Model 3196ST Size 1x1-1/2-8 W/150 Lb Raised Face Flanges & Rh Rotation:Fabricated Steel Bedplate W/Drip Pan and Drain on Pump End
ML17055B119
Person / Time
Site: Nine Mile Point 
Issue date: 06/05/1980
From:
GOULDS PUMPS, INC.
To:
NIAGARA MOHAWK POWER CORP.
Shared Package
ML17055B117 List:
References
CON-12177 N773980-1, NUDOCS 8601230335
Download: ML17055B119 (1)


Text

GOULDS PUMPS)INC.

SENECA FALLS s N.Y.O U.S.A.

MODEL 3I96sr SIZE I x I-I/28 W/150 LB RAISED FACE FLANGES

& R.H. ROTATION FABRICATED STEEL BEDPLATE W/ DRIP PAN AND DRAIN ON PUMP END MIN. PULL SPACE 8

FOR ROTOR REMOVAL L & N THERMOCOUPLE Q2 (ONE EACH PUMP BEARING) 1)I DISCHARGE 8

19 16 7

I 8

CONDUIT BOX MAY BE ROTATED IN 900 STEPS I

2 Q)

I 7

8 5

5 8

'e MOTOR 10 8

II I

8 e

18 I

2 PUMP C.

II I

I-2 1

92 4-I 2

I I

2 28 7

I" NPT GROUNDING I

PADS 16 C.G ASSY Q

S I

4 4

NOTES 2, 8 16 GROUNDING PADS 1.0CATED DIAGONALLY OPPOSITE 4

II i8 HOLES 16 le-'7" 8

I 2

99-2 42 I

I 4

I I

2 IB GATI APERTUgg CARD ALL DIMENSIONS ARE IN INCHES.

DRAWING IS NOT TO SCALE.

COUPLING GUARD FURNISHED BY GOULDS.

INSTALL FOUNDATION BOLTS IN PIPE SLEEVES.

ALLOW 9/4'O I-I/2<< FOR GROUTING.

5I INDICATES APPROXIMATE CENTER OF GRAVITY.

PUMP MANUFACTURED PER SECTION III1 CLASS 2 OF THE ASME BOILER & PRESSURE VESSEL CODE, 1974 EDITION THRU WINTER 1976 ADDENDA.

PUMP FLANGES CONFORM TO ISO LB ANSI AND ARE RAISED FACE.

+

2 RHS NP2= RESIDUAL HEAT REMOVALSYSTEM PRESS.

PUMP 2CSL3FP2 = LOW PRESS. CORE SPRAY SYSTEM PRESS.

PUMP 2CSH)FP2 =HIGH PRESS. CORE SPRAY SYSTEM PRESS' PUMP 2 ICSX-P2 = REACTOR CORE ISOLATIONCOOLSYSTEM PRESS. P U MP TAPPED OPENINGS NO. QTY I

4 SIZE I/2 8

A PURPOSE 2

1 S

2 6

I 7

I 9/8 OIL DRAIN 9/4 BEDPLATE DRAIN 9/8 CASE DRAIN I/4 GAUGE CONN I/4 GLAND FLUSH I/4 CASE BY-PASS Ql MECHANICAL SEAL SPECIFICATIONS MFR.

~DURAMETALL)

TYPE PTO

CODE, EUSEFU/U GLAND TYPE FLUSH GLAND MATERIAL 916 SS (N.R.

Ql MOTOR SPECIFICAT:ONS MFR.

WESTINGHOUSE FRAME 2 I S T H.P.

10 R.P.M.

94SS ENCLOSURE ODP PHASE 9

HERTZ 60 VOLTAGE S7'S SERVICE FACTOR

1. I S PUMP CHARACTERISTICS DESIGN FLOW SO
GPM, DE,SIGN HEAD

S FT DESIGN PRESSURE IBS PSIG DESIGN TEMPERATURE 212 oF HYDRO TEST PRESS.

