OCT 2 '7 1992 MEMORANDUM FOR:

John A. Zwolinski, Assistant Director

  • for Region Ill Reactors Division of Reactor Projects - 111/IV/V Office of Nuclear Reactor Regulation FROM:

Hubert *J. Miller, Director

  • Division of Reactor Safety, Region III

SUBJECT:

REQUEST FOR TECHNICAL ASSISTANCE INTERPRETATION AND RESOLUTION OF REGULATORY GUIDE (RG) 1.97 INSPECTION FINDINGS (AITS # 92-0635 THROUGH 92-0641)

This memorandum transmits seven requests for NRR technical assistance, which are necessary to determine if the items identified in the attached enclosures comply with the appropriate revisi6ns to RG *1.97.

The table, Attachment' l, i~

a summary of the known remainfog items that require further review to complete our inspection of RG 1.97.

The ~nclosures and associated attathme~ts*provide specific information *about the conditions o~ licensee position ~nco~ntered during our inspections.

Based upon the gene~ic nature of the items, we have concluded that these items should be reviewed and resplved by NRR.

Alr of -the.*.--

items were discussed with NRR/SICB during the time of and subsequent to our inspections.. The items needing review fall into five areas:

1.

Review and acceptance of isolator type (e.g., use of resistors-as isolators, maximum credible fault isolator test report data),

2..

Review and.acceptance of alternate methods (not within the RG requirement) used for the unique identification of control room instrumentation,

3.

Resolution of the BWR neutr.on* flux monitoring issue,

. 4.

Redundancy of instrumentation, and

5.

Reclassification of a Category 1, Type A variable.*

We request that NRR review and determine the acceptability of licensee positions on the enclosed RG 1.97 compliance issues.

Please note that a number of these issues were identified in inspections many months ago, but we do not view them to be of immediate safety concern; therefore, at NRR request, they were held to the end of the inspection program in order to allow for consistent, generic treatment.

~

/fe,.pp,-~

7 b 921027 92110300 05000237 PDR ADOCK

-:-.*~--,..

-~~--

_*:*-~-:--_-: -=*--*-*

.. r; J. A. Zwolinski 2

OCT 2 7 1992.

Direct any questions concerning this subject to either George Hausman at (708) 790-5523 or Frank Jablonski at (708} 790-5555.

We corisider this to be a Priority 2 item with a completion date of January 16, 1993.

Attachment:

Region III RG 1.91 TIA Req~est

Enclosures:

1.

D~vis-Besse TIA Request

2.

Dresden TIA Request

3.

Fermi TIA Request

4.

LaSalle TIA Request

5.

Palisades TIA Request..

.

  • 6. *. Point Beach. TIA Request *
7.

Quad Cities TIA Request See Attached Distribution Riii Riii Riii

~.

Hausman *

. ~ ;1.f<#

Jab~onski LH'asse 10/if, /92 10/-z_t,J92 10/'Zh /92

..., '~I '* * * *' ~...

.,_;; :.~

  • I...:.~)

iJ i *.i ; ~* ~--...:.. \\ l

....... - (.., __. ~

Hubert J. Miller, Director Division of Reactor Safety.

Riii

,~*

Ring

  • 10~/92 :/(

{Jto/~92 Riii

J. A. Zwolinski cc w/Attachment only:

R. J. Barrett, NRR M. W. Hodges, RI A. F. Gibson, RII S. J. Collins, RIV K. E. Perkins, RV TSS/RI II cc w/Attachment and Enclosure as Listed:

J. B. Hopkins, NRR *{Enc. 1)

B. L. Siegel, NRR {Encs. 2 & 4)

T. G. Colburn, NRR {Enc. 3)

A. S. Masciantonio, NRR {Enc. 5)

R. B. Samworth, NRR {Enc. 6)

L. N. Olshan, NRR {Enc. 7)

A. G. Hansen, NRR {Encs.

1~7)

B. S. Marcus, NRR {Encs. 1-7)

S. F. Newberry, NRR {Encs. 1-7)

DCD/DCB {RIDS) {Encs. 1-7).

3 OCT 2 7 1992

ATTACHMENT Page 1 of 2

\\.

REGION I I I REGULATORY GUIDE 1.97 TIA REQUEST Inspection RG 1.97 Slits Plant Report lud>ers Inspection Dates lnspector(s)

Rev. lo.

Status

~resolved ltem(s)

Davis-346/88038(DRS) 12/12/88-2/1/89 M.

~:~:n, 3

Op*n.

'346/88038-02(DRSll:

Th* lfc*n***'* plant d*sfgn dfd not fnclud* r*dundant R*port fssu*d 2/14/89 A.

EG&.G nstrument chann* s from sensor to display for steam generator pressure.

Besse Bas*d upon dfscussfon wfth NRR/SICB durfng fnsp*ctfon 90021, thfs ft... r.mafns op*n p*ndfnJ NRR r*vf*w and acc*ptanc* of th* lfc*ns** submittal dat*d 3/19/90 346/90021(DRS) 10/15/90-11/5/90 M. Kopp (Enclosur*

).

R*port fssu*d 11/21/90 G. Hausman

~346/88038-04(DRSll:

Th* lfc*ns** us*d non-Class lE pr*ssur* swftch*s fn th*

ategory i, fyp*

{licensee designated) variable, control room normal v*ntf latfon status.

Bas*d upon dfscussfon wfth NRR/SICB durfng fns~*ctfon 90021, this ftem remains open pending NRR review and acceptance of fcen***

submittal dat*d 3/15/91 to downgrad* th* varfabl* to Cat*gory 2, Typ* D (Enclosur* 1).

