Attachment 1
St.
Lucz.e Units 1 Marked-Up Technical Specification Pages Pages 3/4-22 3/4-24 B 3/4 4-12 9'112270257 9112i7 PDR ADOCK 05000335 PD1%
REACTOR COOLANT SYSTEM SURVEILLANCE RE UIREMENTS 4.4.9.1 a.
The Reactor Coolant System temperature and pressure shall be determined to be within the limits at least once per 30 minutes during system heatup,
- cooldown, and inservice leak and hydrostatic testing operations.
b.
The Reactor Coolant System temperature and pressure conditions shall be determined to be to the right of the criticality limit line within 15 minutes prior to achieving reactor criticality.
c.
The reactor vessel material irradiation surveillance specimens shall be removed and examined, to determine chan s in material I I II' results of these examinations shall be use o up ate res 3.4-a, 3.4-2b and 3.4-3.
DEL~~ a~a a.~P~~
V3AQ 95 PE.Qu>mO SY
)C CFa.5u
~
APP~~Gi~ H.
ST.
LUCIE - UNIT 1 3/4 4-22 Amendment No. 81
O TABLE 4.4-5 Specimen cation
~
o Ve se VESSEL HATERIAL IRRADIATION SURVEILLANCE SCHEDULE Approximate Removal>>
Predicted Fluence Schedule EFPY ~
n cm'7
~ (1) 104 284'63'77'3
- 1. 54 2
1.02 1.54 1.54
.67 10 18 21 3 2 Standb~
5.5 x
10'.78 x 10 1.58 x 10"'"
2.78 x 10" 4.24 x 10
- 1) Info ation for this capsule is actual 2)
R lo of capsule fluence divided by the fluence at the controlling veld 3
pproxiaate end of life 1/4T fluence
'I
~
~
~
~
~ 4
REACTOR COOLANT SYSTEM BASES for piping, pumps and valves.
Below this temperature, the system pressure must be limited to a maximum of 20% of the system's hydrostatic test DELVE pressure of 3125 psia.
The limfations imposed on the pressurizer heatup and cooldown rates and spray water temperature differential are provided to assure that the pressurizer is operated within the design criteria assumed for the fati-gue analysis performed in accordance with the ASME Code requirements.
3/4.4.10 STRUCTURAL INTEGRITY The inservice inspection program for ASME Code Class 1,
2 and 3
components ensure that the structural fntegr fty of these components'ill be maintained at an acceptable level throughout the life of the plant.
This program fs fn accordance with Section XI oi'he ASME Boiler and Pressure Vessel Code and applicable Addenda as required by 10 CFR Part 50.55a(g) except where specific written relief has been granted by the Commission pursuant to 10 CFR Part 50.55a(g)(6)(f).
Components of the reactor coolant system were designed to provide access to permft inservfce inspections in accordance with Section XI of the ASME Boiler and Pressure Vessel Code 1971 Edition and Addenda through Wfnter 1972.
ST.
LUGIE - UNIT 1
B 3(4 4~12 Amendment No.
90
Attachment 2
St. Lucie Unit 2 Marked-Up Technical 8pecification Pages Pages XXIV 3/4 4-30 3/4 4-33 B 3/4 4-11
~
~
~ ~
L:ST OF TAc L=
(Con-.i nued)
)NOEÃ i'8L.
3.3-9 4.3>>6 3.3-10 REMOTE SHUTDOWN SYSTEM iNSTRUMEHTATION..
REMOTE SHUTDOWN SYSTEM It(STRUMEtlTATiOH SURVEILLANCE REqUIREMEilTS.........,.............
ACC v DE)'lT MONITORING INSTRUMENTATION
- PAGc, 3/4 3-39 3/4 3-40 3/< 3-42 4.3-i
- 3. 3-11 3.3-12 4.3-8
- 3. 3-13 4, 3-9 ACCIDENT MONITORIHG INSTRUMEHTATIOt< SURVEiL)LANCE REQUIREMENTS....,.....................
3/< 3-43
/
FIRE DET)EC> ION INSTRUMENTS......................
3/4 3-45 RAOIOAC; IVE LigLID EFFLUENT MONITORING itlST)?UMENTATIOH.... 3/< 3-49 RADI'OACTIVE LIQUID EFFLUEHT MONITORING INSTRUMENTATION SURVEIL&tlCE REQUIREMENTS.
~,
~ 3/< 3>>51 RADIOACTIVE GASEOUS EFFLUEHT MONITORING ItlSTRUMENTATION... 3/4 3-54 RAD.IOACTIVE GAScOUS EFFLUEHT MONITORING ii'lSTRUMEHTATIOH SURVEILLANCE REqUIREMEHTS 3/4 3-Si
- 4. 4-1 4.4-2 3.4-1 3
4,1 3
MINiMUM tlUMBER OF STEAM GEHERA70RS 70 BE INSPEC "D
DURING IHSERVICE Ii'lSP~CTION.
STc.4'E)'l~RATOR TUBE IHSPECTiON....,...................
- REACTOP, COOLANT SYSTEM PRESSURE ISOLATiON VALVES RD~CTOR COOLANT SYSTEM CHEMISTRY.
