Forwards IE Insp Rept 50-335/80-25 on 800624-0702 & Notice of Violation
ML17209A236
Person / Time
Site: Saint Lucie 
Issue date: 08/25/1980
From: Robert Lewis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
Shared Package
ML17209A234 List:
References
NUDOCS 8010150047
Download: ML17209A236 (2)


See also: IR 05000335/1980025

Text

~8 REGIj

(4

~o

Cy

  • 0

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100

ATLANTA,GEORGIA 30303

Xn Reply Refer To:

RII:PTB

50-335/80-25

AUG 8

5 1980

Florida Power and Light Company

ATTN:

R. E. Uhrig, Vice President

Advanced Systems

and Technology

P. 0. Box 529100

Miami, FL

33152

Gentlemen:

This refers

to the

inspection

conducted

by P. T. Burnett of this office on

June

24 to July 2,

1980,

of activities

authorized

by

NRC Operating

License

DPR-67 for the St. Iucie facility, and to the discussion

of our findings held

with C.

M. Wethy at the conclusion of the inspection.

Areas

examined

'during the inspection

and

our findings

are

discussed

in the

enclosed

inspection

report.

Within these

areas,

the inspection

consisted

of

selective

examinations of procedures

and representative

records,

interviews with

personnel,

and observations

by the inspector.

During the inspection, it was

found that certain activities under your license

appear

to be in noncompliance

with NRC requirements.

This item and references

to pertinent requirements

are listed in the Notice of Violation enclosed herewith

as Appendix A.

This notice is sent to you pursuant to the provisions of Section 2.201

of the NRC's "Rules of Practice," Part 2, Title 10,

Code of Federal Regulations.

Section 2.201

requires

you to submit to this office, within 20

days of your

receipt of this notice,

a written statement

or explanation in reply including:

(1) corrective steps

which have been taken by you and the results

achieved;

(2)

corrective steps

which will be taken to avoid further noncompliance;

and (3) the

date when full compliance will be achieved.

In accordance

with Section 2.790 of the

NRC's

"Rules of Practice,"

Part 2,

Title 10,

Code of Federal

Regulations,

a

copy of this letter and the enclosed

inspection report will be placed in the

NRC's Public Document

Room. If this

report

contains

any information that you (or your contractor)

believe to be

proprietary, it is necessary

that you make

a written application within 20 days

to this office to withhold such information from public disclosure.

Any such

application must include

a full statement

of the reasons

on the basis of which

it is claimed that the information is proprietary,

and should

be prepared

so

that proprietary information identified in the application is contained in

a

separate

part of the document. If we do not hear from you in this regard within

the specified period, the report willbe placed in the Public Document Room.

so xo xsoo9'7

'Florida Power and Light Company

AU62 61980

Should you have any questions

concerning this letter,

we will be glad to discuss

them with you.

Sincerely,

8. c.

R.

C.

ewis, Acting Chief

Reactor Operations

and Nuclear

Support. Branch

Enclosures:

l.

Appendix A, Notice of Violation

2.

Inspection Report Nos. 50-335/80-25

cc w/encl:

C.

M. Wethy, Plant Manager

Nat Weems, Assistant

QA Manager