nature, and are designed to provide assurance that the SBVS capability to perform design functions assumed available in the safety analyses will remain available during the various plant operating modes. Therefore, operation of the facility in accordance with the proposed amendment would not involve a significant reduction in a margin of safety.
Based on the discussion presented above and on the supporting Evaluation of Proposed TS Changes, FPL has concluded that this proposed license amendment involves no significant hazards consideration.
St.,Lucie Unit 2 Docket No. 50-389 Proposed License Amendment Shield Buildin Ventilation S stem ATTACHMENT 3 ST. LUCIE UNIT 2 MARKED-UP TECHNICAL SPECIFICATION PAGES Page 3/4 6-27 Insert A