R ACTOR COOLANT SYS) cM CHEMISTRY L MITS SURVE ILLnllC REQUIRE)MENTS
~
~
3/< "-16 3/< 4-17 3/d.
4-21) 3/-'-43 PRIMARY COOLANT PROGRAM...
SP CIFiC AC: IVITY SAMP ANO nslAL.
iS p
~
</
- 3. 5-1 COHTAIHMEHT L="4K"GE. PATHS.
CON)'IHMEHT !SOL.'7'.Cll VALV-"
/
1
'I
~
~
~
~
~
~
~
~
~
~
~
~
~ vl v
v
\\
\\
v S I
~
LUCI>> UNI 2
-'.-endmen".
No. B '
REACTOR COOLANT SYSTEM SURVEILLANCE RE UIREMENTS (Continued) 4.4. 9. l. 2 The reactor vessel material irradiation surveillance specimens shall be removed and examined to determine chan es in material ro erties e results of these examinations s
a e
u e figures 3.4-2, 3.4-3 and 3.4-4.
M~E. n~o amp'.
4Q ~Tp Egu<~~ ~~i
~OCHER, 5o APPED@))~ H.
ST.
LUCIE - UNIT 2 3/4 4-30 Amendment No. f8, 3l
~
~
C
~
C:
m TABLE 4.4-5 REACTOR VESSEL HATERIAL SURVEILLANCE PROGRAH - WITHDRAWAL SCHEDULE C:
CAPSULE RNFR 1
2 3
5 6
VESSEL LOCATION 83 97 104 3cR 2770 284 LEAD FACTOR (1
<<1.5 (1.5
<I.5
<1 ~ 5
<1.5 WITHDRAWAL TINE EFPY 1.0 24 ~ 0 STANDBY
- 12. 0 STANDBY ANDBY DI
~
~
~
~
~
~
REACTOR COOLANT SYSTEM BASES The actual shift in RT T of the vessel material will be established periodical during ope atiI by removing and evaluating, in accordance with ASTM E185 and 10 CF ppendix H, reactor vessel material it radiation surveil-ance specimens installed near the inside wall of the reactor vessel in the
~
f core cree. ~~ve Since the nleu ron spectra a
e rr a a
on samp es an vesse ns e ra ius a
e essentially identical, the measured transition shift for a sample can be applied with confidence to the adjacent section of the reactor vessel.
The heatup and cooldown curves must be recalculated when the delta RT determined from the surveillance capsule is different from the calculated IINta RT for e uivalent ca sule radiation ex osure.
The pressure-temperature limit lines shown on Figures 3.4-2, 3.4-3 and 3.4-4 for reactor criticality and for inservice leak and hydrostatic testing have been provided to assure compliance with the minimum temperature requirements of Appendix G to 10 CFR 50.
The maximum RT>> for all Reactor Coolant System pressure-retaining materials, with the 5xception of the reactor pressure
- vessel, has been determined to be 60'F.
The Lowest Service Temperature limit line shown on Figures 3.4-2, 3.4-3 and 3.4-4 is based upon this RT since Article NB-2332 (Sumser Addenda of 1972) of Section III of the ASIDE Ilier and Pressure Vessel Code requires the Lowest Service Temperature to be RT D
+ 100'F for piping,
- pumps, and valves.
Below this temperature, the systeN jfressure must be limited to a maximum of 20% of the system's hydrostatic test pressure of 3125 psfa.
The limitations imposed on the pressurizer heatup and cooldown rates and spray water temperature differential are provided to assure that the pressurizer is operated within the design criteria assumed for the fatigue analysis performed in accordance with the ASME Code requirements.
The OPERABILITY of two PORVs, two SDCRVs or an RCS vent opening of greater than 3.58 square inches ensures that the RCS will be protected from pressure transients which could exceed the limits of Appendix 0 to 10 CFR Part 50 when one or more of the RCS cold leg temperatures aro less than or equal to the LTOP temperatures'.
The Low Temperature Overpressure Protection System has adequate relieving capability.to protect the RCS from overpressurizhtion when the transient
$s limited to either (1) a safety in)ection actuation in a water-solid RCS with 'the pressurizer heaters energized or (2) the start of an idle RCP wtth'he secondary water. temperature of the. steam generator less than or equal to 40'F above the RCS cold leg temperatures with the pressurtzer water-solid.
ST. LUCIE - UNIT 2 B 3/4 4-11 Amendment No. Jl, 3V.46,
J ~
~
~
~
~
Attachment 3
Safet Anal sis Introduction This change is proposed to revise the St.
Lucie Units 1
and 2
Technical Specifications to remove Table 4.4-5, Reactor Vessel Material Surveillance Program Withdrawal
- Schedule, and any references to the table from the Technical Specifications.
The appropriate reactor vessel material withdrawal schedules have already been incorporated in Table 5.4-3 of the Unit 1 FUSAR and Table 5.3-9 of the Unit 2 FUSAR.
Discussion In accordance with Generic Letter 91-01, the proposed change to the St.
