ML17111A844
| ML17111A844 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 04/20/2017 |
| From: | Scott Shaeffer NRC/RGN-II/DRS/EB2 |
| To: | Simril R Duke Energy Carolinas |
| References | |
| IR 2017009 | |
| Download: ML17111A844 (13) | |
See also: IR 05000413/2017009
Text
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION II
245 PEACHTREE CENTER AVENUE NE, SUITE 1200
ATLANTA, GEORGIA 30303-1257
April 20, 2017
Mr. Robert T. Simril
Site Vice President
Duke Energy Carolinas, LLC
Catawba Nuclear Station
4800 Concord Road
York, SC 29745
SUBJECT: CATAWBA NUCLEAR STATION, UNITS 1 AND 2 - NOTIFICATION OF
CONDUCT OF A TRIENNIAL FIRE PROTECTION BASELINE INSPECTION AND
REQUEST FOR INFORMATION (NRC INSPECTION REPORT NOS.
05000413/2017009 AND 05000414/2017009)
Dear Mr. Simril:
The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)
staff will conduct a triennial fire protection baseline inspection at Catawba Nuclear Plant, Units 1
and 2. The inspection team will be led by Mr. Rodney Fanner, a Senior Reactor Inspector from
the NRC Region II Office. The team will be composed of personnel from the NRC Region II
Office. The inspection will be conducted in accordance with IP 71111.05XT, Fire Protection -
NFPA 805 (Triennial), the NRC's baseline fire protection inspection procedure, dated
January 31, 2013.
On April 10, 2017, during a telephone conversation between Ms. Sherry Andrews, Catawba
Licensing, and Mr. Rodney Fanner, USNRC RII, our respective staff confirmed arrangements
for an information gathering onsite visit and a two-week onsite inspection. The schedule for the
inspection is as follows:
Information gathering visit:
June 27 - 29, 2017
Week 1 of onsite inspection:
July 24 - 28, 2017
Week 2 of onsite inspection:
August 7 - 11, 2017
The purposes of the information gathering visit are to obtain information and documentation
needed to support the inspection, to become familiar with the Catawba Nuclear Plant fire
protection program, fire protection features, post-fire safe shutdown capabilities, plant layout,
mitigating strategies to address Title 10 of the Code of Federal Regulations (10 CFR) Section
50.54(hh)(2), and, as necessary, obtain plant specific site access training and badging for
unescorted site access.
An initial list of the documents the team will review during the conduct of the inspection is listed
in Enclosures 1 and 2. The team leader will contact you with any additional specific document
requests prior to the information gathering visit.
T. Simril
2
During the information gathering visit, the team will also discuss the following administrative
details: office space and location; specific documents requested to be made available to the
team in their office spaces; arrangements for reactor site access (including radiation protection
training, security, safety, and fitness for duty requirements); and the availability of
knowledgeable plant staff and licensing organization personnel to serve as points of contact
during the inspection.
We request that during the on-site inspection weeks you ensure that copies of analyses,
evaluations, or documentation regarding the implementation and maintenance of the station fire
protection program, including post-fire safe shutdown capability, be readily accessible to the
team for their review. Of specific interest for the fire protection portion of the inspection, are
those documents which establish that your fire protection program satisfies NRC regulatory
requirements and conforms to applicable NRC and industry fire protection guidance (i.e., fire
protection compliance assessment documents). For the 10 CFR 50.54(hh)(2) portion of the
inspection, those documents implementing your mitigating strategies and demonstrating the
management of your commitments for the strategies are of specific interest. Also, personnel
should be available at the site during the inspection who are knowledgeable regarding those
plant systems required to achieve and maintain safe shutdown conditions from inside and
outside the control room, including the electrical aspects of the relevant post-fire safe shutdown
analyses, reactor plant fire protection systems and features, and the station fire protection
program and its implementation.
This letter does not contain new or amended information collection requirements subject to the
Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
requirements were approved by the Office of Management and Budget, under control number
3150 0011. The NRC may not conduct or sponsor, and a person is not required to respond to,
a request for information or an information collection requirement unless the requesting
document displays a currently valid Office of Management and Budget control number.
In accordance with 10 CFR 2.390 of the NRC Rules and Practices, a copy of this letter and its
enclosures will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records System (PARS) component of NRCs document
system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-
rm/adams.html (the Public Electronic Reading Room).
