MONTHYEARML12278A3992012-08-31031 August 2012 WCAP-17077-NP, Rev 1, PWR Vessel Internals Program Plan for Aging Management of Reactor Internals at Robinson Nuclear Plant Project stage: Request RNP-RA/12-0100, Review Request for the PWR Vessel Internals Program Plan for Aging Management of Reactor Internals2012-09-26026 September 2012 Review Request for the PWR Vessel Internals Program Plan for Aging Management of Reactor Internals Project stage: Request ML12307A4082012-11-0202 November 2012 NRR E-mail Capture - Acceptance Review for the PWR Rector Vessel Internals Program Plan for Aging Management for H.B. Robinson Steam Electric Plant Unit No. 2 Project stage: Acceptance Review ML13079A2932013-03-27027 March 2013 Request for Additional Information Related to the Pressurized Water Reactors Internals Program Plan for Aging Management of Reactor Internals Project stage: RAI RNP-RA/13-0053, Response to NRC Request for Additional Information Related to Pressurized Water Reactors Internals Program Plan for Aging Management of Reactor Internals2013-05-23023 May 2013 Response to NRC Request for Additional Information Related to Pressurized Water Reactors Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI ML13135A1842013-05-29029 May 2013 Request for Additional Information Related to the Pressurized Water Reactors Internals Program Plan for Aging Management of Reactor Internals Project stage: RAI RNP-RA/13-0073, Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2013-07-25025 July 2013 Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI ML13240A4992013-08-27027 August 2013 NRR E-mail Capture - Robinson, Unit 2 PWR Vessel Internal Program Plan for Aging Management - Requests for Additional Information (Rais) Project stage: RAI ML13249A0002013-09-0505 September 2013 NRR E-mail Capture - Robinson, Unit 2 PWR Vessel Internal Program Plan for Aging Management - Requests for Additional Information (Rais) (TAC No. ME9633) - Correction to RAI-3-3 Project stage: RAI ML13266A2402013-09-23023 September 2013 NRR E-mail Capture - Robinson, Unit 2 PWR Vessel Internal Program Plan for Aging Management - Revised Requests for Additional Information (Rais) Project stage: RAI ML14016A2792014-01-0808 January 2014 NRR E-mail Capture - Robinson, Unit 2 PWR Vessel Internal Program Plan for Aging Management - Request for Additional Information (Rais) Project stage: RAI RNP-RA/13-0134, Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2014-01-0909 January 2014 Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI RNP-RA/14-0028, Response to NRC Request for Additional Information Re Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2014-02-19019 February 2014 Response to NRC Request for Additional Information Re Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI ML14115A4402014-04-24024 April 2014 NRR E-mail Capture - H. B. Robinson, Unit 2 PWR Vessel Internal Program Plan for Aging Management - Request for Additional Information (Rais) Project stage: RAI ML14167A3452014-06-16016 June 2014 NRR E-mail Capture - H. B. Robinson MRP-227-A RAI Status Project stage: RAI RNP-RA/14-0097, Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2014-09-0505 September 2014 Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI ML15009A2842015-01-22022 January 2015 Request for Withholding of Proprietary Information from Public Disclosure Project stage: Withholding Request Acceptance RNP-RA/16-0011, Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2016-02-18018 February 2016 Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI ML16063A1032016-02-18018 February 2016 Response to NRC Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI ML16280A2002016-10-0505 October 2016 Response to Request for Additional Information Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Response to RAI RNP-RA/17-0042, Submittal of the PWROG-14048-P, Revision 1, to Satisfy the Regulatory Commitment Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2017-06-29029 June 2017 Submittal of the PWROG-14048-P, Revision 1, to Satisfy the Regulatory Commitment Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals Project stage: Other 2013-09-05
[Table View] |
|
---|
Category:Letter type:RNP