278 PSIG WEIGHTS PUMP

, IOTOR, BEDPLATE TOTAL WET 102 LB 140 LB 17S I 8 LB DRY 100 LB.

140 18 17S 1.8.

4 I S LB, BOLT DATA SIZE MATERIAL FOUNDATION S/8 SA-907 COUPLING SPECIFICATIONS MFR.

THOMAS TYPE DBZ -C W/SS DISCS SIZE 126 SERVICE FACTOR 4

Q)

TORQUE 70 QS

)

Caafla lao Oaawlas Aaw

~ f<<c a

~

GOULDS PUMPS INC scaccA faLL ~

, R v POEPT'.

/ALA F 5 TcT s<<.s f)Xp.

Al<<l l STONE I WcSSTER E'NG)NEARING CO<<PC<<AT)ON NINE MILE POINT NUCLEAP STATION UN(T 2 NIAGARA4)GNAWN POWER CORPORAI)ON A O. 12112 (MSTRUCT(ONS TO SUPPLIER (EE)

APPROVED AS DEFINED IN APPROVOD AS REV(SED (SPEC)FICATION RELEASEO FOR MATERLAL.PURCHASE REVISED PR)VTS RELEASED FOR FABRICATION REVISED M)CROF)LM APERTURE CARDS SUPPLIER TO RESUBMIT NOTES(

FOR REVIEW FOR RECORD NONE REOU(RED DES)GN E

'ERS DATE STAMP D)

OUT: <<P((

'1 I (ED V FOR NFORNAT)ON ONLT RETURN TO SUPPLIER NOT REOU)REO sf IUCf 0 a 10 Olllsc (C 'ICLCI) a I)

P S

ROC NEW

+ PLUGGED S

Qe BOLT TOROUE WAS 93 (FT-L8) RH b 8DI RH )2-5-79 4

3 WAS 3-1/2.

WAS 4-H/lb.Q5 WAS 4. / 8 3

2 ADDED THERMOCOUPLE NOTE. RH l0.4-79 /

2 ADDED RKH (2-13-78 LT

)

DRAWING WAS PRELIMINARY.

RH 8-24-78"LFB REY.

F AXIAL (LBF)

F SHEAR (LBF) 900 180 24S 147 M BENDING (INLBF) 1619 M TORSION (IN-LBF )

1949 914 1097 MAXIMUM ALLOWABLE DESIGN NOZZLE LOADS SUCTION DISCHARGE GOULDS SERIAL NO.

N779B980 I 2-3-4 S

J NIAGARA MOHAWK POWER CORP.

CUSTOMER PO.

O. NMP2 P222X SERVICE: SEE+ NOTE ITEM NO. 2RHSNP~2 2CSLKP2~2CSH)fP2z2ICSXP~2S PARE ENGR.JOB ORDER: 12177 t

NINE MILE POINT NUCLEAR STATION-UNIT)l2 DRAWN BY: R k' DATE: )2-2$

~ 77 DWG.

¹ CHECKED BY: D/(rl DATE: /2-28-77 IN~)T

(.S OQFELECTED REVIEWc 4,/".

SUPERSEDES 4 I w FILE NO ISO)ls 1<<',

lis-1st MO'Ola'CL34S(CS)

NEFdES'2

"'""le"2k"~G>M'V>>r<<-)

MFR s owG No (c)hrwf \\o ac ccaaacfcs

~ 4 acaaastiatf ao A/773/8CD 4'/ gaL/ d CODE (ED 4RE4 DESICMAT)Ot f1i. act COOLS (EI) fs-ao)

V ass(

llo(l 5 IIFRS NAVE(C)(c c I fo lo casa.cfcas 4 aLaacillal.lo CN CSG/C27 oo AFPF/HF//TP5 Oats lo fa '

I~

FUNCIIU'l4L 1lfLS (ED I

I fo S 'l F)LE NO

)ED

$ 2(77, ll Iv

( ll)