T. Simril
3
Your cooperation and support during this inspection will be appreciated. If you have questions
concerning this inspection, or the inspection team's information or logistical needs, please
contact Rodney Fanner, the team leader in the Region II office at 404-997-4638 or me at
404-997-4521.
Sincerely,
/RA: Jonathan Montgomery for/
Scott M. Shaeffer, Chief
Engineering Branch 2
Division of Reactor Safety
Docket Nos: 50-413; 50-414
License Nos: NPF-35 and NPF-52
Enclosures:
1. Triennial Fire Protection Inspection
Supporting Documentation
2. Mitigating Strategies Supporting
Documentation
cc: Distribution via Listserv
_________________________
SUNSI REVIEW COMPLETE
FORM 665 ATTACHED
OFFICE
RII:DRS
RII:DRS
SIGNATURE
RJF2 VIA
JMM9 FOR
SMS
NAME
RFANNER
SSHAEFFER
DATE
4/20/2017
4/20/2017
4/ /2017
4/ /2017
4/ /2017
4/ /2017
4/ /2017
E-MAIL COPY?
YES
NO YES
NO
YES
NO
YES
NO YES
NO
YES
NO
YES
NO
Enclosure 1
TRIENNIAL FIRE PROTECTION INSPECTION SUPPORTING DOCUMENTATION
The documents and information requested below should generally be made available to the
inspection team during the on-site information gathering visit for the team's use both on-site and
off-site during the inspection. Electronic format is the preferred media, except where specifically
noted, if readily available. The preferred file format is readable and searchable PDF files. If
electronic media is made available via an internet based remote document management
system, then the remote document access must allow inspectors to download, save, and print
the documents in the NRC's regional office. Electronic media on compact disc or paper records
(hard copy) are acceptable. At the end of the inspection, the documents in the team's
possession will not be retained.
Approximately three weeks before the on-site information gathering visit, the following
documents should be made available to the team leader for review in the regional office:
Post-fire Safe Shutdown and / or Alternative Shutdown Analysis (request A.1)
Fire Hazards Analysis (request A.2)
Fire Probabilistic Risk Assessment Summary Document or full PRA Document (If
available)
Fire Risk Evaluations (If available)
Individual Plant Examination for External Events (Fire Chapter ONLY) (request A.3)
Plant layout drawings that identify: C-size paper drawings and electronic copy (request
B.6).
o Plant fire area boundaries;
o Combustible control zone drawings;
o Areas protected by automatic fire suppression and detection; and
o Locations of fire protection equipment.
Based on review of the above documents, the team leader will identify a preliminary list of fire
areas being considered for inspection prior to the on-site information gathering visit. During the
information gathering visit, or shortly thereafter, the fire areas selected for inspection will be
determined.
This document request is based on typical documents that a generic plant might have. As such,
this generic document request is not meant to imply that any specific plant is required to have all
of the listed documents. It is recognized that some documents listed below may not be
available for your plant. In addition, the document titles listed below are based on typical
industry document names; your plant specific document titles may vary.
A.
DESIGN AND LICENSING BASIS DOCUMENTS
A.1
Post-fire Safe Shutdown and / or Alternative Shutdown Analysis.
A.2
Fire Hazards Analysis.
A.3
Individual Plant Examination for External Events (IPEEE) (Fire Chapter ONLY),
including:
- Results of any post-IPEEE reviews; and
- List of actions taken or plant modifications performed in response to the IPEEE
results.
2
A.4
Fire Protection Program and/or Fire Protection Plan.
A.5
List of post-fire safe shutdown or alternative shutdown systems (i.e., safe shutdown
equipment list).
A.6
Fire Protection Systems Design Basis Documents.
A.7
Post-fire Safe Shutdown or Alternative Shutdown Design Basis Document.
A.8
List of applicable NFPA codes and standards and issuance dates (i.e., codes of
record).
A.9
List of deviations from NFPA codes of record.
A.10 NFPA Compliance Review Report.
A.11 Report or evaluation that compares the fire protection program to the NRC Branch
Technical Position (BTP) 9.5-1 Appendix A.
A.12 Electronic copy of licensee submittals and NRC safety evaluation reports that are
specifically listed in the facility operating license for the approved fire protection
program.