'346/88038-08~DRS~l:

Th* lfc*ns** has a numb*r of RG 1.97 control room nstruments t atave not been fdentf ffed with a unique fdentf ffcatfon as r*qufr*d by RG 1.97.

Thfs ftem remains open pending NRR review and acceptance of th* lfcens**'* method of control room fnstrumentatfon fdentfffcatfon (Enc'l osur* 1 l.

1 Dresden 237/90016!DRSl 5/21/90-6/21/90 M. Kopp 2

Op*n (237/90016-03(DRSli249/90015-03~DRS)l: Thfs ftam ramafns op*n p*ndfn~ NRR 249/90015 DRS R*port fssu*d 7/13/90 G. Hausman review and resolu on of the BW neu ron flux monitoring instrumentat on issue (Enclosur* 2).

(237/90016-04(DRSl;249/90015-04(DRSl);

Thfs ft*m ramafns op*n pandfng NRR review ana acceo£ance of £ne Roore solator test reoort data (Enclosure 2).

Fermi-2 341/91014(DRS) 6/24/91~6/28/91 M. Kopp 2

Op*n (341/91014-01,DRSll:

Thfs ft*m r... afns op*n pendfng NRR r*vfaw and acc*ptanc*

R*port f11u*d 7/16/91 G. Hausman of no unique den fication of control room instruments, which was identified A. Holan, EG&.G in the licensee's submittal but n*fther approvad or dfsapprovad fn th* SER (Enclosur* 31.

LaSalle 373/88027!DRSl 10/17 - 24/88 A. Gautam 2

CloHd (3i3/88027-0l(DRSl*374/88026-0l(DRSll:

Thf s f tam r*maf ns opan p*ndf ng NRR 374/88026 DRS R*port fssu*d 12/5/88 M. Kopp rev1ew and re101ut1on of "t.n* DWK neutron flux monitoring instrumentation issue M. Trojovsky, EG&G (Enclosur* 4).

373/90022!DRSl 9/17-21/90 M. Kopp (373/88027-05(DRS);374/88026-05(DRSl):

Thfs ftem remafns open pandfn' NRR 374/90023 DRS Raport fssu.*d 10/11/90 G. Hausman review and acceptance of £ne Roches er isolator test report data (Enc osure 4).

(373/90022-0llDRS\\ *374/90023-0llDRSll:

Thfs ftem ramafns open pandfng NRR rev1ew encs acceptance OT the use of resistors used as isolators between the reactor vessel level instrumentation & the Startrec system.

submitted test reoort* data IEnclosur* 41.

Licensee Pal 1sades 255/92004(DRS) 1/13-17/92, G. Hausman 3

Op*n (255l92004-03(DRSll:

Thfs ftem ramafns open pendfng NRR revf*w and acceptance 2/12-14/92, & 3/16,92

w. Scott of t e use of res stars used as an isolation interface 1n two casesi Licensee R*port f ssued 5/1/ 2 A. Udy,EG&G to provide test raport data to NRR by 12/31/92 (Enclosure 5).

(255/92004-04!DRS)l; Thfs ft*m conc*rns the use of a non-tested, hance, non-approvedsola ion device used to isolate a non-Class lE recorder from the variable containment hydrogen monitor; to NRA bv 12/31/92 (Enclosure 5).

Licensee to provide test report data

ATTACHMENT Page 2 of 2.,_

REGION II I REGULATORY GUIDE 1.97 STATUS Inspection RG 1.97 Sitts Plant Report lud:>ers Inspection Dates lnspector(s)

Rev. lo.

Status

~resolved ltell(s)

Point 266/91010~DRSl 5/13-17/91 M. Kopp 2

Open (266,91010-0lfDRS}j301l91010-0l(DRSll; This Item concerns the lack of 301/91010 DRS Report Issued 6/4/91

c.

~!7t{G&.G qual f1ad 1so at1on for foxboro H-L na fnstrurn9ntatfon at computar and control Beach A.

loops.

This Item remains open pendln~ NRR review and acceptance of th*

license*'* submittal dated July 5, 19 1 (Enclosure 6).

(266l91010-03,DRS}j301,91010-03(DRS}l; The licensee had a number of RG 1.97 control room nstrumen s that had no bean fdantfffad with unfqua Identification as required by RG 1.97.

This item remains open pending NRR review and acceptance of the license*'* submittal* dated July 5, 1991, and t~!~t~~lc!~~~~ ~~~~~~=~~: ~~~ method of control room Instrumentation Quad 254/88027~DRSl l 1/ 14/88-12/ 13{88 A. Gautam 2

Open (254/88027-0l(DRSl*265/88028-0l(DRSll; This item remains open pending NRR 265/88028 DRS Report issued 2/13/88 A. Nolan, EG&.G raviaw ana raso1u't1on OT 'tn* ow" nau'tron flux monftorfng fnstrumantatfon fssua Cities R. McConnlck, EG&.G (Enclosure 7).

(254l88027-03(DRS}j265l88028-03£DRS; This item remains open pending NRR 254/91002~DRSl 1/7-11/91 M. Kopp rav1aw and acceptance of the ad 1t1ona1 fnstrumentatfon/analysf s fdantf ffad fn 265/91002 DRS Report I uu*d 2/27/91 G. Hausman the licensee's submittal dated December 9, 1991. This item concerns the analysis of reactor level Instruments 263-73A and 738 Indication failing high when the recirculation pumps are running (Enclosure 7). (254l88027~05(DRS}j265l88028-05(DRSl}; This Item remains open pending NRR review and acceptance of the Moore solator test report data (Enclosure 7). (254l88027-06(DRS}j265l88028-06(DRSl}; This item remains open pending NRR review and acceg£ance of the Moore solator test raoort data (Enclosure 7l. ~*.}}