NEWFAX 3165 N58313 ED 7489 INDEX GENERAL NOTES: I. FOR EXPLANATION OF EQUIPMENT, WIRING AND SCHEME SHEET LATEST DESCRIPTION NUMBERS SEE E-11A, ELECTRICAL NUMBERlNG SYSTEMS. NO. 8EV. 2. FOR MOTOR INFORMATION SEE E-128, ELECTRICAL MOTOR LIST. lA 1/74'13] CIRCULATING WATER PUMP 3. FOR CONTROL PANEL, JUNCTION BOX & TERMINAL BOX 18 15 CIRCULATING WATER PUMP DESCRIPTION SEE E-138, ELECTRICAL EQUIPMENT LIST. 1C 8 CIRCULATING WATER PUMP 4. WlRE NUMBER PREFIX MUST BE ADDED TO FORM COMPLETE 2A 6 CIRCULATING WATER PUMP DISCH. VLV'S WIRE NUMBER FOR THOSE WIRES AT MAIN CONTROL BOARD. 5. AUX. CONTROL RELAY IN SOLENOID OPERATED VALVE CONTROL 28 8 CIRCULATING WATER PUMP DISCH. VLV'S CIRCUIT TO BE COUCH RELAY TYPE 4AP44-AF.

2C 10 CIRCULATING WATER PUMP DISCH. VLV'S 6. NUMBERS IN BRACKETS [ J REPRESENTS COMPUTER INPUT NUMBER. NUMBER IN PARENTHESIS ( l REPRESENTS 3A 7 COOLING TOWER MAKE-UP PUMP COMPUTER INPUT SOURCE NUMBER. 3B 9 COOLING TOWER MAKE-UP PUMP 4 9 COOLING TOWER MAKE-UP PUMP STRAINERS 5 6 COOLING TOWER MAKE-UP PUMP BACK WASH VALVES BLOCK DIAGRAM DESIGNATIONS:

6A 11 SERVICE WATER PUMP I 0 A -4. 16 KV SYSTEM SWITCHGEAR 58 13 SERVICE WATER PUMP 1 (AC 107) Q B -480V SYSTEM MOTOR CONTROL CENTER 6C 5 SERVICE WATER PUMP 2 Q C -MAIN CONTROL BOARD 6D 5 SERVICE WATER PUMP 2 (AD 107) Q CA -LOCAL CONTROL CABINET 7 15 SERVICE WATER PUMP STRAINERS 1-2 a E -LOCAL DISTRIBUTION TERMINAL BOX 7A 2 SERVICE WATER PUMP STRAINER t-1 Q H -13.8 KV SYSTEM SWITCHGEAR 78 I SERVICE WATER PUMP STRAINER 1-3 Q M -MOTOR 8 t 3 SERVICE WATER PUMP STRAINERS 1-2 & 1-3 DRAIN VLV a N -LOCAL CONTROL STATION 8A 1 SERVICE WATER PUMP STRAINER 1-1 DRAIN VLV 0 P -PENETRATION TERMINAL BOX 9A t 4 SW ISO VLV'S TO CLNG WTR (MQV'S) 1395 Q RC -AUXILIARY RELAY CABINET 9B 9 SW ISO VLV'S TO CLNG WTR (MOV'S) 1399 a 10 1 DELETED REFERENCE DRAWINGS: l 1 A 14 SERVICE WATER PUMP 3 CH. 1 a E-5 SH. 1 THRU 5 -480V MCC (NON-ESSENTIAL)

ONE LINE DIAGRAM 11 B 16 SERVICE WATER PUMP 3 (AC 109) a E-6 SH. 1 2 -480V MCC (ESSENTIAL)

ONE LINE DIAGRAM 11 c 11 SERVICE WATER PUMP 3 XFER BRKR b

-STANDARD NOTES AND SYMBOLS 1 t D . 6 SERVICE WATER PUMP 3 XFER BRKR Q E-148 -SOLENOID VALVE LIST 1 t E 5 SERVICE WATER PUMP 3 CH.2 Q E-306 -GENERAL GUIDES -ELEMENTARY DIAGRAM 11 F 4 SERVICE WATER PUMP 3 (AD 109) Q THIS DRAWING WAS REDRAWN ON CADD AND SUPERSEDES REVISION 64. 12 6 CTMT AIR CLR'S 1-2 IN ISO VLV (MQV) Q SCALE NONE I DESlGNED I DRAWN EAL loATE 04-13-04 . 12A /74{1 l CTMT AIR CLR'S 1-1 IN ISO VLV (MQV) a DAVIS-BESSE NUCLEAR POWER STATION 13 8 CTMT AIR CLR'S 1-1 & 1-2 OUTLET VLV'S (SOV'S) Q FOR CONTINUATION OF INDEX SEE SH.2. UNIT NO. 1 14A 8 CTMT CLR'S 1-3 IN ISO VLV (MQV) Q THE TOLEDO EDISON COMPANY 148 6 CTMT AIR CLR'S 1-3 IN ISO VLV (MQV) Q ELEMENTARY WIRING DIAGRAMS Q 14C 7 CTMT AIR CLR'S 1-3 IN ISO VLV (MQV) Q LAKE WATER SYSTEM 15 12 ECCS RM CLR'S OUT VLV'S (MQV'S) DWG. VOID Q DRAWING INDEX 16 1 DELETED DRAW[NC NO. REV. E-488 SH. 1 74 DB 05-06-16 . DFN./F/SCHEME/E48BIS01.DGN