A.13 NRC Safety Evaluation Reports for fire protection program and post-fire safe
shutdown or alternative shutdown features.
A.14 NRC approved exemptions for plant fire protection and post-fire safe shutdown or
alternative shutdown features.
A.15 Exemption requests submitted but not yet approved for plant fire protection and post-
fire safe shutdown or alternative shutdown features.
A.16 Facility Operating License (electronic format only).
A.17 Technical Specifications (electronic format only).
A.18 Technical Requirements Manual (electronic format only).
A.19 Updated Final Safety Analysis Report (electronic format only).
B.
GENERAL PLANT DESIGN DOCUMENTS
B.1
Piping and instrumentation diagrams (P&IDs) and legend list for post-fire safe
shutdown or alternative shutdown systems (C-size paper drawings and electronic
copy).
B.2
P&IDs and legend list for fire protection systems, including fire water supply, water
suppression sprinklers & deluge, and CO2 and Halon systems (C-size paper drawings
and electronic copy).
3
B.3
AC and DC electrical system single line diagrams, from off-site power down to the
highest safety-related bus level (typically 4kV, EDG bus), (C-size paper drawings and
electronic copy).
B.4
Single line diagrams for motor control centers (MCCs) that supply post-fire safe
shutdown or alternative shutdown loads (only for selected fire areas) (C-size paper
drawings and electronic copy ).
B.5
Equipment location drawings which identify the physical plant locations of post-fire
safe shutdown or alternative shutdown equipment (C-size paper drawings and
electronic copy).
B.6
Plant layout drawings which identify: (C-size paper drawings and electronic copy)
Plant fire area boundaries;
Combustible control zone drawings;
Areas protected by automatic fire suppression and detection; and
Locations of fire protection equipment.
C. CLASSICAL FIRE PROTECTION
C.1 Fire protection program implementing procedures (e.g., administrative controls,
surveillance testing, fire brigade).
C.2 List of calculations and engineering analyses, studies, or evaluations for the fire
protection system, including the fire water system.
C.3 Hydraulic calculation or analysis for fire protection water system in the selected fire
areas.
C.4 Last two completed surveillance records of fire protection features in the selected fire
areas (detection, suppression, damper inspections, damper tests, penetration
inspections, barrier inspections, etc.).
C.5 List of routine tests, surveillances, and preventive maintenance on fire pumps,
including pump controllers and batteries.
C.6 Last two completed annual fire pump pressure and flow tests.
C.7 Last two completed monthly and/or quarterly fire pump tests.
C.8 Last two completed fire loop flow tests and loop flushes.
C.9 CO2 and Halon initial discharge testing or calculation that determined appropriate
concentrations and soak or hold times can be achieved (only for selected fire areas).
C.10 Last five hot work permits (at power).
C.11 Last five transient combustible permits (at power).
4
C.12 For Fire Brigade Drills, provide the following:
Last drill critique for a drill with off-site fire department support;
Summary of any unsatisfactory drill performance items for last three years; and
Last unannounced drill critique by a qualified individual independent of the
licensee's staff.
C.13 For fire brigade equipment, provide the following:
Procedure for inventory and inspection; and
Most recent inspection and inventory results.
C.14 Fire Brigade Medical Evaluations and Qualifications, including self-contained
breathing apparatus (SCBA) and training lesson plans.
C.15 Electronic copy of the mutual aid agreement for the first-due local fire department
that is currently in effect.
C.16 Flooding analysis for selected fire areas, which demonstrates:
- a fire water pipe break in the selected fire areas wont affect safe shutdown (SSD)
capability for equipment in the selected fire areas;
- a fire water pipe break in an adjacent fire area wont affect SSD capability for
equipment in the selected fire areas;
- hydrostatic rating of any floor penetration seals installed within the fire areas that
are credited with keeping water from leaking into fire areas below.
C.17 Pre-fire plans for the selected fire areas and their adjacent fire areas.
C.18 For Emergency Lighting Units (ELU), provide the following:
List of Preventive Maintenance tasks, frequencies, and bases;
Most recently performed monthly or quarterly functional test;
Most recently performed battery discharge performance test, if applicable;
ELU battery loading analysis;
vendor manual(s);
results of black-out testing (if performed);
Maintenance Rule program information related to the ELU, if applicable; and
Compensatory measures taken when ELU are out of service.
