TABLE 4.3-2 ENGINEERED SAFETY FEATURES ACTUATION SYSTEH IHSTRUHEHTAION SURVEILLANCE RE UIREHENTS FUNCTIONAL UNIT SAFETY INJECTION (SIAS) a.
tianual (Trip Buttons) b.
Containment Pressure - High c.
Pressurizer Pressure - Low d.
Automatic Actuation Logic CHANNEL CHECK N.A.
S S
N.A.
CHANNEL CALIBRATION N.A.
R R
N.A.
CHANNEL FUNCTIONAL TEST R
H V(1),
R (2)
NODES FOR WHICH SURVEILLANCE 1, 2, 3, 4
1, 2, 3
1, 2, 3
1, 2, 3, 4 2.
3.
CONTAINMENT SPRAY (CSAS) a.
Manual (Trip Buttons) b.
Containment Pressure High - High c.
Automatic Actuation Logic CONTAINMENT ISOLATION (CIAS) a.
Manual CIAS (Trip Buttons) b.
Safety Injection SIAS c.
Containment Pressure
- High
~ d.
Containment Radiation - High e.
Automatic Actuation Logic N.A.
S N.A.
N.A.
N.A.
S S
N.A.
N.A.
R H.A.
N.A.
N.A.
R R
N.A.
H H(1),
R (2)
R R
H
'(1),
R (2) 1, 2, 3, 4
1, 2, 3
1, 2, 3, 4 1, 2, 3, 4
1, 2, 3, 4
1, 2, 3
1, 2, 3
1,2,3,4 4.
HAIN STEAN LINE ISOLATION a.
t1anual (Trip Buttons)
N.A.
b.
Steam Generator Pressure - Low S
c.
Containment Pressure
- High S
d.
Automatic Actuation Logic N.A.
N.A.
R R
N.A.
R H
H H(1), R..(2) 1,2,3 1,2,3 1, 2, 3, 4
5.
CONTAINt1ENT SUMP RECIRCULATION (RAS) a.
manual RAS (Trip Buttons) b.
Refueling Water Storage Tank - Low c.
Automatic Actuation Logic N.A.
S N.A.
N.A.
R N.A.
H H(1),.R (2)
N.A.
1,2,3 1,2,3 840522 PDR AOOCK PDR 840@3 1 03 1 0~00038'
TABLE 4.3. -2 Continued ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE RE UIREMENTS FUNCTIONAL UNIT CHANNEL CHECK CHANNEL CALIBRATION CHANNEL FUNCTIONAL TEST MODES FOR MHICH SURVEILLANCE.
ttttt 6.
7.
LOSS OF POWER (LOV) a.
4.16 kV and 480 V Emergency Bus Undervoltage (Loss of Voltage) b.
- 4. 16 kV and 480 V Emergency Bus Undervoltage (Degraded Voltage)
AUXILIARYFEEDWATER (AFAS) a.
Manual (Trip Buttons) b.
SG Level and Pressure (A/B)-Low and hP (A/B) - High c.
SG Level (A/B) - Low and No Pressure Low Trip (A/B) d.
Automatic Actuation Logic N.A.
S N.A.
N.A.'
N.A.
M(1)
R (2) 1, 2, 3, 4 1, 2, 3, 4
1, 2, 3
1, 2, 3
10 2, 3
1, 2, 3
TABLE NOTATION (1)
Testing of Automatic Actuation Logic shall include energization/de-energization of each initiation relay (solid-state component) and verification of the OPERABILITY of each initiation relay (solid-state component).
'I (2)
A subgroup relay test shall be performed which shall include the energization/de-energization of each subgroup relay (solid-state component) and verification of the OPERABILITY of each subgroup relay (solid-state component).