NEWFAX 3/85 N583l3 \ CONT. SH.48 MCC <SEE TABLE, SH.48) 480V, 3t, GOHZ i A .... ____ _

..... ----...... -M: c-...,_,..._..,._

5 m OPEN IA T52a 276JL 7 X1co OS 2405 co XB Jl.. 2.SA Xt (Q-xti.l.

SH.48 Xt CLOSE JL 0 0 480-120V I L(') I""') 0 0 I fV") en 0 0 ::E: c:: 0 u.. ,...., en I.(') I a::l c..o "=I" I* L.&.J < > en lJJ LU c::: a:: a:: 0 I"") fV") c 0 0 0:: 0 0 I I 0 --LL. C) C> N 0 0 I I en ,_ co I.(') co co I I"'-LO CD 0 0 c..o I I -=:r--O"> I -0 UJ :z z z :::::> :::> (..) 0 0 c (..) . . u u z z z --...... C> j" '° j" .. c::> u:> a.() cn L(') 0 I fV") 0 c::: <...> 0 . > w 0:: 0 0 I u:> N 0 0 I ,...., 0 a:: <...> LU c:: T3 w a_ I.(') -u:> Tt T3 M I co c..o ...,.. I LJ.J :z u Cl u :z -....., c:> ..!... I c::::> R3 co TR51 ---<:i B TR5l I SEE I t NOTE 13 1 0 TR61 !.. CL2 4.E. CL2 I 42b c i2 42b 0 42 c SCHEME NO. <SEE TABLE SH.48> -CL2 SEE SH.48 r----., I CA I I -I I I I SEE I 1 NOTE 13 r I I I I I CA I L--=-.J EO 7489 INDICATION VALVE LIMIT SWITCH AUX. CONTACTS 3 !.. Rt f CD 7 OS co R ¢JT R GI 2¢..e_ Gt f co 8 OS CD G 9JT G ..k.. wot NOTES: 7 33 I bnY. M M ,--/ [Z006J <ZS-to7> t. FOR LEGEND & BLOCK DIAG. SEE DWG. E-468, SH.4B. 2. FOR GENERAL NOTES, SEE E-46B INDEX SHEET. 3. FIELD TO ADJUST ROTOR 4 SUCH THAT CONTACT 15 WILL PROVIDE SPECIFIED TARGET THRUST ON SEATING. 4. FOR C.S. DETAILS SEE OWG. E-308 SH. 7, FIG.7. 5. FOR VLV LIMIT SWITCH DEV. SEE OWG. E-308 SH.SE, FIG.H <ALSO SEE NOTES 3, 6, AND 10 THIS SHEET>. 6. FIELD TO ADJUST ROTOR 3 SUCH THAT CONTACT 11 CLOSE WHEN VALVE IS CLOSED,(1.E.

AFTER HARD SEAT CONTAC 8. DELETED 9. PSL4931A CONTACT CLOSES ON LOW PRESSURE AT AFP SUCTION. 10. FIELD TO ADJUST ROTOR *2 WITH SWITCH CONTACTS 5 THRU 8 TO ACTUATE WHEN VALVE REACHES 201. OPEN +5°/ -0 /o 13. FOR SFRCS BLOCK SWITCH ANO SCHEMATIC SEE DWG. SF-0038 SH. 14. <NOTES CONT'D ON SH.48) THIS DRAWING WAS REDRAWN ON CAO ANO SUPERCEOES REVISION 16 SCALE NONE DESIGNED DRAWN JOR OATE 05-31-89 J 1 Jr DAVIS-BESSE NUCLEAR POWER STATION *cOMPlNv 10 t--------------t co ELEMENTARY WIRING DIAGRAM Q w STEAM AND CONDENSATE l.. AUX FD PMPS TURBS MN STM IN ISO VLVS -e E-468 SH.4A REV. 25 4 DRAWING NO. DB 04-16-12 DFN=F:/SCHEME/E46BS04A.DGN