C.19 Impairment Log (for period of 3 months before the start of inspection), for fire
protection features that are out of service.
C.20 List of Fire Protection screening reviews since the last inspection for recent design
changes, modifications, or temporary modifications (e.g., a Generic Letter 86-10
review that screened out).
C.21 List of fire protection system design changes completed in the last three years
(including their associated 10 CFR 50.59 and Generic Letter 86-10 evaluations).
5
C.22 List of penetration seal work, re-work, or installation activities in the last three years.
C.23 List of fire wrap work, re-work, or installation activities in the last three years.
C.24 Fire protection system health reports for the two most recent years.
C.25 Fire protection program health report for the two most recent years.
C.26 Emergency lighting system health reports for the two most recent years.
C.27 Licensee evaluation of industry operating experience, related to the Fire Protection
Program for the three most recent years.
D. ELECTRICAL
D.1 Identify whether the cables in the selected fire areas are predominantly Thermoset or
Thermoplastic. Specifically identify any Thermoplastic cable in the selected fire
areas.
D.2 Breaker and fuse coordination calculation for post-fire safe shutdown or alternative
shutdown equipment (only for selected fire areas).
D.3 Administrative or configuration control procedures that govern fuse replacement (e.g.,
fuse control procedures).
D.4 Maintenance procedures that verify breaker over-current trip settings to ensure
coordination remains functional, for post-fire safe shutdown or alternative shutdown
equipment.
D.5 Electrical system health reports for the two most recent years.
D.6 Last completed preventive maintenance of those components as tested from the safe
shutdown or alternative shutdown panel.
D.7 Schematic or elementary diagrams for circuits to be reviewed, as requested by
inspector (C-size paper drawings and electronic copy).
D.8 Cable routing for components and equipment credited for post-fire safe shutdown or
alternative shutdown (only for selected fire areas).
D.9 List of post-fire safe shutdown or alternative shutdown design changes completed,
since the last inspection.
E.
SPURIOUS FIRE INDUCED CIRCUIT FAULTS
E.1
List of identified fire induced circuit failure configurations (only for selected fire areas).
E.2
Multiple Spurious Operation (MSO) Expert Panel Report.
6
E.3
Corrective actions for fire-induced circuit failures, both single and multiple spurious
actuations for the selected fire areas.
F.
OPERATIONS
F.1
List of calculations and engineering analyses, studies, or evaluations for the safe
shutdown or alternative shutdown methodology.
F.2
List of licensed operator Job Performance Measures (JPMs) for operator manual
actions required by post-fire safe shutdown or alternative shutdown.
F.3
List of non-licensed operator training associated with post-fire safe shutdown or
alternative shutdown manual actions that would be performed by a non-licensed
operator (including JPMs, in-field training walkdowns, simulations, or initial
qualification).
F.4
List of lesson plans for post-fire safe shutdown or alternative shutdown training for
licensed and non-licensed operators.
F.5
For operator manual actions (OMAs) provide the following:
Manual Action Feasibility Study;
Operator Time Critical Action Program;
Time lines for time-critical OMAs; and
Time line validations;
Environmental and habitability evaluations for post-fire operator manual actions
(temperature, smoke, humidity, SCBAs, etc.).
F.6
Thermal hydraulic calculation or analysis that determines the time requirements for
time-critical manual operator actions.
F.7
Operating procedures for post-fire safe shutdown from the control room with a
postulated fire in the selected fire areas.
F.8
Operating procedures for post-fire safe shutdown or alternative shutdown from
outside the control room.
F.9
For safe shutdown equipment and tools, provide the following:
Procedure for inventory and inspection; and
Most recent inspection and inventory results.
F.10 List of procedures that implement Cold Shutdown Repairs.
F.11 For Cold Shutdown Repairs, provide the following:
Procedure for inventory and inspection (i.e., needed tools, material, etc.); and
Most recent inspection and inventory results.
7
F.12 Calculation or analysis that demonstrates pressurizer level will remain within the
indicating range for a PWR, or reactor water level will remain above the top of active
fuel for a BWR, at the safe shutdown or alternative shutdown panel, in accordance
with the requirements of 10 CFR 50 Appendix R III.L performance goals.
