Docket No. 50-220 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 December 18, 1991 LICENSEE: Niagara Mohawk Power Corporation FACILITY: Nine Mile Point Nuclear Station Unit No.
1
SUBJECT:
MEETING MINUTES REGARDING THE DECEMBER 3, 1991, MEETING TO DISCUSS THE RESCHEDULING OF CERTAIN MODIFICATIONS AT NINE MILE POINT, UNIT NO.
1 A meeting was held in the NRC One Itlhite Flint North Office in Rockville, Maryland, with Niagara Mohawk Power Corporation (NMPC) and NRC staff representatives to discuss NMPC's proposal to reschedule the implementation of four modifications at Nine Mile Point 1.
Enclosure 1 is a list of meeting attendees.
The handout material used by the licensee during the meeting is attached as Enclosure 2.
During the meeting, NMPC proposed to reschedule the following four modifications:
1.
Replacement of four emergency condenser condensate return line valves (39-03, 39-04, 39-05, and 39-06) to permit 10 CFR Part 50, Appendix J, leak testing of these valves.
This modification would be rescheduled from the 1992 refueling outage to the 1994 refueling outage.
2.
Replacement of four shutdown cooling system isolation valves (38-01, 38-02, 38-12, and 38-13) to permit 10 CFR Part 50, Appendix J, leak testing of these valves.
This modification would be rescheduled from the 1992 refueling outage to the 1994 refueling outage.
3.
Replacement of the LPRM isolator rack (including 60 signal isolators) in the Auxiliary Control Room with improved equipment.
This modification would be rescheduled from the 1992 refueling outage to the 1994 refueling outage.
4.
Replacement of the control rod drive selector switch to preclude the potential for simultaneous withdrawal of two control rods.
This modification would be rescheduled from the 1994 refueling outage to the 1992 refueling outage.
NMPC described its plans for the 1992 and 1994 refueling outages.
The 1992 outage will focus on modifications to electrical and control systems while the 1994 outage will focus on modifications to mechanical/structural systems.
Therefore, NMPC proposed delaying modifications 1 and 2 to the 1994 outage PDR ADOCII,'5000220 P
(ag MBC IlIt.g Cggl'Eg gyp'(,I
4 December 18, 1991 while rescheduling modification 4 to the 1992 outage.
These schedule changes would be consistent with the focus of other activities planned for these outages.
NMPC proposed delaying modification 3 until the 1994 outage since it would then coincide with Phase II of the plant computer upgrade thereby ensuring system compatibility.
NMPC also stated that the 1994 outage will include a
chemical decontamination which is expected to reduce the occupational exposure associated with modifications 1 and 2 by approximately 100 person-rem as compared with performing there modifications during the 1992 outage when chemical decontamination will not be used.
The NRC staff agreed that NMPC's proposal was reasonable.
Therefore, NMPC will promptly submit requests for schedular exemptions for modifications 1 and 2.
These requests will supersede previously issued schedular exemptions for these modifications which are valid until the 1992 refueling outage.
NMPC will also submit a letter updating its commitments for modifications 3 and 4
to reflect the agreements reached during this meeting.
Enclosures:
1.
List of Attendees 2.
Licensee Handout Material Donald S. Brinkman, Senior Project Manager Ploject Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc w/enclosures:
See next page
Mr. B. Ralph Sylvia Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Unit Ho.
1 CC:
Mr. Mark J. Wetterhahn, Esquire Winston 5 Strawn 1~00 L Street, NW.
Washington, D.C.
20005-3502 Supervisor Town of Scriba Route 8, Box 382
- Oswego, New York 13126 Mr. Joseph F. Firlit Vice President - Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Resident Inspector U.S. Nuclear Regulatory Commission Post Office Box 126
- Lycoming, New York 13093 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
- Syracuse, Hew York 13202 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Ms. Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor
- Albany, New York 12223 Mr. Kim Dahlberg Unit 1 Station Superintendent Nine Mile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Mr. David K. Greene Manager Licensing Niagara Mohawk Power Corporation 301 Plainfield Road
- Syracuse, New Yor k 13212 Charlie Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, New York 1027]
Mr. Paul D. Eddy State of New York Department of Public Service Power Division, System Operations 3 Empire State Plaza
- Albany, New York 12223
I P
Enclosure 1
Attendance List December 3, 1991, meeting to discuss proposed rescheduling of four modifications at NMP-l.
t<ame Donald S. Brinkman Conrad HcCracken Jack Kudrick George Schwink Robert A. Capra Larry Phillips K. A. Dahlberg C. D. Terry D. K. Greene William R. Yaeger David E. Sandwick Lee A. Klosowski Louis E. Pisano Gary 'Hilson Hark J. Wetterhahn Stanley W. Wilczek, Jr.
