REGULATORY INFORMATION DISTRIBUTION SYSTEM

( R I DS

)

hCCESSION

NBR: 8711040372

DOC. DATE: 87/10/29

NOTARIZED:

NO

FACIL: 50-220 Nine Mile Point Nuclear Stations

Uni t ii Niagara

Powe

50-410 Nine Mile Point Nuclear Station.

Unit 2,

Niagara

Moha

AUTH. NAME

AUTHOR AFFILIATION

WENZ INGERi E. C.

Reg i on ii Of c

of the Direc tor

RECIP. NAME

RECIPIENT AFFILIATION

MANGANiC. V.

Niagara

Mohawk Power

Corp.

SUBJECT:

Forwards

Insp Repts

50-220/87-18

Px 50-410/87-37

on

870831-1004

5 notice of violation.

DISTRIBUTION CODE:

IE01D

COPIES

RECEIVED: LTR

ENCL

SIZE:

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

NOTES: 21

DOCVET e

05000220

05000410

05000410

REC IP IENT

ID CODE/NAME

PDi-1

PD

HAUGHEYr M

INTERNAL:

ACRS

DEDRO

NRR/DOEA

DIR

NRR/DREP /RP 8

NRR/PMAS/ ILRB

OGC/HDS1

RES

DEPY GI

TERNAL:

LPDR

NSIC

COPIES

LTTR ENCL

1

1

2

2

2

2

,1

1

2

2

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

8ENEDICT. R

BENEDICT'

  • EOD

NRR

MOR ISSEAUi D

NRR/DREP/EPB

NRR/DRIS DIR

EBERMANi J

RGFL

RGN1

FILE

01

NRC

PDR

COPIES

LTTR ENCL

2

2

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

26

ENCL

26

~

'

'

Docket No. 50-220

Docket No. 50-410

I9 OcT 1987

Niagara

Mohawk Power Corporation

ATTN:

Mr. Charles

V. Mangan

Senior Vice President

Nuclear

301 Plainfield Road

Syracuse,

New York

'13212

Gentlemen:

Subject:

Inspection

Report

No. 50-220/87-18

and 50-410/87-37

This letter transmits

our report of the routine inspection

conducted

by Messrs.

W. Cook,

C. Marschall

and

W. Schmidt of this office on August 31,

1987 through

October 4,

1987 at Nine Mile Point Units

1 and 2, Scriba,

New York.

A summary

of the findings was presented

to Mr. T. Perkins

and other

members of your staff

at the conclusion of the inspection.

Based

on our review,

a violation of 10 CFR 50 Appendix

R and your Fire.

Protection

Program

was identified at Unit 2.

This violation indicates that

the Operations staff did not properly implement

a requirement to disable

valves important to the continued operation of safety

systems,

in the event of

. a fire.

This violation has

been categorized

by severity level according to

10 CFR Part 2, Appendix

C (Enforcement Policy).

You are required to respond to

this violation and in preparing your response

you should follow the

instructions in Appendix A.

The response

required

by this letter is not subject to the clearance

procedures

of the Office of Management

and Budget as required

by the Paperwork

Reduction Act of 1980,

PL 96-511.

We appreciate

your cooperation.

7 i g040372 87 ~0~~+~~0

PDR

ADOCK 0

PDR

8

Sincerely,

P

- g~ Signed Byi

Edward

C. Wenzinger,

Chief

Projects

Branch

No.

2

Division of Reactor Projects

Enclosures:

l. Appendix A, Notice of Violation

2.

NRC Region I, Combined Inspection

Report

No. 50-220/87-18

and 50-410/87-37

OFFICIAL RECORD

COPY

CIR

NMP 87-18/37

0001.0.0

10/29/87

'

Niagara

Mohawk Power Corporation

RSOCT

13o

cc w/encls:

Connor 5 Wetterhahn

John

W. Keib, Esquire

T.E.

Lempges,

Vice President,

Nuclear Generation

T.J. Perkins,

General

Superintendent

T.W.

Roman, Station Superintendent,

Unit

1

R.B. Abbott, Station Superintendent,

Unit 2

J.C. Aldrich, Unit

1 Superintendent

of Operation

R.G. Smith, Unit 2 Superintendent

of Operations

J.A. Perry,

Vice President,

Quality Assurance

A;Z. Pinter,

NMPC Site Licensing

C.G.

Beckham,

Manager Nuclear Quality Assurance

W.A. Hansen,

Manager Corporate Quality Assurance

Troy B. Conner, Jr.,

Esquire

Director,

Power Division

Department of Public Service,

State of New York

Public Document

Room

(PDR)

Local Public Document

Room ( LPDR)

Nuclear

Safety Information Center

(NSIC)

NRC Resident

Inspector

State of New York

Brent Clayton,

EDO

Operations

bcc w/encls:

Region I Docket

Room (with concurrences)

Management Assistant,

DRMA (w/o encl.s)

C. Anderson,

DRS

J.R.

Johnson,

Section Chief,

DRP

R.A. Benedict,

Licensing Project Manager,

Unit

1

M.F. Haughey,

Licensing Project Manager, Unit 2

State

Liaison Officer (SLO)

RI:D

Johnson/rhl

10/Z~/87

R

P

W

ger

10$,$87

OFFICIAL RECORD

COPY

CIR NMP 87-18/37 - 0002.0.0

10/29/87