F.13 For Radio communications, provide the following:
Communications Plan for firefighting and post-fire safe shutdown manual actions;
Repeater locations;
Cable routing for repeater power supply cables;
Radio coverage test results; and
Radio Dead Spot locations in the plant.
F.14 NRC approved exemption requests for operator manual actions for
10 CFR 50 Appendix R III.G.2 fire areas.
F.15 Exemption requests submitted but not yet approved, for operator manual actions for
10 CFR 50 Appendix R III.G.2 fire areas.
G. ADMINISTRATIVE CONTROL, OVERSIGHT, AND CORRECTIVE ACTION PROGRAMS
G.1 Corrective actions for fire-induced circuit failures (including but not limited to NRC
IN 92-18), both single and multiple spurious actuations (only for selected fire areas).
G.2 Corrective actions associated with post-fire safe shutdown or alternative shutdown
G.3 Internal and external self-assessments, peer assessments, and audits of fire
protection activities for the last three years.
G.4 Internal and external self-assessments, peer assessments, and audits of post-fire
safe shutdown or alternative shutdown capabilities for the last three years.
G.5 List of condition reports for the fire protection system for the last three years.
G.6 List of condition reports for emergency lighting units for the last three years.
G.7 List of condition reports for post-fire safe shutdown (SSD) or alternative shutdown
(ASD) issues for the last three years. This includes issues affecting the SSD or ASD
analysis, fire hazards analysis, SSD or ASD operating procedures and/or training,
timeline evaluations for operator actions, and supporting engineering evaluations,
analysis, or calculations.
G.8 List of all Generic Letter 86 - 10 evaluations.
G.9 Copy of all Generic Letter 86 - 10 evaluations performed in the last three years.
G.10 All fire loading calculations and evaluations performed (only for selected fire areas
and their adjacent fire areas).
Enclosure 2
MITIGATING STRATEGIES SUPPORTING DOCUMENTATION
H. 10 CFR 50.54(hh)(2) MITIGATING STRATEGIES DOCUMENTS
H.1 List of all changes to regulatory commitments made to meet the requirements of Title
10 of the Code of Federal Regulations (10 CFR) 50.54(hh)(2).
H.2 List of procedures and guidelines that were revised or generated to implement the
mitigating strategies. These could be extensive damage mitigation guidelines
(EDMGs), severe accident management guidelines (SAMGs), emergency operating
procedures (EOPs), abnormal operating procedures (AOPs), etc.
H.3 A matrix that shows the correlation between the mitigation strategies identified in
Nuclear Energy Institute 06-12, Revision 2, "B.5.b Phase 2 & 3 Submittal Guideline,"
issued December 2006, and the site-specific procedures or guidelines that are used
to implement each strategy.
H.4 List of engineering evaluations or calculations that were used to verify the
engineering bases for the mitigating strategies.
H.5 Piping and instrumentation diagrams (P&ID) and legend list or simplified flow
diagrams for systems relied upon in the mitigating strategies. These could be the
type used for training (C-size paper drawings and electronic copy).
H.6 List of modification packages or summary descriptions of modifications with simplified
drawings, for necessary facility changes to implement the mitigating strategies.
H.7 List of routine tests, surveillances, and preventive maintenance for equipment and
tools needed to implement 10 CFR 50.54(hh)(2) strategies.
H.8 For equipment and tools needed to implement 10 CFR 50.54(hh)(2) strategies,
provide the following:
Procedures for inventory, testing, and inspection; and
Most recent inspection, inventory, and testing results;
Copies of the last two completed performance tests, surveillances, and
preventative maintenance performed on the pumps, including the pump
controllers and batteries.
H.9 List of 10 CFR 50.54(hh)(2) strategies, if any, which have implementing details that
differ from that documented in the submittals or the safety evaluation report.
H.10 Site general arrangement drawings that show the majority of buildings and areas
referenced in 10 CFR 50.54(hh)(2) documents (C-size paper drawings and electronic
copy).
H.11 Training records, training matrix, and lesson plans related to 10 CFR 50.54(hh)(2).
2
H.12 Copies of memoranda of understanding (MOU), (e.g., with local fire departments)
required to implement any mitigating strategies.
H.13 Docketed correspondence for 10 CFR 50.54(hh) to include license amendment
requests (LARS); Safety Evaluation Reports (SER); Request for Information (RFI)
and associated responses; and other pertinent documents.