ML17191A798

From kanterella
Jump to navigation Jump to search

Informs That Licensee 980105,0522 & 0619 Responses to GL 97-04 Provided Info Requested,Therefore TACs M99985 & M99986 for Dresden,Units 2 & 3,closed
ML17191A798
Person / Time
Site: Dresden  
Issue date: 07/20/1998
From: Rossbach L
NRC (Affiliation Not Assigned)
To: Kingsley O
COMMONWEALTH EDISON CO.
References
TAC-M99985, TAC-M99986, NUDOCS 9807240113
Download: ML17191A798 (3)


Text

.. ~,

.,ar*

Mr. Oliver D. Kingsley, President Nuclear Generation Group Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 Jul.YJ20, 1998

SUBJECT:

COMPLETION OF LICENSING ACTION FOR GENERIC LETTER 97 DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3 (TAC NOS. M99985 AND M99986)

Dear Mr. Kingsley:

On October 7, 1997, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 97-04, "Assurance of Net Positive Suction Head for Emergency Core Cooling and Containment Heat Removal Pumps," to all holders of operating licenses or construction permits. The NRC issued GL 97-04 to confirm the adequacy of the net positive suction head (NPSH) available for emergency core cooling (including core spray and decay heat removal) and containment heat removal pumps under all design-basis accident scenarios.

In response to GL 97-04, Commonwealth Edison Company (ComEd) provided a letter dated January 5, 1998, for Dresden, Units 2 and 3. In response to a request for additional information dated May 22, 1998, ComEd submitted a letter on June 19, 1998. These submittals provided the information requested by GL 97-04. The staff has reviewed your response and has concluded that all requested information has been provided; therefore, we consider TAC Nos. M99985 and M99986 for Dresden, Units 2 and 3, closed.

If you have any questions regarding this matter, please contact me at (301) 415-2863.

Docket Nos. 50-237, 50-249 cc:

  • See next page DISTRIBUTION:

Docket File PUBLIC LRossbach CMoore

JKudrick, KKavanagh PD3-2 r/f ACRS LBurkhart Sincerely, ORIG. SIGNEE BY Lawrence W. Rossbach, Project Manager Project Directorate 111-2 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation EAdensam OGC DSkay SRichards MRing, Riii.

DOCUMENT NAME: G:\\CMNTSP\\DRESDEN\\DR99985.L TR OFFICE NAME DATE

(

9807240113 980720 PDR ADOCK 05000237 p

PDR

-T- - *-""""i:;ICIAL RECORD

~ -** '***-***~-*-.*

-~- ***-*h - ___ -.,._.,

UNITED STATES NUCLEAR REGULATORY COMMISSION Mr. Oliver D. Kingsley, President Nuclear Generation Group Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 WASHINGTON, D.C. 20555-0001 JJly 20, 1998

SUBJECT:

COMPLETION OF LICENSING ACTION FOR GENERIC LETTER 97 DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3 (TAC NOS. M99985 AND M99986)

Dear Mr. Kingsley:

On October 7, 1997, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 97-04, "Assurance of Net Positive Suction Head for Emergency Core Cooling and Containment Heat Removal Pumps," to all holders of operating licenses or construction permits. The NRC issued GL 97-04 to confirm the adequacy of the net positive suction head (NPSH) available for emergency core cooling (including core spray and decay heat removal) and containment heat removal pumps under all design-basis accident scenarios.

In response to GL 97-04, Commonwealth Edison Company (ComEd) provided a letter dated January 5, 1998, for Dresden, Units 2 and 3. In response to a request for additional information dated May 22, 1998, ComEd submitted a letter on June 19, 1998. These submittals provided the information requested by GL 97-04. The staff has reviewed your response and has concluded that all requested information has been provided; therefore, we consider TAC Nos. M99985 and M99986 for Dresden, Units 2 and 3, closed.

If you have any questions regarding this matter, please contact me at (301) 415-2863.

Docket Nos. 50-237, 50-249 cc: See next page Sincerely, oi---- ~, (!_J./'---

Lawrence W. Rossbach, Project Manager Project Directorate 111-2 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation

~--

-~--.-co*------***-***-*---~---~,--=o:-_--------~

0. Kingsley Commonwealth Edison Company cc:.

Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago; Illinois 60603 Commonwealth Edison Company Site Vice President - Dresden 6500 N. Dresden Road Morris, Illinois 60450-9765 Commonwealth Edison Company Dresden Station Manager 6500 N. Dresden Road Morris, Illinois 60450-9765 U.S. Nuclear Regulatory Commission Dresden Resident Inspectors Office 6500 N. Dresden Road Morris, Illinois 60450-9766 Regional Administrator U.S. NRC, Region Ill 801 Warrenville Road Lisle, Illinois 60532-4351 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety

  • 1035 Outer Park Drive Springfield, Illinois 62704 Chairman Grundy County Board Administration Building.

1320 Union Street Morris, Illinois 60450 Document Control Desk-Licensing Commonwealth Edison Company 1400 Opus Place, Suite 400 Downers Grove, Illinois 60515 Commonwealth Edison Company Reg. Assurance Supervisor - Dresden 6500 N. Dresden Road Morris, Illinois 60450-9765 Dresden Nuclear Power Station Units 2 and 3

  • Mr. David Helwig Senior Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515 Mr. Gene H. Stanley PWR's Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515 Mr. Steve Perry BWR's Vice President -

Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515 Mr. Dennis Farrar Regulatory Services Manager Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 Ms. Irene Johnson, Licensing Director Nuclear RegulatOry Services.

. Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515 Mr. Michael J. Wallace Senior Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, IL 60515