MONTHYEARRNP-RA/21-0035, Duke Energy Progress, Inc - Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2021-02-18018 February 2021 Duke Energy Progress, Inc - Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report RNP-RA/20-0234, Independent Spent Fuel Storage Installation, Registration of Use of Spent Fuel Casks2020-07-23023 July 2020 Independent Spent Fuel Storage Installation, Registration of Use of Spent Fuel Casks RNP-RA/20-0199, Registration of Use of Spent Fuel Casks2020-06-25025 June 2020 Registration of Use of Spent Fuel Casks RNP-RA/18-0063, Request for Extension of Due Date for Seismic Probabilistic Risk Assessment Submittal2018-11-29029 November 2018 Request for Extension of Due Date for Seismic Probabilistic Risk Assessment Submittal RNP-RA/18-0060, Transmittal of Core Operating Limits Report2018-10-17017 October 2018 Transmittal of Core Operating Limits Report RNP-RA/18-0050, Response to Supplemental Request for Additional Information Regarding License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Change2018-08-0101 August 2018 Response to Supplemental Request for Additional Information Regarding License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Change RNP-RA/18-0044, Supplement to License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transform2018-07-11011 July 2018 Supplement to License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transformers RNP-RA/18-0039, Transmittal of Emergency Procedure Revisions and 10 CFR 50.54(q) Summary of Analysis2018-06-27027 June 2018 Transmittal of Emergency Procedure Revisions and 10 CFR 50.54(q) Summary of Analysis RNP-RA/18-0041, Independent Spent Fuel Storage Installation - Register as User for Cask2018-06-13013 June 2018 Independent Spent Fuel Storage Installation - Register as User for Cask RNP-RA/18-0036, Response to Request for Additional Information (RAI) Regarding Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use ...2018-05-16016 May 2018 Response to Request for Additional Information (RAI) Regarding Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specification 3.8.1, AC Sources - Operating and the Use ... RNP-RA/18-0029, Submittal of 2017 Annual Radiological Environmental Operating Report2018-05-0808 May 2018 Submittal of 2017 Annual Radiological Environmental Operating Report RNP-RA/18-0031, (Hbrsep), Unit 2 - 2017 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Revision 352018-04-23023 April 2018 (Hbrsep), Unit 2 - 2017 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Revision 35 RNP-RA/18-0015, Application for Technical Specifications Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequently Requirements to a Licensee Controlled Program2018-04-16016 April 2018 Application for Technical Specifications Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequently Requirements to a Licensee Controlled Program RNP-RA/18-0024, Report of Changes Pursuant to 10 CFR 50.59(d)(2)2018-04-0202 April 2018 Report of Changes Pursuant to 10 CFR 50.59(d)(2) RNP-RA/18-0020, Notification of Change in Licensed Operator Status2018-02-20020 February 2018 Notification of Change in Licensed Operator Status RNP-RA/18-0003, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2018-01-23023 January 2018 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report RNP-RA/17-0085, Request for Additional Information Regarding Application to Revise Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2018-01-0808 January 2018 Request for Additional Information Regarding Application to Revise Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0086, Transmittal of Emergency Procedure Revision and 10 CFR 50.54(q) Summary of Analyses2017-12-14014 December 2017 Transmittal of Emergency Procedure Revision and 10 CFR 50.54(q) Summary of Analyses RNP-RA/17-0081, Submittal of Change in Licensed Operators Medical Status2017-12-11011 December 2017 Submittal of Change in Licensed Operators Medical Status RNP-RA/17-0079, Operator License Renewal Application2017-12-0707 December 2017 Operator License Renewal Application RNP-RA/17-0071, Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License Spent Fuel Casks2017-10-19019 October 2017 Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License Spent Fuel Casks RNP-RA/17-0068, Response to NRC Request for Additional Information Related to License Amendment Request