Person / Time
Site: Nine Mile Point  Constellation icon.png
Issue date: 08/11/1998
From: Conte R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mueller J
NIAGARA MOHAWK POWER CORP.
Shared Package
ML17059C202 List:
References
50-220-98-13, 50-410-98-13, NUDOCS 9808180006
Download: ML17059C201 (8)


See also: IR 05000220/1998013

Text

CATEGORY 2

)

REGULATORY INFORMATION DISTRIBUTION SYSTEM

(RXDS)

ACCESSION NBR:9808180006

DOC.DATE: 98/68/11

NOTARIZED: NO

FACIL:50-220 Nine Mile Point Nuclear Station, Unit 1, Niagara,Powe

50-410 Nine Mile Point Nuclear Station, Unit 2, Niagara

Moha

AUTH.NAME

AUTHOR AFFILIATION

CONTE,R.J.

Region

1 (Post

820201)

RECIP . NAME

RECIPIENT AFFILIATION

MUELLER,J.H.

Niagara

Mohawk Power Corp.

$ s

SUBJECT:

Forwards insp repts

50-220/98-13

6 50-410/98-13

on

980720-24.No violations noted.

DOCKET

05000220

05000410

DISTRIBUTION CODE: IE01F

COPIES

RECEIVED:LTR

ENCL

SIZE:

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

NOTES:

E

RECIPIENT

ID CODE/NAME

PD1-1

PD

j

INTERNAL: ACRS

A

ILE CE

PM/PECB

NUDOCS-ABSTRACT

OGC/HDS3

TERNAL: LITCO BRYCE,J H

NRC PDR

COPIES

LTTR ENCL

1

1

2

2

1

'

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

HOOD,D

AEOD/SPD/RAB

DEDRO

NRR/DRCH/HOHB

NRR/DRPM/PERB

OE DIR

RGN1

FILE

01

NOAC

NUDOCS FULLTEXT

COPIES

LTTR ENCL

1

1

1'

1

1

1

1

1

1

1

1

1

1

1

1

1

1

CAnaD

~aOV

,i NRCFLOPPy

'

NOTE TO ALL "RZDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DZSTRIBUTION LISTS

OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL

DESK

(DCD)

ON EXTENSION 415-2083

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

19

ENCL

19

0

August ll, 1998

Mr. John H. Mueller

Chief Nuclear Officer

Niagara Mohawk Power Corporation

Nine Mile Point Nuclear Station

Operations Building, 2nd Floor

P.O. Box 63

Lycoming, NY 13093

SUBJECT:

NRC SPECIAL INSPECTION REPORT NO. 50-220/98-13 and 50-410/98-13

Dear Mr. Mueller:

This report transmits the findings of a special inspection conducted by NRC inspectors at

the Nine Mile Point Nuclear Station, Units

1 and 2, from July 20-24, 1998. At the

conclusion of the inspection, the findings were discussed with members of your staff.

This inspection was conducted in response to several personnel errors, by Unit 1

operators, that occurred during 1998. These errors included, in part, a licensed Senior

Reactor Operator briefly leaving the control room, the failure to properly position a valve in

the containment spray system following testing and the failure to implement required

Technical Specification actions following the failure of a raw water/containment spray

isolation valve.

Several causes contributed to these deficiencies including weak self

checking, poor independent verification, and an inattention to detail by plant operators.

Other causes contributing to the decline in operations performance overall were a lack of

clearly documented management standards

and expectations

and the failure by operations

management to hold operator's accountable.

The inspectors found that your oversight and self assessment

programs had identified this

decline in operations performance.

Your staff had appropriately responded to these

findings and had recently implemented several corrective actions to improve your

organization.

These improvements included the establishment of a permanent operations

management team and the establishment of clearly documented

standards

and

expectations for the operations staff. The inspectors found that the operator's were aware

of the new standards

and expectations

and were appropriately implementing them.

However, these changes

have only recently been established

and additional time is

necessary to validate the success of these improvements on reducing the personnel error

rate and improving overall performance.

9808i80006 9808ii

PDR

ADOCK 05000220

8

PDR

J

Mr. John H. Mueller

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter,

its enclosures,

and your response will be placed in the NRC Public Document Room.

Sincerely,

ORIGINALSIGNED BY:

Richard J Conte, Chief

Operator Licensing and Human

Performance Branch

Division of Reactor Safety

Docket Nos.

50-220; 50-410

License Nos.

DPR-63; NPF-69

1

Enclosures:

NRC inspection Report No. 50-220/98-13and 50-410/98-13

cc w/enclosure:

G. Wilson, Senior Attorney

M, Wetterhahn, Winston and Strawn

J. Rettberg, New York State Electric and Gas Corporation

P. Eddy, Electric Division, Department of Public Service, State of New York

C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law

J. Vinquist, MATS, Inc.

F. Valentino, President, New York State Energy Research

and Development Authority

J. Spath, Program Director, New York State Energy Research

and Development Authority

Mr. John H. Mueller

Distribution w/encl:

H. Miller, RA/W. Axelson, DRA (1)

D. Screnci, PAO (1)

Region

I Docket Room (with concurrences)

Nuclear Safety Information Center (NSIC)

PUBLIC

NRC Resident Inspector

J. Wiggins, DRS

L. Nicholson, DRS

R. Conte, DRS

J. Trapp, DRS

L. Doerflein, DRP

B. Cook, DRP

R. Junod, DRP

DRS File

Distribution w/encl: (VIAE-MAIL)

B. McCabe, Rl EDO Coordinator

B. Norris - Nine Mile Point

S. Bajwa, NRR

D. Hood, NRR

M, Campion, Rl

Inspection Program Branch (IPAS)

R. Correia, NRR

DOCUMENT NAME: G:iOLHPiCONTEiNMP9813.INS

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enctosure

"E" = Copy with attachment/enctosure

"N"~ No

copy

OFFICE

NAME

DATE

RI/DRS

JTrapp

08/06/

8

RI D

08/6/98

RI/DRS

RConte