NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NOS.

112 AND 53 TO FACILITY OPERATING LICENSE NOS.

DPR-67 AND NPF-16 FLORIDA POWER

& LIGHT COMPANY ET AL.

ST.

LUGIE PLANT UNIT NOS.

1

~ AND 2 DOCKET NOS. 50-335 AND 50-389

1.0 INTRODUCTION

By application dated February 26, 1991, Florida Power

& Light Company (FPL, the licensee) requested var ious changes to the Technical Specifications (TS) for the St. Lucie Plant, Unit Nos.

1 and 2.

The licensee proposed to make administrative changes to achieve consistency throughout the TS by removing outdated material, making minor text changes and correcting errors.

2.0 EVALUATION St. Lucie Unit 1 TS onl a)

On page 3/4 3-28, Table 3.3-7, the licensee proposed to add strong motion triaxial accelograph SHR-42-5.

This instrument was always part of the plant and is not the result of a plant change or modification.

Since this change corrects an erroneous

omission, the staff finds it acceptable.

b)

On page 3/4 3-42, Table 3.3-11, the licensee proposed to change the number of reactor coolant system (RCS) subcooling margin monitors from 1 to 2.

This change corrects an erroneous omission made when Amendment No. 79 revised Table 3.3-11.

With this correction, Table 3.3-11'will now accurately reflect the current instrumentation in the plant.

The staff finds this correction acceptable.

c)

On page 3/4 4-4, Surveillance Requirement 4.4.4, the licensee proposed to correct the reference by changing "4.8.1.1" to "4.8.1.1.2."

This is not a change but a correction to cite the proper surveillance requirement.

For that reason the staff finds this correction acceptable.

d)

The licensee proposed the following minor changes in text:

On pages 3/4 8-1 and 8-3, capitalize the word "OPERABILITY."

On page 3/4 8-2, capitalize the "s" in the word "Statement."

On page 3/4 8-6a, add the word "with" to the sentence.

On page 3/4 8-6b, correct spelling of "Specification" and "information."

The above changes correct gramIar, spelling and standardize capitalization in the TS.

Therefore, the staff finds the proposed changes acceptable.

9112110136 9 12 PDR ADDCK 05000335' PDR

(

~

e

~

I ~

I J

e (L

~

I

~

I e

I seliish s

~

e)

I I(I; I I I

~

~

I'1 1

(

e ~

I

~,(e

~

II e

~i I

~ ee I

~

I

~

I "J.I)

.I gJ~ e)i

~

I ~

I

~

~

1 l J (J se

) '.J I ~ I

~

~

~

'WL>>i s

e JJ

~

s I ()J e

~ ~ ( p

)T I

1

~

I I

I e

J

~

~ Le

~

i )

~,.

~ (

I 1

I I

J M I O'I

~

1J()J e

I'(4)

'I e

~

L f

~ s)v

~

~

~

'I I

~

~ I

~

(lI

~ (,

I

~ ~

t el

'd L,s)

I

~

etJ I ~

(

I (,I s

~

1

/ If I jp ~ I\\

~ ~ Lsf ('

I )

J I,

I l I ~ ~

~

)

I <<,I I I

~ V J

~ I)

~

~... i)

,JJ)(

I e

I

=

~

~ ii"se

~ e) s )) a

'i(I

,) Jvv

~

(

i:."

r

~

II I

~ IJi il

.'i )'

(

~

~

I J

..((e I

~ J

~

eeJQ Jsp

") sf 'f

(

~

I.I(

~

I f s

(

~

~

s e l h

~

J

, Js

.se '~ J.>>',1

'1 1 f.'

,J IS I II

~

J(( J 1J ce) s

)l.~ l

~

~ )I 1 l.

~

(~, ~,L

)

te J

I J s)J

~),

(

1

> I

)

1 I '

" (ss),.'

~ (

IJ.'s)ol

~. '1 e.

g

~ )

~ -".JJ

);

~ I IJ I

,(

I)'e e

J 1

~

)

)

~ (fl.>,)

I l

ski.I J IllI

~I s

)

~ ) I'L{ sJ I JJ I

)(ll

. f"(I J 3 i ':0!"

oil

~S.

es I

,ilJ J I

C.

...)'

) ( ':(I )I I (

JJ ll~ (.I I

a) v I 1': I ))l' f",a).'

Ls)s J ~l)4))Jf "e))

'./ "fIJ

)a)s) i '1' J

l )l

'e

).

L)

J I e i

L)

.I

'C I

ri>

)'( ia

))'s)

).()

I 1 (

~

I'r.Oils)J

. J

~ V I(

1

( ~ 1'...