Regarding Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2017-09-28028 September 2017 Response to NRC Request for Additional Information Related to License Amendment Request Regarding Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0037, License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specifications 3.8.1, AC Sources-Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transformers2017-09-27027 September 2017 License Amendment Request Proposing to Add a Qualified Offsite Circuit to Technical Specifications 3.8.1, AC Sources-Operating and the Use of Load Tap Changers in the Automatic Mode of Operation on the Startup Transformers RNP-RA/17-0043, Relief Request (RR)-12 for Relief from Volumetric/Surface Examination Frequency Requirements of ASME Code Case N-729-42017-09-22022 September 2017 Relief Request (RR)-12 for Relief from Volumetric/Surface Examination Frequency Requirements of ASME Code Case N-729-4 RNP-RA/17-0065, Refueling Outage 30 Steam Generator Tube Inspection Report2017-09-18018 September 2017 Refueling Outage 30 Steam Generator Tube Inspection Report RNP-RA/17-0060, Notification of Change in Licensed Operator Status2017-08-10010 August 2017 Notification of Change in Licensed Operator Status RNP-RA/17-0058, Notification of Change in Licensed Operator Status2017-08-0303 August 2017 Notification of Change in Licensed Operator Status RNP-RA/17-0055, Transmittal of Core Operating Limits Report for Cycle 312017-07-26026 July 2017 Transmittal of Core Operating Limits Report for Cycle 31 RNP-RA/17-0042, Submittal of the PWROG-14048-P, Revision 1, to Satisfy the Regulatory Commitment Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals2017-06-29029 June 2017 Submittal of the PWROG-14048-P, Revision 1, to Satisfy the Regulatory Commitment Related to the Pressurized Water Reactor Internals Program Plan for Aging Management of Reactor Internals RNP-RA/17-0051, Submittal of Nine Day Inservice Inspection Summary Report2017-06-29029 June 2017 Submittal of Nine Day Inservice Inspection Summary Report RNP-RA/17-0041, Transmittal of Technical Specifications Bases Revisions2017-05-23023 May 2017 Transmittal of Technical Specifications Bases Revisions RNP-RA/17-0038, (Hbrsep), Unit No. 2 - 2016 Annual Radiological Environmental Operating Report2017-05-0909 May 2017 (Hbrsep), Unit No. 2 - 2016 Annual Radiological Environmental Operating Report RNP-RA/17-0034, Modification of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles (MF9544)2017-05-0202 May 2017 Modification of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles (MF9544) RNP-RA/17-0036, (Hbrsep), Unit No. 2 - 2016 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Current Revision 342017-04-25025 April 2017 (Hbrsep), Unit No. 2 - 2016 Annual Radioactive Effluent Release Report and Offsite Dose Calculation Manual, Current Revision 34 RNP-RA/17-0031, Provides Additional Information Regarding License Amendment Request to Adopt Technical Specifications Task Force (TSTF) Traveler 522, Revision 02017-04-20020 April 2017 Provides Additional Information Regarding License Amendment Request to Adopt Technical Specifications Task Force (TSTF) Traveler 522, Revision 0 RNP-RA/17-0033, Flood Hazard Mitigating Strategies Assessment (MSA) Report Submittal2017-04-12012 April 2017 Flood Hazard Mitigating Strategies Assessment (MSA) Report Submittal RNP-RA/17-0014, Resubmittal of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2017-04-0303 April 2017 Resubmittal of Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0028, Submittal of Engineering Calculation in Support of a Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2017-04-0303 April 2017 Submittal of Engineering Calculation in Support of a Request for Technical Specification Change to Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/17-0021, Transmittal of Core Operating Limits Report2017-03-13013 March 2017 Transmittal of Core Operating Limits Report RNP-RA/17-0019, Supplemental Submittal to Correct Marked Up Technical Specifications (TS) Pages Transmitted with Application for Technical Specification Task Force (TSTF)-339, Relocate TS Parameters to the COLR Consistent with WCAP-14483, Revision 22017-03-0808 March 2017 Supplemental Submittal to Correct Marked Up Technical Specifications (TS) Pages Transmitted with Application for Technical Specification Task Force (TSTF)-339, Relocate TS Parameters to the COLR Consistent with WCAP-14483, Revision 2 RNP-RA/17-0015, Independent Spent Fuel Storage Installations - Letter Regarding Report of Changes Pursuant to 10 CFR 72.482017-02-22022 February 2017 Independent Spent Fuel Storage Installations - Letter Regarding Report of Changes Pursuant to 10 CFR 72.48 RNP-RA/17-0016, Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report2017-02-22022 February 2017 Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report RNP-RA/17-0015, H.B. Robinson Steam Electric Plant & ISFSIs - Report of Changes Pursuant to 10 CFR 72.482017-02-22022 February 2017 H.B. Robinson Steam Electric Plant & ISFSIs - Report of Changes Pursuant to 10 CFR 72.48 RNP-RA/16-0100, Response to Apparent Violation in NRC Inspection Report 05000261/2016404, EA-16-2272017-01-24024 January 2017 Response to Apparent Violation in NRC Inspection Report 05000261/2016404, EA-16-227 RNP-RA/16-0097, Transmittal Letter for Response to Inspection Report Temporary Instruction 2201/004, Inspection of Implementation of Interim Cyber Security Milestones 1-7, Inspection Report 05000261/20154052016-12-15015 December 2016 Transmittal Letter for Response to Inspection Report Temporary Instruction 2201/004, Inspection of Implementation of Interim Cyber Security Milestones 1-7, Inspection Report 05000261/2015405 RNP-RA/16-0089, Request for Withdrawal of License Amendment Request for Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles2016-11-10010 November 2016 Request for Withdrawal of License Amendment Request for Change Technical Specification Surveillance Requirement Frequencies to Support 24-Month Fuel Cycles RNP-RA/16-0090, Notification of Rescheduled Date for 2017 Emergency Preparedness Graded Exercise2016-11-10010 November 2016 Notification of Rescheduled Date for 2017 Emergency Preparedness Graded Exercise RNP-RA/16-0087, Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors2016-10-31031 October 2016 Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors RNP-RA/16-0078, Technical Specifications Section 5.6.6, Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors2016-10-0505 October 2016 Technical Specifications Section 5.6.6, Post Accident Monitoring Instrumentation Report for Inoperable High Range Containment Area Radiation Monitors RNP-RA/16-0079, Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Standard 805, Performance-Based Standard for Light Water Reactor Electric Generating Plants.2016-10-0505 October 2016 Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Standard 805, Performance-Based Standard for Light Water Reactor Electric Generating Plants. 2021-02-18
[Table view] |
Text
Ernest J. Kapopoulos, Jr.
H. B. Robinson Steam Electric Plant Un# 2 Sffe Vice President Duke Energy 3581 West Entrance Road Hartsville, SC 29550 0 843 8571701 F: 843 8571319 Ernit.Kap11puu/os @dukt-tntrgy.c11m 10 CFR 54.21 Serial: RN P-RA/17-0042 JUN 2 9 2017 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261/RENEWED LICENSE NO. DPR-23 SUBMITIAL OF THE PWROG-14048-P, REVISION 1, TO SATISFY THE REGULATORY COMMITMENT RELATED TO THE PRESSURIZED WATER REACTOR INTERNALS PROGRAM PLAN FOR AGING MANAGEMENT OF REACTOR INTERNALS (TAC NO. ME9633)
References:
- 1. Pressurized Water Reactor Owners Group letter to NRC. "PWR Owners Group Submittal of PWROG-14048-P, Revision 1, "Functionality Analysis: Lower Support Columns," dated March 1, 2017 (ADAMS Accession No. ML17066A266)
Ladies and Gentlemen:
By letter dated February 08, 2016 (ADAMS Accession Number: ML16019A053), the NRC requested that Duke Energy, respond to a request for additional information (RAI) regarding the Aging Management Program for the Reactor Vessel Internals at H.B. Robinson Steam Electric Plant (HBRSEP), Unit No. 2.
The Duke Energy response to this request (RAl-5(b)-1-2) was provided in Enclosures 1 and 2 of the Duke Energy letter, dated February 18, 2016 (ADAMS Accession Number: ML16054A159).
In particular, Enclosure 2 of the Response to RAl-5(b)-1-2, contained a regulatory commitment for the Staff's consideration, related to the HBRSEP, Unit No. 2, Cast Austenitic Stainless Steel(CASS)
Lower Support Columns (LSC) in the Reactor Vessel.
