Text

Docket No. 50-220 Mr. G.

K. Rhode Senior Vice President Niagara Mohawk Power Corporation 300 Erie Boulevard West

Syracuse, New York 13202

Dear Mr. Rhode:

aEc 39 ss3

SUBJECT:

SAFETY EVALUATION, REACTOR BUILDING WALL CRACK Re:

Nine Mile Point Nuclear Station, Unit No.

1 We have completed our review of your submittals dated March 25, August 25 and September 12, 1983 on the analyses of the Reactor Building structural integrity and intended corrective actions for the crack in the Reactor Building wall.

Based on our enclosed Safety Evaluation, we concur with your conclusion that the facility can be safely operated until the long-term corrective decoupling of the Reactor Building and Screenhouse wall is completed in the Spring 1984 refueling outage.

Sincerely, Original signed by RAHermann for/

Enclosure:

As stated cc w/enclosure See next page Domenic B. Vassallo, Chief Operating Reactors Branch ¹2 Division of Licensing DISTRIBUTION:

Docket File!

DEisenhut OELD NSIC JTaylor GLear JPearring NRC PDR EJordan ACRS(10)

LPDR RHermann GLainas ORB¹2 Reading SNorris PTam DL'ORB¹2 DL:ORfgg S

res RHerma~

12/4 (/83 12~/83 DE: SGEB p DLQRB¹2 GLear

~Vassallo 12/g$ /83 12/aP/83 8401270019 831229 PDR ADQCK 05000220

'P'

DR

Ij P'

II T,

f'

Mr. G. K. Rhode Niagara Mohawk Power Corporation Nine Mile point Nuclear Station, Unit No.

1 CC:

Troy B. Conner, Jr.,

Esq.

Conner 8 Wetterhahn Suite 1050 1747 pennsylvania

Avenue, N.

W.

Washington, D. C.

20006 Mr. Robert P. Jones, Supervisor Town of Scriba R.

D.

$4

Oswego, New York 13126 Niagara Mohawk power Corporation ATTN:

Mr. Thomas perkins plant Superintendent ll Nine Mi'.e point Nuclear Station Post Office Box 32

Lycoming, New York 13093 U. S. Environmental Protection Agency Region II Office Regional Radiation Representative 26 Federal plaza New York, New York 10007 Resident Inspector U. S. Nuclear Regulatory Commission post Office Box 126
Lycoming, New York 13093 John W. Keib, Esquire Niagara Mohawk power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Thomas A. Murley Regional Administrator Region I Office U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, pennsylvania 19406 Mr. Jay Dunkleberger Division of policy Analysis and Planning New York State Energy Office Agency Building 2, Empire State Plaza
Albany, New York 12223

~