IL,l(j )LJ J J J'l'TL")) 29'1

)

') ">")s

~

'1

) IJ

'-'L)1!

s i I >?

Ief 5 I

J 1

~ i J 1 yl(1,(.'

) 'l) 'lf ll(Jl'

)>f

.9) Js) J:)-)') )6 J we)

Jsl

~

I e>Sf(SJ 1

e)

On page 3/4 10-2, the licensee proposed to delete the reference to specification 3.1.3.2 from specifications 4.10.2.1 and 4.10.2.2.

The above deletion should have been made when Amendment No. 27, issued Nay 26, 1978, deleted'pecification 3.1.3.2.

Since the proposed, deletion corrects an error of omission, the staff finds the deletion acceptable.

St. Lucie Unit 2 TS onl a)

Over the years, a number of figures and tables in the TS have been changed by amendments without making corresponding changes on the appropriate pages of the TS index.

The licensee proposed to update the various index pages as follows:

1.

On page XXI, Figures 3.1-1, 4.2-1 and 3.4-2 are corrected in accordance with Amendment Nos. 40, 17 and 46, respectively.

2.

On page XXII, Figures 3.4-3, 3.4-4, and 8 3/4.4-1 are corrected in accordance with Amendment Nos. 46, 46 and 31, respectively.

Figure 5.6-1 is added in accordance with Amendment No. 7.

3.

On page XXIV, Table 4.4-5 is corrected in accordance with Amendment No. 31.

Tables 3.4-3 and 3.4-4 are added in accordance with Amendment No. 31.

4.

On page XXV, Tables 3.7-3a and 3.7-3b are deleted in accordance with Amendment No. 22.

The staff has reviewed all of the above proposals and finds that the index pages should be updated.

Therefore, the staff finds the proposed updates acceptable.

b)

On page 3/4 6-21, the licensee proposed to delete "HC" from valve identification on valves 2516 and 2522 to read I-V-2516 and I-V-2522.

This change corrects the TS to reflect the actual valve identification as it exists in the plant, and for that reason the staff finds the proposed changes acceptable.

c)

The licensee proposed to clarify and make the format of listing multiple valves consistent by the following changes:

1.

On page 3/4 8-18,

"-3645" with

"-3646" with

"-3647" with

"-3644" with replace:

N,25%35,45"

",26,36,46"

",27,37,47"

",24,34,44" 2.

On page 3/4 8-19, replace:

"TO 16" with ",10,11,12,13,14,15,16" "TO 19" with ",15,16,17,18,19"

0 l

Ot l

I, I

I C

~ I I

l t

I I

~

W<<\\

A

'E 1

~

J r

I r

~

~ I ') t V

~ ~ The staff has reviewed all of the above proposals and agrees that they are clarifying in nature.

For these

reasons, the staff finds them acceptable.

St. Lucie Units 1 and 2

a)

On pages 3/4 8-4, the licensee proposed to add "Local" to the diesel generator start option for the diesel generator surveillance requirements.

Amendments No.

103 for Unit 1, and No. 39 for Unit 2 allowed

. warmup and slow acceleration of the diesel generator for certain surveillance requirements.

In accordance with the guidance contained in CEN 152, "Emergency Procedure Guidelines,"

Revision 3, the term "manual" means to operate equipment from a location other than its physical location, normally from the control room.

The term "local" means to operate equipment at its physical location.

A warmup and slow acceleration of the diesel generator can only be accomplished by starting the diesel locally. It is, therefore, necessary to add the "Local" option to the TS to avoid confusing and inconsistent instructions for the operators.

The staff finds the proposed addition acceptable.

b)

On page 6-8 for Unit I and page 6-9 for Unit 2, in specification 6.5.1.7b, the licensee proposed to replace "a through e" with "a,b,d, and e."

In essence, this change deletes item "c" from specification 6.5.1.7b.

Item "c" reads:

"Review of all proposed changes to Appendix A Technical Specifications."

Specification 6.5.1.7 delineates the authority of the Facility Review

Group, and item b currently reads:

"Render determinations in writing with regard to whether or not each item considered under Specifications 6.5.1.6a through e.

above constitutes an unreviewed safety question."

The intent of. this specification is to determine whether the particular changes to the procedures,

tests, experiments etc., listed in specifications 6.5.1.6a through e need to be submitted to NRC for prior approval.

Since 10 CFR 50.59 already requires all changes to Appendix A

Technical Specifications be submitted to NRC for prior approval, item,"c" is not necessary.

Therefore, the staff finds this deletion acceptable.

3.0 STATE CONSULTATION

Based upon the written notice of the proposed amendments, the Florida State official had no comments.