By letter dated December 15, 2016, the NRC issued a Staff Assessment (ADAMS Accession Number: ML16281A510), which concluded the HBRSEP, Unit No. 2, Reactor Vessel Internals Aging Management Program Plan is acceptable because it is consistent with the inspection and evaluation guidelines of Materials Reliability Program Report (MRP)-227-A, "Pressurized Water Reactor Internals Inspection and Evaluation Guidelines" and it has adequately addressed all eight specified licensee action items.
United States Nuclear Regulatory Commission Serial: RNP-RA/17-0042 Page 2 of 3 In the Staff Assessment, the NRG concurred with the establishment of the above mentioned commitment and the Duke Energy's HBRSEP, Unit No. 2, approach to utilize the industry PWROG-14048-P report to provide justification of plant-specific applicability related to HBRSEP, Unit No. 2, specific parameters and operating conditions. The HBRSEP, Unit No. 2, made a commitment to submit a revised version of the PWROG-14048-P, Revision 0, report by June 30, 2017.
The technical report associated with tasks related to PWROG-14048-P, has been revised and submitted to the NRG via the PWR Owners Group, for information only, as detailed in Reference 1.
It is noted, HBRSEP, Unit No. 2, is identified as Plant Jin the stated analysis. This analysis concludes that there is reasonable assurance that the Lower Support Columns (LSCs) will remain functional through the period of extended operation, the LSCs show considerable tolerance to the existence of potential flaws, and that inspections are not necessary to ensure the functionality of the LSCs through the period of extended operation.
A copy of the regulatory commitment originally made in Response to RAl-S(b)-1-2, and explicitly referred to in the Staff Assessment, is reproduced in the Enclosure to this letter. The submittal of the PWROG-14048-P, Revision 1, hereby satisfies the regulatory commitment related to the Staff Assessment and the RAl-S(b)-1-2. There are no additional regulatory commitments made in this submittal. If you have any questions regarding this submittal, please contact Mr. Tony Pilo, Manager - Nuclear Regulatory Affairs, at (843) 857-1409.
I declare under penalty of perjury that the foregoing is true and correct.
Executed On: t,.q'fut-J~-iot7 Sincerely, Ernest J. Kapopoulos, Jr.
Site Vice President
United States Nuclear Regulatory Commission Serial: RNP-RA/17-0042 Page 3 of 3 EJK/am
Enclosure:
Regulatory Commitment (reproduced from RAl-S(b)-1-2) cc: NRC Regional Administrator, NRC, Region II D. Galvin, NRC Project Manager, NRR (w/o Enclosures)
NRC Resident Inspector, HBRSEP Unit No. 2
United States Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/17-0042 2 Pages (including cover page)
REGULATORY COMMITMENT (REPRODUCED FROM RAl-S(b)-1-2)
United States Nuclear Regulatory Commission Enclosure to Serial: RNP-RA/17-0042 REGULATORY COMMITMENT The following table identifies the action committed to by H. B. Robinson Steam Electric Plant (HBRSEP), Unit No. 2, in this submittal. All other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.
TYPE (Check One) SCHEDULED COMMITMENT ONE- COMPLETION CONTINUING DATE/EVENT TIME COMPLIANCE ACTION 1 Robinson will submit a copy of the x June 30, 2017 Technical Report associated with tasks related to PWROG PA-MSC-1103, Revision 2, to the NRC by Uune 30, 2017.
lrhe stated Technical Report will
~ontain RNP applicable flaw tolerance analysis developed based upon PWROG-14048-P, as reflected in RAl-S(b)-1-2, of the NRC Letter, dated February 08, 2016 (ADAMS Accession Number: ML16019A053}.
In particular, this Technical Report Will address Action Item 7 from the NRC final safety evaluation (SE)
(ADAMS Accession No. ML11308A770) of the Materials Reliability Program (MRP)-227-A report, "Pressurized Water Reactor Internals Inspection and Evaluation Guidelines" (ADAMS
~ccession No. ML120170453) in reference to the functionality of the Lower Support Columns.