Lucie Units 1
and 2
Technical Specifications revises the Reactor Coolant System Section 3/4.4.9, Pressure/Temperature Limits, by removing Table 4.4-5 and any references to the table from the Technical Specifications.
Appendix H Section II.B.'3 of 10 CFR Part 50,
- states, that:.
"A proposed withdrawal schedule must be submitted with a technical justification as specified in 10 CFR 50.4.
The proposed schedule must be approved prior to implementation."
Having this schedule in the Technical Specifications duplicates the control on changes to this schedule that has been previously established in 10 CFR 50 Appendix H.
The limiting conditions for operation (LCO) for the Reactor Coolant System include operating limits on pressure and temperature that are defined in Figures 3.4-2a, 3.4-2b and 3.4-3 of the St. Lucie Unit 1 Technical Specifications and Figures 3.4-2, 3.4-3, 3.4-4 of the St.
Lucie Unit 2 Technical Specifications.
They provide an acceptable region for operation during
- heatup, cooldown, criticality, and inservice leak and hydrostatic testing.
The surveillance requirement associated with this LCO addresses the frequency of verifying that,operation is within the specified limits during these operating conditions.
Also included is an additional surveillance requirement that states(
The reactor vessel material irradiation surveillance specimens shall be removed and examined, to determine changes in material properties, at the intervals required by 10 CFR 50 Appendix H in accordance with the schedule in Table 4.4-5.
The results of these examinations shall be used to update Figures 3.4-2a, 3.4-2b and 3.4-3-for the St. Lucie Unit 1 Technical Specifications and Figures 3.4-2, 3.4-3, and 3.4-4 for the St. Lucie Unit 2 Technical Specifications."
The proposed change would remove Table 4.4-5, and any references to the table from the Technical Specifications.
Because the surveillance
l'
requirement specifies that the results of these examinations shall be used to update Figures 3.4-2a, 3.4-2b and 3.4-3 for St. Lucie Unit 1 and 3.4-2, 3.4-3 and 3.4-4 for St.
Lucie Unit 2 for the pressure and temperature limits this requirement will be retained.
St.
Lucie Units 1
and 2 Technical Specification Bases Section 3/4.4.9, Pressure/Temperature Limits, gives a detailed description of the bases for this LCO and the related surveillance requirements.
The Standard Technical Specification (STS) bases references Table 4.4-5 which provides the schedule for surveillance specimen withdrawal.
This Bases Section provides considerable background information on the use of.the data gathered from material specimens.
This background information clearly defines the objective of this data as it relates to 10 CFR 50 Appendix H
and the American Society of Mechanical Engineers (ASME)
Code.
Deletion of the reference to Table 4.4-5 does not affect the content of this section.
Conclusion The reactor vessel material withdrawal schedules have already been incorporated into the Unit 1 and 2 FUSAR.
Removing them from the Unit 1 and 2 Technical Specifications will not result in any loss of clarity or control over the regulatory requirements of 10 CFR 50 Appendix H.
J
Attachment 4
Determination of No Si nificant Hazards Consideration The standards used to arrive at a determination that a request for amendment involves no significant hazards consideration are included in the Commissions regulation, 10 CFR 50.92, which state that no significant hazards considerations are involved if the operation of the facility in accordance with the proposed amendment would not (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a
new or different kind of accident from any accident previously evaluated; or (3) involve a
significant reduction in a margin of safety.
Each standard is discussed as follows:
(1)
Operation of the facility in accordance with the proposed amendment would not involve a significant increase in the probability or consequences of an accident previously evaluated.
The proposed amendment change does not involve a significant increase in the probability or consequences of an accident previously evaluated because the regulatory requirement of 10 CFR 50 Appendix H will remain in effect in the Technical Specifications.
Removing Table 4.4-5, and any references to it, will not result in any loss of regulatory control because changes to this schedule are controlled by the requirements of 10 CFR 50 Appendix H.
(2)
Use of the modified specification would not create the possibility of a new or different kind of accident from any accident previously evaluated.
The use of this modified specification cannot create the possibility of a new or different kind of accident from any previously evaluated because as previously stated in Appendix H Section II.B.3 of 10 CFR 50, the licensee must have a
withdrawal schedule approved by the NRC prior to implementation.
By removing Table 4.4-5, and any references to that
- table, FPL will only eliminate duplication of a
requirement that it already adheres to in 10 CFR 50 Appendix H.
(3)
Use of the modified specification would not involve significant reduction in a margin of safety.
By removing Table 4.4-5 the margin of safety would not be compromised because the surveillance requirement still requires surveillance specimens to be removed and examined, to determine changes in material properties, at intervals required by 10 CFR 50 Appendix H. In addition the results of
~"
these examinations shall be used to update the figures for the pressure and temperature operating limits required by the Technical Specifications.
Based on the above, we have determined that the proposed amendment does not (1) involve a significant increase, in the probability or consequences of an accident previously evaluated, (2) create the probability of a
new or different kind of accident from any accident previously evaluated, or (3) involve a
significant reduction in a margin of safety; and therefore does not involve a significant hazards consideration.
t J