Jump to navigation Jump to search
Responds to 780927 Ltr Re Violation Noted in Inspec Rept #50-335/78-19.Corrective Actions:Plastic Bags Containing Rad Matl Were Labeled Properly & All Req Documents Have Been Posted
ML17206A523
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 10/23/1978
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17206A522 List:
References
NUDOCS 7811240007
Download: ML17206A523 (5)


Text

FLORIDA POWER E LIGHT COMPANY October 23, 1978 L-78-336 Mr. James P. O'Rei lly, Director, Region II Office of Inspection and Enforcement U. S. Nuclear Regulatory Comission 101 Marietta Street, Suite 3100 Atlanta, Georgi a 30303

Dear Mr. O'Reilly:

Re: RI I: GRJ 50-335/78-19 Florida Power 5 Light Company has reviewed the 'subject inspection report nd a response is attached.

here is no proprietary information in the report.

Very truly yours, Robert E. Uhrig Vi ce Presi dent REU/WAK/cpc Attachment cc: Harold F. Reis, Esquire n q ~ ~ ~

h

~"  % ~ ~

ATTACEINEN T Re: RII:GRJ 50-335/78-19 Finding A 10 CFR 20.203(f) requires that each container of licensed material bear a durable, clearly visible label identifying the radioactive contents and providing sufficient information to permit individuals handling or using the containers, or working in the vicinity thereof, to take precautions to avoid or minimize exposures.

Contrary to the above, a large number of plastic bags containing radioactive material were observed on August 21, 1978, in an under-ramp storage area, without identifying labels.

ponse A The bags in question, which were all in the radiation controlled area, were properly labeled prior to the inspector's departure from the site. Appropriate personnel have been instructed to properly label such material in the future.

0

~ ~ w4 ndin B 10 CFR 19.11 requires, in part, that each licensee post carrent copies of 10 CFR 19, 10 CFR 20, the license and referenced documents, and operating practicable, procedures the licensee or, may if posting of a document is not post a notice which describes the document and states where notices are required to appear it may in be a

examined.

sufficient Posted documents and number of places to permit individuals engaged in licensed activities to observe them on the way to or from any particular licensed activity location to which the document applies.

Contrary to the above, the required documents or a notice were not posted in a place to permit individuals to observe them on the way to 'or from licensed activities in the reactor auxiliary building.

This was observed on August 24, 1978.

Response B In compliance with 10 CFR 19.11, all required material has been posted in the hallway of the Reactor Auxiliary Building. The klealth sics Supervisor will ensure that posting is continued as required the future.

~ ~ .