4.0 ENVIRONMENTAL CONSIDERATION

These amendments change a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20.

The NRC staff has determined that the amendments involve no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in

~ 1 r

g

~

~

\\

4

~

a

)

I Y

~

4

~ y

~

p

~

.J

individual or cumulative occupational radiation exposure.

The Commission has previously issued a proposed finding that the amendments involve no significant hazards consideration and there has been no public comment on such finding (56 FR 15641).

Accordingly, these amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9).

These amendments also relate to changes in administrative procedures or requirements.

Accordingly, the amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(10).

Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of these amendments.

5.0 CONCLUSION

The Commission has concluded, based on the considerations discussed above, that:

(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed

manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendments will not be inimical to the common defense and security or to the health and safety of the public.

Principal Contributor:

Jan A. Norris Date:

December 5, 1991

i t

~ 1

~ L V

'V t

4

Docket Nos.

50-335 ynd 50-389 December 5,

1991 DISTRIBUTION See attached sheet Mr. J.

H. Goldberg President-Nuclear Division Florida Power and Light Company P.O.

Box 14000 Juno Beach, Florida 33408-0420

Dear Mr. Goldberg:

SUBJECT:

ST.

LUCIE UNITS 1 AND 2 -

ISSUANCE OF AMENDMENTS RE MAIN STEAM LINE AND MAIN FEEDWATER ISOLATION VALVES TAC NOS ~t74113 AND~174114 The Commission has issued the enclosed Amendment Nos.

111 and gp to Facility Operating License Nos.

DPR-67 and NPF-16 for the St.

Lucie Plant, Unit Nos.

1 and 2.

These amendments consist of changes to the Technical Specifications in response to your application dated July 26, 1989.

These amendments revise Technical Specifications Section 3.7 for both units to clarify testing requirements for the main steam line isolation valves and for the main feedwater line isolation valves.

A copy of the Safety Evaluation be included in the Commission's biweekly Federal

~Re ister notice.

Sincerely,

Enclosures:

1.

Amendment No.

<<1 to DPR-67 2.

Amendment No.

52 to NPF-16 3.

Safety Evaluation cc w/enclosures:

See next page

/s/

Jan A. Norris, Senior Project Manager Project Directorate II-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation OFC: LA NAME:D.

~ p

~

~

D I-rr s SPLB~: D: PD t

C. McCracken: H B

DATE:[(l(791:

i 4r'1:/('I/5I 91://r'jul 91: rr h.7 OFFICIAL RECORD COPY Document Name:

ST.

LUCIE AMEND 335/389 9112110316 911205 PDR ADOCK 05000335 PDR

}P, H

blr. J.

H. Goldberg

'lorida Power

& Light Company St. Lucie Plant CC:

Jack Shreve, Public Counsel Office of the Public Counsel c/o The Florida Legislature 111 West Hadison Avenue, Room 812 Tallahassee, Florida 32399-1400 Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission 7585 S.

Hwy A1A Jensen Beach, Florida 33457 Nr. Robert G. Nave, Director Emergency Management Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 Harold F. Reis, Esq.

Newman

& Holtzinger 1615 L Street, N.W.

Washington, DC 20036 John T. Butler, Esq.

Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Nr. James V. Chisholm, County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Nr. Charles B.

Br inkman, Manager Washington Nuclear Operations ABB Combustion Engineering, Nuclear Power 12300 Twinbrook Parkway, Suite 330 Rockvi1 le, Haryl and 20852 llr. Jacob Daniel Nash Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.

Ta 1 lahassee, Flori da 32399-0700 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 Hr.

R. E. Grazio Director, Nuclear Licensing Florida Power and Light Company P.O.

Box 14000 Juno Beach, Florida 33408-0420

sf

~

)

A

~

J M

I s

C r

~

DATED:

AMENDMENT NO.

111 TO FACILITY OPERATING LICENSE NO.

DPR ST.

LUCIE, UNIT 1 AMENDMENT NO.

52 TO FACILITY OPERATING LICENSE NO.

NPF ST.

LUCIE, UNIT 2

'ocket File NRC 8 Local PDRs PDII-2 Reading S.

Varga, 14/E/4 G.

Lainas, 14/H/3 H.

Berkow D. Miller J. Norris OGC-WF D.

Hagan, 3302 MNBB G.

Hil 1 (8), P-137 Wanda Jones, MNBB-7103 C. Grimes, ll/F/23 C.

McCracken ACRS (lo)

GPA/PA OC/LFMB PD Plant-specific file [Gray Fi lej M. Sinkule, R-II Others as required cc:

Plant Service list