Rich Laura D. R. Haverkamp Hukam Garg Title Senior Project Manager Chief Section Leader Senior Engineer Director, PDI-1 Chief, Core Perf. Section Plant Manager - Unit 1 VP-Nuclear Engineering Manager-Licensing Mgr.
NMP 1 Engineering Supv-NMP 1 Proj. Mgmt.
Gen.
Supv. Unit 1 Design Mgr Work Control/Outage Mgmt.
Managing Attorney Attor ney V.P. Nuclear Support Resident Inspector
- Chief, RP Section 1.B.
Senior Electrical Eng.
Or anization NRC/NRR/PDI-1 NRC/NRR/DST/SPLB NRC/NRR/DST/SPLB NRC/NRR/DST/SRXB NRC/NRR/P DI-1 NRC/NRR/DST/SRXB NHPC NMPC NMPC NMPC NHPC NMPC NMPC NMPC Winston
& Strawn NHPC NRC NRC/RI NRC/NRR/DST/S ICB
t'C
OUTAGE MANAGEMENT COM DECEMBER 3, 1991
AGENDA
~
PURPOSE
~
OUTAGE PHILOSOPHY
~
OUTAGE SPECIFICS
~
PROPOSED CEGWGES
~
NMPC EXPECTATIONS K. A. DAHLBERG C. D. TERRY PAGE 1
I
~
TO PROPOSE REALIGNMENTOF NMPC COMMITMENTS RELATED TO THE 1992 AI'6) 1994 NINE MILEPOINT UNIT 1 REFUELING OUTAGES, PAGE 2
'I l
OUTAGE PKllOSOPHY
~
1992 REFUELING OUTAGE FOCUS ON SAFETY SYSTEM RELIABILITYWITH ELECTRICAL EMPHASIS CLOSES MANYLONG STANDING ELECTRICALAND CONTROL CONCERNS FROM THE EXTENDED REFUELING OUTAGE PROVIDE OPERATORS WH'H SYSTEMS AND CONTROLS TO BRING PLANT THROUGH OUTAGE FIRST OUTAGE TO IMPLEMENTSHUTDOWN SAFETY ISSUE INITIATIVE ll
~
1994 REFUELING OUTAGE FOCUS ON REACTOR VESSEL AND PRIMARY CONTAINMENTWITH MECHANICAL/STRUCTURAL EMPHASIS PERFORM CHEM DECON AND DRAIN REACTOR VESSEL ONLY ONCE COMPLETE CLOSEOUT OF APPENDIX J ITEMS PAGE 3
BENEFITS
~
SAFETY
- REDUCES COMPLEXITYOF BOTH 0UTAGES
- MAXIMIZES/OPTIMIZESSYSTEM
, AVAILABILITY
- PRESENT SCHEDULING OF THE APP. J MOD. RESULTS IN A MARGINALCOST BENEFIT FOR A CHEM DECON IN 1992 AND 1994
- REALIGNINGAPP. J MOD. TO 1994 RESULTS IN A POSITIVE COST BENEFIT-FOR JUSTIFYING A CHEM DECON IN 1994 (SAVES APPROXIMATELY 100 MAN REM)
~
RADWASTE
- DECON ONLYIN 1994 WILLSAVE RADWASTE PROCESSING AND VOLUME
~
ECONOMICS
- REDUCES TOTALOUTAGE TIME
0 l
t)
t t
1992 OUTAGE SPECIFICS SAFETY SYSTEM RELIABILITY/ELECTIRICAL EMPHASIS
~
MAJOR MODIFICATIONS REACTOR BUILDINGEMERGENCY VENT SYSTEM LOGIC BYPASS OF, NON-COINCIDENT SCEVdrf LOGIC IN SHUTDOWN REPLACEMENT OF BALI'ERYCHARGER AND RPS MOTOR-GENERATOR SETS WITH STATIC DEVICES DETAILEDCONTROL ROOM DESIGN REVIEW PHASE III/
REG. GUIDE 1.97
~
WIDE RANGE DRYWELLWATER LEVEL INSTRUMENTATION
~
ADDITIONALDRYWELLTEMPERATE&
INSTRUMENTATION
~
TORUS PRESSURE REDUNDANT INSTRUMENTATION
~
ADDITIONALREACTOR BUILDINGTEMPERATURE SENSORS
~
REACTOR BUILDINGAREA RADIATIONMONITOR RE-FLASH
~
ADDITIONALCORNER ROOM LEVEL INSTRUMENTATION
~
EMERGENCY RELIEF VALVEMONITORING
~
ELIMINATENUISANCE ALATMS-OFF GAS PREHEATER/RECOMBINER PAGE 5
t t
1992 OUTAGE SPECIFICS SAFETY SYSTEM RELIABILITY/ELECTjRICAL EMPHASIS PLANT PROCESS COMPUTER UPGRADE - PHASE I INSTALLATIONOF NON-SAFETY RELATED BATTERIES EPK)ROGEN-OXYGEN ANALYZERUPGRADE FEEDWATER FLOW CONTROL VALVEREPLACEMENT EDG COOLING WATER BLOCKINGVALVES TORUS MID BAY SUPPORT gF REQUI:RED)
CRD SELECTOR SWITCH (POTENTIAL)
(
1994 OUTAGE SPECIFICS SAFETY SYSTEM RELIABILITY/MECHANICAL STRVC EMPHASIS
