ML17206A972

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-335/79-14 on 790605-08 & Notice of Violation
ML17206A972
Person / Time
Site: Saint Lucie 
Issue date: 06/20/1979
From: Robert Lewis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
Shared Package
ML17206A970 List:
References
NUDOCS 7908200015
Download: ML17206A972 (3)


See also: IR 05000335/1979014

Text

a>" R~cu

P0

Cy

~c

0

I

o

"w*<<+

In Reply Refer To:

RII:JAD

50-335/79-14

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100

ATLANTA,GEORGIA 30303

Jug

P. 0 1979

Florida Power and Light Company

R. E. Uhrig, Vice President

Advanced Systems

and Technology

P. 0. Box 529100

Miami, FL

33152

Gentlemen:

This refers to the inspection

conducted

by J. A. Dyer of this office on June 5-8,

1979,

of activities

authorized

by

NRC License

No.

DPR-67 for the St. Lucie

Unit 1 facility, and to the discussion of our findings held with C.

M. Wethy at

the conclusion of the inspection.

Areas

examined

during the inspection

and

our findings

are

discussed

in the

enclosed

inspection

report.

Within these

areas,

the inspection

consisted

of

selective

examinations of procedures

and representative

records,

interviews with

personnel,

and observations

by the inspector.

During the inspection, it was

found that certain activities under your license

appear

to be in noncompliance

with NRC requirements.

This item and references

to pertinent requirements

a'e listed in the Notice of Violation enclosed herewith

as Appendix A.

This notice is sent to you pursuant to the provisions of Section

2.201 of the NRC's "Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201

requires

you to submit to this office, within 20 days of your

receipt of this notice,

a written statement

or explanation in reply including:

(1) corrective steps

which have been taken by you and the results

achieved;

(2)

corrective steps

which will be taken to avoid further noncompliance;

and (3) the

date when full compliance will be achieved.

In accordance

with Section 2.790 of the NRC's "Rules of Practice," Part 2, Title

10, Code of Federal Regulations,

a copy of this letter and the enclosed inspection

report will be placed in the NRC's Public Document

Room. If this report contains

any information that you (or your contractor) believe to be proprietary, it is

necessary

that you make

a written application within 20 days to this office to

withhold such

information from public disclosure.

Any such application

must

include

a full statement of the reasons

on the basis of which it is claimed that

the information is proprietary,

and

should

be

prepared

so that proprietary

information identified in the application is contained in a separate

part of the

document. If we do not hear from you in this regard within the specified period,

the report willbe placed in the Public Document Room.

yi

Florida Power and Light Company

-2-

JUN

2 0 879

Should you have

any questions

concerning this letter,

we will be glad to discuss

them with you.

Sincerely,

8'.c

Richard

. Lewis, Acting Chief

Reactor Operations

and Nuclear

Support Branch

Enclosure:

Appendix A, Notice of Violation

Inspection Report No. 50-335/79-14

cc w/encl:

C.

M. Wethy, Plant Manager

P. 0. Box 128

Ft. Pierce,

FL

33450

Nat Weems, Assistant

gA Manager

P. 0. Box 128

Ft. Pierce,

FL

33450

L