~
MAJOR MODIFICATIONS APP J - SHUTDOWN COOLING, EMERGENCY COOLING, CONTAINMENTSPRAY REACTOR VESSEL BELTLINEINSPECTION CORE SPRAY MINIMUMFLOW RECIRC. LINE (BULLETIN88-04)
REMOVE FEEDWATER SPARGER FOR NOZZLE INSPECTION (NUREG 0619)
PRIMARY SYSTEM DECON AI'G) DRAIN DOWN GL 89-10 MOV TESTING PLANT PROCESS COMPUTER UPGRADE-PHASE II TORUS MID-BAYSUPPORTS (IF REQUI:RED)
PAGE 7
PROPOSED CHANGES
~
ACTIVITIESREQUESTED TO BE REALIGNED FROM 1992 TO 1994 REFUELING OUTAGE APP J/SHUTDOWN COOLING ISOLATIONVALVE REPLACEMENT APP J/EMERGENCY COOLING ISOLATIONVALVE REPLACEMENT
~
TECHNICALBASIS FOR EXEMPTION STILL APPLIES
~
RESULTS IN REDUCTION IN MAN-REMEXPOSURE AND RADWASTE GENERATION PROCESS COMPUTER ISOLATIONAMPS
~
UPGRADE BEING PERFORMED IN A TWO PHASE PROGWdvI
~
IN CONJUNCTION WH'H THE ABOVE PROPOSED CHANGES ACTIVITIESWHICH WOULD BE REALIGNED FROM 1994 TO 1992 REFUELING OUTAGE DUALCONTROL ROD WITHDRAWALMODIFICATION PAGE 8
)
I'AG'C EXPECTATIONS
~
NMPC TO FOLLOW UP THIS MEETING WITH EXEMPTION REQUEST FOR THE 1992 APPENDIX J ITEMS
~
NMPC TO FOLLOW UP THIS MEETING WH'H LETTER REGARDING PROCESS COMPUTER ISOLATION AMPS
~
NEED NRC APPROVAL BY FEBRUARY 1992 00139000 PAGE 9
)
December 1'7; 1991 while rescheduling modification 4 to the 1992 outage.
These schedule changes would be consistent with the focus of other activities planned for these outages.
NMPC proposed delaying modification 3 until the 1994 outage since it would then coincide with Phase II of the plant computer upgrade thereby ensuring system compatibility.
NMPC also stated that the 1994 outage will include a
chemical decontamination which is expected to reduce the occupational exposure associated with modifications 1 and 2 by approximately 100 person-rem as compared with performing there modifications during the 1992 outage when chemical decontamination will not be used.
The NRC staff agreed that NMPC's proposal was reasonable.
Therefore, NMPC will promptly submit requests for schedular exemptions for modifications 1 and 2.
These requests will supersede previously issued schedular exemptions for these modifications which are valid until the 1992 refueling outage.
NMPC will also submit a letter updating its commitments for modifications 3 and 4
to reflect the agreements reached during this meeting.
Original signed by
Enclosures:
1.
List of Attendees 2.
Licensee Nandout Material Donald S. Brinkman, Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc w/enclosures:
See next page DISTRIBUTION
~B NRC L Local PDRs PDI-1 Reading File T. Murley/F. Miraglia J. Partlow S. Varga J.
Calvo D. Brinkman C. Vogan OGC E. Jordan C. Cowgill NRC Participants ACRS,(10)
,R. Lobel, Reg'ion I 17-G-21 OFC: LA:PD I-1 NAIIE:CVogan g WW
~
0 W
DATE:12/)g/91 PM:PDI-1 ~
.'D:PDI-1 AJ, DBrinkman/vsb
- RCapra ~
WS ~
WWWWW 12/I I/91:12/ g /91
~
W WI OFFICIAL RECORD COPY Document Name:
SUMMARY
12/3/91
'h'l
~
b I
il
,1
~ Jh I
I I
rr I
I
~
p yh ~I n /
ll Ih 1h 1
J'y rl nhI 1 lh I
II J
nl, h
1 n
1
, b
'J 1
1 I
b II 1
h I,h
~
1
~
hh 1 ~
I 1
I 1 1 'I'